메뉴 건너뛰기




Volumn , Issue , 2007, Pages 89-155

Indicator dilution techniques in cardiovascular quantification

Author keywords

Cardiovascular quantification; Indicator dilution technique

Indexed keywords

BLOOD; BLOOD VESSELS; DIAGNOSIS; DILUTION; MAGNETIC RESONANCE IMAGING; ULTRASONIC APPLICATIONS;

EID: 84967361930     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1142/9789812771377_0004     Document Type: Chapter
Times cited : (2)

References (179)
  • 1
    • 0029153813 scopus 로고
    • The thermodilution method for clinical assesment of cardiac output
    • J. R. C. Jansen, The thermodilution method for clinical assesment of cardiac output, Intensive Care Med. 21 (1995) 691-697.
    • (1995) Intensive Care Med , vol.21 , pp. 691-697
    • Jansen, J.R.C.1
  • 3
    • 0023214879 scopus 로고
    • Contrast Echo Washout Curves from Left Ventricle: Application of basic principles of Indicator-Dilution Theory and calculation of Ejection Fraction
    • D. Rovai, S. E. Nissen, J. Elion, M. Smith, A. L’Abbate, O. L. Kuan and A. N. DeMaria, Contrast Echo Washout Curves from Left Ventricle: Application of basic principles of Indicator-Dilution Theory and calculation of Ejection Fraction, J. Am. Coll. Cardiol. 10 (1987) 125-134.
    • (1987) J. Am. Coll. Cardiol , vol.10 , pp. 125-134
    • Rovai, D.1    Nissen, S.E.2    Elion, J.3    Smith, M.4    L’Abbate, A.5    Kuan, O.L.6    DeMaria, A.N.7
  • 4
    • 0030993038 scopus 로고    scopus 로고
    • Indicator-dilution dispersion models and cardiac output computing methods
    • R. K. Millard, Indicator-dilution dispersion models and cardiac output computing methods, The American Physiological Society 272, 4 (1997) H2004-H2012.
    • (1997) The American Physiological Society , vol.272 , Issue.4 , pp. H2004-H2012
    • Millard, R.K.1
  • 5
    • 0034352159 scopus 로고    scopus 로고
    • Indicator-dilution methods for measuring blood flow, volume and other properties of biological systems: A brief history and memoir
    • K. Zierler, Indicator-dilution methods for measuring blood flow, volume and other properties of biological systems: A brief history and memoir, Annals of Biomedical Engineering, 28 (2000) 836-848.
    • (2000) Annals of Biomedical Engineering , vol.28 , pp. 836-848
    • Zierler, K.1
  • 6
    • 85047680511 scopus 로고
    • Random walk type models for indicator-dilution studies: Comparison of a local density random walk and a first passage times distribution
    • J. M. Bogaard, J. R. C. Jansen, E. A. von Reth, A. Versprille and M. E. Wise, Random walk type models for indicator-dilution studies: Comparison of a local density random walk and a first passage times distribution, Cardiovascular Research 20, 11 (1986) 789-796.
    • (1986) Cardiovascular Research , vol.20 , Issue.11 , pp. 789-796
    • Bogaard, J.M.1    Jansen, J.R.C.2    Von Reth, E.A.3    Versprille, A.4    Wise, M.E.5
  • 7
    • 0020781321 scopus 로고
    • Comparison of a two-compartment model and distributed models for indicator dilution studies
    • E. A. von Reth and J. M. Bogaard, Comparison of a two-compartment model and distributed models for indicator dilution studies, Med. & Biol. Eng. & Comput. 21 (1983) 453-459.
    • (1983) Med. & Biol. Eng. & Comput , vol.21 , pp. 453-459
    • Von Reth, E.A.1    Bogaard, J.M.2
  • 8
    • 0032101113 scopus 로고    scopus 로고
    • A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography
    • X. Chen, K. Q. Schwarz, D. Phillips, S. D. Steinmetz and R. Schlief, A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography, IEEE Trans. on Biomedical Engineering 45, 6 (1998) 754-765.
    • (1998) IEEE Trans. on Biomedical Engineering , vol.45 , Issue.6 , pp. 754-765
    • Chen, X.1    Schwarz, K.Q.2    Phillips, D.3    Steinmetz, S.D.4    Schlief, R.5
  • 11
    • 0034442195 scopus 로고    scopus 로고
    • Levemberg-marquardt estimation for accurate end efficient continuous measurement of cardiac output
    • Chicago, IEEE EMB Society
    • P. S. Hamilton, M. G. Curely and R. M. Aimi, Levemberg-marquardt estimation for accurate end efficient continuous measurement of cardiac output, IEEE EMBS International Conference, Chicago (IEEE EMB Society, 2000), pp. 1954-1957.
    • (2000) IEEE EMBS International Conference , pp. 1954-1957
    • Hamilton, P.S.1    Curely, M.G.2    Aimi, R.M.3
  • 12
    • 0028806018 scopus 로고
    • A new method for analysing indicator dilution curves
    • D. M. Band, R. A. F. Linton and N. W. F. Linton, A new method for analysing indicator dilution curves, Cardiovascular Res. 30 (1995) 930-938.
    • (1995) Cardiovascular Res , vol.30 , pp. 930-938
    • Band, D.M.1    Linton, R.A.F.2    Linton, N.W.F.3
  • 13
    • 0035191091 scopus 로고    scopus 로고
    • Empirical estimators of gamma fits to tracer dilution curves and their technical basis and practical scope
    • A. Lopatatzidis and R. K. Millard, Empirical estimators of gamma fits to tracer dilution curves and their technical basis and practical scope, Physiological Measurements 22 (2001) N1-N5.
    • (2001) Physiological Measurements , vol.22 , pp. N1-N5
    • Lopatatzidis, A.1    Millard, R.K.2
  • 15
    • 0001342827 scopus 로고
    • The random walk problem in relation to the physiology of circulatory mixing
    • C. W. Sheppard and L. J. Savage, The random walk problem in relation to the physiology of circulatory mixing, Phys. Rev. 83 (1951) 489490.
    • (1951) Phys. Rev , vol.83 , pp. 489490
    • Sheppard, C.W.1    Savage, L.J.2
  • 16
    • 84967507114 scopus 로고
    • Tracer dilution curves in cardiology and random walk and lognormal distributions
    • M. E. Wise, Tracer dilution curves in cardiology and random walk and lognormal distributions, Acta Physiol. Pharmacol. Neerl. 14 (1966) 175204.
    • (1966) Acta Physiol. Pharmacol. Neerl , vol.14 , pp. 175204
    • Wise, M.E.1
  • 17
    • 0021163861 scopus 로고
    • Physiological interpretation of skewness of indicator-dilution curves; theoretical considerations and practical application
    • J. M. Bogaard, S. J. Smith, A. Versprille, M. E. Wise and F. Hagemeijer, Physiological interpretation of skewness of indicator-dilution curves; theoretical considerations and practical application, Basic Res. Cardiol. 79 (1984) 479-493.
