메뉴 건너뛰기




Volumn 43, Issue 5, 2000, Pages 691-700

Assessment of regional cerebral blood flow by dynamic susceptibility contrast MRI using different deconvolution techniques

Author keywords

Arterial input function; Cerebral blood flow (CBF); Dynamic susceptibility contrast magnetic resonance imaging (MRI); Nonparametric deconvolution

Indexed keywords

DECONVOLUTION; HEMODYNAMICS; MAGNETIC RESONANCE IMAGING; MAGNETIC SUSCEPTIBILITY; SINGULAR VALUE DECOMPOSITION;

EID: 0034063886     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2594(200005)43:5<691::AID-MRM11>3.0.CO;2-B     Document Type: Article
Times cited : (146)

References (31)
  • 1
    • 0031869598 scopus 로고    scopus 로고
    • Measurement of tumour vascular volume and mean microvascular random flow velocity magnitude by dynamic Gd-DTPA-albumin enhanced and diffusion-weighted MRI
    • Wang Z, Su M, Nalcioglu O. Measurement of tumour vascular volume and mean microvascular random flow velocity magnitude by dynamic Gd-DTPA-albumin enhanced and diffusion-weighted MRI. Magn Reson Med 1998;40:397-404.
    • (1998) Magn Reson Med , vol.40 , pp. 397-404
    • Wang, Z.1    Su, M.2    Nalcioglu, O.3
  • 2
    • 0032950722 scopus 로고    scopus 로고
    • Early changes measured by magnetic resonance imaging in cerebral blood flow, blood volume, and blood-brain barrier permeability following dexamethasone treatment in patients with brain tumors
    • Østergaard L, Hochberg FH, Rabinov JD, Sorensen AG, Lev M, Kim L, Weisskoff RM, Gonzalez RG, Gyldensted C, Rosen BR. Early changes measured by magnetic resonance imaging in cerebral blood flow, blood volume, and blood-brain barrier permeability following dexamethasone treatment in patients with brain tumors. J Neurosurg 1999;90:300-305.
    • (1999) J Neurosurg , vol.90 , pp. 300-305
    • ØStergaard, L.1    Hochberg, F.H.2    Rabinov, J.D.3    Sorensen, A.G.4    Lev, M.5    Kim, L.6    Weisskoff, R.M.7    Gonzalez, R.G.8    Gyldensted, C.9    Rosen, B.R.10
  • 3
    • 0031910536 scopus 로고    scopus 로고
    • MR-monitored LITT as a palliative concept in patients with high grade gliomas: Preliminary clinical experience
    • Reimer P, Bremer C, Horch C, Morgenroth C, Allkemper T, Schuierer G. MR-monitored LITT as a palliative concept in patients with high grade gliomas: preliminary clinical experience. J Magn Reson Imaging 1998; 8:240-244.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 240-244
    • Reimer, P.1    Bremer, C.2    Horch, C.3    Morgenroth, C.4    Allkemper, T.5    Schuierer, G.6
  • 8
    • 0031017934 scopus 로고    scopus 로고
    • Neuroprotection with NBQX in rat focal cerebral ischemia. Effects on ADC probability distribution functions and diffusion-perfusion relationships
    • Lo EH, Pierce AR, Mandeville JB, Rosen BR. Neuroprotection with NBQX in rat focal cerebral ischemia. Effects on ADC probability distribution functions and diffusion-perfusion relationships. Stroke 1997;28: 439-446.
    • (1997) Stroke , vol.28 , pp. 439-446
    • Lo, E.H.1    Pierce, A.R.2    Mandeville, J.B.3    Rosen, B.R.4
  • 9
    • 0031925103 scopus 로고    scopus 로고
    • Efficacy of intra-arterial and intravenous prourokinase in an embolic stroke model evaluated by diffusion-perfusion magnetic resonance imaging
    • Takano K, Carano RA, Tatlisumak T, Meiler M, Sotak CH, Kleinert HD, Fisher M. Efficacy of intra-arterial and intravenous prourokinase in an embolic stroke model evaluated by diffusion-perfusion magnetic resonance imaging. Neurology 1998;50:870-875.
    • (1998) Neurology , vol.50 , pp. 870-875
    • Takano, K.1    Carano, R.A.2    Tatlisumak, T.3    Meiler, M.4    Sotak, C.H.5    Kleinert, H.D.6    Fisher, M.7
