메뉴 건너뛰기




Volumn 2003, Issue 5, 2003, Pages 479-489

Videodensitometric methods for cardiac output measurements

Author keywords

Contrast agents; Local density random walk; Ultrasound; Videodensitometry

Indexed keywords

ALGORITHMS; CARDIOVASCULAR SYSTEM; COMPUTER SIMULATION; CONTRAST MEDIA; DENSITY MEASUREMENT (OPTICAL); HEMODYNAMICS; IMAGE ANALYSIS; NONINVASIVE MEDICAL PROCEDURES; REGRESSION ANALYSIS; ULTRASONIC TRANSDUCERS; ULTRASONICS;

EID: 0037851014     PISSN: 11108657     EISSN: None     Source Type: Journal    
DOI: 10.1155/S1110865703211185     Document Type: Article
Times cited : (45)

References (42)
  • 1
    • 0031193982 scopus 로고    scopus 로고
    • Mathematical modeling of the dilution curves for ultrasonographic contrast agents
    • C. M. Sehgal and P. H. Arger, "Mathematical modeling of the dilution curves for ultrasonographic contrast agents," Journal of Ultrasound in Medicine, 16, pp. 471-479, 1997.
    • (1997) Journal of Ultrasound in Medicine , vol.16 , pp. 471-479
    • Sehgal, C.M.1    Arger, P.H.2
  • 2
    • 0023214879 scopus 로고
    • Contrast echo washout curves from left ventricle: Application of basic principles of indicator-dilution theory and calculation of ejection fraction
    • D. Rovani, S. E. Nissen, E. Jonathan, et al., "Contrast echo washout curves from left ventricle: application of basic principles of indicator-dilution theory and calculation of ejection fraction," Journal of the American College of Cardiology, vol. 10, pp. 125-134, 1987.
    • (1987) Journal of the American College of Cardiology , vol.10 , pp. 125-134
    • Rovani, D.1    Nissen, S.E.2    Jonathan, E.3
  • 3
    • 0033295061 scopus 로고    scopus 로고
    • Assessing blood flow in isolated pig heart with USCA
    • Lake Tahoe, Nev, USA
    • L. Gerfault, E. Helms, V. Bailleau, et al., "Assessing blood flow in isolated pig heart with USCA," in IEEE Ultrasonics Symposium, vol. 2, pp. 1725-1728, Lake Tahoe, Nev, USA, 1999.
    • (1999) IEEE Ultrasonics Symposium , vol.2 , pp. 1725-1728
    • Gerfault, L.1    Helms, E.2    Bailleau, V.3
  • 4
    • 0030380058 scopus 로고    scopus 로고
    • Videodensitometric measurements in contrast-echocardiography
    • Indianapolis, Ind, USA, September
    • T. Gustavsson, and M. Beckman-Suurkula, "Videodensitometric measurements in contrast-echocardiography," in IEEE Computers in Cardiology, pp. 709-712, Indianapolis, Ind, USA, September 1996.
    • (1996) IEEE Computers in Cardiology , pp. 709-712
    • Gustavsson, T.1    Beckman-Suurkula, M.2
  • 6
    • 0025142480 scopus 로고
    • On the application of ultrasonic contrast agents for blood flowmetry and assessment of cardiac perfusion
    • H. Bleeker, K. Shung, and J. Barnhart, "On the application of ultrasonic contrast agents for blood flowmetry and assessment of cardiac perfusion," Journal of Ultrasound in Medicine, vol. 9, no. 8, pp. 461-471, 1990.
    • (1990) Journal of Ultrasound in Medicine , vol.9 , Issue.8 , pp. 461-471
    • Bleeker, H.1    Shung, K.2    Barnhart, J.3
  • 8
    • 0032101113 scopus 로고    scopus 로고
    • A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography
    • X. Chen, K. Q. Schwartz, D. Phillips, S. D. Steinmetz and R. Schlief, "A mathematical model for the assessment of hemodynamic parameters using quantitative contrast echocardiography," IEEE Trans. Biomedical Engineering, vol. 45, no. 6, pp. 754-765, 1998.
    • (1998) IEEE Trans. Biomedical Engineering , vol.45 , Issue.6 , pp. 754-765
    • Chen, X.1    Schwartz, K.Q.2    Phillips, D.3    Steinmetz, S.D.4    Schlief, R.5
  • 11
    • 0342398226 scopus 로고    scopus 로고
    • Effects of shadowing on the time-intensity curves in contrast echocardiography: A phantom study
