메뉴 건너뛰기




Volumn 63, Issue 7, 2016, Pages 1463-1472

Monitoring of Postoperative Bone Healing Using Smart Trauma-Fixation Device with Integrated Self-Powered Piezo-Floating-Gate Sensors

Author keywords

Bone healing monitoring; self powered piezo floating gate (PFG) sensors; Smart trauma fixation device

Indexed keywords

FRACTURE; FRACTURE FIXATION; IMAGING TECHNIQUES; RECONFIGURABLE HARDWARE; SURGERY;

EID: 84978083311     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2015.2496237     Document Type: Article
Times cited : (37)

References (41)
  • 2
    • 0036951741 scopus 로고    scopus 로고
    • An economic evaluation of early versus delayed operative treatment in patients with closed tibial shaft fractures
    • Dec.
    • S. Sprague and M. Bhandari, "An economic evaluation of early versus delayed operative treatment in patients with closed tibial shaft fractures," Arch. Orthop. Trauma Surg., vol. 122, no. 6, pp. 315-323, Dec. 2012.
    • (2012) Arch. Orthop. Trauma Surg. , vol.122 , Issue.6 , pp. 315-323
    • Sprague, S.1    Bhandari, M.2
  • 3
    • 0022356132 scopus 로고
    • Accuracy of radiologic assessment of tibial shaft fracture union in humans
    • Oct.
    • R. R. Hammer et al., "Accuracy of radiologic assessment of tibial shaft fracture union in humans," Clin. Orthop. Related Res., vol. 199, pp. 233-238, Oct. 1985.
    • (1985) Clin. Orthop. Related Res. , vol.199 , pp. 233-238
    • Hammer, R.R.1
  • 4
    • 0032716271 scopus 로고    scopus 로고
    • Correlation of radiographic measurements with biomechanical test results
    • Nov.
    • H. Sano et al., "Correlation of radiographic measurements with biomechanical test results," Clin. Orthop. Related Res., vol. 368, pp. 271-278, Nov. 1999.
    • (1999) Clin. Orthop. Related Res. , vol.368 , pp. 271-278
    • Sano, H.1
  • 5
    • 33750263731 scopus 로고    scopus 로고
    • Clinical experiences with ultrasonometric measurement of fracture healing
    • W.Glinkowski andA.Gorecki, "Clinical experiences with ultrasonometric measurement of fracture healing," Technol. Health Care, vol. 14, pp. 321-333, 2006.
    • (2006) Technol. Health Care , vol.14 , pp. 321-333
    • Glinkowski, W.1    Gorecki, A.2
  • 6
    • 33644976374 scopus 로고    scopus 로고
    • Transosseous application of low-intensity ultrasound for the enhancement and monitoring of fracture healing process in a sheep osteotomy model
    • Apr.
    • K. N. Malizos et al., "Transosseous application of low-intensity ultrasound for the enhancement and monitoring of fracture healing process in a sheep osteotomy model," Bone, vol. 38, pp. 530-539, Apr. 2006.
    • (2006) Bone , vol.38 , pp. 530-539
    • Malizos, K.N.1
  • 7
    • 44949252944 scopus 로고    scopus 로고
    • Ultrasonic monitoring of bone fracture healing
    • Jun.
    • V. C. Protopappas et al., "Ultrasonic monitoring of bone fracture healing," IEEE Trans.Ultrason., Ferroelect., Freq. Control, vol. 6, no. 55, pp. 1243-1255, Jun. 2008.
    • (2008) IEEE Trans.Ultrason., Ferroelect., Freq. Control , vol.6 , Issue.55 , pp. 1243-1255
    • Protopappas, V.C.1
  • 8
    • 67949123265 scopus 로고    scopus 로고
    • Monitoring themechanical properties of healing bone
    • Aug.
    • L. E. Claes, J. L. Cunningham, "Monitoring themechanical properties of healing bone," Clin. Orthop. Related Res., vol. 467, no. 8, pp. 1964-1971, Aug. 2009.
    • (2009) Clin. Orthop. Related Res. , vol.467 , Issue.8 , pp. 1964-1971
    • Claes, L.E.1    Cunningham, J.L.2
  • 9
    • 84864445209 scopus 로고    scopus 로고
    • Monitoring of fracture healing by electrical conduction: A new diagnostic procedure
    • Aug.
    • S. Kumaravel and S. Sundaram, "Monitoring of fracture healing by electrical conduction: A new diagnostic procedure," Indian J. Orthop., vol. 46, no. 4, pp. 384-390, Aug. 2012.
    • (2012) Indian J. Orthop. , vol.46 , Issue.4 , pp. 384-390
    • Kumaravel, S.1    Sundaram, S.2
  • 10
    • 0028300016 scopus 로고
