메뉴 건너뛰기




Volumn 25, Issue 2 SUPPL., 2011, Pages

Far cortical locking enables flexible fixation with periarticular locking plates

Author keywords

biomechanics; femur; locking plate; osteosynthesis; supercondylar fracture

Indexed keywords

ARTICLE; BIOMECHANICS; DIAPHYSIS; FAR CORTICAL LOCKING; FEMUR DISTAL FRACTURE; FEMUR FRACTURE; FLEXIBLE FIXATION; FRACTURE FIXATION; FRACTURE TREATMENT; HUMAN; OSTEOSYNTHESIS; PERIARTICULAR LOCKING PLATE; PRIORITY JOURNAL; PROSTHESIS; RIGIDITY;

EID: 79551565253     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3182070cda     Document Type: Article
Times cited : (63)

References (27)
  • 2
    • 77955076197 scopus 로고    scopus 로고
    • Far cortical locking can improve healing of fractures stabilized with locking plates
    • Bottlang M, Lesser M, Koerber J, et al. Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg Am. 2010;92:1652-1660.
    • (2010) J. Bone Joint Surg. Am. , vol.92 , pp. 1652-1660
    • Bottlang, M.1    Lesser, M.2    Koerber, J.3
  • 3
    • 64549084632 scopus 로고    scopus 로고
    • Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes
    • Henderson CE, Bottlang M, Marsh JL, et al. Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes. Iowa Orthop J. 2008;28:73-76.
    • (2008) Iowa Orthop. J. , vol.28 , pp. 73-76
    • Henderson, C.E.1    Bottlang, M.2    Marsh, J.L.3
  • 4
    • 77649143635 scopus 로고    scopus 로고
    • Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation
    • Lujan TJ, Henderson CE, Madey SM, et al. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation. J Orthop Trauma. 2010;24:156-162.
    • (2010) J. Orthop. Trauma. , vol.24 , pp. 156-162
    • Lujan, T.J.1    Henderson, C.E.2    Madey, S.M.3
  • 5
    • 33645313740 scopus 로고    scopus 로고
    • Internal plate fixation of fractures: Short history and recent developments
    • Uhthoff HK, Poitras P, Backman DS. Internal plate fixation of fractures: short history and recent developments. J Orthop Sci. 2006;11:118-126.
    • (2006) J. Orthop. Sci. , vol.11 , pp. 118-126
    • Uhthoff, H.K.1    Poitras, P.2    Backman, D.S.3
  • 6
    • 77954675902 scopus 로고    scopus 로고
    • The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness
    • Dobele S, Horn C, Eichhorn S, et al. The dynamic locking screw (DLS) can increase interfragmentary motion on the near cortex of locked plating constructs by reducing the axial stiffness. Langenbecks Arch Surg. 2010;395:421-428.
    • (2010) Langenbecks Arch. Surg. , vol.395 , pp. 421-428
    • Dobele, S.1    Horn, C.2    Eichhorn, S.3
  • 7
    • 77952105266 scopus 로고    scopus 로고
    • Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots
    • Gardner MJ, Nork SE, Huber P, et al. Less rigid stable fracture fixation in osteoporotic bone using locked plates with near cortical slots. Injury. 2010;41:652-656.
    • (2010) Injury , vol.41 , pp. 652-656
    • Gardner, M.J.1    Nork, S.E.2    Huber, P.3
  • 8
    • 0142168925 scopus 로고    scopus 로고
    • Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled?
    • Stoffel K, Dieter U, Stachowiak G, et al. Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11-B19.
    • (2003) Injury , vol.34 , Issue.2 SUPPL.
    • Stoffel, K.1    Dieter, U.2    Stachowiak, G.3
  • 9
    • 68349151202 scopus 로고    scopus 로고
    • Far cortical locking can reduce the stiffness of locked plating constructs while retaining construct strength
    • Bottlang M, Doornink J, Fitzpatrick DC, et al. Far cortical locking can reduce the stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91:1985-1994.
    • (2009) J. Bone Joint Surg. Am. , vol.91 , pp. 1985-1994
    • Bottlang, M.1    Doornink, J.2    Fitzpatrick, D.C.3
  • 10
    • 33748965764 scopus 로고    scopus 로고
    • The effect of plate rotation on the stiffness of femoral LISS: A mechanical study
    • Khalafi A, Curtiss S, Hazelwood S, et al. The effect of plate rotation on the stiffness of femoral LISS: a mechanical study. J Orthop Trauma. 2006;20:542-546.
    • (2006) J. Orthop. Trauma. , vol.20 , pp. 542-546
    • Khalafi, A.1    Curtiss, S.2    Hazelwood, S.3
  • 11
    • 0035261243 scopus 로고    scopus 로고
    • Mechanical comparison of endosteal substitution and lateral plate fixation in supracondylar fractures of the femur
    • Prayson MJ, Datta DK, Marshall MP. Mechanical comparison of endosteal substitution and lateral plate fixation in supracondylar fractures of the femur. J Orthop Trauma. 2001;15:96-100.
    • (2001) J. Orthop. Trauma. , vol.15 , pp. 96-100
    • Prayson, M.J.1    Datta, D.K.2    Marshall, M.P.3
  • 12
    • 4644224564 scopus 로고    scopus 로고
    • Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures
    • Zlowodzki M, Williamson S, Cole PA, et al. Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for the internal fixation of distal femur fractures. J Orthop Trauma. 2004;18:494-502.
    • (2004) J. Orthop. Trauma. , vol.18 , pp. 494-502
    • Zlowodzki, M.1    Williamson, S.2    Cole, P.A.3
  • 13
    • 0034252016 scopus 로고    scopus 로고
    • Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail
    • Meyer RW, Plaxton NA, Postak PD, et al. Mechanical comparison of a distal femoral side plate and a retrograde intramedullary nail. J Orthop Tauma. 2000;14:398-404.
    • (2000) J. Orthop. Tauma , vol.14 , pp. 398-404
    • Meyer, R.W.1    Plaxton, N.A.2    Postak, P.D.3
  • 14
    • 0034984126 scopus 로고    scopus 로고
    • Hip contact forces and gait patterns from routine activities
    • Bergmann G, Deuretzbacher G, Heller M, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859-871.
    • (2001) J. Biomech. , vol.34 , pp. 859-871
    • Bergmann, G.1    Deuretzbacher, G.2    Heller, M.3
  • 16
    • 58149394984 scopus 로고    scopus 로고
    • Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison
    • Wilkens KJ, Curtiss S, Lee MA. Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison. J Orthop Trauma. 2008;22:624-628.
    • (2008) J. Orthop. Trauma. , vol.22 , pp. 624-628
    • Wilkens, K.J.1    Curtiss, S.2    Lee, M.A.3
  • 17
    • 70349728914 scopus 로고    scopus 로고
    • Biomechanical comparison of polyaxialtype locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures
    • Otto RJ, Moed BR, Bledsoe JG. Biomechanical comparison of polyaxialtype locking plates and a fixed-angle locking plate for internal fixation of distal femur fractures. J Orthop Trauma. 2009;23:645-652.
    • (2009) J. Orthop. Trauma. , vol.23 , pp. 645-652
    • Otto, R.J.1    Moed, B.R.2    Bledsoe, J.G.3
  • 18
    • 0029411951 scopus 로고
    • Comparison of the mechanical performance of three types of external fixators: Linear, circular and hybrid
    • Caja V, Kim W, Larsson S, et al. Comparison of the mechanical performance of three types of external fixators: linear, circular and hybrid. Clin Biomech (Bristol, Avon). 1995;10:401-406.
    • (1995) Clin. Biomech. (Bristol, Avon) , vol.10 , pp. 401-406
    • Caja, V.1    Kim, W.2    Larsson, S.3
  • 19
    • 0023223318 scopus 로고
    • Stability of ten configurations of the Hoffmann external-fixation frame
    • Finlay JB, Moroz TK, Rorabeck CH, et al. Stability of ten configurations of the Hoffmann external-fixation frame. J Bone Joint Surg Am. 1987;69:734-744.
    • (1987) J. Bone Joint Surg. Am. , vol.69 , pp. 734-744
    • Finlay, J.B.1    Moroz, T.K.2    Rorabeck, C.H.3
  • 20
    • 0024253927 scopus 로고
    • External skeletal fixation: Choosing a system based on biomechanical stability
    • Moroz TK, Finlay JB, Rorabeck CH, et al. External skeletal fixation: choosing a system based on biomechanical stability. J Orthop Trauma. 1988;2:284-296.
    • (1988) J. Orthop. Trauma. , vol.2 , pp. 284-296
    • Moroz, T.K.1    Finlay, J.B.2    Rorabeck, C.H.3
  • 21
    • 0036789284 scopus 로고    scopus 로고
    • Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty
    • Bong MR, Egol KA, Koval KJ, et al. Comparison of the LISS and a retrograde-inserted supracondylar intramedullary nail for fixation of a periprosthetic distal femur fracture proximal to a total knee arthroplasty. J Arthroplasty. 2002;17:876-881.
    • (2002) J. Arthroplasty , vol.17 , pp. 876-881
    • Bong, M.R.1    Egol, K.A.2    Koval, K.J.3
  • 22
    • 58649101626 scopus 로고    scopus 로고
    • Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis
    • Fitzpatrick DC, Doornink J, Madey SM, et al. Relative stability of conventional and locked plating fixation in a model of the osteoporotic femoral diaphysis. Clin Biomech (Bristol, Avon). 2009;24:203-209.
    • (2009) Clin. Biomech. (Bristol, Avon) , vol.24 , pp. 203-209
    • Fitzpatrick, D.C.1    Doornink, J.2    Madey, S.M.3
  • 23
    • 34447302029 scopus 로고    scopus 로고
    • Biomechanical considerations in plate osteosynthesis: The effect of plate-to-bone compression with and without angular screw stability
    • Stoffel K, Lorenz KU, Kuster MS. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability. J Orthop Trauma. 2007;21:362-368.
    • (2007) J. Orthop. Trauma. , vol.21 , pp. 362-368
    • Stoffel, K.1    Lorenz, K.U.2    Kuster, M.S.3
  • 25
    • 0022413393 scopus 로고
    • The influence of induced micromovement upon the healing of experimental tibial fractures
    • Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg Br. 1985;67:650-655.
    • (1985) J. Bone Joint Surg. Br. , vol.67 , pp. 650-655
    • Goodship, A.E.1    Kenwright, J.2
  • 26
    • 0025807515 scopus 로고
    • Axial movement and tibial fractures. A controlled randomised trial of treatment
    • Kenwright J, Richardson JB, Cunningham JL, et al. Axial movement and tibial fractures. A controlled randomised trial of treatment. J Bone Joint Surg Br. 1991;73:654-659.
    • (1991) J. Bone Joint Surg. Br. , vol.73 , pp. 654-659
    • Kenwright, J.1    Richardson, J.B.2    Cunningham, J.L.3
  • 27
    • 62549115765 scopus 로고    scopus 로고
    • A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis
    • Bottlang M, Doornink J, Byrd GD, et al. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis. J Bone Joint Surg Am. 2009;91:620-627.
    • (2009) J. Bone Joint Surg. Am. , vol.91 , pp. 620-627
    • Bottlang, M.1    Doornink, J.2    Byrd, G.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.