메뉴 건너뛰기




Volumn 14, Issue 4-5, 2006, Pages 321-333

Clinical experiences with ultrasonometric measurement of fracture healing

Author keywords

Assessment; Cortical bone; Fracture healing; Monitoring; Quantitative ultrasound; Ultrasonometry

Indexed keywords

ARTICLE; CALLUS; DEVICE; DIAPHYSIS; FRACTURE; FRACTURE HEALING; HUMAN; HUMAN TISSUE; LONG BONE; PRIORITY JOURNAL; TRANSDUCER; ULTRASOUND; VALIDATION PROCESS;

EID: 33750263731     PISSN: 09287329     EISSN: None     Source Type: Journal    
DOI: 10.3233/thc-2006-144-514     Document Type: Article
Times cited : (11)

References (104)
  • 1
    • 0015324860 scopus 로고
    • Ultrasonics and physical properties of healing bone
    • W.F. Abendschein and G.W. Hyatt, Ultrasonics and physical properties of healing bone, J Trauma 12(4) (1972), 297-301.
    • (1972) J Trauma , vol.12 , Issue.4 , pp. 297-301
    • Abendschein, W.F.1    Hyatt, G.W.2
  • 2
    • 0032191944 scopus 로고    scopus 로고
    • A portable monitoring system for measuring weight-bearing during tibial fracture healing
    • P.J. Aranzulla, D.S. Muckle and J.L. Cunningham, A portable monitoring system for measuring weight-bearing during tibial fracture healing, Med Eng Phys 20(7) (1998), 543-548.
    • (1998) Med Eng Phys , vol.20 , Issue.7 , pp. 543-548
    • Aranzulla, P.J.1    Muckle, D.S.2    Cunningham, J.L.3
  • 3
    • 0024892801 scopus 로고
    • Anatomical variation of orthotropic elastic moduli of the proximal human tibia
    • R. Ashman, J. Rho and C. Turner, Anatomical variation of orthotropic elastic moduli of the proximal human tibia, J Biomech 22 (1989), 895-900.
    • (1989) J Biomech , vol.22 , pp. 895-900
    • Ashman, R.1    Rho, J.2    Turner, C.3
  • 4
    • 0021213283 scopus 로고
    • A continuous wave technique for the measurement of the elastic properties of cortical bone
    • R.B. Ashman, S.C. Cowin, W.C. van Buskirk and J.C. Rice, A continuous wave technique for the measurement of the elastic properties of cortical bone, J Biomech 17 (1984), 349-361.
    • (1984) J Biomech , vol.17 , pp. 349-361
    • Ashman, R.B.1    Cowin, S.C.2    Van Buskirk, W.C.3    Rice, J.C.4
  • 5
    • 0031032220 scopus 로고    scopus 로고
    • Quantitative assessment of experimental fracture repair by peripheral computed tomography
    • P. Augat, J. Merk, H.K. Genant and L. Claes, Quantitative assessment of experimental fracture repair by peripheral computed tomography, Calcif Tissue Int 60(2) (1997), 194-199.
    • (1997) Calcif Tissue Int , vol.60 , Issue.2 , pp. 194-199
    • Augat, P.1    Merk, J.2    Genant, H.K.3    Claes, L.4
  • 6
    • 0033986191 scopus 로고    scopus 로고
    • Scintigraphic evaluation of tibial shaft fracture healing
    • J.W. Barros, C.H. Barbieri and C.D. Fernandes, Scintigraphic evaluation of tibial shaft fracture healing, Injury 31(1) (2000), 51-54.
    • (2000) Injury , vol.31 , Issue.1 , pp. 51-54
    • Barros, J.W.1    Barbieri, C.H.2    Fernandes, C.D.3
  • 7
    • 0019393964 scopus 로고
    • Ultrasound propagation in in vivo bone
    • J. Behari and S. Singh, Ultrasound propagation in in vivo bone, Ultrasonics 19(2) (1981), 87-90.
    • (1981) Ultrasonics , vol.19 , Issue.2 , pp. 87-90
    • Behari, J.1    Singh, S.2
  • 9
    • 0020004785 scopus 로고
    • Ultrasonic analysis of the Young's modulus of cortical bone
    • W. Bonfield and A.E. Tully, Ultrasonic analysis of the Young's modulus of cortical bone, J Biomed Eng 4 (1982), 23-27.
    • (1982) J Biomed Eng , vol.4 , pp. 23-27
    • Bonfield, W.1    Tully, A.E.2
  • 10
    • 0020360962 scopus 로고
    • Resonance of the human tibia. Method, reproducibility and effect of transection
    • A. Borgwardt Christensen, L. Tougaard, C. Dyrbye and H. Vibe-Hansen, Resonance of the human tibia. Method, reproducibility and effect of transection, Acta Orthop Scand 53(6) (1982), 867-874.
    • (1982) Acta Orthop Scand , vol.53 , Issue.6 , pp. 867-874
    • Borgwardt Christensen, A.1    Tougaard, L.2    Dyrbye, C.3    Vibe-Hansen, H.4
  • 11
    • 0030140892 scopus 로고    scopus 로고
    • Bone callus: Possible assessment with color Doppler ultrasonography, Normal bone healing process
    • (Italian)
    • O. Bottinelli, F. Calliada and R. Campani, [Bone callus: possible assessment with color Doppler ultrasonography, Normal bone healing process] Radiol Med (Torino) 91(5) (1996), 537-541. (Italian)
    • (1996) Radiol Med (Torino) , vol.91 , Issue.5 , pp. 537-541
    • Bottinelli, O.1    Calliada, F.2    Campani, R.3
  • 12
    • 0346333123 scopus 로고    scopus 로고
    • Effect of COX-2-specific inhibition on fracture-healing in the rat femur
    • K.M. Brown, M.M. Saunders, T. Kirsch, H.J. Donahue and J.S. Reid, Effect of COX-2-specific inhibition on fracture-healing in the rat femur, J Bone Joint Surg Am 86-A(1) (2004), 116-123.