    • (1984) Basic Res. Cardiol , vol.79 , pp. 479-493
    • Bogaard, J.M.1    Smith, S.J.2    Versprille, A.3    Wise, M.E.4    Hagemeijer, F.5
  • 23
    • 33646128415 scopus 로고    scopus 로고
    • Moment method for the local density random walk model interpolation of ultrasound contrast agent dilution curves
    • Brno, June, EURASIP
    • M. Mischi, A. A. C. M. Kalker and H. H. M. Korsten, Moment method for the local density random walk model interpolation of ultrasound contrast agent dilution curves, 17th International EURASIP Conference BIOSIGNAL 2004 (Brno, June 2004, EURASIP), pp. 33-35.
    • (2004) 17th International EURASIP Conference BIOSIGNAL 2004 , pp. 33-35
    • Mischi, M.1    Kalker, A.A.C.M.2    Korsten, H.H.M.3
  • 24
    • 0033879659 scopus 로고    scopus 로고
    • Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclides, ventriculography and cardiovascular magnetic resonance; are they interchangeable?
    • N. G. Bellenger, M. I. Burgess, S. G. Ray, A. Lahiri, A. J. Coats, J. G. Cleland and D. J. Pennell, Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclides, ventriculography and cardiovascular magnetic resonance; are they interchangeable?, Eur. Heart 21, 16 (2000) 1387-1396.
    • (2000) Eur. Heart , vol.21 , Issue.16 , pp. 1387-1396
    • Bellenger, N.G.1    Burgess, M.I.2    Ray, S.G.3    Lahiri, A.4    Coats, A.J.5    Cleland, J.G.6    Pennell, D.J.7
  • 25
    • 84939082594 scopus 로고
    • Researches on the circulation time and on the influences which affect it
    • G. N. Stewart, Researches on the circulation time and on the influences which affect it, J. Physiology 22 (1897) 159-183.
    • (1897) J. Physiology , vol.22 , pp. 159-183
    • Stewart, G.N.1
  • 26
    • 0001669568 scopus 로고
    • Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to cardiac output
    • W. F. Hamilton, J. W. Moore, J. M. Kinsman and R. G. Spurling, Simultaneous determination of the pulmonary and systemic circulation times in man and of a figure related to cardiac output, Am. J. of Physiology 84 (1928) 338-334.
    • (1928) Am. J. of Physiology , vol.84 , pp. 338
    • Hamilton, W.F.1    Moore, J.W.2    Kinsman, J.M.3    Spurling, R.G.4
  • 27
    • 0034084189 scopus 로고    scopus 로고
    • Relationships between volume and pressure measurements and stroke volume in critically ill patients
    • A. J. G. H. Bindels, J. G. van der Hoeven, A. D. Graafland, J. de Koning and A. E. Meinders, Relationships between volume and pressure measurements and stroke volume in critically ill patients, Crit. Care 4 (2000) 193-199.
    • (2000) Crit. Care , vol.4 , pp. 193-199
    • Bindels, A.J.G.H.1    Van der Hoeven, J.G.2    Graafland, A.D.3    De Koning, J.4    Meinders, A.E.5
  • 28
    • 0028334544 scopus 로고
    • Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery
    • A. Hoeft, B. Schorn and A. Weyland Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery, Anesthesiology 81 (1994) 76-86.
    • (1994) Anesthesiology , vol.81 , pp. 76-86
    • Hoeft, A.1    Schorn, B.2    Weyland, A.3
  • 29
    • 0019807799 scopus 로고
    • Radionuclide determined pulmonary blood volume in ischeamic heart disease
    • W. J. Hannan, J. Vojacek, H. M. Connell, N. G. Dewhurst and A. L. Muir, Radionuclide determined pulmonary blood volume in ischeamic heart disease, Thorax 36, 12 (1981) 922-927.
    • (1981) Thorax , vol.36 , Issue.12 , pp. 922-927
    • Hannan, W.J.1    Vojacek, J.2    Connell, H.M.3    Dewhurst, N.G.4    Muir, A.L.5
  • 30
    • 0033001658 scopus 로고    scopus 로고
    • Comparison between intrathoracic blood volume and cardiac filling pressures in early phase of hemodynamic instability of patients with sepsis and septic shock
    • S. G. Sakka, D. L. Bredle, K. Reinhart and A. Meier-Hellmann, Comparison between intrathoracic blood volume and cardiac filling pressures in early phase of hemodynamic instability of patients with sepsis and septic shock, Journal of Critical Care 14, 2 (1999) 78-83.
    • (1999) Journal of Critical Care , vol.14 , Issue.2 , pp. 78-83
    • Sakka, S.G.1    Bredle, D.L.2    Reinhart, K.3    Meier-Hellmann, A.4
  • 31
    • 0034911132 scopus 로고    scopus 로고
    • Changes in cardiac output and intrathoracic blood volume: A mathematical coupling of data?
    • W. Buhre, S. Kazamaier, H. Sonntag and A. Weyland, Changes in cardiac output and intrathoracic blood volume: A mathematical coupling of data? Acta Anaesthesiol Scand. 45 (2001) 863-867.
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 863-867
    • Buhre, W.1    Kazamaier, S.2    Sonntag, H.3    Weyland, A.4
  • 32
    • 0034773361 scopus 로고    scopus 로고
    • Assessment of intrathoracic blood volume as an indicator of cardiac preload: Single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter
    • C. Wiesenack, C. Prasser, C. Keyl and G. Rodig, Assessment of intrathoracic blood volume as an indicator of cardiac preload: Single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter, Journal of Cardiothoracic and Vascular Anesthesia 15, 5 (2001) 584-588.
    • (2001) Journal of Cardiothoracic and Vascular Anesthesia , vol.15 , Issue.5 , pp. 584-588
    • Wiesenack, C.1    Prasser, C.2    Keyl, C.3    Rodig, G.4
  • 33
    • 0020077911 scopus 로고
    • Pulmonary blood volume ratio response to exercise; a noninvasive determination of exercise-induced changes in pulmonary capillary wedge pressure
    • R. D. Okada, M. D. Osbakken, C. A. Boucher, H. W. Strauss, P. C. Block and G. M. Pohost, Pulmonary blood volume ratio response to exercise; a noninvasive determination of exercise-induced changes in pulmonary capillary wedge pressure, Journal of the American Heart Association 65 (1982) 126-133.
    • (1982) Journal of the American Heart Association , vol.65 , pp. 126-133
    • Okada, R.D.1    Osbakken, M.D.2    Boucher, C.A.3    Strauss, H.W.4    Block, P.C.5    Pohost, G.M.6
  • 35
    • 0035052498 scopus 로고    scopus 로고
    • Determination of total blood volume by indicator dilution: A comparison of mean transit time and mass conservation principle
    • O. Picker, G. Weitasch, T. W. L. Sceeren and J. O. Arnd, Determination of total blood volume by indicator dilution: A comparison of mean transit time and mass conservation principle, Intensive Care Med. 27, 3 (2001) 767-774.
