메뉴 건너뛰기




Volumn 77, Issue 3, 2017, Pages 1170-1183

4D respiratory motion-compensated image reconstruction of free-breathing radial MR data with very high undersampling

Author keywords

4D MRI; joint estimation; radial sampling; respiratory motion compensation; undersampling

Indexed keywords

HIGH DEFINITION TELEVISION; MAGNETIC RESONANCE; MOTION COMPENSATION; MOTION ESTIMATION; RESPIRATORY MECHANICS;

EID: 84961267146     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.26206     Document Type: Article
Times cited : (84)

References (61)
  • 1
    • 0021235596 scopus 로고
    • The effect of motion on two-dimensional Fourier transformation magnetic resonance images
    • Schultz CL, Alfidi RJ, Nelson AD, Kopiwoda SY, Clampitt ME. The effect of motion on two-dimensional Fourier transformation magnetic resonance images. Radiology 1984;152:117–121.
    • (1984) Radiology , vol.152 , pp. 117-121
    • Schultz, C.L.1    Alfidi, R.J.2    Nelson, A.D.3    Kopiwoda, S.Y.4    Clampitt, M.E.5
  • 2
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992;28:275–289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 3
    • 84929332101 scopus 로고    scopus 로고
    • Towards routine clinical use of radial stack-of-stars 3D gradient-echo sequences for reducing motion sensitivity
    • Block KT, Chandarana H, Milla S, et al. Towards routine clinical use of radial stack-of-stars 3D gradient-echo sequences for reducing motion sensitivity. J Korean Soc Magn Reson Med 2014;18:87–106.
    • (2014) J Korean Soc Magn Reson Med , vol.18 , pp. 87-106
    • Block, K.T.1    Chandarana, H.2    Milla, S.3
  • 4
    • 0023017677 scopus 로고
    • Respiration artifacts in MR imaging: reduction by breath holding
    • Paling M, Brookeman J. Respiration artifacts in MR imaging: reduction by breath holding. J Comput Assist Tomogr 1986;10:1080–1082.
    • (1986) J Comput Assist Tomogr , vol.10 , pp. 1080-1082
    • Paling, M.1    Brookeman, J.2
  • 5
    • 55749109991 scopus 로고    scopus 로고
    • Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions
    • Lin W, Guo J, Rosen M a, Song HK. Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions. Magn Reson Med 2008;60:1135–1146.
    • (2008) Magn Reson Med , vol.60 , pp. 1135-1146
    • Lin, W.1    Guo, J.2    Rosen, M.A.3    Song, H.K.4
  • 6
    • 46849091615 scopus 로고    scopus 로고
    • Generalized reconstruction by inversion of coupled systems (GRICS) applied to parallel MRI
    • Odille F, Vuissoz PA, Marie PY, Felblinger J. Generalized reconstruction by inversion of coupled systems (GRICS) applied to parallel MRI. Magn Reson Med 2008;60:146–157.
    • (2008) Magn Reson Med , vol.60 , pp. 146-157
    • Odille, F.1    Vuissoz, P.A.2    Marie, P.Y.3    Felblinger, J.4
  • 7
    • 73149123166 scopus 로고    scopus 로고
    • High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting
    • Kellman P, Chefd'hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med 2009;62:1557–1564.
    • (2009) Magn Reson Med , vol.62 , pp. 1557-1564
    • Kellman, P.1    Chefd'hotel, C.2    Lorenz, C.H.3    Mancini, C.4    Arai, A.E.5    McVeigh, E.R.6
  • 8
    • 79951818098 scopus 로고    scopus 로고
    • Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI
    • Filipovic M, Vuissoz PA, Codreanu A, Claudon M, Felblinger J. Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI. Magn Reson Med 2011;65:812–822.
    • (2011) Magn Reson Med , vol.65 , pp. 812-822
    • Filipovic, M.1    Vuissoz, P.A.2    Codreanu, A.3    Claudon, M.4    Felblinger, J.5
  • 9
    • 81355161604 scopus 로고    scopus 로고
    • Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA
    • Schmidt JFM, Buehrer M, Boesiger P, Kozerke S. Nonrigid retrospective respiratory motion correction in whole-heart coronary MRA. Magn Reson Med 2011;66:1541–1549.
