Volumn 51, Issue 6, 2004, Pages 896-904

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex

Author keywords

Brain computer interface (BCI); Brain machine interface (BMI); Microelectrode; Neuroprosthesis

Indexed keywords

CEREBRAL CORTEX; CHRONIC; RODENTS;

EID: 2442716494     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2004.826680     Document Type: Article
Times cited : (401)

References (44)
  • 4
    • 0037036102 scopus 로고    scopus 로고
    • Direct cortical control of 3D neuroprosthetic devices
    • D. Taylor, S. Tillery, and A. B. Schwartz, "Direct cortical control of 3D neuroprosthetic devices," Science, vol. 296, pp. 1829-1832, 2002.
    • (2002) Science , vol.296 , pp. 1829-1832
    • Taylor, D.1    Tillery, S.2    Schwartz, A.B.3
  • 8
    • 34247271409 scopus 로고    scopus 로고
    • Brain-machine interfaces in rat motor cortex: Neuronal operant conditioning to perform a sensory detection task
    • Capri, Italy
    • R. J. Vetter, K. J. Otto, T. C. Marzullo, and D. R. Kipke, "Brain-machine interfaces in rat motor cortex: Neuronal operant conditioning to perform a sensory detection task," presented at the 1st Int. IEEE EMBS Conf. Neural Eng., Capri, Italy, 2003.
    • (2003) 1st Int. IEEE EMBS Conf. Neural Eng.
    • Vetter, R.J.1    Otto, K.J.2    Marzullo, T.C.3    Kipke, D.R.4
  • 9
    • 33846276804 scopus 로고    scopus 로고
    • Brain-machine interfaces in rat motor cortex: Implications of adaptive decoding algorithms
    • Capri, Italy
    • K. J. Otto, R. J. Vetter, T. C. Marzullo, and D. R. Kipke, "Brain-machine interfaces in rat motor cortex: Implications of adaptive decoding algorithms," presented at the 1st Int. IEEE EMBS Conf Neural Eng., Capri, Italy, 2003.
    • (2003) 1st Int. IEEE EMBS Conf Neural Eng.
    • Otto, K.J.1    Vetter, R.J.2    Marzullo, T.C.3    Kipke, D.R.4
  • 10
    • 0033360081 scopus 로고    scopus 로고
    • Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex
    • J. K. Chapin, K. A. Moxon, R. S. Markowitz, and M. A. Nicolelis, "Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex," Nat. Neurosci., vol. 2, pp. 664-670, 1999.
    • (1999) Nat. Neurosci. , vol.2 , pp. 664-670
    • Chapin, J.K.1    Moxon, K.A.2    Markowitz, R.S.3    Nicolelis, M.A.4
  • 11
    • 0033485808 scopus 로고    scopus 로고
    • Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex
    • J. C. Williams, R. L. Rennaker, and D. R. Kipke, "Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex," Brain Res. Brain Res. Protoc., vol. 4, pp. 303-313, 1999.
    • (1999) Brain Res. Brain Res. Protoc. , vol.4 , pp. 303-313
    • Williams, J.C.1    Rennaker, R.L.2    Kipke, D.R.3
  • 13
    • 0035970965 scopus 로고    scopus 로고
    • Multiple microelectrode-recording system for human intracortical applications
    • I. Ulbert, E. Halgren, G. Heit, and G. Karmos, "Multiple microelectrode-recording system for human intracortical applications," J. Neurosci. Methods, vol. 106, pp. 69-79, 2001.
    • (2001) J. Neurosci. Methods , vol.106 , pp. 69-79
    • Ulbert, I.1    Halgren, E.2    Heit, G.3    Karmos, G.4
  • 15
    • 0001574753 scopus 로고    scopus 로고
    • Micromachined polyimide-based devices for flexible neural interfaces
    • T. Stieglitz, H. Beutel, M. Schuettler, and J. U. Meyer, "Micromachined polyimide-based devices for flexible neural interfaces," Biomed. Microdev., vol. 2, pp. 283-294, 2000.
    • (2000) Biomed. Microdev. , vol.2 , pp. 283-294
    • Stieglitz, T.1    Beutel, H.2    Schuettler, M.3    Meyer, J.U.4
  • 16
    • 0024076268 scopus 로고
    • Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity
    • Sept
    • K. L. Drake, K. D. Wise, J. Farraye, D. J. Anderson, and S. L. BeMent, "Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity," IEEE Trans. Biomed. Eng., vol. 35, pp. 719-732, Sept. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 719-732
    • Drake, K.L.1    Wise, K.D.2    Farraye, J.3    Anderson, D.J.4    BeMent, S.L.5