    • (2004) J Bone Joint Surg Am , vol.86 A , Issue.1 , pp. 116-123
    • Brown, K.M.1    Saunders, M.M.2    Kirsch, T.3    Donahue, H.J.4    Reid, J.S.5
  • 13
    • 0018137364 scopus 로고
    • Mechanical properties and composition of cortical bone
    • D. Carter and D. Spengler, Mechanical properties and composition of cortical bone, Clin Orthop Rel Res 135 (1978), 192-217.
    • (1978) Clin Orthop Rel Res , vol.135 , pp. 192-217
    • Carter, D.1    Spengler, D.2
  • 16
    • 0031032888 scopus 로고    scopus 로고
    • Clinical implications of stiffness and strength changes in fracture healing
    • M.J. Chehade, A.P. Pohl, M.J. Pearcy and N. Nawana, Clinical implications of stiffness and strength changes in fracture healing, J Bone Joint Surg Br 79(1) (1997), 9-12.
    • (1997) J Bone Joint Surg Br , vol.79 , Issue.1 , pp. 9-12
    • Chehade, M.J.1    Pohl, A.P.2    Pearcy, M.J.3    Nawana, N.4
  • 18
    • 0023434280 scopus 로고
    • Non-invasive method of measuring resonant frequency of a human tibia in vivo. Part 1
    • R.J. Collier and R.J. Donarski, Non-invasive method of measuring resonant frequency of a human tibia in vivo. Part 1, J Biomed Eng 9(4) (1987), 321-328.
    • (1987) J Biomed Eng , vol.9 , Issue.4 , pp. 321-328
    • Collier, R.J.1    Donarski, R.J.2
  • 19
    • 0023434286 scopus 로고
    • Non-invasive method of measuring the resonant frequency of a human tibia in vivo. Part 2
    • R.J. Collier and R.J. Donarski, Non-invasive method of measuring the resonant frequency of a human tibia in vivo. Part 2, J Biomed Eng 9(4) (1987), 329-331.
    • (1987) J Biomed Eng , vol.9 , Issue.4 , pp. 329-331
    • Collier, R.J.1    Donarski, R.J.2
  • 20
    • 0023222205 scopus 로고
    • Assessment of tibial stiffness by vibration testing in situ: III. Sensitivity of different modes and interpretation of vibration measurements
    • M. Cornelissen, P. Cornelissen, G. van der Perre, A.B. Christensen, F. Ammitzboll and C. Dyrbye, Assessment of tibial stiffness by vibration testing in situ: III. Sensitivity of different modes and interpretation of vibration measurements, J Biomech 20 (1987), 333-342.
    • (1987) J Biomech , vol.20 , pp. 333-342
    • Cornelissen, M.1    Cornelissen, P.2    Van Der Perre, G.3    Christensen, A.B.4    Ammitzboll, F.5    Dyrbye, C.6
  • 21
    • 0015593173 scopus 로고
    • Measurement of the velocity of ultrasound in human cortical bone and its potential clinical importance. An in vivo preliminary study
    • J.D. Craven, M.A. Costantini, M.A. Greenfield and R. Stern, Measurement of the velocity of ultrasound in human cortical bone and its potential clinical importance. An in vivo preliminary study, Invest Radiol 8(2) (1973), 72-77.
    • (1973) Invest Radiol , vol.8 , Issue.2 , pp. 72-77
    • Craven, J.D.1    Costantini, M.A.2    Greenfield, M.A.3    Stern, R.4
  • 24
    • 17144458728 scopus 로고    scopus 로고
    • New concepts of monitoring and assessment of bone union stiffness in fractures treated by Dynastab DK external fixation
    • (Pol.)
    • J. Deszczynski, [New concepts of monitoring and assessment of bone union stiffness in fractures treated by Dynastab DK external fixation], Chir Narzadow Ruchu Ortop Pol 64(6) (1999), 649-656. (Pol.)
    • (1999) Chir Narzadow Ruchu Ortop Pol , vol.64 , Issue.6 , pp. 649-656
    • Deszczynski, J.1
  • 26
    • 0019993210 scopus 로고
    • Influence of age on mechanical properties of healing fractures and intact bones in rats
    • A. Ekeland, L.B. Engesoeter and N. Langeland, Influence of age on mechanical properties of healing fractures and intact bones in rats, Acta Orthop Scand 53(4) (1982), 527-534.
    • (1982) Acta Orthop Scand , vol.53 , Issue.4 , pp. 527-534
    • Ekeland, A.1    Engesoeter, L.B.2    Langeland, N.3
  • 27
    • 0025045772 scopus 로고
    • Ultrasonic attenuation and velocity in bone
    • J.A. Evans and M.B. Tavakoli, Ultrasonic attenuation and velocity in bone, Phys Med Biol 35(10) (1990), 1387-1396.