    • (2001) Intensive Care Med , vol.27 , Issue.3 , pp. 767-774
    • Picker, O.1    Weitasch, G.2    Sceeren, T.W.L.3    Arnd, J.O.4
  • 39
    • 0033057996 scopus 로고    scopus 로고
    • Extravascular lung water and intathoracic blood volume: Double versus single indicator dilution technique
    • P. Neumann, Extravascular lung water and intathoracic blood volume: Double versus single indicator dilution technique, Intensive Care Medicine 25 (1999) 216-219.
    • (1999) Intensive Care Medicine , vol.25 , pp. 216-219
    • Neumann, P.1
  • 40
    • 33749743450 scopus 로고
    • The dye dilution method for describing the central circulation: An analysis of factors shaping the time-concentration curves
    • E. V. Newman, M. Merrell, A. Genecin, C. Monge, W. R. Mirror and W. P. Mckeever, The dye dilution method for describing the central circulation: An analysis of factors shaping the time-concentration curves, Circulation 4 (1951) 735-746.
    • (1951) Circulation , vol.4 , pp. 735-746
    • Newman, E.V.1    Merrell, M.2    Genecin, A.3    Monge, C.4    Mirror, W.R.5    McKeever, W.P.6
  • 42
    • 0031339793 scopus 로고    scopus 로고
    • Segmentation of gated spect images for automatic computation of myocardial volume and ejection fraction
    • IEEE
    • P. Brigger, P. Bacharach, A. Aldroubi and M. Unser, Segmentation of gated spect images for automatic computation of myocardial volume and ejection fraction, IEEE Proc. of Int. Conf. on Image Processing. IEEE (1997) 113-116.
    • (1997) IEEE Proc. of Int. Conf. on Image Processing , pp. 113-116
    • Brigger, P.1    Bacharach, P.2    Aldroubi, A.3    Unser, M.4
  • 43
    • 4444381394 scopus 로고    scopus 로고
    • Accurate and reproducible measurement of ventricular volume and ejection fraction by contrast echocardiography
    • S. Malm, S. Frigstad, E. Sagberg, H. Larsson and T. Skjaerpe, Accurate and reproducible measurement of ventricular volume and ejection fraction by contrast echocardiography. J. Am. College of Cardiology 44, 5 (2004) 1030-1035.
    • (2004) J. Am. College of Cardiology , vol.44 , Issue.5 , pp. 1030-1035
    • Malm, S.1    Frigstad, S.2    Sagberg, E.3    Larsson, H.4    Skjaerpe, T.5
  • 44
    • 0035178084 scopus 로고    scopus 로고
    • Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography
    • S. Schalla, E. Nagel, H. Lehmkuhl, A. Bornstedt C. Klein, B. Schnackenburg, U. Schneider and E. Fleck, Comparison of magnetic resonance real-time imaging of left ventricular function with conventional magnetic resonance imaging and echocardiography, Am. J. of Cardiology 87 (2001) 95-99.
    • (2001) Am. J. of Cardiology , vol.87 , pp. 95-99
    • Schalla, S.1    Nagel, E.2    Lehmkuhl, H.3    Bornstedt, A.4    Klein, C.5    Schnackenburg, B.6    Schneider, U.7    Fleck, E.8
  • 45
    • 21644458010 scopus 로고
    • Estimation of residual volume of the ventricle of the dog by two indicator dilution techniques
    • J. P. Holt, Estimation of residual volume of the ventricle of the dog by two indicator dilution techniques, Circ. Res. (1956) 4-181.
    • (1956) Circ. Res , pp. 4-181
    • Holt, J.P.1
  • 47
    • 0027807596 scopus 로고
    • Digital subtraction angiography: Feasibility of densitometric evaluation of left ventricular volumes and comparison to measurements obtained by the monoplane area-length-method
    • IEEE
    • H. Lehmkuhl, T. Machnig, B. Eicker, K. Barth, K. Reynen and K. Bachmann, Digital subtraction angiography: Feasibility of densitometric evaluation of left ventricular volumes and comparison to measurements obtained by the monoplane area-length-method, IEEE Proc. on Computers in Cardiology. IEEE (1993) 29-32.
    • (1993) IEEE Proc. on Computers in Cardiology , pp. 29-32
    • Lehmkuhl, H.1    Machnig, T.2    Eicker, B.3    Barth, K.4    Reynen, K.5    Bachmann, K.6
  • 48
    • 0026150567 scopus 로고
    • Measurement of left ventricular ejection fraction (EF) by densitometry from digital subtraction angiography
    • IEEE
    • T. Machnig, B. Eicker, K. Barth, H. Lehmkuhl and K. Bachmann, Measurement of left ventricular ejection fraction (EF) by densitometry from digital subtraction angiography, IEEE Proc. on Computers in Cardiology. IEEE (1990) 589-592.
    • (1990) IEEE Proc. on Computers in Cardiology , pp. 589-592
    • Machnig, T.1    Eicker, B.2    Barth, K.3    Lehmkuhl, H.4    Bachmann, K.5
  • 49
    • 14044271993 scopus 로고    scopus 로고
    • The quantification of absolute myocardial perfusion in humans by contrast echocardiography, algorithm and validation
    • R. Vogel, A. Indermhle, J. Reinhardt, P. Meier, P. T. Siegrist, M. Namdar and P. A. Kaufmann, The quantification of absolute myocardial perfusion in humans by contrast echocardiography, algorithm and validation, J. Am. College Cardiology 45, 5 (2005) 754-762.
    • (2005) J. Am. College Cardiology , vol.45 , Issue.5 , pp. 754-762
    • Vogel, R.1    Indermhle, A.2    Reinhardt, J.3    Meier, P.4    Siegrist, P.T.5    Namdar, M.6    Kaufmann, P.A.7
  • 50
    • 33745685392 scopus 로고    scopus 로고
    • Contrast ultrasound imaging of the carotid artery vasa vasarum and atherosclerotic plaque neovascularization
    • S. B. Feinstein, Contrast ultrasound imaging of the carotid artery vasa vasarum and atherosclerotic plaque neovascularization, J. Am. College Cardiology 48 (2006) 236-243.
    • (2006) J. Am. College Cardiology , vol.48 , pp. 236-243
    • Feinstein, S.B.1
  • 51
    • 0033528660 scopus 로고    scopus 로고
    • Angiogenesis inhibitors endostatin or tnp-470 reduce intimal neovascolarization and plaque growth in apolipoprotein e-deficient mice
    • K. S. Moulton, E. Heller, M. A. Konerding, E. Flynn, W Palinski and J Folkman, Angiogenesis inhibitors endostatin or tnp-470 reduce intimal neovascolarization and plaque growth in apolipoprotein e-deficient mice, Circulation 99 (1999) 1726-1732.