  • 17
    • 0030575296 scopus 로고    scopus 로고
    • Single unit recording capabilities of a 100 microelectrode array
    • C. T. Nordhausen, E. M. Maynard, and R. A. Normann, "Single unit recording capabilities of a 100 microelectrode array," Brain Res., vol. 726, pp. 129-140, 1996.
    • (1996) Brain Res. , vol.726 , pp. 129-140
    • Nordhausen, C.T.1    Maynard, E.M.2    Normann, R.A.3
  • 20
    • 2442708539 scopus 로고    scopus 로고
    • Wireless implantable microsystems: High-density electronic interfaces to the nervous system
    • Jan
    • K. D. Wise, D. J. Anderson, J. F. Hetke, D. R. Kipke, and K. Najafi, "Wireless implantable microsystems: High-density electronic interfaces to the nervous system," Proc. IEEE, vol. 92, pp. 76-97, Jan. 2004.
    • (2004) Proc. IEEE , vol.92 , pp. 76-97
    • Wise, K.D.1    Anderson, D.J.2    Hetke, J.F.3    Kipke, D.R.4    Najafi, K.5
  • 21
    • 0028416752 scopus 로고
    • Silicon ribbon cables for chronically implantable microelectrode arrays
    • Apr
    • J. F. Hetke, J. L. Lund, K. Najafi, K. D. Wise, and D. J. Anderson, "Silicon ribbon cables for chronically implantable microelectrode arrays," IEEE Trans. Biomed. Eng., vol. 41, pp. 314-321, Apr. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 314-321
    • Hetke, J.F.1    Lund, J.L.2    Najafi, K.3    Wise, K.D.4    Anderson, D.J.5
  • 22
    • 84930318480 scopus 로고    scopus 로고
    • Silicon microelectrodes for extracellular recording,
    • W. E. Finn and P. G. LoPresti, Eds. Boca Raton, FL: CRC
    • J. F. Hetke and D. J. Anderson, "Silicon microelectrodes for extracellular recording," in Handbook of Neuroprosthetic Methods, W. E. Finn and P. G. LoPresti, Eds. Boca Raton, FL: CRC, 2002.
    • (2002) Handbook of Neuroprosthetic Methods
    • Hetke, J.F.1    Anderson, D.J.2
  • 24
    • 0034055301 scopus 로고    scopus 로고
    • A high-yield microassembly structure for three-dimensional microelectrode arrays
    • Mar
    • Q. Bai, K. D. Wise, and D. J. Anderson, "A high-yield microassembly structure for three-dimensional microelectrode arrays," IEEE Trans. Biomed. Eng., vol. 47, pp. 281-289, Mar. 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , pp. 281-289
    • Bai, Q.1    Wise, K.D.2    Anderson, D.J.3
  • 26
    • 0346256850 scopus 로고    scopus 로고
    • Characterization of implantable microfabricated fluid delivery devices
    • Jan
    • R. Rathnasingham, S. C. Bledsoe, J. D. McLaren, and D. R. Kipke, "Characterization of implantable microfabricated fluid delivery devices," IEEE Trans. Biomed. Eng., vol. 51, pp. 138-145, Jan. 2004.
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , pp. 138-145
    • Rathnasingham, R.1    Bledsoe, S.C.2    McLaren, J.D.3    Kipke, D.R.4
  • 27
    • 0034143411 scopus 로고    scopus 로고
    • Coding of sound-source location by ensembles of cortical neurons
    • S. Furukawa, L. Xu, and J. C. Middlebrooks, "Coding of sound-source location by ensembles of cortical neurons," J. Neurosci., vol. 20, pp. 1216-1228, 2000.
    • (2000) J. Neurosci. , vol.20 , pp. 1216-1228
    • Furukawa, S.1    Xu, L.2    Middlebrooks, J.C.3
  • 28
    • 0037461750 scopus 로고    scopus 로고
    • Mechanisms of gamma oscillations in the hippocampus of the behaving rat
    • J. Csicsvari, B. Jamieson, K. D. Wise, and G. Buzsaki, "Mechanisms of gamma oscillations in the hippocampus of the behaving rat," Neuron, vol. 37, pp. 311-322, 2003.
    • (2003) Neuron , vol.37 , pp. 311-322
    • Csicsvari, J.1    Jamieson, B.2    Wise, K.D.3    Buzsaki, G.4
  • 29
    • 0041853789 scopus 로고    scopus 로고
    • Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex
    • June
    • D. R. Kipke, R. J. Vetter, J. C. Williams, and J. F. Hetke, "Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex," IEEE Trans. Rehab. Eng., vol. 11, pp. 151-155, June 2003.
    • (2003) IEEE Trans. Rehab. Eng. , vol.11 , pp. 151-155