    • (1990) Phys Med Biol , vol.35 , Issue.10 , pp. 1387-1396
    • Evans, J.A.1    Tavakoli, M.B.2
  • 28
    • 0029005626 scopus 로고
    • Bone loss after tibial fracture: Evaluated by dual-energy x-ray absorptiometry
    • K.S. Eyres and J.A. Kanis, Bone loss after tibial fracture: Evaluated by dual-energy x-ray absorptiometry, J Bone Jt Surg 77-B (1995), 473-478.
    • (1995) J Bone Jt Surg , vol.77 B , pp. 473-478
    • Eyres, K.S.1    Kanis, J.A.2
  • 29
    • 0028326612 scopus 로고
    • Early detection of delayed union in lower leg fractures using computerised analysis of mechanical vibration reactions of bone for assessing the state of fracture healing
    • M. Fellinger, N. Leitgeb, R. Szyszkowitz, G. Peicha, J. Passler, W. Seggl and A. Schanner, Early detection of delayed union in lower leg fractures using computerised analysis of mechanical vibration reactions of bone for assessing the state of fracture healing, Acta Orthop Trauma Surg 113 (1994), 93-96.
    • (1994) Acta Orthop Trauma Surg , vol.113 , pp. 93-96
    • Fellinger, M.1    Leitgeb, N.2    Szyszkowitz, R.3    Peicha, G.4    Passler, J.5    Seggl, W.6    Schanner, A.7
  • 30
    • 0028886520 scopus 로고
    • Quantitative ultrasound of the tibia: A novel approach for assessment of bone status
    • A.J. Foldes, A. Rimon, D.D. Keinan and M.M. Popovtzer, Quantitative ultrasound of the tibia: a novel approach for assessment of bone status, Bone 17(4) (1995), 363-367.
    • (1995) Bone , vol.17 , Issue.4 , pp. 363-367
    • Foldes, A.J.1    Rimon, A.2    Keinan, D.D.3    Popovtzer, M.M.4
  • 34
    • 33750266447 scopus 로고    scopus 로고
    • Ultrasonic methods for compact bone of long bones evaluation in experimental and clinical settings
    • 141-143. (pol.)
    • W. Glinkowski, T. Jȩdral, M. Kornacki and A. Latuszek, [Ultrasonic methods for compact bone of long bones evaluation in experimental and clinical settings], Acta Bio-Opt Inform Med 3 (1997), 2-4, 141-143. (pol.)
    • (1997) Acta Bio-Opt Inform Med , vol.3 , pp. 2-4
    • Glinkowski, W.1    Jȩdral, T.2    Kornacki, M.3    Latuszek, A.4
  • 35
    • 33750240644 scopus 로고    scopus 로고
    • Evaluation method of long bones compact tissue for parametric assessment of fracture healing in preliminary clinical studies
    • 23-26. (pol.)
    • W. Glinkowski, T. Jȩdral, M. Kornacki and A. Latuszek, [Evaluation method of long bones compact tissue for parametric assessment of fracture healing in preliminary clinical studies], Medycyna Sportowa 13 (1997), 11, 23-26. (pol.)
    • (1997) Medycyna Sportowa , vol.13 , pp. 11
    • Glinkowski, W.1    Jȩdral, T.2    Kornacki, M.3    Latuszek, A.4
  • 36
    • 33750268474 scopus 로고    scopus 로고
    • Metod of Ultrasonometric Fractures Healing Evaluation of Long Bones
    • S544. (Abstract SA 069)
    • W. Glinkowski, T. Jȩdral, M. Kornacki and A. Latuszek, Metod of Ultrasonometric Fractures Healing Evaluation Of Long Bones, Bone 23 (1998), 5 (Suppl), S544. (Abstract SA 069)
    • (1998) Bone , vol.23 , Issue.SUPPL. , pp. 5
    • Glinkowski, W.1    Jȩdral, T.2    Kornacki, M.3    Latuszek, A.4
  • 37
    • 33750262226 scopus 로고    scopus 로고
    • Relative Optical Density Image Analysis (RODIA©) of digitized radiograms for tibial fracture healing monitoring
    • W. Glinkowski, M. Kornacki, M. Ambroziak and A. Górecki, Relative Optical Density Image Analysis (RODIA©) of digitized radiograms for tibial fracture healing monitoring, International Congress Series 1268 (2004), 1292.
    • (2004) International Congress Series , vol.1268 , pp. 1292
    • Glinkowski, W.1    Kornacki, M.2    Ambroziak, M.3    Górecki, A.4
  • 38
    • 33750253197 scopus 로고    scopus 로고
    • Fracture healing of long bones monitoring with ultrasonography
    • (Pol.)
    • W. Glinkowski, [Fracture healing of long bones monitoring with ultrasonography], Ortopedia Traumatologia i Rehabilitacja 3 (2000), (Pol.)
    • (2000) Ortopedia Traumatologia I Rehabilitacja , vol.3
    • Glinkowski, W.1
  • 39
    • 33750279531 scopus 로고    scopus 로고
    • Ultrasonometry of compact bone of tibia. Preliminary report
    • W. Glinkowski, A. Czajkowska and T. Jȩdral, Ultrasonometry of compact bone of tibia. Preliminary report, Med Sci Monit 4(Suppl.2) (1998), 125-127.
    • (1998) Med Sci Monit , vol.4 , Issue.SUPPL. 2 , pp. 125-127
    • Glinkowski, W.1    Czajkowska, A.2    Jȩdral, T.3
  • 40
    • 33750277679 scopus 로고    scopus 로고
    • Method and device for fracture callus density measurement located in fractured long bone
    • Polish Patent Nr 180862 15-10
    • W. Glinkowski, Method and device for fracture callus density measurement located in fractured long bone, Polish Patent Nr 180862 (15-10-1996).
