메뉴 건너뛰기




Volumn 26, Issue 5, 2013, Pages 419-429

Highly efficient 3D motion-compensated abdomen MRI from undersampled golden-RPE acquisitions

Author keywords

Liver; Motion compensation; Motion model; Non rigid registration; Retrospective reconstruction; RPE; Undersampling

Indexed keywords

ARTICLE; ARTIFACT; BREATHING; HUMAN; IMAGE PROCESSING; LIVER; METHODOLOGY; MOVEMENT (PHYSIOLOGY); NORMAL DISTRIBUTION; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; REPRODUCIBILITY; THEORETICAL MODEL; THREE DIMENSIONAL IMAGING; TIME;

EID: 84885613379     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-013-0370-y     Document Type: Article
Times cited : (25)

References (19)
  • 1
    • 53349109117 scopus 로고    scopus 로고
    • Imaging of liver disease: Comparison between quadruple-phase multidetector computed tomography and magnetic resonance imaging
    • 18713303 10.1111/j.1440-1746.2008.05434.x
    • Balci NC, Befeler AS, Leiva P, Pilgram TK, Havlioglu N (2008) Imaging of liver disease: comparison between quadruple-phase multidetector computed tomography and magnetic resonance imaging. J Gastroenterol Hepatol 23(10):1520-1527
    • (2008) J Gastroenterol Hepatol , vol.23 , Issue.10 , pp. 1520-1527
    • Balci, N.C.1    Befeler, A.S.2    Leiva, P.3    Pilgram, T.K.4    Havlioglu, N.5
  • 2
    • 78650635391 scopus 로고    scopus 로고
    • Evaluation of respiratory liver and kidney movements for MRI navigator gating
    • 21182132 10.1002/jmri.22418
    • Song R, Tipirneni A, Johnson P, Loeffler RB, Hillenbrand CM (2011) Evaluation of respiratory liver and kidney movements for MRI navigator gating. J Magn Reson Imaging 33(1):143-148
    • (2011) J Magn Reson Imaging , vol.33 , Issue.1 , pp. 143-148
    • Song, R.1    Tipirneni, A.2    Johnson, P.3    Loeffler, R.B.4    Hillenbrand, C.M.5
  • 3
    • 0030026702 scopus 로고    scopus 로고
    • Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography
    • 8539406 1:STN:280:DyaK287itlWnsQ%3D%3D
    • Wang Y, Rossman PJ, Grimm RC, Riederer SJ, Ehman RL (1996) Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. Radiology 198(1):55-60
    • (1996) Radiology , vol.198 , Issue.1 , pp. 55-60
    • Wang, Y.1    Rossman, P.J.2    Grimm, R.C.3    Riederer, S.J.4    Ehman, R.L.5
  • 4
    • 0034006547 scopus 로고    scopus 로고
    • Phase ordering with automatic window selection (PAWS): A novel motion-resistant technique for 3D coronary imaging
    • 10725891 10.1002/(SICI)1522-2594(200003)43:3<470: AID-MRM20>3.0. CO;2-U 1:STN:280:DC%2BD3c3gtFCgsQ%3D%3D
    • Jhooti P, Gatehouse PD, Keegan J, Bunce NH, Taylor AM, Firmin DN (2000) Phase ordering with automatic window selection (PAWS): a novel motion-resistant technique for 3D coronary imaging. Magn Reson Med 43(3):470-480
    • (2000) Magn Reson Med , vol.43 , Issue.3 , pp. 470-480
    • Jhooti, P.1    Gatehouse, P.D.2    Keegan, J.3    Bunce, N.H.4    Taylor, A.M.5    Firmin, D.N.6
  • 5
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • 12928954 10.1007/s00330-003-1957-x
    • Scheffler K, Lehnhardt S (2003) Principles and applications of balanced SSFP techniques. Eur Radiol 13:2409-2418
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 6
    • 44949196855 scopus 로고    scopus 로고
    • Respiratory self-gated four-dimensional coronary MR angiography: A feasibility study
    • 18506786 10.1002/mrm.21617
    • Lai P, Larson AC, Park J, Carr JC, Li D (2008) Respiratory self-gated four-dimensional coronary MR angiography: a feasibility study. Magn Reson Med 59(6):1378-1385
    • (2008) Magn Reson Med , vol.59 , Issue.6 , pp. 1378-1385
    • Lai, P.1    Larson, A.C.2    Park, J.3    Carr, J.C.4    Li, D.5
  • 8
    • 77955114700 scopus 로고    scopus 로고
    • 3D undersampled golden-radial phase encoding for DCE-MRA using inherently regularized iterative SENSE
    • 20665795
    • Prieto C, Uribe S, Razavi R, Atkinson D, Schaeffter T (2010) 3D undersampled golden-radial phase encoding for DCE-MRA using inherently regularized iterative SENSE. Magn Reson Med 64(2):514-526
