메뉴 건너뛰기




Volumn 57, Issue 6, 2012, Pages 1517-1525

Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFACT REDUCTION; COMPUTED TOMOGRAPHY; CONSTRAINED RECONSTRUCTION; DATA SETS; FDK ALGORITHM; HIGHER-DIMENSIONAL; IN-VIVO; MEASURED SIGNALS; MICRO CT; MOTION ARTIFACT; MOTION PHASIS; PRIORI KNOWLEDGE; SPATIAL DOMAINS; SPATIO-TEMPORAL; STANDARD METHOD; TEMPORAL DOMAIN; TEMPORAL RESOLUTION; TOTAL VARIATION; UNDER-SAMPLING;

EID: 84858054757     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/6/1517     Document Type: Article
Times cited : (68)

References (15)
  • 1
    • 0021344602 scopus 로고
    • Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm
    • Andersen A H and Kak A C 1984 Simultaneous algebraic reconstruction technique (SART): a superior implementation of the ART algorithm Ultrason. Imaging 6 8194 (Pubitemid 14139189)
    • (1984) Ultrasonic Imaging , vol.6 , Issue.1 , pp. 81-94
    • Andersen, A.H.1    Kak, A.C.2
  • 3
    • 38849164794 scopus 로고    scopus 로고
    • Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets
    • DOI 10.1118/1.2836423
    • Chen G-H, Tang J and Leng S 2008 Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets Med. Phys. 35 6603 (Pubitemid 351190885)
    • (2008) Medical Physics , vol.35 , Issue.2 , pp. 660-663
    • Chen, G.-H.1    Tang, J.2    Leng, S.3
  • 6
    • 0035996436 scopus 로고    scopus 로고
    • Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart
    • DOI 10.1118/1.1487861
    • Kachelrie M, Sennst D A, Maxlmoser W and Kalender W A 2002 Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart Med. Phys. 29 1489503 (Pubitemid 34774581)
    • (2002) Medical Physics , vol.29 , Issue.7 , pp. 1489-1503
    • Kachelriess, M.1    Sennst, D.-A.2    Maxlmoser, W.3    Kalender, W.A.4
  • 7
    • 33646460131 scopus 로고    scopus 로고
    • Empirical cupping correction: A first order raw data precorrection for cone-beam computed tomography
    • Kachelrie M, Sourbelle K and Kalender W 2006 Empirical cupping correction: a first order raw data precorrection for cone-beam computed tomography Med. Phys. 33 126974
    • (2006) Med. Phys. , vol.33 , pp. 1269-1274
    • Kachelrie, M.1    Sourbelle, K.2    Kalender, W.3
  • 8
    • 0035104021 scopus 로고    scopus 로고
    • Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
    • DOI 10.1088/0031-9155/46/3/318, PII S0031915501164493
    • Persson M, Bone D and Elmquist H 2001 Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography Phys. Med. Biol. 28 85366 (Pubitemid 32219728)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.3 , pp. 853-866
    • Persson, M.1    Bone, D.2    Elmqvist, H.3
  • 9
    • 79952977450 scopus 로고    scopus 로고
    • Improved total variation-based CT image reconstruction applied to clinical data
    • Ritschl L, Bergner F, Fleischmann C and Kachelrie M 2011 Improved total variation-based CT image reconstruction applied to clinical data Phys. Med. Biol. 56 154561
    • (2011) Phys. Med. Biol. , vol.56 , pp. 1545-1561
    • Ritschl, L.1    Bergner, F.2    Fleischmann, C.3    Kachelrie, M.4
  • 10
    • 44049111982 scopus 로고
    • Nonlinear total variation based noise removal algorithms
    • Rudin L, Osher S and Fatemi E 1992 Nonlinear total variation based noise removal algorithms J. Phys. D: Appl. Phys. 60 25968
    • (1992) J. Phys. D: Appl. Phys. , vol.60 , pp. 259-268
    • Rudin, L.1    Osher, S.2    Fatemi, E.3
  • 12
    • 33745162201 scopus 로고    scopus 로고
    • Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
    • Sidky E Y, Kao C and Pan X 2006 Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT J. X-Ray Sci. Technol. 14 11939 (Pubitemid 43893801)
    • (2006) Journal of X-Ray Science and Technology , vol.14 , Issue.2 , pp. 119-139
    • Sidky, E.Y.1    Kao, C.-M.2    Pan, X.3
  • 13
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam computed tomography by total variation minimization
    • Sidky E Y and Pan X 2008 Image reconstruction in circular cone-beam computed tomography by total variation minimization Phys. Med. Biol. 53 4777807
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4777-4807
    • Sidky, E.Y.1    Pan, X.2
  • 14
    • 35648981849 scopus 로고    scopus 로고
    • Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT
    • DOI 10.1118/1.2795830
    • Song J, Liu Q H, Johnson G A and Badea C T 2007 Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro-CT Med. Phys. 34 447683 (Pubitemid 350029668)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4476-4483
    • Song, J.1    Liu, Q.H.2    Johnson, G.A.3    Badea, C.T.4
  • 15
    • 79952131914 scopus 로고    scopus 로고
    • Low-dose 4DCT reconstruction via temporal nonlocal means
    • Tian Z, Jia X, Dong B, Lou Y and Jiang S B 2011 Low-dose 4DCT reconstruction via temporal nonlocal means Med. Phys. 38 135965
    • (2011) Med. Phys. , vol.38 , pp. 1359-1365
    • Tian, Z.1    Jia, X.2    Dong, B.3    Lou, Y.4    Jiang, S.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.