    • (1996)
    • Glinkowski, W.1
  • 41
    • 0242362702 scopus 로고    scopus 로고
    • Quantitative and qualitative assessment of closed fracture healing using computed tomography and conventional radiography
    • M. Grigoryan, J.A. Lynch, A.L. Fierlinger, A. Guermazi, B. Fan, D.B. MacLean, A. MacLean and H.K. Genant, Quantitative and qualitative assessment of closed fracture healing using computed tomography and conventional radiography, Acad Radiol 10(11) (2003), 1267-1273.
    • (2003) Acad Radiol , vol.10 , Issue.11 , pp. 1267-1273
    • Grigoryan, M.1    Lynch, J.A.2    Fierlinger, A.L.3    Guermazi, A.4    Fan, B.5    MacLean, D.B.6    MacLean, A.7    Genant, H.K.8
  • 42
    • 0022356132 scopus 로고
    • Accuracy of radiological assessment of tibial shaft fractures in humans
    • R. Hammer, S. Hammerby and B. Lindholm. Accuracy of radiological assessment of tibial shaft fractures in humans, Clin Orth RR 199 (1985), 233-238.
    • (1985) Clin Orth RR , vol.199 , pp. 233-238
    • Hammer, R.1    Hammerby, S.2    Lindholm, B.3
  • 43
    • 0029694046 scopus 로고    scopus 로고
    • The effect of ultrasonically determined anisotropy on longitudinal fracture of cortical bone
    • Proceedings of the Institution of Mechanical Engineers Part H-J
    • S. Han, J. Medige and I. Ziv, The effect of ultrasonically determined anisotropy on longitudinal fracture of cortical bone. Proceedings of the Institution of Mechanical Engineers Part H-J, Engineering in Medicine 210 (1996), 127-129.
    • (1996) Engineering in Medicine , vol.210 , pp. 127-129
    • Han, S.1    Medige, J.2    Ziv, I.3
  • 44
    • 0036892258 scopus 로고    scopus 로고
    • Different kinetics of bone markers in normal and delayed fracture healing of long bones
    • M. Herrmann, D. Klitscher, T. Georg, J. Frank, I. Marzi and W. Herrmann, Different kinetics of bone markers in normal and delayed fracture healing of long bones, Clin Chem 48(12) (2002), 2263-2266.
    • (2002) Clin Chem , vol.48 , Issue.12 , pp. 2263-2266
    • Herrmann, M.1    Klitscher, D.2    Georg, T.3    Frank, J.4    Marzi, I.5    Herrmann, W.6
  • 48
    • 33750233394 scopus 로고    scopus 로고
    • Relative Optical Density Image Analysis (RODIA). Clinical application - Preliminary report of FHM and IEE subsystems usage
    • M. Kornacki and W. Glinkowski, Relative Optical Density Image Analysis (RODIA). Clinical application - preliminary report of FHM and IEE subsystems usage, Med Sci Monit 4(Suppl. 2) (1998), 136-139.
    • (1998) Med Sci Monit , vol.4 , Issue.SUPPL. 2 , pp. 136-139
    • Kornacki, M.1    Glinkowski, W.2
  • 49
    • 0022702807 scopus 로고
    • Ultrasonic wave propagation and attenuation in wet bone
    • R. Lakes, H.S. Yoon and J.L. Katz, Ultrasonic wave propagation and attenuation in wet bone, J Biomed Eng 8(2) (1986), 143-148.
    • (1986) J Biomed Eng , vol.8 , Issue.2 , pp. 143-148
    • Lakes, R.1    Yoon, H.S.2    Katz, J.L.3
  • 50
    • 0025470090 scopus 로고
    • A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone
    • C.M. Langton, A.V. Ali, C.M. Riggs, G.P. Evans and W. Bonfield, A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone, Clin Phys Physiol Meas 11(3) (1990), 243-249.
    • (1990) Clin Phys Physiol Meas , vol.11 , Issue.3 , pp. 243-249
    • Langton, C.M.1    Ali, A.V.2    Riggs, C.M.3    Evans, G.P.4    Bonfield, W.5
  • 51
    • 2942659241 scopus 로고    scopus 로고
    • Feasibility of bone assessment with leaky Lamb waves in bone phantoms and a bovine tibia
    • K.I. Lee and S.W. Yoon, Feasibility of bone assessment with leaky Lamb waves in bone phantoms and a bovine tibia, J Acoust Soc Am 115(6) (2004), 3210-3217.
    • (2004) J Acoust Soc Am , vol.115 , Issue.6 , pp. 3210-3217
    • Lee, K.I.1    Yoon, S.W.2
  • 52
    • 0030804819 scopus 로고    scopus 로고
    • Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
    • S.C. Lee, B.S. Coan and M.L. Bouxsein, Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone, Bone 21 (1997), 119-125.
    • (1997) Bone , vol.21 , pp. 119-125
    • Lee, S.C.1    Coan, B.S.2    Bouxsein, M.L.3
  • 54
    • 0031264061 scopus 로고    scopus 로고
    • Ultrasound of the tibia - Precision error, left versus right sides and correlation with bone mineral density
    • K.H. Leong, Ultrasound of the tibia - precision error, left versus right sides and correlation with bone mineral density, Ann Acad Med Singapore 26 (1997), 747-749.