    • (1999) Circulation , vol.99 , pp. 1726-1732
    • Moulton, K.S.1    Heller, E.2    Konerding, M.A.3    Flynn, E.4    Palinski, W.5    Folkman, J.6
  • 52
    • 0037448791 scopus 로고    scopus 로고
    • Quantitative magnetic resonance imaging analysis of neovasculature volume in carotid atherosclerotic plaque
    • W. Kerwin, A. Hooker, M. Spilker, P. Vicini, M. Ferguson, T. Hatsukami and C. Yuan, Quantitative magnetic resonance imaging analysis of neovasculature volume in carotid atherosclerotic plaque, Circulation 107 (2003) 851-856.
    • (2003) Circulation , vol.107 , pp. 851-856
    • Kerwin, W.1    Hooker, A.2    Spilker, M.3    Vicini, P.4    Ferguson, M.5    Hatsukami, T.6    Yuan, C.7
  • 53
    • 0035676678 scopus 로고    scopus 로고
    • Assessing spectral algorithms to predict atherosclerosis plaque composition with normalized and raw intravascular ultrasound data
    • A. Nair, B. D. Kuban, N. Obuchowski and G. Vince, Assessing spectral algorithms to predict atherosclerosis plaque composition with normalized and raw intravascular ultrasound data, Ultrasound in Medicine and Biology 27, 10 (2001) 1319-1331.
    • (2001) Ultrasound in Medicine and Biology , vol.27 , Issue.10 , pp. 1319-1331
    • Nair, A.1    Kuban, B.D.2    Obuchowski, N.3    Vince, G.4
  • 57
    • 0000003630 scopus 로고
    • Measurement of cardiac output in anaesthetised animals by a thermodilution method
    • G. Fegler, Measurement of cardiac output in anaesthetised animals by a thermodilution method, Q. J. Exp. Physiol. 39 (1954) 153-164.
    • (1954) Q. J. Exp. Physiol , vol.39 , pp. 153-164
    • Fegler, G.1
  • 58
    • 0014964972 scopus 로고
    • Catheterization of the heart in man with use of a flow-directed, balloon-tipped catheter
    • H. J. C. Swan, W. Ganz, J. Forrester, H. Marcus, G. Diamond and D. Chonette, Catheterization of the heart in man with use of a flow-directed, balloon-tipped catheter, N. Engl. J. Med. 283 (1971) 447-451.
    • (1971) N. Engl. J. Med , vol.283 , pp. 447-451
    • Swan, H.J.C.1    Ganz, W.2    Forrester, J.3    Marcus, H.4    Diamond, G.5    Chonette, D.6
  • 59
    • 0025130516 scopus 로고
    • Continuous measurement of cardiac output with the use of stochastic system identification techniques
    • M. Yelderman, Continuous measurement of cardiac output with the use of stochastic system identification techniques, J. Clin. Monit. 6 (1990) 322-332.
    • (1990) J. Clin. Monit , vol.6 , pp. 322-332
    • Yelderman, M.1
  • 60
    • 0036494427 scopus 로고    scopus 로고
    • Real time, continuous monitoring of cardiac output and oxygen delivery
    • M. Jonas, D. Hett and J. Morgan, Real time, continuous monitoring of cardiac output and oxygen delivery, Int. J. of Intesive Care 9, 1 (2002).
    • (2002) Int. J. of Intesive Care , vol.9 , pp. 1
    • Jonas, M.1    Hett, D.2    Morgan, J.3
  • 61
    • 0032750908 scopus 로고    scopus 로고
    • Lithium dilution cardiac output measurements using a peripheral injection site: Comparison with central injection technique and thermodilution
    • T. Kurita, K. Morita, S. Kato, H. Kawasaki, M. Kikura, T. Kazama and K. Ikeda, Lithium dilution cardiac output measurements using a peripheral injection site: Comparison with central injection technique and thermodilution, J. of Clinical Monitoring and Computing 15 (1999) 279-285.
    • (1999) J. of Clinical Monitoring and Computing , vol.15 , pp. 279-285
    • Kurita, T.1    Morita, K.2    Kato, S.3    Kawasaki, H.4    Kikura, M.5    Kazama, T.6    Ikeda, K.7
  • 62
    • 0036799972 scopus 로고    scopus 로고
    • Pulseco: A less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery
    • T. T. Hamilton, L. M. Huber and M. E. Jessen, Pulseco: A less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery, A. Thoracic Surgery 74 (2002) S1408-1412.
    • (2002) A. Thoracic Surgery , vol.74 , pp. S1408-S1412
    • Hamilton, T.T.1    Huber, L.M.2    Jessen, M.E.3
  • 63
    • 0036014538 scopus 로고    scopus 로고
    • Lithium dilution measurements of cardiac output and arterial pulse waveform analysis: An indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output
    • M. M. Jonas and S. J. Tanzer, Lithium dilution measurements of cardiac output and arterial pulse waveform analysis: An indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output, Current Opinion in Critical Care 8 (2002) 257-261.
    • (2002) Current Opinion in Critical Care , vol.8 , pp. 257-261
    • Jonas, M.M.1    Tanzer, S.J.2
  • 69
    • 0032700101 scopus 로고    scopus 로고
    • Initial clinical experience of real-time threedimensional echocardiography in patients with ischemic and idiopathic dialated car-diomiopathy
    • T. Shiota, P. M. McCarthy, R. D. White, Jian Xin Quin, N. L. Greenberg, S. D. Flamm, J. Wong and J. D. Thomas, Initial clinical experience of real-time threedimensional echocardiography in patients with ischemic and idiopathic dialated car-diomiopathy, Am. J. of Cardiology 84 (1999) 1068-1073.
    • (1999) Am. J. of Cardiology , vol.84 , pp. 1068-1073
    • Shiota, T.1    McCarthy, P.M.2    White, R.D.3    Quin, J.X.4    Greenberg, N.L.5    Flamm, S.D.6    Wong, J.7    Thomas, J.D.8
  • 70
    • 0004149569 scopus 로고
    • Lippincott Williams & Wilkins, fifth edition
    • H. Feigenbaum, Echocardiography (Lippincott Williams & Wilkins, fifth edition, 1994).
    • (1994) Echocardiography
    • Feigenbaum, H.1
  • 71
    • 0028471176 scopus 로고
    • Myocardial contrast enhancement after intravenous injection of sonicated albumin microbubbles: A transesophageal echocardiography dipyridamole study
    • P. Voci, F. Bilotta, P. Merialdo and L. Agati, Myocardial contrast enhancement after intravenous injection of sonicated albumin microbubbles: A transesophageal echocardiography dipyridamole study, American Society of Echocardiography 7 (1994) 337346.
