메뉴 건너뛰기




Volumn 64, Issue 3, 2010, Pages 767-776

Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI

Author keywords

Cardiac perfusion; Compressed sensing; Dynamic imaging; Joint sparsity; Parallel imaging

Indexed keywords

ACCELERATION; COMPRESSED SENSING; HEART;

EID: 77955586915     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22463     Document Type: Article
Times cited : (502)

References (34)
  • 1
    • 0025269066 scopus 로고
    • First-pass cardiac perfusion: Evaluation with ultrafast MR imaging
    • Atkinson DJ, Burstein D, Edelman RR. First-pass cardiac perfusion: evaluation with ultrafast MR imaging. Radiology 1990;174:757-762.
    • (1990) Radiology , vol.174 , pp. 757-762
    • Atkinson, D.J.1    Burstein, D.2    Edelman, R.R.3
  • 3
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45:846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 4
    • 16444385871 scopus 로고    scopus 로고
    • Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
    • Breuer FA, Kellman P, Griswold MA, Jakob PM. Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA). Magn Reson Med 2005;53:981-985.
    • (2005) Magn Reson Med , vol.53 , pp. 981-985
    • Breuer, F.A.1    Kellman, P.2    Griswold, M.A.3    Jakob, P.M.4
  • 5
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 7
    • 34248230856 scopus 로고    scopus 로고
    • Improving k-t SENSE by adaptive regularization
    • Xu D, King KF, Liang ZP. Improving k-t SENSE by adaptive regularization. Magn Reson Med 2007;57:918-930.
    • (2007) Magn Reson Med , vol.57 , pp. 918-930
    • Xu, D.1    King, K.F.2    Liang, Z.P.3
  • 8
    • 36248935661 scopus 로고    scopus 로고
    • MR myocardial perfusion imaging with k-space and time broad-use linear acquisition speed-up technique: Feasibility study
    • Gebker R, Jahnke C, Paetsch I, Schnackenburg B, Kozerke S, Bornstedt A, Fleck E, Nagel E. MR myocardial perfusion imaging with k-space and time broad-use linear acquisition speed-up technique: feasibility study. Radiology 2007;245:863-871.
    • (2007) Radiology , vol.245 , pp. 863-871
    • Gebker, R.1    Jahnke, C.2    Paetsch, I.3    Schnackenburg, B.4    Kozerke, S.5    Bornstedt, A.6    Fleck, E.7    Nagel, E.8
  • 11
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58:1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 14
    • 60349105482 scopus 로고    scopus 로고
    • k-t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
    • Jung H, Sung K, Nayak KS, Kim EY, Ye JC. k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI. Magn Reson Med 2009;61:103-116.
    • (2009) Magn Reson Med , vol.61 , pp. 103-116
    • Jung, H.1    Sung, K.2    Nayak, K.S.3    Kim, E.Y.4    Ye, J.C.5
  • 16
    • 30844458202 scopus 로고    scopus 로고
    • Extensions of compressed sensing
    • Tsaig Y, Donoho DL. Extensions of compressed sensing. Signal Process 2006;86:533-548.
    • (2006) Signal Process , vol.86 , pp. 533-548
    • Tsaig, Y.1    Donoho, D.L.2
  • 17
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 24
    • 73149123165 scopus 로고    scopus 로고
    • Accelerating SENSE using compressed sensing
    • Liang D, Liu B, Wang J, Ying L. Accelerating SENSE using compressed sensing. Magn Reson Med 2009;62:1574-1584.
    • (2009) Magn Reson Med , vol.62 , pp. 1574-1584
    • Liang, D.1    Liu, B.2    Wang, J.3    Ying, L.4
  • 29
    • 37549070776 scopus 로고    scopus 로고
    • Comparison of the effectiveness of saturation pulses in the heart at 3T
    • Kim D, Gonen O, Oesingmann N, Axel L. Comparison of the effectiveness of saturation pulses in the heart at 3T. Magn Reson Med 2008;59:209-215.
    • (2008) Magn Reson Med , vol.59 , pp. 209-215
    • Kim, D.1    Gonen, O.2    Oesingmann, N.3    Axel, L.4
  • 30
    • 37549026541 scopus 로고    scopus 로고
    • Influence of the k-space trajectory on the dynamic T1-weighted signal in quantitative first-pass cardiac perfusion MRI at 3T
    • Kim D. Influence of the k-space trajectory on the dynamic T1-weighted signal in quantitative first-pass cardiac perfusion MRI at 3T. Magn Reson Med 2008;59:202-208.
    • (2008) Magn Reson Med , vol.59 , pp. 202-208
    • Kim, D.1
  • 31
    • 0036163292 scopus 로고    scopus 로고
    • Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement
    • Kellman P, Arai AE, McVeigh ER, Aletras AH. Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement. Magn Reson Med 2002;47:372-383.
    • (2002) Magn Reson Med , vol.47 , pp. 372-383
    • Kellman, P.1    Arai, A.E.2    McVeigh, E.R.3    Aletras, A.H.4
  • 33
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Börnert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Börnert, P.3    Boesiger, P.4
  • 34
    • 58049195322 scopus 로고    scopus 로고
    • Highly undersampled magnetic resonance image reconstruction via homotopic l(0)-minimization
    • Trzasko J, Manduca A. Highly undersampled magnetic resonance image reconstruction via homotopic l(0)-minimization. IEEE Trans Med Imaging 2009;28:106-121.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 106-121
    • Trzasko, J.1    Manduca, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.