    • (1997) Ann Acad Med Singapore , vol.26 , pp. 747-749
    • Leong, K.H.1
  • 55
    • 0001488433 scopus 로고
    • The use of auscultatory percussion for the examination of fractures
    • R.K. Lipmann, The use of auscultatory percussion for the examination of fractures, J Bone Joint Surg 14 (1932), 118.
    • (1932) J Bone Joint Surg , vol.14 , pp. 118
    • Lipmann, R.K.1
  • 56
    • 0030221980 scopus 로고    scopus 로고
    • Study of the vibrational behaviour of a healing tibia using finite element modelling
    • G. Lowet, X. Dayuan and G. Van Der Perre, Study of the vibrational behaviour of a healing tibia using finite element modelling, J Biomech 29(8) (1996), 1003-1010.
    • (1996) J Biomech , vol.29 , Issue.8 , pp. 1003-1010
    • Lowet, G.1    Dayuan, X.2    Van Der Perre, G.3
  • 57
    • 0030634499 scopus 로고    scopus 로고
    • In vivo and in vitro measurement of ultrasound velocity in cortical bone
    • G. Lowet and G. van der Perre, In vivo and in vitro measurement of ultrasound velocity in cortical bone, Stud Health Technol Inform 40 (1997), 201-220.
    • (1997) Stud Health Technol Inform , vol.40 , pp. 201-220
    • Lowet, G.1    Van Der Perre, G.2
  • 58
    • 0030271192 scopus 로고    scopus 로고
    • Ultrasound velocity measurement in long bones: Measurement method and simulation of ultrasound wave propagation
    • G. Lowet and G. Van Der Perre, Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation, J Biomech 29(10) (1996), 1255-1262.
    • (1996) J Biomech , vol.29 , Issue.10 , pp. 1255-1262
    • Lowet, G.1    Van Der Perre, G.2
  • 59
    • 0742284131 scopus 로고    scopus 로고
    • Measurement of changes in trabecular bone at fracture sites using X-ray CT and automated image registration and processing
    • J.A. Lynch, M. Grigoryan, A. Fierlinger, A. Guermazi, S. Zaim, D.B. MacLean and H.K. Genant, Measurement of changes in trabecular bone at fracture sites using X-ray CT and automated image registration and processing, J Orthop Res 22(2) (2004), 362-367.
    • (2004) J Orthop Res , vol.22 , Issue.2 , pp. 362-367
    • Lynch, J.A.1    Grigoryan, M.2    Fierlinger, A.3    Guermazi, A.4    Zaim, S.5    MacLean, D.B.6    Genant, H.K.7
  • 60
    • 0027308277 scopus 로고
    • Noninvasive monitoring techniques for quantitative description of callus mineral content and mechanical properties
    • M.D. Markel and E.Y. Chao, Noninvasive monitoring techniques for quantitative description of callus mineral content and mechanical properties, Clin Orthop 293 (1993), 37-45.
    • (1993) Clin Orthop , vol.293 , pp. 37-45
    • Markel, M.D.1    Chao, E.Y.2
  • 61
    • 0023072966 scopus 로고
    • Use of tuning fork in diagnostic auscultation of fractures
    • R.K. Misurya, A. Khare, A. Mallick, A. Sural and G.K. Vishwakarma, Use of tuning fork in diagnostic auscultation of fractures, Injury 18(1) (1987), 63-64.
    • (1987) Injury , vol.18 , Issue.1 , pp. 63-64
    • Misurya, R.K.1    Khare, A.2    Mallick, A.3    Sural, A.4    Vishwakarma, G.K.5
  • 62
    • 0032018133 scopus 로고    scopus 로고
    • Ultrasound for the early diagnosis of tibial fracture healing after static interlocked nailing wthout reaming: Histologic correlation using a canine model
    • B.R. Moed, E.C. Kim, M. van Holsbeeck, M.B. Schaffler, S. Subramanian, J.A. Bouffard and J.G. Craig, Ultrasound for the early diagnosis of tibial fracture healing after static interlocked nailing wthout reaming: histologic correlation using a canine model, J Orthop Trauma 12(3) (1998), 200-205.
    • (1998) J Orthop Trauma , vol.12 , Issue.3 , pp. 200-205
    • Moed, B.R.1    Kim, E.C.2    Van Holsbeeck, M.3    Schaffler, M.B.4    Subramanian, S.5    Bouffard, J.A.6    Craig, J.G.7
  • 63
    • 0032020267 scopus 로고    scopus 로고
    • Ultrasound for the early diagnosis of tibial fracture healing after static interlocked nailing without reaming: Clinical results
    • B.R. Moed, S. Subramanian, M. van Holsbeeck, J.T. Watson, K.E. Cramer, D.E. Karges, J.G. Craig and J.A. Bouffard, Ultrasound for the early diagnosis of tibial fracture healing after static interlocked nailing without reaming: clinical results, J Orthop Trauma 12(3) (1998), 206-213.
    • (1998) J Orthop Trauma , vol.12 , Issue.3 , pp. 206-213
    • Moed, B.R.1    Subramanian, S.2    Van Holsbeeck, M.3    Watson, J.T.4    Cramer, K.E.5    Karges, D.E.6    Craig, J.G.7    Bouffard, J.A.8
  • 64
    • 0028928754 scopus 로고
    • Ultrasound for the early diagnosis of fracture healing after interlocking nailing of the tibia without reaming
    • B.R. Moed, J.T. Watson, P. Goldschmidt and M. van Holsbeeck, Ultrasound for the early diagnosis of fracture healing after interlocking nailing of the tibia without reaming, Clin Orthop 310 (1995), 137-144.