    • (1994) American Society of Echocardiography , vol.7 , pp. 337346
    • Voci, P.1    Bilotta, F.2    Merialdo, P.3    Agati, L.4
  • 72
    • 17444428610 scopus 로고    scopus 로고
    • Transesophageal echocardiography-related gastrointestinal complications in cardiac surgical patients
    • M. J. Lennon, N. M. Gibbs, W. M. Weightman, J. Leber, H. C. Ee and I. F. Yusoff, Transesophageal echocardiography-related gastrointestinal complications in cardiac surgical patients, J. Cardiothorac Vasc. Anesth. 19, 2 (2005) 141-145.
    • (2005) J. Cardiothorac Vasc. Anesth , vol.19 , Issue.2 , pp. 141-145
    • Lennon, M.J.1    Gibbs, N.M.2    Weightman, W.M.3    Leber, J.4    Ee, H.C.5    Yusoff, I.F.6
  • 73
    • 0032076476 scopus 로고    scopus 로고
    • Acoustic modeling of shell encapsuled gas bubbles
    • P. J. A. Frinking and N. de Jong, Acoustic modeling of shell encapsuled gas bubbles, Ultrasound in Med. and Biol. 24, 4 (1998) 523-533.
    • (1998) Ultrasound in Med. and Biol , vol.24 , Issue.4 , pp. 523-533
    • Frinking, P.J.A.1    De Jong, N.2
  • 74
    • 0034872356 scopus 로고    scopus 로고
    • Myocardial contrast agents: Recent advances and future directions
    • S. Mayer and P. A. Grayburn, Myocardial contrast agents: Recent advances and future directions, Progress in Cardiovascular Diseases 44, 1 (2001) 33-44.
    • (2001) Progress in Cardiovascular Diseases , vol.44 , Issue.1 , pp. 33-44
    • Mayer, S.1    Grayburn, P.A.2
  • 75
    • 3242697895 scopus 로고    scopus 로고
    • The powerful microbubble: From bench to bedside, from intravascular tracer to therapeutic delivery system and beyond
    • S. B. Feinstein, The powerful microbubble: from bench to bedside, from intravascular tracer to therapeutic delivery system and beyond, Am. J. of Physiology, Heart Circ. Physiol. 287 (2004) H450-H457.
    • (2004) Am. J. of Physiology, Heart Circ. Physiol , vol.287 , pp. H450-H457
    • Feinstein, S.B.1
  • 77
    • 0034865723 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography: Basic principles
    • S. Kaul, Myocardial contrast echocardiography: basic principles, Progress in Cardiovascular Deseases 44, 1 (2001) 1-11.
    • (2001) Progress in Cardiovascular Deseases , vol.44 , Issue.1 , pp. 1-11
    • Kaul, S.1
  • 83
    • 36149054747 scopus 로고
    • Cavitation produced by ultrasonics: Theoretical conditions for the onset of cavitation
    • E. A. Neppiras and B. E. Noltingk, Cavitation produced by ultrasonics: Theoretical conditions for the onset of cavitation, Proc. Phys Soc. B63 (1951) 1032-1038.
    • (1951) Proc. Phys Soc , vol.63 B , pp. 1032-1038
    • Neppiras, E.A.1    Noltingk, B.E.2
  • 84
    • 0002307661 scopus 로고
    • The collapse or growth of a spherical bubble or cavity in a viscous fluid
    • H. Poritsky, The collapse or growth of a spherical bubble or cavity in a viscous fluid, Proc. 1st US Nat. Cong, on Apllied Mechanics (1952) 813-821.
    • (1952) Proc. 1st US Nat. Cong, on Apllied Mechanics , pp. 813-821
    • Poritsky, H.1
  • 85
    • 0024025378 scopus 로고
    • Prediction of rectified diffusion during nonlinear bubble pulsations at biomedical frequencies
    • C. C. Church, Prediction of rectified diffusion during nonlinear bubble pulsations at biomedical frequencies, J. of Acoustic Society of America 83, 6 (1988) 2210-2217.
    • (1988) J. of Acoustic Society of America , vol.83 , Issue.6 , pp. 2210-2217
    • Church, C.C.1
  • 86
    • 0024114296 scopus 로고
    • A method to account for acoustic microstreaming when predicying bubble growth rates produced by rectified diffusion
    • C. C. Church, A method to account for acoustic microstreaming when predicying bubble growth rates produced by rectified diffusion, J. of Acoustic Society of America 84, 5 (1988) 1758-1764.
    • (1988) J. of Acoustic Society of America , vol.84 , Issue.5 , pp. 1758-1764
    • Church, C.C.1
  • 87
    • 0026830293 scopus 로고
    • Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measrements
    • N. de Jong, L. Hoff, T. Skotland and N. Bom, Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measrements, Ultrasonics 30, 2 (1992) 95-103.
    • (1992) Ultrasonics , vol.30 , Issue.2 , pp. 95-103
    • De Jong, N.1    Hoff, L.2    Skotland, T.3    Bom, N.4
  • 88
    • 0030164302 scopus 로고    scopus 로고
    • Acoustic properties of ultrasound contrast agents
    • L. Hoff, Acoustic properties of ultrasound contrast agents, Ultrasonics 34 (1996) 591-593.
    • (1996) Ultrasonics , vol.34 , pp. 591-593
    • Hoff, L.1
  • 90
    • 0003784142 scopus 로고
    • Theory of pulsations of the gas bubble produced by an underwater explosion
    • C. Herring, Theory of pulsations of the gas bubble produced by an underwater explosion, Report 236, O.S.R.D. (1941).
    • (1941) Report 236, O.S.R.D
    • Herring, C.1
  • 92
    • 0036566270 scopus 로고    scopus 로고
    • The dipendence of ultrasound contrast agents backscatter on acoustic pressure: Theory versus experiment
    • V. Sboros, C. A. MacDonald, S. D. Pye, C. M. Mran, J. Gomatam and W. N. McDicken, The dipendence of ultrasound contrast agents backscatter on acoustic pressure: theory versus experiment, Ultrasonics 40 (2002) 579-583.
    • (2002) Ultrasonics , vol.40 , pp. 579-583
    • Sboros, V.1    MacDonald, C.A.2    Pye, S.D.3    Mran, C.M.4    Gomatam, J.5    McDicken, W.N.6
  • 93
    • 0016521859 scopus 로고
    • Cavitation dynamics I: A mathematical formulation
    • H. G. Flynn, Cavitation dynamics I: A mathematical formulation, J. of Acoustic Society of America 57 (1975) 1379-1396.
    • (1975) J. of Acoustic Society of America , vol.57 , pp. 1379-1396
    • Flynn, H.G.1
  • 94
    • 0034297853 scopus 로고    scopus 로고
    • Predicting the acoustic response of a microbubble population for contrast imaging in medical ultrasound
    • C. T. Chin and P. Burns, Predicting the acoustic response of a microbubble population for contrast imaging in medical ultrasound, Ultrasound in Med. and Biol. 26, 8 (2000) 1293-1300.
