메뉴 건너뛰기




Volumn 72, Issue 3, 2014, Pages 707-717

Golden-angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI

Author keywords

compressed sensing; dynamic imaging; golden angle; joint sparsity; parallel imaging; radial sampling

Indexed keywords

COMPRESSED SENSING; ITERATIVE METHODS; MEDICAL IMAGING; TIME SERIES;

EID: 85027934963     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24980     Document Type: Article
Times cited : (607)

References (42)
  • 1
    • 0036794518 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced MRI in clinical oncology: Current status and future directions
    • Padhani AR,. Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions. J Magn Reson Imaging 2002; 16: 407-422.
    • (2002) J Magn Reson Imaging , vol.16 , pp. 407-422
    • Padhani, A.R.1
  • 2
    • 84872954393 scopus 로고    scopus 로고
    • Fast 3D contrast enhanced MRI of the liver using temporal resolution acceleration with constrained evolution reconstruction
    • Xu B, Spincemaille P, Chen G, Agrawal M, Nguyen TD, Prince MR, Wang Y,. Fast 3D contrast enhanced MRI of the liver using temporal resolution acceleration with constrained evolution reconstruction. Magn Reson Med 2013; 69: 370-381.
    • (2013) Magn Reson Med , vol.69 , pp. 370-381
    • Xu, B.1    Spincemaille, P.2    Chen, G.3    Agrawal, M.4    Nguyen, T.D.5    Prince, M.R.6    Wang, Y.7
  • 3
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ,. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 6
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER,. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001; 45: 846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 7
    • 16444385871 scopus 로고    scopus 로고
    • Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
    • Breuer FA, Kellman P, Griswold MA, Jakob PM,. Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA). Magn Reson Med 2005; 53: 981-985.
    • (2005) Magn Reson Med , vol.53 , pp. 981-985
    • Breuer, F.A.1    Kellman, P.2    Griswold, M.A.3    Jakob, P.M.4
  • 8
    • 84865314808 scopus 로고    scopus 로고
    • MRI temporal acceleration techniques
    • Tsao J, Kozerke S,. MRI temporal acceleration techniques. J Magn Reson Imaging 2012; 36: 543-560.
    • (2012) J Magn Reson Imaging , vol.36 , pp. 543-560
    • Tsao, J.1    Kozerke, S.2
  • 9
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP,. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003; 50: 1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 10
    • 27644503134 scopus 로고    scopus 로고
    • K-t GRAPPA: A k-space implementation for dynamic MRI with high reduction factor
    • Huang F, Akao J, Vijayakumar S, Duensing GR, Limkeman M,. k-t GRAPPA: a k-space implementation for dynamic MRI with high reduction factor. Magn Reson Med 2005; 54: 1172-1184.
    • (2005) Magn Reson Med , vol.54 , pp. 1172-1184
    • Huang, F.1    Akao, J.2    Vijayakumar, S.3    Duensing, G.R.4    Limkeman, M.5
  • 11
    • 34248230856 scopus 로고    scopus 로고
    • Improving k-t SENSE by adaptive regularization
    • Xu D, King KF, Liang ZP,. Improving k-t SENSE by adaptive regularization. Magn Reson Med 2007; 57: 918-930.
    • (2007) Magn Reson Med , vol.57 , pp. 918-930
    • Xu, D.1    King, K.F.2    Liang, Z.P.3
  • 14
    • 31744440684 scopus 로고    scopus 로고
    • Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
    • Candes E, Romberg JT,. Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information. IEEE Trans Inf Theory 2006; 52: 489-509.
    • (2006) IEEE Trans Inf Theory , vol.52 , pp. 489-509
    • Candes, E.1    Romberg, J.T.2
  • 15