    • (1995) Clin Orthop , vol.310 , pp. 137-144
    • Moed, B.R.1    Watson, J.T.2    Goldschmidt, P.3    Van Holsbeeck, M.4
  • 65
    • 0034754371 scopus 로고    scopus 로고
    • Mechanical properties of callus in human tibial fractures: A preliminary investigation
    • C.I. Moorcroft, P.J. Ogrodnik, P.B. Thomas and R.H. Wade, Mechanical properties of callus in human tibial fractures: a preliminary investigation, Clin Biomech (Bristol, Avon) 16(9) (2001), 776-782.
    • (2001) Clin Biomech (Bristol, Avon) , vol.16 , Issue.9 , pp. 776-782
    • Moorcroft, C.I.1    Ogrodnik, P.J.2    Thomas, P.B.3    Wade, R.H.4
  • 66
    • 0029681729 scopus 로고    scopus 로고
    • Assessment of fracture healing in the tibia using the impulse response method
    • Y. Nakatsuchi, A. Tsuchikane and A. Nomura, Assessment of fracture healing in the tibia using the impulse response method, J Orthop Trauma 10(1) (1996), 50-62.
    • (1996) J Orthop Trauma , vol.10 , Issue.1 , pp. 50-62
    • Nakatsuchi, Y.1    Tsuchikane, A.2    Nomura, A.3
  • 67
    • 0030271425 scopus 로고    scopus 로고
    • The vibrational mode of the tibia and assessment of bone union in experimental fracture healing using the impulse response method
    • Y. Nakatsuchi, A. Tsuchikane and A. Nomura, The vibrational mode of the tibia and assessment of bone union in experimental fracture healing using the impulse response method, Med Eng Phys 18(7) (1996), 575-583.
    • (1996) Med Eng Phys , vol.18 , Issue.7 , pp. 575-583
    • Nakatsuchi, Y.1    Tsuchikane, A.2    Nomura, A.3
  • 68
    • 0025270653 scopus 로고
    • Monitoring of fracture healing by lateral and axial vibration analysis
    • G. Nikiforidis, A. Bezerianos, A. Dimarogonas and C. Sutherland, Monitoring of fracture healing by lateral and axial vibration analysis, J Biomech 23(4) (1990), 323-330.
    • (1990) J Biomech , vol.23 , Issue.4 , pp. 323-330
    • Nikiforidis, G.1    Bezerianos, A.2    Dimarogonas, A.3    Sutherland, C.4
  • 69
    • 0345435953 scopus 로고    scopus 로고
    • The use of quantitative ultrasound to monitor fracture healing: A feasibility study using phantoms
    • C.F. Njeh, J.R. Kearton, D. Hans and C.M. Boivin, The use of quantitative ultrasound to monitor fracture healing: a feasibility study using phantoms, Med Eng Phys 20(10) (1998), 781-786.
    • (1998) Med Eng Phys , vol.20 , Issue.10 , pp. 781-786
    • Njeh, C.F.1    Kearton, J.R.2    Hans, D.3    Boivin, C.M.4
  • 71
    • 0035735543 scopus 로고    scopus 로고
    • A fracture movement monitoring system to aid in the assessment of fracture healing in humans
    • P.J. Ogrodnik, C.I. Moorcroft and P.B. Thomas, A fracture movement monitoring system to aid in the assessment of fracture healing in humans, Proc Inst Mech Eng [H] 215(4) (2001), 405-414.
    • (2001) Proc Inst Mech Eng [H] , vol.215 , Issue.4 , pp. 405-414
    • Ogrodnik, P.J.1    Moorcroft, C.I.2    Thomas, P.B.3
  • 72
    • 0028927874 scopus 로고
    • Monitoring fracture healing with strain gauges: The effect on strain values of strain gauge location on the pin circumference
    • O.O. Oni, M. Capper and C. Soutis, Monitoring fracture healing with strain gauges: the effect on strain values of strain gauge location on the pin circumference, Injury 26(3) (1995), 181-182.
    • (1995) Injury , vol.26 , Issue.3 , pp. 181-182
    • Oni, O.O.1    Capper, M.2    Soutis, C.3
  • 74
    • 84970838536 scopus 로고
    • Time to union in the fractured tibia
    • C.M. Page, Time to union in the fractured tibia, Br Med J 1 (1942), 305.
    • (1942) Br Med J , vol.1 , pp. 305
    • Page, C.M.1
  • 75
    • 0021840008 scopus 로고
    • Correlations of radiographic analysis of healing fractures with strength: A statistical analysis of experimental osteotomies
    • M.M. Panjabi, S.D. Walter, M. Karuda, A.A. White and J.P. Lawson, Correlations of radiographic analysis of healing fractures with strength: a statistical analysis of experimental osteotomies, J Orthop Res 3(2) (1985), 212-218.
    • (1985) J Orthop Res , vol.3 , Issue.2 , pp. 212-218
    • Panjabi, M.M.1    Walter, S.D.2    Karuda, M.3    White, A.A.4    Lawson, J.P.5
  • 76
    • 0022201098 scopus 로고
    • Wave propagation across a bony discontinuity simulating a healing fracture
    • R.R. Pelker and S. Saha, Wave propagation across a bony discontinuity simulating a healing fracture, J Biomech 18(10) (1985), 745-753.