    • (2011) Magn Reson Med , vol.66 , pp. 1541-1549
    • Schmidt, J.F.M.1    Buehrer, M.2    Boesiger, P.3    Kozerke, S.4
  • 10
    • 82255164619 scopus 로고    scopus 로고
    • Motion compensated magnetic resonance reconstruction using inverse-consistent deformable registration: application to real-time cine imaging
    • Xue H, Ding Y, Guetter C, Jolly MP, Guehring J, Zuehlsdorff S, Simonetti OP. Motion compensated magnetic resonance reconstruction using inverse-consistent deformable registration: application to real-time cine imaging. Med Image Comput Comput Interv 2011;14:564–572.
    • (2011) Med Image Comput Comput Interv , vol.14 , pp. 564-572
    • Xue, H.1    Ding, Y.2    Guetter, C.3    Jolly, M.P.4    Guehring, J.5    Zuehlsdorff, S.6    Simonetti, O.P.7
  • 11
    • 84870880292 scopus 로고    scopus 로고
    • Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy
    • Brehm M, Paysan P, Oelhafen M, Kunz P, Kachelrieß M. Self-adapting cyclic registration for motion-compensated cone-beam CT in image-guided radiation therapy. Med Phys 2012;39:7603–7618.
    • (2012) Med Phys , vol.39 , pp. 7603-7618
    • Brehm, M.1    Paysan, P.2    Oelhafen, M.3    Kunz, P.4    Kachelrieß, M.5
  • 13
    • 84885310961 scopus 로고    scopus 로고
    • Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction
    • Moghari MH, Roujol S, Chan RH, et al. Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction. Magn Reson Med 2013;70:1005–1015.
    • (2013) Magn Reson Med , vol.70 , pp. 1005-1015
    • Moghari, M.H.1    Roujol, S.2    Chan, R.H.3
  • 14
    • 84885784095 scopus 로고    scopus 로고
    • Artifact-resistant motion estimation with a patient-specific artifact model for motion-compensated cone-beam CT
    • Brehm M, Paysan P, Oelhafen M, Kachelrieß M. Artifact-resistant motion estimation with a patient-specific artifact model for motion-compensated cone-beam CT. Med Phys 2013;40:101913–1–13.
    • (2013) Med Phys , vol.40 , pp. 101911-101913
    • Brehm, M.1    Paysan, P.2    Oelhafen, M.3    Kachelrieß, M.4
  • 15
    • 84885613379 scopus 로고    scopus 로고
    • Highly efficient 3D motion-compensated abdomen MRI from undersampled golden-RPE acquisitions
    • Buerger C, Prieto C, Schaeffter T. Highly efficient 3D motion-compensated abdomen MRI from undersampled golden-RPE acquisitions. Magn Reson Mater Physics, Biol Med 2013;26:419–429.
    • (2013) Magn Reson Mater Physics, Biol Med , vol.26 , pp. 419-429
    • Buerger, C.1    Prieto, C.2    Schaeffter, T.3
  • 17
    • 84927692410 scopus 로고    scopus 로고
    • Compressive manifold learning: estimating one-dimensional respiratory motion directly from undersampled k-Space data
    • Usman M, Vaillant G, Atkinson D, Schaeffer T, Prieto C. Compressive manifold learning: estimating one-dimensional respiratory motion directly from undersampled k-Space data. Magn Reson Med 2013;1140:1130–1140.
    • (2013) Magn Reson Med , vol.1140 , pp. 1130-1140
    • Usman, M.1    Vaillant, G.2    Atkinson, D.3    Schaeffer, T.4    Prieto, C.5
  • 18
    • 84932113153 scopus 로고    scopus 로고
    • Self-navigation with compressed sensing for 2D translational motion correction in free-breathing coronary MRI: a feasibility study
    • Bonanno G, Puy G, Wiaux Y, van Heeswijk RB, Piccini D, Stuber M. Self-navigation with compressed sensing for 2D translational motion correction in free-breathing coronary MRI: a feasibility study. PLoS One 2014;9:e105523.