    • Kipke, D.R.1    Vetter, R.J.2    Williams, J.C.3    Hetke, J.F.4
  • 30
    • 84942604301 scopus 로고    scopus 로고
    • The use of ALGEL as an artificial dura for chronic cortical implant neuroprosthetics
    • Capri, Italy
    • R. J. Vetter, T. A. Becker, J. C. Williams, and D. R. Kipke, "The use of ALGEL as an artificial dura for chronic cortical implant neuroprosthetics," presented at the 1st Int. IEEE EMBS Conf. Neural Eng., Capri, Italy, 2003.
    • (2003) 1st Int. IEEE EMBS Conf. Neural Eng.
    • Vetter, R.J.1    Becker, T.A.2    Williams, J.C.3    Kipke, D.R.4
  • 33
    • 0032125652 scopus 로고    scopus 로고
    • Chronic recording capability of the utah intracortical electrode array in cat sensory cortex
    • P. J. Rousche and R. A. Normann, "Chronic recording capability of the utah intracortical electrode array in cat sensory cortex," J. Neurosci. Meth., vol. 82, pp. 1-15, 1998.
    • (1998) J. Neurosci. Meth. , vol.82 , pp. 1-15
    • Rousche, P.J.1    Normann, R.A.2
  • 34
    • 0033198609 scopus 로고    scopus 로고
    • Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes
    • Sept
    • X. Liu, D. B. McCreery, R. R. Carter, L. A. Bullara, T. G. Yuen, and W. F. Agnew, "Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes," IEEE Trans. Rehab. Eng., vol. 7, pp. 315-326, Sept. 1999.
    • (1999) IEEE Trans. Rehab. Eng. , vol.7 , pp. 315-326
    • Liu, X.1    McCreery, D.B.2    Carter, R.R.3    Bullara, L.A.4    Yuen, T.G.5    Agnew, W.F.6
  • 36
    • 1542315769 scopus 로고    scopus 로고
    • Correlation analysis of electrical interface properties of chronic neural implants
    • J. C. Williams, G. D. Smith, R. J. Vetter, and D. R. Kipke, "Correlation analysis of electrical interface properties of chronic neural implants," Soc. Neurosci. Abstr., 2001.
    • (2001) Soc. Neurosci. Abstr.
    • Williams, J.C.1    Smith, G.D.2    Vetter, R.J.3    Kipke, D.R.4
  • 37
    • 0034655830 scopus 로고    scopus 로고
    • A technique to prevent dural adhesions to chronically implanted microelectrode arrays
    • E. M. Maynard, E. Fernandez, and R. A. Normann, "A technique to prevent dural adhesions to chronically implanted microelectrode arrays," J Neurosci. Meth., vol. 97, pp. 93-101, 2000.
    • (2000) J. Neurosci. Meth. , vol.97 , pp. 93-101
    • Maynard, E.M.1    Fernandez, E.2    Normann, R.A.3
  • 41
  • 42
    • 0031214943 scopus 로고    scopus 로고
    • A multichannel neural probe for selective chemical delivery at the cellular level
    • Aug
    • J. Chen, K. D. Wise, J. F. Hetke, and S. C. Bledsoe Jr., "A multichannel neural probe for selective chemical delivery at the cellular level," IEEE Trans. Biomed. Eng., vol. 44, pp. 760-769, Aug. 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , pp. 760-769
    • Chen, J.1    Wise, K.D.2    Hetke, J.F.3    Bledsoe Jr., S.C.4
  • 43
    • 84964600728 scopus 로고    scopus 로고
    • Silicon recording arrays with on-chip electronics for in-vivo data acquisition
    • Madison, WI
    • R. H. Olsson, M. N. Gulari, and K. D. Wise, "Silicon recording arrays with on-chip electronics for in-vivo data acquisition," presented at the IEEE-EMBS Conf. Microtechnologies Med. Biol., Madison, WI, 2002.
    • (2002) IEEE-EMBS Conf. Microtechnologies Med. Biol.
    • Olsson, R.H.1    Gulari, M.N.2    Wise, K.D.3
  • 44
    • 2442661020 scopus 로고    scopus 로고
    • Long term measurements of polyimide electrical characteristics for use in chronically implanted neural probes
    • Cancun, SE, Mexico
    • S. Nikles, D. S. Pellinen, D. R. Kipke, and K. Najafi, "Long term measurements of polyimide electrical characteristics for use in chronically implanted neural probes," presented at the 25th Annu. Int. Conf. IEEE Eng. Medicine and Biology Soc., Cancun, SE, Mexico, 2003.
    • (2003) 25th Annu. Int. Conf. IEEE Eng. Medicine and Biology Soc.
    • Nikles, S.1    Pellinen, D.S.2    Kipke, D.R.3    Najafi, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.