    • (1985) J Biomech , vol.18 , Issue.10 , pp. 745-753
    • Pelker, R.R.1    Saha, S.2
  • 77
    • 0015956006 scopus 로고
    • Mechanical properties of bone as a function of position and orientation
    • M. Pope and J. Outwater, Mechanical properties of bone as a function of position and orientation, J Biomech 7 (1974), 61-66.
    • (1974) J Biomech , vol.7 , pp. 61-66
    • Pope, M.1    Outwater, J.2
  • 78
    • 0023450168 scopus 로고
    • Ultrasound attenuation in biological tissues using a bone transducer
    • S. Ray and J. Behari, Ultrasound attenuation in biological tissues using a bone transducer, Med Biol Eng Comput 25(6) (1987), 689-692.
    • (1987) Med Biol Eng Comput , vol.25 , Issue.6 , pp. 689-692
    • Ray, S.1    Behari, J.2
  • 79
    • 0027551874 scopus 로고
    • Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
    • J.Y. Rho, R.B. Ashman and C.H. Turner, Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements, J Biomech 26 (1993), 111-119.
    • (1993) J Biomech , vol.26 , pp. 111-119
    • Rho, J.Y.1    Ashman, R.B.2    Turner, C.H.3
  • 80
    • 0027318005 scopus 로고
    • Mechanical monitoring of fracture healing using ultrasound imaging
    • L. Ricciardi, A. Perissinotto and M. Dabala, Mechanical monitoring of fracture healing using ultrasound imaging, Clin Orthop Relat Res 293 (1993), 71-76.
    • (1993) Clin Orthop Relat Res , vol.293 , pp. 71-76
    • Ricciardi, L.1    Perissinotto, A.2    Dabala, M.3
  • 82
    • 0026864027 scopus 로고
    • Fracture stiffness measurement in the assessment and management of tibial fractures
    • J.B. Richardson, J. Kenwright and J.L. Cunningham, Fracture stiffness measurement in the assessment and management of tibial fractures, Clin Biomech 7(2) (1992), 75-79.
    • (1992) Clin Biomech , vol.7 , Issue.2 , pp. 75-79
    • Richardson, J.B.1    Kenwright, J.2    Cunningham, J.L.3
  • 83
    • 0030281091 scopus 로고    scopus 로고
    • Ultrasound follow-up of callus distraction of the tibia, Technique, possibilities and limits
    • (German)
    • D. Richter, M.P. Hahn, P.A. Ostermann, C. Josten, A. Ekkernkamp and G. Muhr, Ultrasound follow-up of callus distraction of the tibia, Technique, possibilities and limits, Chirurg 67(11) (1996), 1152-1159. (German)
    • (1996) Chirurg , vol.67 , Issue.11 , pp. 1152-1159
    • Richter, D.1    Hahn, M.P.2    Ostermann, P.A.3    Josten, C.4    Ekkernkamp, A.5    Muhr, G.6
  • 84
    • 0034268763 scopus 로고    scopus 로고
    • Efficacy of monitoring long-bone fracture healing by measurement of either bone stiffness or resonant frequency: Numerical simulation
    • S.G. Roberts and C.R. Steele, Efficacy of monitoring long-bone fracture healing by measurement of either bone stiffness or resonant frequency: numerical simulation, J Orthop Res 18(5) (2000), 691-697.
    • (2000) J Orthop Res , vol.18 , Issue.5 , pp. 691-697
    • Roberts, S.G.1    Steele, C.R.2
  • 85
    • 0029787036 scopus 로고    scopus 로고
    • The effect of fracture and fracture fixation on ultrasonic velocity and attenuation
    • J. Saulgozis, I. Pontaga, G. Lowet and G. Van der Perre, The effect of fracture and fracture fixation on ultrasonic velocity and attenuation, Physiol Meas 17(3) (1996), 201-211.
    • (1996) Physiol Meas , vol.17 , Issue.3 , pp. 201-211
    • Saulgozis, J.1    Pontaga, I.2    Lowet, G.3    Van Der Perre, G.4
  • 86
    • 0029095088 scopus 로고
    • Tibial shaft fracture healing assessment with C.T
    • P. Schnarkowski, Tibial shaft fracture healing assessment with C.T., J Comp Ass Tom 19(5) (1995), 777-781.
    • (1995) J Comp Ass Tom , vol.19 , Issue.5 , pp. 777-781
    • Schnarkowski, P.1
  • 87
    • 0001404956 scopus 로고
    • The determination of fracture healing by measurement of sound velocity across the fracture site
    • I.M. Siegel, G.T. Anast and T. Fields, The determination of fracture healing by measurement of sound velocity across the fracture site, Surgery Gynecology and Obstetrics 107 (1958), 327-332.
    • (1958) Surgery Gynecology and Obstetrics , vol.107 , pp. 327-332
    • Siegel, I.M.1    Anast, G.T.2    Fields, T.3
  • 88
    • 0030228131 scopus 로고    scopus 로고
    • Acoustic assessment of fracture healing. Capabilities and limitations of "a lost art"
    • R.S. Siffert and J.J. Kaufman, Acoustic assessment of fracture healing. Capabilities and limitations of "a lost art", Am J Orthop 25(9) (1996), 614-618.