    • Measuring stiffness can define healing of tibial fractures
    • May
    • J. B. Richardson et al., "Measuring stiffness can define healing of tibial fractures," J. Bone Joint Surg. Br., vol. 76, pp. 389-394, May 1994.
    • (1994) J. Bone Joint Surg. Br. , vol.76 , pp. 389-394
    • Richardson, J.B.1
  • 11
    • 0029411967 scopus 로고
    • Fracture stiffnessmeasurement in tibial shaft fractures: A non-invasive method
    • Dec.
    • K. M. Shah et al., "Fracture stiffnessmeasurement in tibial shaft fractures: A non-invasive method," Clin. Biomech., vol. 10, pp. 395-400, Dec. 1995.
    • (1995) Clin. Biomech. , vol.10 , pp. 395-400
    • Shah, K.M.1
  • 12
    • 0036934223 scopus 로고    scopus 로고
    • Monitoring and healing analysis of 100 tibial shaft fractures
    • Jul.
    • L. Claes et al., "Monitoring and healing analysis of 100 tibial shaft fractures," Langenbecks Arch. Surg., vol. 387, pp. 146-152, Jul. 2002.
    • (2002) Langenbecks Arch. Surg. , vol.387 , pp. 146-152
    • Claes, L.1
  • 13
    • 0013873902 scopus 로고
    • Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons
    • N. W. Rydell, "Forces acting on the femoral head-prosthesis. A study on strain gauge supplied prostheses in living persons," Acta Orthopaedica Scandinavica, vol. 37, no. 88, pp. 1-132, 1966.
    • (1966) Acta Orthopaedica Scandinavica , vol.37 , Issue.88 , pp. 1-132
    • Rydell, N.W.1
  • 14
    • 0030152249 scopus 로고    scopus 로고
    • Instrumented implant for measuring tibiofemoral forces
    • May
    • K. R. Kaufman et al., "Instrumented implant for measuring tibiofemoral forces," J. Biomech., vol. 29, pp. 667-671, May 1996.
    • (1996) J. Biomech. , vol.29 , pp. 667-671
    • Kaufman, K.R.1
  • 15
    • 84865165594 scopus 로고    scopus 로고
    • High-tech hip implant for wireless temperature measurements in vivo
    • Aug.
    • G. Bergmann et al., "High-tech hip implant for wireless temperature measurements in vivo," PLoS ONE, vol. 7, no. 8, p. e43489, Aug. 2012.
    • (2012) PLoS ONE , vol.7 , Issue.8 , pp. e43489
    • Bergmann, G.1
  • 16
    • 84879468781 scopus 로고    scopus 로고
    • A new approach for diagnostic investigation of total hip replacement loosening
    • Jan.
    • C. Ruther et al., "A new approach for diagnostic investigation of total hip replacement loosening," Biomed. Eng. Syst. Technol., vol. 273, pp 74-79, Jan. 2011.
    • (2011) Biomed. Eng. Syst. Technol. , vol.273 , pp. 74-79
    • Ruther, C.1
  • 17
    • 0034772283 scopus 로고    scopus 로고
    • E-Knee: Evolution of the electronic knee prosthesis: Telemetry technology development
    • B. A. Morris et al., "E-Knee: Evolution of the electronic knee prosthesis: Telemetry technology development," J. Bone Joint Surg. Am., vol. 83-A, no. 2, pp. 62-66, 2001.
    • (2001) J. Bone Joint Surg. Am. , vol.83-A , Issue.2 , pp. 62-66
    • Morris, B.A.1
  • 18
    • 84879880025 scopus 로고    scopus 로고
    • The influence of footwear on knee joint loading during walking-In vivo load measurements with instrumented knee implants
    • Feb.
    • I. Kutzner et al., "The influence of footwear on knee joint loading during walking-In vivo load measurements with instrumented knee implants," J. Biomech., vol. 46, no. 4, pp. 796-800, Feb. 2013.
    • (2013) J. Biomech. , vol.46 , Issue.4 , pp. 796-800
    • Kutzner, I.1
  • 19
    • 0031106729 scopus 로고    scopus 로고
    • Telemetry of forces from proximal femoral replacements and relevance to fixation
    • Mar.
    • S. J. Taylor et al., "Telemetry of forces from proximal femoral replacements and relevance to fixation," J. Biomech., vol. 30, pp. 225-234, Mar. 1997.
    • (1997) J. Biomech. , vol.30 , pp. 225-234
    • Taylor, S.J.1
  • 20
    • 0034988889 scopus 로고    scopus 로고
    • Loads acting in an intramedullary nail during fracture healing in the human femur
    • Jul.
    • E. Schneider et al., "Loads acting in an intramedullary nail during fracture healing in the human femur," J. Biomech., vol. 34, no. 7, pp. 849-857, Jul. 2001.