    • 33645712892 scopus 로고    scopus 로고
    • Compressed sensing
    • Donoho D,. Compressed sensing. IEEE Trans Inf Theory 2006; 52: 1289-1306.
    • (2006) IEEE Trans Inf Theory , vol.52 , pp. 1289-1306
    • Donoho, D.1
  • 16
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 17
  • 20
    • 60349105482 scopus 로고    scopus 로고
    • K-t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
    • Jung H, Sung K, Nayak KS, Kim EY, Ye JC,. k-t FOCUSS: a general compressed sensing framework for high resolution dynamic MRI. Magn Reson Med 2009; 61: 103-116.
    • (2009) Magn Reson Med , vol.61 , pp. 103-116
    • Jung, H.1    Sung, K.2    Nayak, K.S.3    Kim, E.Y.4    Ye, J.C.5
  • 21
    • 77955586915 scopus 로고    scopus 로고
    • Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI
    • Otazo R, Kim D, Axel L, Sodickson DK,. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI. Magn Reson Med 2010; 64: 767-776.
    • (2010) Magn Reson Med , vol.64 , pp. 767-776
    • Otazo, R.1    Kim, D.2    Axel, L.3    Sodickson, D.K.4
  • 22
    • 79958271733 scopus 로고    scopus 로고
    • Accelerated cardiac T2 mapping using breath-hold multiecho fast spin-echo pulse sequence with k-t FOCUSS
    • Feng L, Otazo R, Jung H, Jensen JH, Ye JC, Sodickson DK, Kim D,. Accelerated cardiac T2 mapping using breath-hold multiecho fast spin-echo pulse sequence with k-t FOCUSS. Magn Reson Med 2011; 65: 1661-1669.
    • (2011) Magn Reson Med , vol.65 , pp. 1661-1669
    • Feng, L.1    Otazo, R.2    Jung, H.3    Jensen, J.H.4    Ye, J.C.5    Sodickson, D.K.6    Kim, D.7
  • 25
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J,. Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint. Magn Reson Med 2007; 57: 1086-1098.
    • (2007) Magn Reson Med , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 26
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM,. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992; 28: 275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 27
    • 0030047957 scopus 로고    scopus 로고
    • Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints
    • Gai N, Axel L,. Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints. Med Phys 1996; 23: 251-262.
    • (1996) Med Phys , vol.23 , pp. 251-262
    • Gai, N.1    Axel, L.2
  • 29
    • 84856219987 scopus 로고    scopus 로고
    • The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI
    • Chan RW, Ramsay EA, Cheung EY, Plewes DB,. The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI. Magn Reson Med 2012; 67: 363-377.
    • (2012) Magn Reson Med , vol.67 , pp. 363-377
    • Chan, R.W.1    Ramsay, E.A.2    Cheung, E.Y.3    Plewes, D.B.4
  • 31
    • 84865478167 scopus 로고    scopus 로고
    • Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction
    • Hansen MS, Sorensen TS, Arai AE, Kellman P,. Retrospective reconstruction of high temporal resolution cine images from real-time MRI using iterative motion correction. Magn Reson Med 2012; 68: 741-750.
    • (2012) Magn Reson Med , vol.68 , pp. 741-750
    • Hansen, M.S.1    Sorensen, T.S.2    Arai, A.E.3    Kellman, P.4
  • 32
    • 77955114700 scopus 로고    scopus 로고
    • 3D undersampled golden-radial phase encoding for DCE-MRA using inherently regularized iterative SENSE
    • Prieto C, Uribe S, Razavi R, Atkinson D, Schaeffter T,. 3D undersampled golden-radial phase encoding for DCE-MRA using inherently regularized iterative SENSE. Magn Reson Med 2010; 64: 514-526.
    • (2010) Magn Reson Med , vol.64 , pp. 514-526
    • Prieto, C.1    Uribe, S.2    Razavi, R.3    Atkinson, D.4    Schaeffter, T.5
  • 33