    • (2014) PLoS One , vol.9
    • Bonanno, G.1    Puy, G.2    Wiaux, Y.3    van Heeswijk, R.B.4    Piccini, D.5    Stuber, M.6
  • 19
    • 84962620432 scopus 로고    scopus 로고
    • Accelerated motion corrected three-dimensional abdominal MRI using total variation regularized SENSE reconstruction
    • 75 1484–1498
    • Cruz G, Atkinson D, Buerger C, Schaeffter T, Prieto C. Accelerated motion corrected three-dimensional abdominal MRI using total variation regularized SENSE reconstruction. Magn Reson Med 2016;75: 1484–1498.
    • (2016) Magn Reson Med
    • Cruz, G.1    Atkinson, D.2    Buerger, C.3    Schaeffter, T.4    Prieto, C.5
  • 20
    • 84941952647 scopus 로고    scopus 로고
    • Comparison of image-based and reconstruction-based respiratory motion correction for golden radial phase encoding coronary MR angiography
    • Paschke NK, Dössel O, Schaeffter T, Prieto C, Kolbitsch C. Comparison of image-based and reconstruction-based respiratory motion correction for golden radial phase encoding coronary MR angiography. J Magn Reson Imaging 2015;42:964–971.
    • (2015) J Magn Reson Imaging , vol.42 , pp. 964-971
    • Paschke, N.K.1    Dössel, O.2    Schaeffter, T.3    Prieto, C.4    Kolbitsch, C.5
  • 24
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for Fourier inversion in computer tomography
    • O'Sullivan JD. A fast sinc function gridding algorithm for Fourier inversion in computer tomography. IEEE Trans Med Imaging 1985;4:200–207.
    • (1985) IEEE Trans Med Imaging , vol.4 , pp. 200-207
    • O'Sullivan, J.D.1
  • 25
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031–1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 26
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn Reson Med 2007;57:1086–1098.
    • (2007) Magn Reson Med , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 27
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: the application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182–1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 29
    • 60349105482 scopus 로고    scopus 로고
    • k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI
    • Jung H, Sung K, Nayak KS, Kim EY, Ye JC. k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI. Magn Reson Med 2009;61:103–116.
    • (2009) Magn Reson Med , vol.61 , pp. 103-116
    • Jung, H.1    Sung, K.2    Nayak, K.S.3    Kim, E.Y.4    Ye, J.C.5
  • 30
    • 73349136555 scopus 로고    scopus 로고
    • Radial k-t FOCUSS for high-resolution cardiac cine MRI
    • Jung H, Park J, Yoo J, Ye JC. Radial k-t FOCUSS for high-resolution cardiac cine MRI. Magn Reson Med 2010;63:68–78.
    • (2010) Magn Reson Med , vol.63 , pp. 68-78
    • Jung, H.1    Park, J.2    Yoo, J.3    Ye, J.C.4
  • 31
    • 77955586915 scopus 로고    scopus 로고
    • Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI
    • Otazo R, Kim D, Axel L, Sodickson D. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI. Magn Reson Med 2010;64:767–776.
    • (2010) Magn Reson Med , vol.64 , pp. 767-776
    • Otazo, R.1    Kim, D.2    Axel, L.3    Sodickson, D.4
  • 32
    • 79952977450 scopus 로고    scopus 로고
    • Improved total variation-based CT image reconstruction applied to clinical data
    • Ritschl L, Bergner F, Fleischmann C, Kachelrieß M. Improved total variation-based CT image reconstruction applied to clinical data. Phys Med Biol 2011;56:1545–1561.
    • (2011) Phys Med Biol , vol.56 , pp. 1545-1561
    • Ritschl, L.1    Bergner, F.2    Fleischmann, C.3    Kachelrieß, M.4
  • 33
    • 84858054757 scopus 로고    scopus 로고
    • Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior
    • Ritschl L, Sawall S, Knaup M, Hess A, Kachelrieß M. Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior. Phys Med Biol 2012;57:1517–1525.