  • 10
    • 0033045391 scopus 로고    scopus 로고
    • Intraarterial rtPA treatment of stroke assessed by diffusion- and perfusion-weighted MRI
    • Lansberg MG, Tong DC, Norbash AM, Yenari MA, Moseley ME. Intraarterial rtPA treatment of stroke assessed by diffusion- and perfusion-weighted MRI. Stroke 1999;30:678-680.
    • (1999) Stroke , vol.30 , pp. 678-680
    • Lansberg, M.G.1    Tong, D.C.2    Norbash, A.M.3    Yenari, M.A.4    Moseley, M.E.5
  • 11
    • 0021687090 scopus 로고
    • Cerebral transit of an intravascular tracer may allow measurement of regional blood volume but not regional blood flow
    • Lassen NA. Cerebral transit of an intravascular tracer may allow measurement of regional blood volume but not regional blood flow. J Cereb Blood Flow Metabol 1984;4:633-634.
    • (1984) J Cereb Blood Flow Metabol , vol.4 , pp. 633-634
    • Lassen, N.A.1
  • 12
    • 0027481892 scopus 로고
    • Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?
    • Weisskoff RM, Chesler D, Boxerman JL, Rosen BR. Pitfalls in MR measurement of tissue blood flow with intravascular tracers: which mean transit time? Magn Reson Med 1993;29:553-559.
    • (1993) Magn Reson Med , vol.29 , pp. 553-559
    • Weisskoff, R.M.1    Chesler, D.2    Boxerman, J.L.3    Rosen, B.R.4
  • 13
    • 0343684088 scopus 로고
    • Kinetics of distribution of tracer-labeled materials
    • Amsterdam: Elsevier
    • Jacquez JA. Kinetics of distribution of tracer-labeled materials. In: Compartmental analysis in biology and medicine. Amsterdam: Elsevier; 1972. p 84-101.
    • (1972) Compartmental Analysis in Biology and Medicine , pp. 84-101
    • Jacquez, J.A.1
  • 14
    • 0028061727 scopus 로고
    • A deconvolution method for evaluating indicator-dilution curves
    • Gobbel GT, Fike JR. A deconvolution method for evaluating indicator-dilution curves. Phys Med Biol 1994;39:1833-1854.
    • (1994) Phys Med Biol , vol.39 , pp. 1833-1854
    • Gobbel, G.T.1    Fike, J.R.2
  • 15
    • 0029619750 scopus 로고
    • Magnetic resonance perfusion imaging with gadolinium-DTPA: A quantitative approach for the kinetic analysis of first-pass residue curves
    • Bock JC, Henriksen O, Götze AHG, Wlodarczyk W, Sander B, Felix R. Magnetic resonance perfusion imaging with gadolinium-DTPA: a quantitative approach for the kinetic analysis of first-pass residue curves. Invest Radiol 1995;30:693-699.
    • (1995) Invest Radiol , vol.30 , pp. 693-699
    • Bock, J.C.1    Henriksen, O.2    Götze, A.H.G.3    Wlodarczyk, W.4    Sander, B.5    Felix, R.6
  • 16
    • 0028072844 scopus 로고
    • Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging
    • Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology 1994;193: 637-641.
    • (1994) Radiology , vol.193 , pp. 637-641
    • Rempp, K.A.1    Brix, G.2    Wenz, F.3    Becker, C.R.4    Gückel, F.5    Lorenz, W.J.6
  • 17
    • 0029907308 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. I. Mathematical approach and statistical analysis
    • Østergaard L, Weisskoff RM, Chesler DA, Gyldensted C, Rosen BR. High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. I. Mathematical approach and statistical analysis. Magn Reson Med 1996;36:715-725.
    • (1996) Magn Reson Med , vol.36 , pp. 715-725
    • ØStergaard, L.1    Weisskoff, R.M.2    Chesler, D.A.3    Gyldensted, C.4    Rosen, B.R.5
  • 18
    • 0029909977 scopus 로고    scopus 로고
    • High resolution measurement of cerebral blood flow using intravaseular tracer bolus passages. II. Experimental comparison and preliminary results