    • L. J. Bos, J. J. Piek, and J. A. Spaan, "Effects of shadowing on the time-intensity curves in contrast echocardiography: a phantom study," Ultrasound in Medicine & Biology, vol. 22, no. 2, pp. 217-227, 1996.
    • (1996) Ultrasound in Medicine & Biology , vol.22 , Issue.2 , pp. 217-227
    • Bos, L.J.1    Piek, J.J.2    Spaan, J.A.3
  • 12
    • 0001342827 scopus 로고
    • The random walk problem in relation to the physiology of circulatory mixing
    • C. W. Sheppard and L. J. Savage "The random walk problem in relation to the physiology of circulatory mixing," Physical Review, vol. 83, pp. 489-490, 1951.
    • (1951) Physical Review , vol.83 , pp. 489-490
    • Sheppard, C.W.1    Savage, L.J.2
  • 15
    • 85047680511 scopus 로고
    • Random walk type models for indicator-dilution studies: Comparison of a local density random walk and a first passage times distribution
    • J. M. Bogaard, J. R. C. Jansen, E. A. von Reth, A. Versprille, and M. E. Wise, "Random walk type models for indicator-dilution studies: comparison of a local density random walk and a first passage times distribution," Cardiovascular Research, vol. 20, no 11, pp. 789-796, 1986.
    • (1986) Cardiovascular Research , vol.20 , Issue.11 , pp. 789-796
    • Bogaard, J.M.1    Jansen, J.R.C.2    Von Reth, E.A.3    Versprille, A.4    Wise, M.E.5
  • 16
    • 0020781321 scopus 로고
    • Comparison of a two-compartment model and distributed models for indicator dilution studies
    • E. A. Ruth and J. M. Bogaard, Comparison of a two-compartment model and distributed models for indicator dilution studies, Medical & Biological Engineering & Computing, vol. 21, pp. 453-459, 1983.
    • (1983) Medical & Biological Engineering & Computing , vol.21 , pp. 453-459
    • Ruth, E.A.1    Bogaard, J.M.2
  • 17
    • 0021163861 scopus 로고
    • Physiological interpretation of skewness of indicator-dilution curves; theoretical considerations and practical application
    • J. M. Bogaard, S. J. Smith, A. Versatile, M. E. Wise and F. Homemaker, "Physiological interpretation of skewness of indicator-dilution curves; theoretical considerations and practical application," Basic Research in Cardiology, vol. 79, pp. 479-493, 1984.
    • (1984) Basic Research in Cardiology , vol.79 , pp. 479-493
    • Bogaard, J.M.1    Smith, S.J.2    Versatile, A.3    Wise, M.E.4    Homemaker, F.5
  • 18
    • 0013992712 scopus 로고
    • Tracer dilution curves in cardiology and random walk and lognormal distributions
    • M. E. Wise, "Tracer dilution curves in cardiology and random walk and lognormal distributions," Acta Physiol. Pharmacol. Neerl., vol. 14, pp. 175-204, 1966.
    • (1966) Acta Physiol. Pharmacol. Neerl. , vol.14 , pp. 175-204
    • Wise, M.E.1
  • 22
    • 0032862581 scopus 로고    scopus 로고
    • ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination
    • J. S. Shanewise, A. T. Cheung, S. Aronson, et al., "ASE/SCA guidelines for performing a comprehensive intraoperative multiplane transesophageal echocardiography examination: recommendations of the American Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography," Anesth Analg., vol. 89, no. 4, pp. 870-884, 1999.
    • (1999) Anesth Analg. , vol.89 , Issue.4 , pp. 870-884
    • Shanewise, J.S.1    Cheung, A.T.2    Aronson, S.3
  • 27
    • 0021840313 scopus 로고
    • Influence of random noise on accuracy of the indicator dilution method
    • J. M. Bogaard, W. A. van Duyl, A. Vesprille, and M. E. Wise, "Influence of random noise on accuracy of the indicator dilution method," Clin. Phys. Physiol. Meas., vol. 6, no. 1, pp. 59-64, 1985.
    • (1985) Clin. Phys. Physiol. Meas. , vol.6 , Issue.1 , pp. 59-64
    • Bogaard, J.M.1    Van Duyl, W.A.2    Vesprille, A.3    Wise, M.E.4
  • 28
    • 0028806018 scopus 로고
    • A new method of analysing indicator dilution curves