    • (2012) Phys Med Biol , vol.57 , pp. 1517-1525
    • Ritschl, L.1    Sawall, S.2    Knaup, M.3    Hess, A.4    Kachelrieß, M.5
  • 34
    • 84871607756 scopus 로고    scopus 로고
    • Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling
    • Chandarana H, Feng L, Block TK, Rosenkrantz AB, Lim RP, Babb JS, Sodickson DK, Otazo R. Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling. Invest Radiol 2013;48:10–16.
    • (2013) Invest Radiol , vol.48 , pp. 10-16
    • Chandarana, H.1    Feng, L.2    Block, T.K.3    Rosenkrantz, A.B.4    Lim, R.P.5    Babb, J.S.6    Sodickson, D.K.7    Otazo, R.8
  • 35
    • 84885088263 scopus 로고    scopus 로고
    • Accelerating free breathing myocardial perfusion MRI using multi coil radial k - t SLR
    • Lingala SG, DiBella E, Adluru G, McGann C, Jacob M. Accelerating free breathing myocardial perfusion MRI using multi coil radial k - t SLR. Phys Med Biol 2013;58:7309–7327.
    • (2013) Phys Med Biol , vol.58 , pp. 7309-7327
    • Lingala, S.G.1    DiBella, E.2    Adluru, G.3    McGann, C.4    Jacob, M.5
  • 36
    • 85027934963 scopus 로고    scopus 로고
    • Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI
    • Feng L, Grimm R, Tobias Block K, Chandarana H, Kim S, Xu J, Axel L, Sodickson DK, Otazo R. Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI. Magn Reson Med 2014;72:707–717.
    • (2014) Magn Reson Med , vol.72 , pp. 707-717
    • Feng, L.1    Grimm, R.2    Tobias Block, K.3    Chandarana, H.4    Kim, S.5    Xu, J.6    Axel, L.7    Sodickson, D.K.8    Otazo, R.9
  • 37
    • 84904465647 scopus 로고    scopus 로고
    • Application of the compressed sensing technique to self-gated cardiac cine sequences in small animals
    • Montesinos P, Abascal JFPJ, Cussó L, Vaquero JJ, Desco M. Application of the compressed sensing technique to self-gated cardiac cine sequences in small animals. Magn Reson Med 2014;72:369–380.
    • (2014) Magn Reson Med , vol.72 , pp. 369-380
    • Montesinos, P.1    Abascal, J.F.P.J.2    Cussó, L.3    Vaquero, J.J.4    Desco, M.5
  • 38
    • 84941731601 scopus 로고    scopus 로고
    • XD-GRASP: golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing
    • Feng L, Axel L, Chandarana H, Block KT, Sodickson DK, Otazo R. XD-GRASP: golden-angle radial MRI with reconstruction of extra motion-state dimensions using compressed sensing. Magn Reson Med 2015.
    • (2015) Magn Reson Med
    • Feng, L.1    Axel, L.2    Chandarana, H.3    Block, K.T.4    Sodickson, D.K.5    Otazo, R.6
  • 39
    • 77953577585 scopus 로고    scopus 로고
    • Motion estimated and compensated compressed sensing dynamic magnetic resonance imaging: what we can learn from video compression techniques
    • Jung H, Ye JC. Motion estimated and compensated compressed sensing dynamic magnetic resonance imaging: what we can learn from video compression techniques. Int J Imaging Syst Technol 2010;20:81–98.
    • (2010) Int J Imaging Syst Technol , vol.20 , pp. 81-98
    • Jung, H.1    Ye, J.C.2
  • 40
    • 84920155292 scopus 로고    scopus 로고
    • Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI
    • Lingala S, DiBella E, Jacob M. Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI. IEEE Trans Med Imaging 2015;34:72–85.