    • (2000) Ultrasound in Med. and Biol , vol.26 , Issue.8 , pp. 1293-1300
    • Chin, C.T.1    Burns, P.2
  • 100
    • 84967485241 scopus 로고    scopus 로고
    • Free oscillations of microbubbles as observed using a new 25 million frames per second camera
    • Honolulu, Hawaii, October, IEEE UFFC Society
    • C. T. Chin, M. Versluis, C. Lancee and N. de Jong, Free oscillations of microbubbles as observed using a new 25 million frames per second camera, IEEE International Ultrasonics Symposium, Honolulu, Hawaii, October 2003, IEEE UFFC Society.
    • (2003) IEEE International Ultrasonics Symposium
    • Chin, C.T.1    Versluis, M.2    Lancee, C.3    De Jong, N.4
  • 105
    • 0034209660 scopus 로고    scopus 로고
    • Feasibility of mitral flow assessment by echo contrast ultrasound, part I: Determination of the properties of echo-contrast agents
    • B. Herman, S. Einav and Z. Vered, Feasibility of mitral flow assessment by echo contrast ultrasound, part I: Determination of the properties of echo-contrast agents, Ultrasound in Med. and Biol. 26, 5 (2000) 785-795.
    • (2000) Ultrasound in Med. and Biol , vol.26 , Issue.5 , pp. 785-795
    • Herman, B.1    Einav, S.2    Vered, Z.3
  • 106
    • 0031193982 scopus 로고    scopus 로고
    • Mathematical modeling of dilution curves for ultrasonographic contrast
    • C. S. Sehgal and P. H. Arger, Mathematical modeling of dilution curves for ultrasonographic contrast, J. Ultrasound in Medicine 16 (1997) 471-479.
    • (1997) J. Ultrasound in Medicine , vol.16 , pp. 471-479
    • Sehgal, C.S.1    Arger, P.H.2
  • 107
    • 0032830282 scopus 로고    scopus 로고
    • Influence of bubble size distribution on echogenecity of ultrasound contrast agents: A study of sonovue
    • M. Shneider, Influence of bubble size distribution on echogenecity of ultrasound contrast agents: A study of sonovue, Echocardiography 16, 7 (1999) 743-746.
    • (1999) Echocardiography , vol.16 , Issue.7 , pp. 743-746
    • Shneider, M.1
  • 108
    • 0033727931 scopus 로고    scopus 로고
    • Bubble oscillations of large amplitude
    • J. M. Gorce, M. Arditi and M. Schneider, Bubble oscillations of large amplitude, Invest. Radiol. 35, 11 (2000) 661-671.
    • (2000) Invest. Radiol , vol.35 , Issue.11 , pp. 661-671
    • Gorce, J.M.1    Arditi, M.2    Schneider, M.3
  • 109
    • 0031210510 scopus 로고    scopus 로고
    • New expressions of acoustic cross-sections of a single bubble in the monopole bubbly theory
    • R. A. Thuraisingham, New expressions of acoustic cross-sections of a single bubble in the monopole bubbly theory, Ultrasonics 35 (1997) 407-409.
    • (1997) Ultrasonics , vol.35 , pp. 407-409
    • Thuraisingham, R.A.1
  • 110
    • 0030359280 scopus 로고    scopus 로고
    • In vitro standard acoustic parameters of ultrasound contrast agents: Definitions and calculations
    • A. Bouakaz, N. de Jong, L. Gerfault and C. Cachard, In vitro standard acoustic parameters of ultrasound contrast agents: definitions and calculations, IEEE International Ultrasonics Symposium 2 (1996) 1445-1448.
    • (1996) IEEE International Ultrasonics Symposium , vol.2 , pp. 1445-1448
    • Bouakaz, A.1    De Jong, N.2    Gerfault, L.3    Cachard, C.4
  • 111
    • 0032033726 scopus 로고    scopus 로고
    • Standard properties of ultrasound contrast agents
    • A. Bouakaz, N. de Jong and C. Cachard, Standard properties of ultrasound contrast agents, Ultrasound in Med. and Biol. 24, 3 (1996) 469-472.
    • (1996) Ultrasound in Med. and Biol , vol.24 , Issue.3 , pp. 469-472
    • Bouakaz, A.1    De Jong, N.2    Cachard, C.3
  • 114
    • 0017347470 scopus 로고
    • Counting bubbles acoustically: A review
    • H. Medwin, Counting bubbles acoustically: A review, Ultrasonics 15, 1 (1977) 7-13.
    • (1977) Ultrasonics , vol.15 , Issue.1 , pp. 7-13
    • Medwin, H.1
  • 116
    • 0025142480 scopus 로고
    • On the application of ultrasonic contrast agents for blood flowmetry and assesment of cardiac perfusion
    • H. Bleeker, K. Shung and J. Barnhart, On the application of ultrasonic contrast agents for blood flowmetry and assesment of cardiac perfusion, Ultrasound in Med. and Biol. 9 (1990) 461-471.
    • (1990) Ultrasound in Med. and Biol , vol.9 , pp. 461-471
    • Bleeker, H.1    Shung, K.2    Barnhart, J.3
  • 118
    • 1842455119 scopus 로고    scopus 로고
    • The role of cavitation microjets in thetherapeutic applications of ultrasound
    • E. A. Brujan, The role of cavitation microjets in thetherapeutic applications of ultrasound, Ultrasound in Med. and Biol. 30, 3 (2004) 381-387.
    • (2004) Ultrasound in Med. and Biol , vol.30 , Issue.3 , pp. 381-387
    • Brujan, E.A.1
  • 119
    • 12244264869 scopus 로고    scopus 로고
    • The use of microbubbles to target drug delivery
    • J. M. Tsutsui, F. Xie and T. R. Porter, The use of microbubbles to target drug delivery, Cardiovascular Ultrasound 2, 23 (2004) 1-7.
    • (2004) Cardiovascular Ultrasound , vol.2 , Issue.23 , pp. 1-7
    • Tsutsui, J.M.1    Xie, F.2    Porter, T.R.3
  • 121
    • 1642632707 scopus 로고    scopus 로고
    • Polymeric contrast agent with targeting potential
    • J. D. Lathia, L. Leodore and M. A. Wheatley, Polymeric contrast agent with targeting potential, Ultrasonics 42 (2004) 763-768.
    • (2004) Ultrasonics , vol.42 , pp. 763-768
    • Lathia, J.D.1    Leodore, L.2    Wheatley, M.A.3
  • 122
    • 0345862002 scopus 로고    scopus 로고
    • Targeted tissue transfection with ultrasound destruction of plasmid-bearings cationic microbubbles
    • J. P. Christiansen, B. A. French, A. L. Klibanov, S. Kaul and J. R. Lindner, Targeted tissue transfection with ultrasound destruction of plasmid-bearings cationic microbubbles, Ultrasound in Med. and Biol. 29(12) (2003) 1759-1767.