    • (2001) J. Biomech. , vol.34 , Issue.7 , pp. 849-857
    • Schneider, E.1
  • 21
    • 34249939216 scopus 로고    scopus 로고
    • Design, calibration and pre-clinical testing of an instrumented tibial tray
    • B. Heinlein et al., "Design, calibration and pre-clinical testing of an instrumented tibial tray," J. Biomech., vol. 40, pp. S4-S10, 2007.
    • (2007) J. Biomech. , vol.40 , pp. S4-S10
    • Heinlein, B.1
  • 22
    • 33846669123 scopus 로고    scopus 로고
    • Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants
    • Feb.
    • F. Graichen et al., "Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants," IEEE Trans. Biomed. Eng., vol. 54, no. 2, pp. 253-261, Feb. 2007.
    • (2007) IEEE Trans. Biomed. Eng. , vol.54 , Issue.2 , pp. 253-261
    • Graichen, F.1
  • 23
    • 27144547214 scopus 로고    scopus 로고
    • The use of piezoelectric ceramics for electric power generationwithin orthopedic implants
    • Aug.
    • S. R. Platt et al., "The use of piezoelectric ceramics for electric power generationwithin orthopedic implants," IEEE ASME Trans.Mechatronics, vol. 10, no. 4, pp. 455-461, Aug. 2005.
    • (2005) IEEE ASME Trans.Mechatronics , vol.10 , Issue.4 , pp. 455-461
    • Platt, S.R.1
  • 24
    • 84966725483 scopus 로고    scopus 로고
    • Energy harvesting for the implantable biomedical devices: Issues and challenges
    • Dec.
    • M. Hannan et al., "Energy harvesting for the implantable biomedical devices: Issues and challenges," BioMed. Eng., vol. 13, pp. 1-23, Dec. 2014.
    • (2014) BioMed. Eng. , vol.13 , pp. 1-23
    • Hannan, M.1
  • 25
    • 0023817870 scopus 로고
    • External ultrasound can generate microampere direct currents in vivo from implanted piezoelectric materials
    • G. V. Cochran et al., "External ultrasound can generate microampere direct currents in vivo from implanted piezoelectric materials," J. Orthopedic Res., vol. 6, no. 1, pp. 145-147, 1988.
    • (1988) J. Orthopedic Res. , vol.6 , Issue.1 , pp. 145-147
    • Cochran, G.V.1
  • 28
    • 84913580570 scopus 로고    scopus 로고
    • Self-powered piezo-floating-gate smart-gauges based on quasi-static mechanical energy concentrators and triggers
    • Feb.
    • N. Lajnef et al., "Self-powered piezo-floating-gate smart-gauges based on quasi-static mechanical energy concentrators and triggers," IEEE Sens. J., vol. 15, no. 2, pp. 676-683, Feb. 2015.
    • (2015) IEEE Sens. J. , vol.15 , Issue.2 , pp. 676-683
    • Lajnef, N.1
  • 29
    • 84978172041 scopus 로고    scopus 로고
    • Poster ECR 2013/C-1645, [Online]. Available
    • B. Geerts andK. L.Verstraete. (2013).Nonunion From Head to Toe. Poster ECR 2013/C-1645. [Online]. Available: http://posterng.netkey.at/esr/viewing/index.php?module=viewing-poster&doi=10.1594/ecr2013/C-1645
    • (2013) Nonunion from Head to Toe
    • Geerts, B.1    Verstraete, K.L.2
  • 30
    • 0031734172 scopus 로고    scopus 로고
    • Concepts of fracture union, delayed union, nonunion
    • Oct.
    • D. Marsh, "Concepts of fracture union, delayed union, nonunion," Clin. Orthop. Related Res., vol. 355, S22-S30, Oct. 1998.
    • (1998) Clin. Orthop. Related Res. , vol.355 , pp. S22-S30
    • Marsh, D.1
  • 31
    • 79551565253 scopus 로고    scopus 로고
    • Far cortical locking enables flexible fixation with periarticular locking plates
    • Feb.
    • J. Doornink et al., "Far cortical locking enables flexible fixation with periarticular locking plates," J. Orthop. Trauma, vol. 25, pp. S29-S34, Feb. 2011.
    • (2011) J. Orthop. Trauma , vol.25 , pp. S29-S34
    • Doornink, J.1
  • 32
    • 33748965764 scopus 로고    scopus 로고
    • The effect of plate rotation on the stiffness of femoral LISS: A mechanical study
    • Sep.
    • A. Khalafi et al., "The effect of plate rotation on the stiffness of femoral LISS: A mechanical study," J. Orthop. Trauma, vol. 20, pp. 542-546, Sep. 2006.
    • (2006) J. Orthop. Trauma , vol.20 , pp. 542-546
    • Khalafi, A.1
  • 33
    • 80255138084 scopus 로고    scopus 로고
