-
1
-
-
0026882265
-
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
-
D. Edell, V. Toi, V. McNeil, and C. Clark, "Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex," IEEE Trans Biomed Eng, vol. 39, pp. 635-643, 1992.
-
(1992)
IEEE Trans Biomed Eng
, vol.39
, pp. 635-643
-
-
Edell, D.1
Toi, V.2
McNeil, V.3
Clark, C.4
-
2
-
-
0024426523
-
The cone electrode: A long-term electrode that records from neuritis grown onto its recording surface
-
P. Kennedy, "The cone electrode: a long-term electrode that records from neuritis grown onto its recording surface." J.Neurosci.Methods, vol. 29, pp. 181-193, 1989.
-
(1989)
J.Neurosci.Methods
, vol.29
, pp. 181-193
-
-
Kennedy, P.1
-
3
-
-
0033198609
-
Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes
-
X. Liu, D. McCreery, R. Carter, L. Bullara, T. Yuen, and W. Agnew, "Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes," IEEE Trans Rehabil Eng, vol. 7, pp. 315-326, 1999.
-
(1999)
IEEE Trans Rehabil Eng
, vol.7
, pp. 315-326
-
-
Liu, X.1
McCreery, D.2
Carter, R.3
Bullara, L.4
Yuen, T.5
Agnew, W.6
-
4
-
-
0034655830
-
A technique to prevent dural adhesions to chronically implanted microelectrode arrays
-
April
-
E. Maynard, E. Fernandez, and R. Normann, "A technique to prevent dural adhesions to chronically implanted microelectrode arrays," J Neurosci Methods, vol. 97, pp. 93-101, April 2000.
-
(2000)
J Neurosci Methods
, vol.97
, pp. 93-101
-
-
Maynard, E.1
Fernandez, E.2
Normann, R.3
-
5
-
-
0035095902
-
Flexible polyimide-based intracortical electrode arrays with bioactive capability
-
P. Rousche, D. Pellinen, D. Pivin, J. Williams, R. Vetter, and D. Kipke, "Flexible polyimide-based intracortical electrode arrays with bioactive capability," IEEE Trans Biomed Eng. Vol. 48, pp. 361-371, 2001.
-
(2001)
IEEE Trans Biomed Eng
, vol.48
, pp. 361-371
-
-
Rousche, P.1
Pellinen, D.2
Pivin, D.3
Williams, J.4
Vetter, R.5
Kipke, D.6
-
7
-
-
0033485808
-
Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex
-
J. Williams, R. Rennaker, and D. Kipke, "Long-term neural recording characteristics of wire microelectrode arrays implanted in cerebral cortex," Brain Res. Protoc, vol. 4, pp. 303-313, 1999.
-
(1999)
Brain Res. Protoc
, vol.4
, pp. 303-313
-
-
Williams, J.1
Rennaker, R.2
Kipke, D.3
-
9
-
-
0035196148
-
Calcium alginate gel: A biocompatible and mechanically stable polymer for endovascular embolization
-
T. Becker, D. Kipke, and T. Brandon, "Calcium alginate gel: a biocompatible and mechanically stable polymer for endovascular embolization," J Biomed Mater Res, vol. 54, pp. 76-86, 2001.
-
(2001)
J Biomed Mater Res
, vol.54
, pp. 76-86
-
-
Becker, T.1
Kipke, D.2
Brandon, T.3
-
10
-
-
0036705689
-
In vivo assessment of calcium alginate gel for endovascular embolization of a swine rete model
-
T. Becker, D Kipke, C McDougall, M. Preul, W. Bichard, "In vivo assessment of calcium alginate gel for endovascular embolization of a swine rete model," Neurosurgery vol. 51, pp. 453-59, 2002.
-
(2002)
Neurosurgery
, vol.51
, pp. 453-459
-
-
Becker, T.1
Kipke, D.2
McDougall, C.3
Preul, M.4
Bichard, W.5
-
11
-
-
0020426497
-
Quantitative analysis of methods for reducing physiological brain pulsations
-
R. Britt, and G. Rossi, "Quantitative analysis of methods for reducing physiological brain pulsations," J Neurosci Methods, vol. 6, pp. 219-229, 1982.
-
(1982)
J Neurosci Methods
, vol.6
, pp. 219-229
-
-
Britt, R.1
Rossi, G.2
-
12
-
-
0037086855
-
Dural substitute for long-term imaging or cortical activity in behaving monkeys and its clinical implications
-
A. Arieli, A. Grinvald, and H. Slovin, "Dural substitute for long-term imaging or cortical activity in behaving monkeys and its clinical implications." J Neurosci Methods, vol. 114, pp. 119-133, 2002.
-
(2002)
J Neurosci Methods
, vol.114
, pp. 119-133
-
-
Arieli, A.1
Grinvald, A.2
Slovin, H.3
-
13
-
-
85081881832
-
Anti-Inflammatory agents decrease early reactive response to neural prosthesis insertion
-
presented at, San Diego, USA
-
W. Shain et al., "Anti-Inflammatory agents decrease early reactive response to neural prosthesis insertion." presented at 31st Annual Society for Neuroscience Conference, San Diego, USA, 2001.
-
(2001)
31st Annual Society for Neuroscience Conference
-
-
Shain, W.1
|