    • (2003) Ultrasound in Med. and Biol , vol.29 , Issue.12 , pp. 1759-1767
    • Christiansen, J.P.1    French, B.A.2    Klibanov, A.L.3    Kaul, S.4    Lindner, J.R.5
  • 123
    • 0034821925 scopus 로고    scopus 로고
    • Ultrasound, microbubbles and thrombolysis
    • T. R. Porter and F. Xie, Ultrasound, microbubbles and thrombolysis, Progress in Cardiovascular Disease 44, 2 (2001) 101-110.
    • (2001) Progress in Cardiovascular Disease , vol.44 , Issue.2 , pp. 101-110
    • Porter, T.R.1    Xie, F.2
  • 124
    • 0035138506 scopus 로고    scopus 로고
    • Intermittent harmonic imaging and videodensitometry significantly enhance ability of intravenous air-filled ultrasonographic contrast agent to produce ventricular and myocardial opacification
    • G. T. Sieswerda, O. Kamp, R. van den Ende and C. A. Visser, Intermittent harmonic imaging and videodensitometry significantly enhance ability of intravenous air-filled ultrasonographic contrast agent to produce ventricular and myocardial opacification, J. Am. Soc. Echocardiography 14, 1 (2001) 20-28.
    • (2001) J. Am. Soc. Echocardiography , vol.14 , Issue.1 , pp. 20-28
    • Sieswerda, G.T.1    Kamp, O.2    Van den Ende, R.3    Visser, C.A.4
  • 125
    • 0032977268 scopus 로고    scopus 로고
    • Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging
    • J. Hancock, H. Dittrich, D. E. Jewitt and M. J. Monaghan, Evaluation of myocardial, hepatic, and renal perfusion in a variety of clinical conditions using an intravenous ultrasound contrast agent (Optison) and second harmonic imaging, Heart 81 (1999) 636-641.
    • (1999) Heart , vol.81 , pp. 636-641
    • Hancock, J.1    Dittrich, H.2    Jewitt, D.E.3    Monaghan, M.J.4
  • 127
    • 0036565951 scopus 로고    scopus 로고
    • Improved contrast to tissue ratio at higher harmonics
    • A. Bouakaz, S. Frigstad, F. J. ten Cate and N. de Jong, Improved contrast to tissue ratio at higher harmonics, Ultrasonics 40 (2002) 575-578.
    • (2002) Ultrasonics , vol.40 , pp. 575-578
    • Bouakaz, A.1    Frigstad, S.2    Ten Cate, F.J.3    De Jong, N.4
  • 130
    • 0036192574 scopus 로고    scopus 로고
    • Super harmonic imaging: A new imaging technique for improved contrast detection
    • A. Bouakaz S. Frigstad, N. de Jong and F. J. ten Cate, Super harmonic imaging: a new imaging technique for improved contrast detection, Ultrasound in Med., and Biol. 28, 1 (2002) 59-68.
    • (2002) Ultrasound in Med., and Biol , vol.28 , Issue.1 , pp. 59-68
    • Bouakaz, A.1    Frigstad, S.2    De Jong, N.3    Ten Cate, F.J.4
  • 131
    • 0034152738 scopus 로고    scopus 로고
    • Subharmonic imaging of contrast agents
    • F. Forsberg, W. T. Shi and B. B. Goldberg, Subharmonic imaging of contrast agents, Ultrasonics 38 (2000) 87-92.
    • (2000) Ultrasonics , vol.38 , pp. 87-92
    • Forsberg, F.1    Shi, W.T.2    Goldberg, B.B.3
  • 135
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-inuced destruction of microbubbles administrated as a constant venous infusion
    • K. Wei, A. R. Jayaweera, S. Firoozan, A. Linka, D. M. Skyba and S. Kaul, Quantification of myocardial blood flow with ultrasound-inuced destruction of microbubbles administrated as a constant venous infusion, Curculation 97 (1998) 473-483.
    • (1998) Curculation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3    Linka, A.4    Skyba, D.M.5    Kaul, S.6
  • 144
    • 0015091857 scopus 로고
    • Measurement of heart chamber volumes by analysis of dilution curves simultaneously recorded by scintillation camera
    • Y. Ishii and W. J. Macintyre, Measurement of heart chamber volumes by analysis of dilution curves simultaneously recorded by scintillation camera, Circulation 44 (1971) 37-46.
    • (1971) Circulation , vol.44 , pp. 37-46
    • Ishii, Y.1    Macintyre, W.J.2
  • 145
    • 0019812645 scopus 로고
    • Noninvasive measurement of cardiopulmonary blood volume, Evaluation of the centroid method
    • F. M. Fouad, W. J. Macintyre and R. C. Tarazi, Noninvasive measurement of cardiopulmonary blood volume, Evaluation of the centroid method, J. Nuclear Medicine 22, 3 (1981) 205-211.
    • (1981) J. Nuclear Medicine , vol.22 , Issue.3 , pp. 205-211
    • Fouad, F.M.1    Macintyre, W.J.2    Tarazi, R.C.3
  • 151
    • 0032610479 scopus 로고    scopus 로고
    • Contrast mechanisms in MR imaging
    • W. R. Nitz and P. Reimer, Contrast mechanisms in MR imaging, European Radiology 9 (1999) 1032-1046.
    • (1999) European Radiology , vol.9 , pp. 1032-1046
    • Nitz, W.R.1    Reimer, P.2
  • 152
    • 0025783488 scopus 로고
    • GRASE (gradient-and spin-echo) imaging: A novel fast MRI technique
    • K. Oshio and D. A. Feinberg, GRASE (gradient-and spin-echo) imaging: A novel fast MRI technique, Magnetic Resonance in Medicine 20(2) (1991) 344-349.
    • (1991) Magnetic Resonance in Medicine , vol.20 , Issue.2 , pp. 344-349
    • Oshio, K.1    Feinberg, D.A.2
  • 153
    • 0036887294 scopus 로고    scopus 로고
    • Fast and ultrafast non-echo-planar MR imaging techniques
    • W. R. Nitz, Fast and ultrafast non-echo-planar MR imaging techniques, European Radiology 12(12) (2002) 2866-2882.
    • (2002) European Radiology , vol.12 , Issue.12 , pp. 2866-2882
    • Nitz, W.R.1
  • 154
    • 0032743048 scopus 로고    scopus 로고
    • MR imaging abbreviations, definitions and descriptions: A review
    • M. A. Brown and R. C. Semelka, MR imaging abbreviations, definitions and descriptions: A review, Radiology 213 (1999) 647-662.
    • (1999) Radiology , vol.213 , pp. 647-662
    • Brown, M.A.1    Semelka, R.C.2
  • 155
    • 0030183194 scopus 로고    scopus 로고
    • HASTE MR imaging: Description of technique and preliminary results in the abdomen
    • R. C. Semelka, N. L. Kelekis, D. Thomasson, M. A. Brown and G. A. Laub, HASTE MR imaging: Description of technique and preliminary results in the abdomen, J. of Magn. Reson. Imag. 6, 4 (1996) 698-699.