    • (2015) IEEE Trans Med Imaging , vol.34 , pp. 72-85
    • Lingala, S.1    DiBella, E.2    Jacob, M.3
  • 41
    • 84883215678 scopus 로고    scopus 로고
    • Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI
    • Asif MS, Hamilton L, Brummer M, Romberg J. Motion-adaptive spatio-temporal regularization for accelerated dynamic MRI. Magn Reson Med 2013;70:800–812.
    • (2013) Magn Reson Med , vol.70 , pp. 800-812
    • Asif, M.S.1    Hamilton, L.2    Brummer, M.3    Romberg, J.4
  • 42
    • 0015116113 scopus 로고
    • Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms
    • Ramachandran GN, Lakshminarayanan A V. Three-dimensional reconstruction from radiographs and electron micrographs: application of convolutions instead of Fourier transforms. Proc Natl Acad Sci USA 1971;68:2236–2240.
    • (1971) Proc Natl Acad Sci USA , vol.68 , pp. 2236-2240
    • Ramachandran, G.N.1    Lakshminarayanan, A.2
  • 43
    • 0036187917 scopus 로고    scopus 로고
    • Combination of signals from array coils using image-based estimation of coil sensitivity profiles
    • Bydder M, Larkman DJ, Hajnal J V. Combination of signals from array coils using image-based estimation of coil sensitivity profiles. Magn Reson Med 2002;47:539–548.
    • (2002) Magn Reson Med , vol.47 , pp. 539-548
    • Bydder, M.1    Larkman, D.J.2    Hajnal, J.3
  • 44
    • 0032153006 scopus 로고    scopus 로고
    • Image matching as a diffusion process: an analogy with Maxwell's demons
    • Thirion J. Image matching as a diffusion process: an analogy with Maxwell's demons. Med Image Anal 1998;2:243–260.
    • (1998) Med Image Anal , vol.2 , pp. 243-260
    • Thirion, J.1
  • 45
    • 63849264858 scopus 로고    scopus 로고
    • Diffeomorphic demons: efficient non-parametric image registration
    • Vercauteren T, Pennec X, Perchant A, Ayache N. Diffeomorphic demons: efficient non-parametric image registration. NeuroImage 2009;45:S61–S72.
    • (2009) NeuroImage , vol.45 , pp. S61-S72
    • Vercauteren, T.1    Pennec, X.2    Perchant, A.3    Ayache, N.4
  • 46
    • 84857947577 scopus 로고    scopus 로고
    • Nonrigid motion modeling of the liver from 3-D undersampled self-gated golden-radial phase encoded MRI
    • Buerger C, Clough R. Nonrigid motion modeling of the liver from 3-D undersampled self-gated golden-radial phase encoded MRI. IEEE Trans Med Imaging 2012;31:805–815.
    • (2012) IEEE Trans Med Imaging , vol.31 , pp. 805-815
    • Buerger, C.1    Clough, R.2
  • 47
    • 84856951888 scopus 로고    scopus 로고
    • Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT
    • Vandemeulebroucke J, Bernard O, Rit S, Kybic J, Clarysse P, Sarrut D. Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT. Med Phys 2012;39:1006–1015.
    • (2012) Med Phys , vol.39 , pp. 1006-1015
    • Vandemeulebroucke, J.1    Bernard, O.2    Rit, S.3    Kybic, J.4    Clarysse, P.5    Sarrut, D.6
  • 50
    • 69249124598 scopus 로고    scopus 로고
    • Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI
    • Biederer J, Hintze C, Fabel M, Dinkel J. Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI. Radiologe 2009;49:705–711.
    • (2009) Radiologe , vol.49 , pp. 705-711
    • Biederer, J.1    Hintze, C.2    Fabel, M.3    Dinkel, J.4
  • 51
    • 78649639524 scopus 로고    scopus 로고
    • Magnetic resonance imaging and computed tomography of respiratory mechanics
    • Biederer J, Hintze C, Fabel M, Dinkel J. Magnetic resonance imaging and computed tomography of respiratory mechanics. J Magn Reson Imaging 2010;32:1388–1397.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 1388-1397
    • Biederer, J.1    Hintze, C.2    Fabel, M.3    Dinkel, J.4
  • 52
    • 33747623309 scopus 로고    scopus 로고
    • MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning
    • Blackall JM, Ahmad S, Miquel ME, McClelland JR, Landau DB, Hawkes DJ. MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning. Phys Med Biol 2006;51:4147–4169.