    • Rail-to-rail, linear hot-electron injection programming of floating-gate voltage bias generators at 13-bit resolution
    • Nov.
    • C. Huang et al., "Rail-to-rail, linear hot-electron injection programming of floating-gate voltage bias generators at 13-bit resolution," IEEE J. Solid-State Circuits, vol. 46, no. 11, pp. 2685-2692, Nov. 2011.
    • (2011) IEEE J. Solid-State Circuits , vol.46 , Issue.11 , pp. 2685-2692
    • Huang, C.1
  • 34
    • 84856455418 scopus 로고    scopus 로고
    • An asynchronous analog self-powered sensor-data-logger with a 13.56 MHz RF programming interface
    • Feb.
    • C. Huang and S. Chakrabartty, "An asynchronous analog self-powered sensor-data-logger with a 13.56 MHz RF programming interface," IEEE J. Solid-State Circuits, vol. 47, no. 2, pp. 476-489, Feb. 2012.
    • (2012) IEEE J. Solid-State Circuits , vol.47 , Issue.2 , pp. 476-489
    • Huang, C.1    Chakrabartty, S.2
  • 35
    • 77949360212 scopus 로고    scopus 로고
    • Calibration and characterization of self-powered floating-gate usage monitors with single electron per second operational limit
    • Mar.
    • C. Huang et al., "Calibration and characterization of self-powered floating-gate usage monitors with single electron per second operational limit," IEEE Trans. Circuits Syst. I, Reg. Papers, vol. 57, no. 3, pp. 556-567, Mar. 2010.
    • (2010) IEEE Trans. Circuits Syst. I, Reg. Papers , vol.57 , Issue.3 , pp. 556-567
    • Huang, C.1
  • 36
    • 84883465945 scopus 로고    scopus 로고
    • Compressive self-powering of piezofloating-gate mechanical impact detectors
    • Sep.
    • P. Sarkar and S. Chakrabartty, "Compressive self-powering of piezofloating-gate mechanical impact detectors," IEEE Trans. Circuits Syst. I, Reg. Papers, vol. 60, no. 9, pp. 2311-2320, Sep. 2013.
    • (2013) IEEE Trans. Circuits Syst. I, Reg. Papers , vol.60 , Issue.9 , pp. 2311-2320
    • Sarkar, P.1    Chakrabartty, S.2
  • 37
    • 84907389385 scopus 로고    scopus 로고
    • Monitoring of repeated head impacts using time-dilation based self-powered sensing
    • Melbourne, Australia, Jun.
    • K. Aono et al., "Monitoring of repeated head impacts using time-dilation based self-powered sensing," in Proc. IEEE Int. Symp. Circuits Syst., Melbourne, Australia, Jun. 2014, pp. 1620-1623.
    • (2014) Proc IEEE Int. Symp. Circuits Syst. , pp. 1620-1623
    • Aono, K.1
  • 38
    • 84946217369 scopus 로고    scopus 로고
    • Feasibility of B-mode diagnostic ultrasound energy transfer and telemetry to a cm2 sized deep-tissue implant
    • Lisbon, Portugal, May
    • B. Fang et al., "Feasibility of B-mode diagnostic ultrasound energy transfer and telemetry to a cm2 sized deep-tissue implant," in Proc. IEEE Symp. Circuits Syst., Lisbon, Portugal, May 2015, pp. 782-785.
    • (2015) Proc IEEE Symp. Circuits Syst. , pp. 782-785
    • Fang, B.1
  • 39
    • 84928949868 scopus 로고    scopus 로고
    • Self-powered monitoring of repeated head impacts using time dilation energy measurement circuit
    • Apr.
    • T. Feng et al., "Self-powered monitoring of repeated head impacts using time dilation energy measurement circuit," IEEE Trans. Biomed. Circuits Syst., vol. 9, no. 2, pp. 217-226, Apr. 2015.
    • (2015) IEEE Trans. Biomed. Circuits Syst. , vol.9 , Issue.2 , pp. 217-226
    • Feng, T.1
  • 40
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Jul.
    • G. Bergmann et al., "Hip contact forces and gait patterns from routine activities," J. Biomech., vol. 34, no. 7, pp. 859-871, Jul. 2001.
    • (2001) J. Biomech. , vol.34 , Issue.7 , pp. 859-871
    • Bergmann, G.1
  • 41
    • 4644222787 scopus 로고    scopus 로고
    • Biomechanics of locked plates and screws
    • Sep.
    • K. A. Egol et al., "Biomechanics of locked plates and screws," J. Orthop. Trauma., vol. 18, no. 8, pp. 488-493, Sep. 2004.
    • (2004) J. Orthop. Trauma. , vol.18 , Issue.8 , pp. 488-493
    • Egol, K.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.