    • R. A. F. Linton, N. W. F. Linton, and D. M. Band, "A new method of analysing indicator dilution curves," Cardiovascular Research, vol. 30, pp. 930-938, 1995.
    • (1995) Cardiovascular Research , vol.30 , pp. 930-938
    • Linton, R.A.F.1    Linton, N.W.F.2    Band, D.M.3
  • 30
    • 0031369233 scopus 로고    scopus 로고
    • Modeling of ultrasound contrast agents
    • Toronto, Ontatio, Canada
    • P. J. A. Frinking and N. de Jong, "Modeling of ultrasound contrast agents," in IEEE Ultrasonics Symposium, pp. 1601-1604, Toronto, Ontatio, Canada, 1997.
    • (1997) IEEE Ultrasonics Symposium , pp. 1601-1604
    • Frinking, P.J.A.1    De Jong, N.2
  • 31
    • 0030359280 scopus 로고    scopus 로고
    • In vitro standard acoustic parameters of ultrasound contrast agents: Definitions and calculations
    • San Antonio, Tex, USA
    • A. Bouakaz, N. De Jong, L. Gerfault, and C. Cachard, "In vitro standard acoustic parameters of ultrasound contrast agents: definitions and calculations," in IEEE Ultrasonics Symposium, vol. 2, pp. 1445-1448, San Antonio, Tex, USA, 1996.
    • (1996) IEEE Ultrasonics Symposium , vol.2 , pp. 1445-1448
    • Bouakaz, A.1    De Jong, N.2    Gerfault, L.3    Cachard, C.4
  • 32
    • 0033727931 scopus 로고    scopus 로고
    • Influence of bubble size distribution on the echogenicity of ultrasound contrast agents: A study of SonoVue
    • J. M. Gorce, M. Arditi, and M. Schneider, "Influence of bubble size distribution on the echogenicity of ultrasound contrast agents: a study of SonoVue," Investigative Radiology, vol. 35, no. 11, pp. 661-671, 2000.
    • (2000) Investigative Radiology , vol.35 , Issue.11 , pp. 661-671
    • Gorce, J.M.1    Arditi, M.2    Schneider, M.3
  • 35
    • 0032033726 scopus 로고    scopus 로고
    • Standard properties of ultrasound contrast agents
    • A. Bouakaz, N. De Jong, and C. Cachard, "Standard properties of ultrasound contrast agents," Ultrasound in Medicine & Biology, vol. 24, no. 3, pp. 769-772, 1998.
    • (1998) Ultrasound in Medicine & Biology , vol.24 , Issue.3 , pp. 769-772
    • Bouakaz, A.1    De Jong, N.2    Cachard, C.3
  • 36
    • 0034209660 scopus 로고    scopus 로고
    • Feasibility of mitral flow assessment by echo-contrast ultrasound, part I: Determination of the properties of echo-contrast agents
    • B. Herman, S. Einav, and Z. Vered, "Feasibility of mitral flow assessment by echo-contrast ultrasound, part I: determination of the properties of echo-contrast agents," Ultrasound in Medicine & Biology, vol. 26, no. 5, pp. 785-795, 2000.
    • (2000) Ultrasound in Medicine & Biology , vol.26 , Issue.5 , pp. 785-795
    • Herman, B.1    Einav, S.2    Vered, Z.3
  • 37
    • 0032830282 scopus 로고    scopus 로고
    • Characteristics of SonoVue
    • M. Shneider, "Characteristics of SonoVue," Echocardiography, vol. 16, no. 7 (pt. 2), pp. 743-746, 1999.
    • (1999) Echocardiography , vol.16 , Issue.7 PART 2 , pp. 743-746
    • Shneider, M.1
  • 39
    • 0003978799 scopus 로고    scopus 로고
    • Information for manifactures seeking marketing and clearance of diagnostic ultrasound systems and transducers
    • U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, November
    • "Information for manifactures seeking marketing and clearance of diagnostic ultrasound systems and transducers," U.S. Department of Health and Human Services, Food and Drug Administration, Center for Devices and Radiological Health, November 1997.
    • (1997)
  • 42
    • 4244032105 scopus 로고    scopus 로고
    • Pattern recognition and image processing group
    • Vienna University of Technology
    • "Pattern recognition and image processing group, Vienna University of Technology," http://www.prip.tuwien.ac.at/Research/3DVision/Cameras/tutorial.html.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.