    • (2006) Phys Med Biol , vol.51 , pp. 4147-4169
    • Blackall, J.M.1    Ahmad, S.2    Miquel, M.E.3    McClelland, J.R.4    Landau, D.B.5    Hawkes, D.J.6
  • 54
    • 84870246864 scopus 로고    scopus 로고
    • Advances in 4D radiation therapy for managing respiration. Part I: 4D imaging
    • Hugo GD, Rosu M. Advances in 4D radiation therapy for managing respiration. Part I: 4D imaging. Z Med Phys 2012;22:258–271.
    • (2012) Z Med Phys , vol.22 , pp. 258-271
    • Hugo, G.D.1    Rosu, M.2
  • 55
  • 56
    • 84874915268 scopus 로고    scopus 로고
    • Respiratory motion correction in oncologic PET using T1-weighted MR imaging on a simultaneous whole-body PET/MR system
    • Würslin C, Schmidt H, Martirosian P, Brendle C, Boss A, Schwenzer NF, Stegger L. Respiratory motion correction in oncologic PET using T1-weighted MR imaging on a simultaneous whole-body PET/MR system. J Nucl Med 2013;54:464–471.
    • (2013) J Nucl Med , vol.54 , pp. 464-471
    • Würslin, C.1    Schmidt, H.2    Martirosian, P.3    Brendle, C.4    Boss, A.5    Schwenzer, N.F.6    Stegger, L.7
  • 57
    • 84924777801 scopus 로고    scopus 로고
    • The use of a generalized reconstruction by inversion of coupled systems (GRICS) approach for generic respiratory motion correction in PET/MR imaging
    • Fayad H, Odille F, Schmidt H, Würslin C, Küstner T, Feblinger J, Visvikis D. The use of a generalized reconstruction by inversion of coupled systems (GRICS) approach for generic respiratory motion correction in PET/MR imaging. Phys Med Biol 2015;60:2529–2546.
    • (2015) Phys Med Biol , vol.60 , pp. 2529-2546
    • Fayad, H.1    Odille, F.2    Schmidt, H.3    Würslin, C.4    Küstner, T.5    Feblinger, J.6    Visvikis, D.7
  • 58
    • 84930356530 scopus 로고    scopus 로고
    • Reconstruction incorporated respiratory motion correction in clinical simultaneous PET/MR imaging for oncology applications
    • Fayad H, Schmidt H, Wurslin C, Visvikis D. Reconstruction incorporated respiratory motion correction in clinical simultaneous PET/MR imaging for oncology applications. J Nucl Med 2015;56:884–889.
    • (2015) J Nucl Med , vol.56 , pp. 884-889
    • Fayad, H.1    Schmidt, H.2    Wurslin, C.3    Visvikis, D.4
  • 60
    • 84949115320 scopus 로고    scopus 로고
    • Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI
    • Grimm R, Fürst S, Souvatzoglou M, et al. Self-gated MRI motion modeling for respiratory motion compensation in integrated PET/MRI. Med Image Anal 2015;19:110–120.
    • (2015) Med Image Anal , vol.19 , pp. 110-120
    • Grimm, R.1    Fürst, S.2    Souvatzoglou, M.3
  • 61
    • 84943329450 scopus 로고    scopus 로고
    • Respiratory motion compensation for simultaneous PET/MR based on a 3D-2D registration of strongly undersampled radial MR data: a simulation study
    • Rank CM, Heußer T, Flach B, Brehm M, Kachelrieß M. Respiratory motion compensation for simultaneous PET/MR based on a 3D-2D registration of strongly undersampled radial MR data: a simulation study. Proc SPIE Med Imaging 2015;9412:941218–1–8.
    • (2015) Proc SPIE Med Imaging , vol.9412
    • Rank, C.M.1    Heußer, T.2    Flach, B.3    Brehm, M.4    Kachelrieß, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.