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • Walsh DO, Gmitro AF, Marcellin MW,. Adaptive reconstruction of phased array MR imagery. Magn Reson Med 2000; 43: 682-690.
    • (2000) Magn Reson Med , vol.43 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 34
    • 33744540030 scopus 로고    scopus 로고
    • The use of an adaptive reconstruction for array coil sensitivity mapping and intensity normalization
    • Honolulu, Hawaii, USA, Abstract 2410
    • Griswold MA WD, Heidemann RM, Haase A, Jakob PM,. The use of an adaptive reconstruction for array coil sensitivity mapping and intensity normalization. In Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, Hawaii, USA, 2002. Abstract 2410.
    • (2002) Proceedings of the 10th Annual Meeting of ISMRM
    • Griswold, M.A.W.1    Heidemann, R.M.2    Haase, A.3    Jakob, P.M.4
  • 36
    • 0002806690 scopus 로고    scopus 로고
    • An industry standard API for shared-memory programming
    • Dagum L, Open MP,. An industry standard API for shared-memory programming. IEEE Comput Sci Eng 1998; 5: 46-55.
    • (1998) IEEE Comput Sci Eng , vol.5 , pp. 46-55
    • Dagum, L.1    Open, M.P.2
  • 37
    • 84966262179 scopus 로고
    • Updating quasi-Newton matrices with limited storage
    • Nocedal J,. Updating quasi-Newton matrices with limited storage. Math Comput 1980; 35: 773-782.
    • (1980) Math Comput , vol.35 , pp. 773-782
    • Nocedal, J.1
  • 38
    • 84864660643 scopus 로고    scopus 로고
    • Simple method for adaptive gradient-delay compensation in radial MRI
    • Montreal, Canada
    • Block KT, Uecker M,. Simple method for adaptive gradient-delay compensation in radial MRI. In Proceedings of the 19th Annual Meeting of ISMRM, Montreal, Canada, 2011. p. 2816.
    • (2011) Proceedings of the 19th Annual Meeting of ISMRM , pp. 2816
    • Block, K.T.1    Uecker, M.2
  • 39
    • 85091617569 scopus 로고    scopus 로고
    • High spatial and temporal resolution 2D real time and 3D whole-heart cardiac cine MRI using compressed sensing and parallel imaging with golden angle radial trajectory
    • Melbourne, Australia
    • Feng L, Xu J, Axel L, Sodickson DK, Otazo R,. High spatial and temporal resolution 2D real time and 3D whole-heart cardiac cine MRI using compressed sensing and parallel imaging with golden angle radial trajectory. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 2012. p. 225.
    • (2012) Proceedings of the 20th Annual Meeting of ISMRM , pp. 225
    • Feng, L.1    Xu, J.2    Axel, L.3    Sodickson, D.K.4    Otazo, R.5
  • 40
    • 80052466239 scopus 로고    scopus 로고
    • Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: A viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration
    • Chandarana H, Block TK, Rosenkrantz AB, Lim RP, Kim D, Mossa DJ, Babb JS, Kiefer B, Lee VS,. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration. Invest Radiol 2011; 46: 648-653.
    • (2011) Invest Radiol , vol.46 , pp. 648-653
    • Chandarana, H.1    Block, T.K.2    Rosenkrantz, A.B.3    Lim, R.P.4    Kim, D.5    Mossa, D.J.6    Babb, J.S.7    Kiefer, B.8    Lee, V.S.9
  • 41
    • 84871607756 scopus 로고    scopus 로고
    • Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling
    • Chandarana H, Feng L, Block KT, Rosenkrantz AB, Lim P, Babb J, Sodickson DK, Otazo R,. Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling. Invest Radiol 2013; 48: 10-16.
    • (2013) Invest Radiol , vol.48 , pp. 10-16
    • Chandarana, H.1    Feng, L.2    Block, K.T.3    Rosenkrantz, A.B.4    Lim, P.5    Babb, J.6    Sodickson, D.K.7    Otazo, R.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.