메뉴 건너뛰기




Volumn 40, Issue SUPPL. 1, 2007, Pages S4-

Design, calibration and pre-clinical testing of an instrumented tibial tray

Author keywords

Knee joint; Load; Measurement; Telemetry; Total knee arthroplasty

Indexed keywords

BONE; ENCAPSULATION; KINETICS; PHYSICAL THERAPY; STRAIN GAGES; TELEMETERING; TITANIUM ALLOYS;

EID: 34249939216     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2007.02.014     Document Type: Article
Times cited : (114)

References (27)
  • 1
    • 0033213842 scopus 로고    scopus 로고
    • Evaluation of a testing method for the fatigue performance of total knee tibial trays
    • Ahir S.P., Blunn G.W., Haider H., and Walker P.S. Evaluation of a testing method for the fatigue performance of total knee tibial trays. Journal of Biomechanics 32 (1999) 1049-1057
    • (1999) Journal of Biomechanics , vol.32 , pp. 1049-1057
    • Ahir, S.P.1    Blunn, G.W.2    Haider, H.3    Walker, P.S.4
  • 2
    • 34249946565 scopus 로고    scopus 로고
    • ASTM F1800-04. Standard test method for cyclic fatigue testing of metal tibial tray components of total knee joint replacements. Annual Book of ASTM Standards, vol. 13.01.
  • 3
    • 4644244730 scopus 로고    scopus 로고
    • 2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty. Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties
    • Banks S.A., and Hodge W.A. 2003 Hap Paul Award Paper of the International Society for Technology in Arthroplasty. Design and activity dependence of kinematics in fixed and mobile-bearing knee arthroplasties. Journal of Arthroplasty 19 (2004) 809-816
    • (2004) Journal of Arthroplasty , vol.19 , pp. 809-816
    • Banks, S.A.1    Hodge, W.A.2
  • 4
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann G., Graichen F., and Rohlmann A. Hip joint loading during walking and running, measured in two patients. Journal of Biomechanics 26 (1993) 969-990
    • (1993) Journal of Biomechanics , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 10
    • 85119385168 scopus 로고    scopus 로고
    • Dennis, D.A., Komistek, R.D., Mahfouz, M.R., Haas, B.D., Stiehl, J.B., 2003. Multicenter determination of in vivo kinematics after total knee arthroplasty. Clinical Orthopaedics and Related Research, 37-57.
  • 11
    • 34249934964 scopus 로고    scopus 로고
    • Graichen, F., Arnold, R., Rohlmann, A., Bergmann G., in press. Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants. IEEE Transactions on Bio-Medical Engineering.
  • 12
    • 34249935194 scopus 로고    scopus 로고
    • Heinlein, B., Frei, S., Ploeg, H, Buergi, M., 1999. The physiological tibia test. In: Proceedings of the XVIIth meeting of the International Society of Biomechanics, Calgary, Canada.
  • 13
    • 34249938765 scopus 로고    scopus 로고
    • Heinlein, B., Rohlmann, A., Graichen, F., Bergmann, G., 2006. Accuracy of an instrumented total knee arthroplasty for six-component in vivo load measurements. Transactions of the 52rd Annual Meeting of the Orthopedic Research Society, Chicago, IL, p. 605.
  • 14
    • 34249950026 scopus 로고    scopus 로고
    • ISO 14879-1. Implants for surgery-total knee-joint prostheses, Part 1: determination of endurance properties of knee tibial trays. ISO 14879-1.
  • 17
    • 0036017396 scopus 로고    scopus 로고
    • Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements
    • Kurtz S.M., Villarraga M.L., Herr M.P., Bergstrom J.S., Rimnac C.M., and Edidin A.A. Thermomechanical behavior of virgin and highly crosslinked ultra-high molecular weight polyethylene used in total joint replacements. Biomaterials 23 (2002) 3681-3697
    • (2002) Biomaterials , vol.23 , pp. 3681-3697
    • Kurtz, S.M.1    Villarraga, M.L.2    Herr, M.P.3    Bergstrom, J.S.4    Rimnac, C.M.5    Edidin, A.A.6
  • 18
    • 85118902695 scopus 로고    scopus 로고
    • Moreland, J.R., 1988. Mechanisms of failure in total knee arthroplasty. Clinical Orthopaedics and Related Research, 49-64.
  • 19
    • 0014808492 scopus 로고
    • The mechanics of muscle function in locomotion
    • Morrison J.B. The mechanics of muscle function in locomotion. Journal of Biomechanics 3 (1970) 431-451
    • (1970) Journal of Biomechanics , vol.3 , pp. 431-451
    • Morrison, J.B.1
  • 21
    • 27644448756 scopus 로고    scopus 로고
    • Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene
    • Ries M.D., and Pruitt L. Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clinical Orthopaedics and Related Research 440 (2005) 149-156
    • (2005) Clinical Orthopaedics and Related Research , vol.440 , pp. 149-156
    • Ries, M.D.1    Pruitt, L.2
  • 23
    • 0016474546 scopus 로고
    • The prediction of muscular load sharing and joint forces in the lower extremities during walking
    • Seireg A., and Arvikar. The prediction of muscular load sharing and joint forces in the lower extremities during walking. Journal of Biomechanics 8 (1975) 89-102
    • (1975) Journal of Biomechanics , vol.8 , pp. 89-102
    • Seireg, A.1    Arvikar2
  • 24
    • 0033119098 scopus 로고    scopus 로고
    • In vitro forces in the normal and cruciate-deficient knee during simulated squatting motion
    • Singerman R., Berilla J., Archdeacon M., and Peyser A. In vitro forces in the normal and cruciate-deficient knee during simulated squatting motion. Journal of Biomechanical Engineering 121 (1999) 234-242
    • (1999) Journal of Biomechanical Engineering , vol.121 , pp. 234-242
    • Singerman, R.1    Berilla, J.2    Archdeacon, M.3    Peyser, A.4
  • 25
    • 0034988888 scopus 로고    scopus 로고
    • Forces and moments telemetered from two distal femoral replacements during various activities
    • Taylor S.J., and Walker P.S. Forces and moments telemetered from two distal femoral replacements during various activities. Journal of Biomechanics 34 (2001) 839-848
    • (2001) Journal of Biomechanics , vol.34 , pp. 839-848
    • Taylor, S.J.1    Walker, P.S.2
  • 26
    • 85119097227 scopus 로고    scopus 로고
    • Walker, P.S., Blunn, G.W., Perry, J.P., Bell, C.J., Sathasivam, S., Andriacchi, T.P., Paul, J.P., Haider, H., Campbell, P.A., 2000. Methodology for long-term wear testing of total knee replacements. Clinical Orthopaedics and Related Research, 290-301.
  • 27
    • 29344471818 scopus 로고    scopus 로고
    • Fatigue resistance analysis of tibial baseplate in total knee prosthesis-an in vitro biomechanical study
    • Yu T.C., Huang C.H., Hsieh C.H., Liau J.J., Huang C.H., and Cheng C.K. Fatigue resistance analysis of tibial baseplate in total knee prosthesis-an in vitro biomechanical study. Clinical biomechanics 21 (2006) 147-151
    • (2006) Clinical biomechanics , vol.21 , pp. 147-151
    • Yu, T.C.1    Huang, C.H.2    Hsieh, C.H.3    Liau, J.J.4    Huang, C.H.5    Cheng, C.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.