    • (1996) Am J Orthop , vol.25 , Issue.9 , pp. 614-618
    • Siffert, R.S.1    Kaufman, J.J.2
  • 89
    • 0025500706 scopus 로고
    • A stress wave propagation technique for bone repair study
    • V.R. Singh, V.P. Adya, A. Ahmed and S. Yadav, A stress wave propagation technique for bone repair study, IEEE Trans Biomed Eng 37(10) (1990), 1014-1017.
    • (1990) IEEE Trans Biomed Eng , vol.37 , Issue.10 , pp. 1014-1017
    • Singh, V.R.1    Adya, V.P.2    Ahmed, A.3    Yadav, S.4
  • 90
    • 0024764143 scopus 로고
    • Role of natural frequency of bone as a guide for detection of bone fracture healing
    • V.R. Singh, S. Yadav and V.P. Adya, Role of natural frequency of bone as a guide for detection of bone fracture healing, J Biomed Eng 11(6) (1989), 457-461.
    • (1989) J Biomed Eng , vol.11 , Issue.6 , pp. 457-461
    • Singh, V.R.1    Yadav, S.2    Adya, V.P.3
  • 93
    • 0026676315 scopus 로고
    • The effect of bone structure on ultrasonic attenuation and velocity
    • M.B. Tavakoli and J.A. Evans, The effect of bone structure on ultrasonic attenuation and velocity, Ultrasonics 30(6) (1992), 389-395.
    • (1992) Ultrasonics , vol.30 , Issue.6 , pp. 389-395
    • Tavakoli, M.B.1    Evans, J.A.2
  • 94
    • 0025275595 scopus 로고
    • Quantitative roentgenographic densitometry for assessing fracture healing
    • J.J. Tiedeman, L. Lippiello, J.F. Connolly and B.S. Strates, Quantitative roentgenographic densitometry for assessing fracture healing, Clin Orthop 253 (1990), 279-286.
    • (1990) Clin Orthop , vol.253 , pp. 279-286
    • Tiedeman, J.J.1    Lippiello, L.2    Connolly, J.F.3    Strates, B.S.4
  • 97
    • 0032444844 scopus 로고    scopus 로고
    • Effects of nail rigidity on fracture healing. Strength and mineralisation in rat femoral bone
    • S.E. Utvag and O. Reikeras, Effects of nail rigidity on fracture healing. Strength and mineralisation in rat femoral bone, Arch Orthop Trauma Surg 118(1-2) (1998), 7-13.
    • (1998) Arch Orthop Trauma Surg , vol.118 , Issue.1-2 , pp. 7-13
    • Utvag, S.E.1    Reikeras, O.2
  • 98
    • 0030068851 scopus 로고    scopus 로고
    • In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis
    • G. Van der Perre and G. Lowet, In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis, Bone 18(1 Suppl) (1996), 29S-35S.
    • (1996) Bone , vol.18 , Issue.1 SUPPL.
    • Van Der Perre, G.1    Lowet, G.2
  • 99
    • 0015131137 scopus 로고
    • Measurement of ultrasound velocity in human tissue
    • G.E. Van Venroolj, Measurement of ultrasound velocity in human tissue, Ultrasonics 9(4) (1971), 240-242.
    • (1971) Ultrasonics , vol.9 , Issue.4 , pp. 240-242
    • Van Venroolj, G.E.1
  • 100
    • 0035133885 scopus 로고    scopus 로고
    • Outcome in fracture healing: A review Injury
    • R. Wade and J. Richardson, Outcome in fracture healing: a review Injury, Int. J. Care Injured 32 (2001), 109-114.
    • (2001) Int J Care Injured , vol.32 , pp. 109-114
    • Wade, R.1    Richardson, J.2
  • 101
    • 0026549960 scopus 로고
    • Quantitative early phase scintigraphy in the prediction of healing of tibial fractures
    • A.L. Wallace, R.K. Strachan, A. Blane, J.J. Best and S.P. Hughes, Quantitative early phase scintigraphy in the prediction of healing of tibial fractures, Skeletal Radiol 21(4) (1992), 241-245.
    • (1992) Skeletal Radiol , vol.21 , Issue.4 , pp. 241-245
    • Wallace, A.L.1    Strachan, R.K.2    Blane, A.3    Best, J.J.4    Hughes, S.P.5
  • 102
    • 0034914752 scopus 로고    scopus 로고
    • Prediction of mechanical properties of healing fractures using acoustic emission
    • Y. Watanabe, S. Takai, Y. Arai, N. Yoshino and Y. Hirasawa, Prediction of mechanical properties of healing fractures using acoustic emission, J Orthop Res 19(4) (2001), 548-553.
    • (2001) J Orthop Res , vol.19 , Issue.4 , pp. 548-553
    • Watanabe, Y.1    Takai, S.2    Arai, Y.3    Yoshino, N.4    Hirasawa, Y.5
  • 104
    • 0033660114 scopus 로고    scopus 로고
    • Comparison between standard radiography and spiral CT with 3D reconstruction in the evaluation, classification and management of tibial plateau fractures
    • S. Wicky, P.F. Blaser, C.H. Blanc, P.F. Leyvraz, P. Schnyder and R.A. Meuli, Comparison between standard radiography and spiral CT with 3D reconstruction in the evaluation, classification and management of tibial plateau fractures, Eur Radiol 10(8) (2000), 1227-1232.
    • (2000) Eur Radiol , vol.10 , Issue.8 , pp. 1227-1232
    • Wicky, S.1    Blaser, P.F.2    Blanc, C.H.3    Leyvraz, P.F.4    Schnyder, P.5    Meuli, R.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.