메뉴 건너뛰기




Volumn 21, Issue 3, 1998, Pages 147-150

A new biosensor for continuous monitoring of the spent dialysate urea level in standard hemodialysis

Author keywords

Biosensor; Dialysis dose; Hemodialysis; Urea

Indexed keywords

BIOSENSORS; HEMODIALYZERS; IONIC STRENGTH; METABOLISM; MONITORING; REGRESSION ANALYSIS; UREA;

EID: 0031839030     PISSN: 03913988     EISSN: None     Source Type: Journal    
DOI: 10.1177/039139889802100305     Document Type: Article
Times cited : (20)

References (10)
  • 1
    • 0026787628 scopus 로고
    • Adequacy of dialysis. A critical analysis
    • Vanholder R, Ringoir S. Adequacy of dialysis. A critical analysis. Kidney Int 1992; 42: 540-58.
    • (1992) Kidney Int , vol.42 , pp. 540-558
    • Vanholder, R.1    Ringoir, S.2
  • 2
    • 0021783946 scopus 로고
    • A mechanistic analysis of the National Cooperative dialysis Study (NCDS)
    • Gotch FA, Sargent JA. A mechanistic analysis of the National Cooperative dialysis Study (NCDS). Kidney Int 1985; 28: 526-34.
    • (1985) Kidney Int , vol.28 , pp. 526-534
    • Gotch, F.A.1    Sargent, J.A.2
  • 3
    • 0028211649 scopus 로고
    • Assessing adequacy of hemodialysis: Urea modeling
    • Depner TA. Assessing adequacy of hemodialysis: Urea modeling. Kidney Int 1994; 45: 1522-35.
    • (1994) Kidney Int , vol.45 , pp. 1522-1535
    • Depner, T.A.1
  • 4
    • 0030893770 scopus 로고    scopus 로고
    • Studio di un nuovo biosensore per il monitoraggio on-line dell'urea in emodialisi standard
    • Calzavara P, Calconi G, Da Rin G, Cavicchioli G, Canini E. Studio di un nuovo biosensore per il monitoraggio on-line dell'urea in emodialisi standard. Giorn It Nefrol 1997; 14: 47-51.
    • (1997) Giorn It Nefrol , vol.14 , pp. 47-51
    • Calzavara, P.1    Calconi, G.2    Da Rin, G.3    Cavicchioli, G.4    Canini, E.5
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0344935826 scopus 로고
    • Multicenter clinical validation of an on-line urea monitor
    • abstract
    • Depner T, Collins A, Jindal K, et al. Multicenter clinical validation of an on-line urea monitor. (abstract) J Am Soc Nephrol 1993; 4: 343.
    • (1993) J Am Soc Nephrol , vol.4 , pp. 343
    • Depner, T.1    Collins, A.2    Jindal, K.3
  • 8
    • 0028466398 scopus 로고
    • Accuracy of an on-line urea monitor compared with urea kinetic model and direct dialysis quantification
    • Bosticardo GM, Avalle U, Giacchino F, Molino A, Allcatti S. Accuracy of an on-line urea monitor compared with urea kinetic model and direct dialysis quantification. ASAIO J 1994; 20: M426-30.
    • (1994) ASAIO J , vol.20
    • Bosticardo, G.M.1    Avalle, U.2    Giacchino, F.3    Molino, A.4    Allcatti, S.5
  • 9
    • 0029099493 scopus 로고
    • Validazione in vivo di un biosensore per il monitoraggio in continuo dell'urea in paired filtration dialysis
    • Mandolfo S, Colasanti G, Santoro A, et al. Validazione in vivo di un biosensore per il monitoraggio in continuo dell'urea in paired filtration dialysis. Giorn It Nefrol 1995; 12: 263-8.
    • (1995) Giorn It Nefrol , vol.12 , pp. 263-268
    • Mandolfo, S.1    Colasanti, G.2    Santoro, A.3
  • 10
    • 0026650942 scopus 로고
    • KT/V and protein catabolic rate determination from serial urea measurement in the dialysate effluent stream
    • Garred LJ, Di Giuseppe B, Chand W, McCready W, Canaud B. KT/V and protein catabolic rate determination from serial urea measurement in the dialysate effluent stream. Artificial Organs 1992; 16: 248-55.
    • (1992) Artificial Organs , vol.16 , pp. 248-255
    • Garred, L.J.1    Di Giuseppe, B.2    Chand, W.3    McCready, W.4    Canaud, B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.