    • (2010) Magn Reson Med , vol.64 , Issue.2 , pp. 514-526
    • Prieto, C.1    Uribe, S.2    Razavi, R.3    Atkinson, D.4    Schaeffter, T.5
  • 9
    • 84857947577 scopus 로고    scopus 로고
    • Nonrigid Motion Modeling of the Liver from 3-D Undersampled Self-Gated Golden-Radial Phase Encoded MRI
    • 22271830 10.1109/TMI.2011.2181997 1:STN:280:DC%2BC383otFGitA%3D%3D
    • Buerger C, Clough RE, King AP, Schaeffter T, Prieto C (2012) Nonrigid Motion Modeling of the Liver From 3-D Undersampled Self-Gated Golden-Radial Phase Encoded MRI. IEEE Trans Med Imaging 31(3):805-815
    • (2012) IEEE Trans Med Imaging , vol.31 , Issue.3 , pp. 805-815
    • Buerger, C.1    Clough, R.E.2    King, A.P.3    Schaeffter, T.4    Prieto, C.5
  • 11
    • 33846246695 scopus 로고    scopus 로고
    • An optimal radial profile order based on the Golden Ratio for time-resolved MRI
    • 17243585 10.1109/TMI.2006.885337
    • Winkelmann S, Schaeffter T, Koehler T, Eggers H, Doessel O (2007) An optimal radial profile order based on the Golden Ratio for time-resolved MRI. IEEE Trans Med Imaging 26(1):68-76
    • (2007) IEEE Trans Med Imaging , vol.26 , Issue.1 , pp. 68-76
    • Winkelmann, S.1    Schaeffter, T.2    Koehler, T.3    Eggers, H.4    Doessel, O.5
  • 13
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • 10542355 10.1002/(SICI)1522-2594(199911)42:5<952: AID-MRM16>3.0. CO;2-S 1:STN:280:DC%2BD3c%2FhtFCruw%3D%3D
    • Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P (1999) SENSE: sensitivity Encoding for Fast MRI. Magn Reson Med 42:952-962
    • (1999) Magn Reson Med , vol.42 , pp. 952-962
    • Pruessmann, K.P.1    Weiger, M.2    Scheidegger, M.B.3    Boesiger, P.4
  • 14
    • 79958770897 scopus 로고    scopus 로고
    • Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation
    • 21454119 10.1016/j.media.2011.02.009
    • Buerger C, Schaeffter T, King AP (2011) Hierarchical adaptive local affine registration for fast and robust respiratory motion estimation. Med Image Anal 15:551-564
    • (2011) Med Image Anal , vol.15 , pp. 551-564
    • Buerger, C.1    Schaeffter, T.2    King, A.P.3
  • 15
    • 41849129269 scopus 로고    scopus 로고
    • Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging
    • 18302227 10.1002/mrm.21509
    • Kellman P, Chefd'hotel C, Lorenz C, Mancini C, Arai AE, McVeigh ER (2008) Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med 59(4):771-778
    • (2008) Magn Reson Med , vol.59 , Issue.4 , pp. 771-778
    • Kellman, P.1    Chefd'Hotel, C.2    Lorenz, C.3    Mancini, C.4    Arai, A.E.5    McVeigh, E.R.6
  • 16
    • 0033594967 scopus 로고    scopus 로고
    • Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA
    • 10377077 10.1161/01.CIR.99.24.3139 1:STN:280:DyaK1MzgslSmuw%3D%3D
    • Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ (1999) Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation 99(24):3139-3148
    • (1999) Circulation , vol.99 , Issue.24 , pp. 3139-3148
    • Botnar, R.M.1    Stuber, M.2    Danias, P.G.3    Kissinger, K.V.4    Manning, W.J.5
  • 17
    • 0032173355 scopus 로고    scopus 로고
    • Predicting error in rigid-body point-based registration
    • 9874293 10.1109/42.736021 1:STN:280:DyaK1M%2FovFKruw%3D%3D
    • Fitzpatrick JM, West JB, Maurer CR Jr (1998) Predicting error in rigid-body point-based registration. IEEE Trans Med Imaging 17(5):694-702
    • (1998) IEEE Trans Med Imaging , vol.17 , Issue.5 , pp. 694-702
    • Fitzpatrick, J.M.1    West, J.B.2    Maurer, Jr.C.R.3
  • 18
    • 80052687975 scopus 로고    scopus 로고
    • Multi-view 3D echocardiography compounding based on feature consistency
    • 21873770 10.1088/0031-9155/56/18/020
    • Yao C, Simpson JM, Schaeffter T, Penney GP (2011) Multi-view 3D echocardiography compounding based on feature consistency. Phys Med Biol 56:6109-6128
    • (2011) Phys Med Biol , vol.56 , pp. 6109-6128
    • Yao, C.1    Simpson, J.M.2    Schaeffter, T.3    Penney, G.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.