메뉴 건너뛰기




Volumn 4, Issue , 2003, Pages 3333-3336

Chemical Sensing Capability of MEMS Implantable Multichannel Neural Microelectrode Arrays

Author keywords

Chemical detection; Dopamine; Drug delivery; Nafion; Neural interface

Indexed keywords

BLOOD; BRAIN; CHEMICAL SENSORS; DRUG DOSAGE; MICROELECTRODES; MICROELECTROMECHANICAL DEVICES; POLYMERS;

EID: 1542300293     PISSN: 05891019     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (10)

References (13)
  • 3
    • 0031214943 scopus 로고    scopus 로고
    • A multichannel neural probe for selective chemical delivery at the cellular level
    • August
    • J. Chen, K. Wise, J. Hetke, and S. Bledsoe Jr., "A multichannel neural probe for selective chemical delivery at the cellular level," IEEE Trans. Biomed. Eng., vol. 44, no.8, pp. 760-769, August 1997.
    • (1997) IEEE Trans. Biomed. Eng. , vol.44 , Issue.8 , pp. 760-769
    • Chen, J.1    Wise, K.2    Hetke, J.3    Bledsoe Jr., S.4
  • 5
    • 0036802032 scopus 로고    scopus 로고
    • In vivo neurochemical monitoring by microdialysis and capillary separations
    • Oct.
    • R. Kennedy, C. Watson, W. Haskins, D. Powell, and R. Strecker, "In vivo neurochemical monitoring by microdialysis and capillary separations," Curr. Opin. Chem. Biol., vol. 6, no. 5, pp. 659-665, Oct. 2002.
    • (2002) Curr. Opin. Chem. Biol. , vol.6 , Issue.5 , pp. 659-665
    • Kennedy, R.1    Watson, C.2    Haskins, W.3    Powell, D.4    Strecker, R.5
  • 6
    • 0030587040 scopus 로고    scopus 로고
    • Microelectrodes for the measurement of catecholamines in biological systems
    • P. Cahill, et al, "Microelectrodes for the measurement of catecholamines in biological systems," Anal. Chem., vol. 68, no. 18, pp. 3180-3186, 1996.
    • (1996) Anal. Chem. , vol.68 , Issue.18 , pp. 3180-3186
    • Cahill, P.1
  • 7
    • 0037201553 scopus 로고    scopus 로고
    • Improved ceramic-based multisite microelectrode for rapid measurements of L-glutamate in the CNS
    • J. Burmeister, F. Pomerleau, M. Palmer, B. Day, P. Huettl, and G. Gerhardt, "Improved ceramic-based multisite microelectrode for rapid measurements of L-glutamate in the CNS," J. Neurosci. Methods, vol. 119, pp. 163-171, 2002.
    • (2002) J. Neurosci. Methods , vol.119 , pp. 163-171
    • Burmeister, J.1    Pomerleau, F.2    Palmer, M.3    Day, B.4    Huettl, P.5    Gerhardt, G.6
  • 8
    • 0033975843 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrodes for electrochemical recordings
    • J. Burmeister, K. Moxon, and G. Gerhardt, "Ceramic-based multisite microelectrodes for electrochemical recordings," Anal. Chem., vol. 72, pp. 187-192, 2000.
    • (2000) Anal. Chem. , vol.72 , pp. 187-192
    • Burmeister, J.1    Moxon, K.2    Gerhardt, G.3
  • 9
    • 0024731143 scopus 로고
    • Measurement of nanomolar dopamine diffusion using low-noise perfluorinated ionomer coated carbon fiber microelectrodes and high-speed cyclic voltammetry
    • M. Rice and C. Nicholson, "Measurement of nanomolar dopamine diffusion using low-noise perfluorinated ionomer coated carbon fiber microelectrodes and high-speed cyclic voltammetry," Anal. Chem., vol. 61, pp. 1805-1810, 1989.
    • (1989) Anal. Chem. , vol.61 , pp. 1805-1810
    • Rice, M.1    Nicholson, C.2
  • 10
    • 0023767220 scopus 로고
    • Detection of dopamine dynamics in the brain
    • R. Wightman, L. May, and A. Michael, "Detection of dopamine dynamics in the brain," Anal. Chem., vol. 60, no. 13, pp. 769A-779A, 1988.
    • (1988) Anal. Chem. , vol.60 , Issue.13
    • Wightman, R.1    May, L.2    Michael, A.3
  • 11
    • 0033031501 scopus 로고    scopus 로고
    • Cerebral astrocyte response to micromachined silicon implants
    • J. Turner, et al., "Cerebral astrocyte response to micromachined silicon implants," Exp. Neur., vol. 156, pp. 33-49, 1999.
    • (1999) Exp. Neur. , vol.156 , pp. 33-49
    • Turner, J.1
  • 12
    • 0025731433 scopus 로고
    • Preliminary in vivo biocompatibility studies on perfluorosulphonic acid polymer membranes for biosensor applications
    • May
    • R. Turner, D. Harrison, and R. Rajotte, "Preliminary in vivo biocompatibility studies on perfluorosulphonic acid polymer membranes for biosensor applications," [abstract] Biomaterials, vol. 12, no. 4, pp. 361-368, May 1991.
    • (1991) Biomaterials , vol.12 , Issue.4 , pp. 361-368
    • Turner, R.1    Harrison, D.2    Rajotte, R.3
  • 13
    • 0035882499 scopus 로고    scopus 로고
    • Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry
    • Aug
    • G. Gerhardt and A. Hoffman, "Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry," J. Neurosci. Methods, vol. 109, no. 1, pp. 13-21, Aug 2001.
    • (2001) J. Neurosci. Methods , vol.109 , Issue.1 , pp. 13-21
    • Gerhardt, G.1    Hoffman, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.