    • Østergaard L, Sorensen AG, Kwong KK, Weisskoff RM, Gyldensted C, Rosen DR. High resolution measurement of cerebral blood flow using intravaseular tracer bolus passages. II. Experimental comparison and preliminary results. Magn Reson Med 1996;36:726-736.
    • (1996) Magn Reson Med , vol.36 , pp. 726-736
    • ØStergaard, L.1    Sorensen, A.G.2    Kwong, K.K.3    Weisskoff, R.M.4    Gyldensted, C.5    Rosen, D.R.6
  • 19
    • 0032966087 scopus 로고    scopus 로고
    • Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI
    • Vonken EPA, Beekman FJ, Bakker CJG, Viergever MA. Maximum likelihood estimation of cerebral blood flow in dynamic susceptibility contrast MRI. Magn Reson Med 1999;41:343-350.
    • (1999) Magn Reson Med , vol.41 , pp. 343-350
    • Vonken, E.P.A.1    Beekman, F.J.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 20
  • 21
    • 0002629229 scopus 로고    scopus 로고
    • The value of gating and flow compensation for measurements of the arterial input function in dynamic susceptibility contrast MRI
    • Köstler H, Becker H. The value of gating and flow compensation for measurements of the arterial input function in dynamic susceptibility contrast MRI. MAGMA 1996;4(Suppl.):68.
    • (1996) MAGMA , vol.4 , Issue.SUPPL. , pp. 68
    • Köstler, H.1    Becker, H.2
  • 22
    • 0026081190 scopus 로고
    • MR contrast due to microscopically heterogeneous magnetic susceptibility: Numerical simulations and applications to cerebral physiology
    • Fisel CR, Ackerman JL, Buxton RB, Garrido L, Belliveau JW, Rosen BR, Brady TJ. MR contrast due to microscopically heterogeneous magnetic susceptibility: numerical simulations and applications to cerebral physiology. Magn Reson Med 1991;17:336-347.
    • (1991) Magn Reson Med , vol.17 , pp. 336-347
    • Fisel, C.R.1    Ackerman, J.L.2    Buxton, R.B.3    Garrido, L.4    Belliveau, J.W.5    Rosen, B.R.6    Brady, T.J.7
  • 23
    • 0001579379 scopus 로고
    • Equations for measuring blood flow by external monitoring of radioisotopes
    • Zierler KL. Equations for measuring blood flow by external monitoring of radioisotopes. Circ Res 1965;16:309-321.
    • (1965) Circ Res , vol.16 , pp. 309-321
    • Zierler, K.L.1
  • 26
    • 0030997814 scopus 로고    scopus 로고
    • Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise
    • Benner T, Heiland S, Erb G, Forsting M, Sartor K. Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to-noise. Magn Reson Imaging 1997:15:307-317.
    • (1997) Magn Reson Imaging , vol.15 , pp. 307-317
    • Benner, T.1    Heiland, S.2    Erb, G.3    Forsting, M.4    Sartor, K.5
  • 29
    • 0032814969 scopus 로고    scopus 로고
    • Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI
    • Vonken EPA, van Osch MJP, Bakker CJG, Viergever MA. Measurement of cerebral perfusion with dual-echo multi-slice quantitative dynamic susceptibility contrast MRI. J Magn Reson Imaging 1999;10:109-117.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 109-117
    • Vonken, E.P.A.1    Van Osch, M.J.P.2    Bakker, C.J.G.3    Viergever, M.A.4
  • 30
    • 0000174732 scopus 로고    scopus 로고
    • Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: Comparison with positron emission tomography values
    • Østergaard L, Smith DF, Vestergaard-Poulsen P, Hansen SB, Gee AD, Gjedde A, Gyldensted C. Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: comparison with positron emission tomography values. J Cereb Blood Flow Metabol 1998;18:425-432.
    • (1998) J Cereb Blood Flow Metabol , vol.18 , pp. 425-432
    • ØStergaard, L.1    Smith, D.F.2    Vestergaard-Poulsen, P.3    Hansen, S.B.4    Gee, A.D.5    Gjedde, A.6    Gyldensted, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.