    • (1996) J. of Magn. Reson. Imag , vol.6 , Issue.4 , pp. 698-699
    • Semelka, R.C.1    Kelekis, N.L.2    Thomasson, D.3    Brown, M.A.4    Laub, G.A.5
  • 158
    • 0242385483 scopus 로고    scopus 로고
    • k-t blast and k-t sense: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • J. Tsao, P. Boesiger and K. L. Pruessmann, k-t blast and k-t sense: Dynamic MRI with high frame rate exploiting spatiotemporal correlations, Magnetic Resonance in Medicine 50 (2003) 1031-1042.
    • (2003) Magnetic Resonance in Medicine , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.L.3
  • 160
    • 0034491722 scopus 로고    scopus 로고
    • Rapid relaxation times measurements by MRI: An in vivo application to contrast agent modeling for muscle fiber types characterization
    • V. Dedieu, P. Fau, P. Otal, J. P. Renou, V. Emerit, F. Joffre and D. Vicensini, Rapid relaxation times measurements by MRI: An in vivo application to contrast agent modeling for muscle fiber types characterization, Magnetic Resonance Imaging 18 (2000) 1221-1233.
    • (2000) Magnetic Resonance Imaging , vol.18 , pp. 1221-1233
    • Dedieu, V.1    Fau, P.2    Otal, P.3    Renou, J.P.4    Emerit, V.5    Joffre, F.6    Vicensini, D.7
  • 162
    • 0032882689 scopus 로고    scopus 로고
    • Accurancy of T1 measurements at high temporal resolution: Feasibility of dynamic measurement of blood T1 after contrast administration
    • J. Zheng, R. Venkatesan, E. M. Haacke, F. M. Cavagna, P. J. Finn and D. Li, Accurancy of T1 measurements at high temporal resolution: Feasibility of dynamic measurement of blood T1 after contrast administration, J. Magn. Reson. Imag. 10 (1999) 576-581.
    • (1999) J. Magn. Reson. Imag , vol.10 , pp. 576-581
    • Zheng, J.1    Venkatesan, R.2    Haacke, E.M.3    Cavagna, F.M.4    Finn, P.J.5    Li, D.6
  • 165
  • 167
    • 0033647178 scopus 로고    scopus 로고
    • Simultaneous MRI measurement of blood flow, blood volume, and capillary permeability in mammary tumors using two different contrast agent
    • E. Henderson, J. Sykes, D. Drost, H. J. Weinmann, B. K. Rutt and T. Y. Lee, Simultaneous MRI measurement of blood flow, blood volume, and capillary permeability in mammary tumors using two different contrast agent, J. of Magn. Reson. Imag. 12 (2000) 991-1003.
    • (2000) J. of Magn. Reson. Imag , vol.12 , pp. 991-1003
    • Henderson, E.1    Sykes, J.2    Drost, D.3    Weinmann, H.J.4    Rutt, B.K.5    Lee, T.Y.6
  • 168
    • 0032845185 scopus 로고    scopus 로고
    • Multicompartment analysis of gadolinium chelate kinetics: Blood-tissue exchange in mammary tumors by dynamic MR imaging
    • E. P. Ruediger, M. V. Knopp, U. Hoffmann, S. Milker-Zabel and G. Brix, Multicompartment analysis of gadolinium chelate kinetics: Blood-tissue exchange in mammary tumors by dynamic MR imaging, J. of Magn. Reson. Imag. 10 (1999) 233-241.
    • (1999) J. of Magn. Reson. Imag , vol.10 , pp. 233-241
    • Ruediger, E.P.1    Knopp, M.V.2    Hoffmann, U.3    Milker-Zabel, S.4    Brix, G.5
  • 169
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. part II: Experimental comparison and preliminary results
    • L. Ostergaard, A. Gregory Sorensen, K. K. Kwong, R. M. Weisskoff, C. Gyldensted and B. R. Rosen, High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. part II: Experimental comparison and preliminary results, Magnetic Resonance in Medicine 36, 5 (1996) 726-736.
    • (1996) Magnetic Resonance in Medicine , vol.36 , Issue.5 , pp. 726-736
    • Ostergaard, L.1    Gregory Sorensen, A.2    Kwong, K.K.3    Weisskoff, R.M.4    Gyldensted, C.5    Rosen, B.R.6
  • 171
  • 172
    • 0031404162 scopus 로고    scopus 로고
    • Modelling tracer kinetics in dynamic Gd-DPTA MR imaging
    • P. S. Tofts, Modelling tracer kinetics in dynamic Gd-DPTA MR imaging, J. of Magn. Reson. Imag. 7(1) (1997) 91-101.
    • (1997) J. of Magn. Reson. Imag , vol.7 , Issue.1 , pp. 91-101
    • Tofts, P.S.1
  • 174
    • 12844284000 scopus 로고    scopus 로고
    • Effect of intravascular-to-extravascular water exchange on the determination of blood-to tissue transfer constant by magnetic resonance imaging
    • Y. Cao, S. L. Brown, R. A. Knight, J. D. Fenstermacher and J. R. Ewing, Effect of intravascular-to-extravascular water exchange on the determination of blood-to tissue transfer constant by magnetic resonance imaging, Magnetic Resonance in Medicine 53 (2005) 282-293.
    • (2005) Magnetic Resonance in Medicine , vol.53 , pp. 282-293
    • Cao, Y.1    Brown, S.L.2    Knight, R.A.3    Fenstermacher, J.D.4    Ewing, J.R.5
  • 175
    • 0036151476 scopus 로고    scopus 로고
    • MRI detection of myocardial perfusion defects due to coronary artery stenosis with MS-325
    • D. L. Kraitchman, B. B. Chin, A. W. Heldman, M. Solaiyappan and D. A. Bluemke, MRI detection of myocardial perfusion defects due to coronary artery stenosis with MS-325, J. of Magn. Reson. Imag. 15, 2 (2002) 149-158.
    • (2002) J. of Magn. Reson. Imag , vol.15 , Issue.2 , pp. 149-158
    • Kraitchman, D.L.1    Chin, B.B.2    Heldman, A.W.3    Solaiyappan, M.4    Bluemke, D.A.5
  • 177
    • 0242331782 scopus 로고    scopus 로고
    • Magneticresonance imaging of myocardial contrast enhancement with MS-325 and its relation to myocardial blood flow and perfusion reserve
    • M. Jerosch-Herold, X. Hu, N. S. Murthy, C. Rickers and A. E. Stillman, Magneticresonance imaging of myocardial contrast enhancement with MS-325 and its relation to myocardial blood flow and perfusion reserve, J. of Magnetic Resonance Imaging 18, 5 (2003) 544-554.
    • (2003) J. of Magnetic Resonance Imaging , vol.18 , Issue.5 , pp. 544-554
    • Jerosch-Herold, M.1    Hu, X.2    Murthy, N.S.3    Rickers, C.4    Stillman, A.E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.