-
1
-
-
0000369227
-
Steady-state free precession in nuclear magnetic resonance
-
Carr HY. Steady-state free precession in nuclear magnetic resonance. Phys Rev 1958;112:1693-1701.
-
(1958)
Phys Rev
, vol.112
, pp. 1693-1701
-
-
Carr, H.Y.1
-
2
-
-
0034870344
-
Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented k-space gradient-echo imaging
-
Plein S, Bloomer TN, Ridgway JP, Jones TR, Bainbridge GJ, Sivananthan MU. Steady-state free precession magnetic resonance imaging of the heart: Comparison with segmented k-space gradient-echo imaging. J Magn Reson Imaging 2001;14:230-236.
-
(2001)
J Magn Reson Imaging
, vol.14
, pp. 230-236
-
-
Plein, S.1
Bloomer, T.N.2
Ridgway, J.P.3
Jones, T.R.4
Bainbridge, G.J.5
Sivananthan, M.U.6
-
4
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
-
Sodickwon DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
-
(1997)
Magn Reson Med
, vol.38
, pp. 591-603
-
-
Sodickwon, D.K.1
Manning, W.J.2
-
5
-
-
0036263907
-
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
-
Griswold MA, Jakob PM, Heidemann RM, Nittka M, Jellus V, Wang J, Kiefer B, Haase A. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002;47:1202-1210.
-
(2002)
Magn Reson Med
, vol.47
, pp. 1202-1210
-
-
Griswold, M.A.1
Jakob, P.M.2
Heidemann, R.M.3
Nittka, M.4
Jellus, V.5
Wang, J.6
Kiefer, B.7
Haase, A.8
-
6
-
-
0033772492
-
Partially parallel imaging with localized sensitivities (PILS)
-
Griswold MA, Jakob PM, Nittka M, Goldfarb JW, Haase A. Partially parallel imaging with localized sensitivities (PILS). Magn Reson Med 2000;44:602-609.
-
(2000)
Magn Reson Med
, vol.44
, pp. 602-609
-
-
Griswold, M.A.1
Jakob, P.M.2
Nittka, M.3
Goldfarb, J.W.4
Haase, A.5
-
8
-
-
0032751897
-
Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
-
Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42:813-828.
-
(1999)
Magn Reson Med
, vol.42
, pp. 813-828
-
-
Madore, B.1
Glover, G.H.2
Pelc, N.J.3
-
9
-
-
0242385483
-
k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
-
Jeffrey Tsao, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
-
(2003)
Magn Reson Med
, vol.50
, pp. 1031-1042
-
-
Tsao, J.1
Boesiger, P.2
Pruessmann, K.P.3
-
11
-
-
19544364672
-
Optimizing spatiotem-poral sampling for k-t BLAST and k-t SENSE: Application to high- resolution real-time cardiac steady-state free precession
-
Tsao J, Kozerke S, Boesiger P, Pruessmann KP. Optimizing spatiotem-poral sampling for k-t BLAST and k-t SENSE: Application to high- resolution real-time cardiac steady-state free precession. Magn Reson Med 2005;5353:1372-1382.
-
(2005)
Magn Reson Med
, vol.5353
, pp. 1372-1382
-
-
Tsao, J.1
Kozerke, S.2
Boesiger, P.3
Pruessmann, K.P.4
-
12
-
-
7544222930
-
One the influence of training data quality in k-t BLAST reconstruction
-
Hansen MS, Kozerke S, Pruessman KP, Boesiger P, Pedersen EM, Tsao J. One the influence of training data quality in k-t BLAST reconstruction. Magn Reson Med 2004;52:1175-1183.
-
(2004)
Magn Reson Med
, vol.52
, pp. 1175-1183
-
-
Hansen, M.S.1
Kozerke, S.2
Pruessman, K.P.3
Boesiger, P.4
Pedersen, E.M.5
Tsao, J.6
-
13
-
-
34248230856
-
Improving k-t SENSE by Adaptive Regularization
-
Xu D, King KF, Liang Z-P. Improving k-t SENSE by Adaptive Regularization. Magn Reson Med 2007;57:918-930.
-
(2007)
Magn Reson Med
, vol.57
, pp. 918-930
-
-
Xu, D.1
King, K.F.2
Liang, Z.-P.3
-
14
-
-
0028695112
-
An efficient method for dynamic magnetic resonance imaging
-
Liang Z-P, Lauterbur PC. An efficient method for dynamic magnetic resonance imaging. IEEE Trans Med Imaging 1994;13: 677-686.
-
(1994)
IEEE Trans Med Imaging
, vol.13
, pp. 677-686
-
-
Liang, Z.-P.1
Lauterbur, P.C.2
-
16
-
-
31744440684
-
Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information
-
Candes E, Romberg J, Tao T. Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information. IEEE Trans Info Theory 2006;52:489-509.
-
(2006)
IEEE Trans Info Theory
, vol.52
, pp. 489-509
-
-
Candes, E.1
Romberg, J.2
Tao, T.3
-
17
-
-
34249017511
-
-
Seattle, WA, April
-
Lustig M, Santos JM, Donoho DL, Pauly JM. k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity. In Proceedings of ISMRM, Seattle, WA, April 2006.
-
(2006)
k-t SPARSE: High frame rate dynamic MRI exploiting spatio-temporal sparsity. In Proceedings of ISMRM
-
-
Lustig, M.1
Santos, J.M.2
Donoho, D.L.3
Pauly, J.M.4
-
18
-
-
36849088522
-
Sparse MRI: The application of compressed sensing for rapid MR imaging
-
Lustig M, Donoho DL, Pauly JM. Sparse MRI: The application of compressed sensing for rapid MR imaging. Magn Reson Med 2007;58:1182-1195.
-
(2007)
Magn Reson Med
, vol.58
, pp. 1182-1195
-
-
Lustig, M.1
Donoho, D.L.2
Pauly, J.M.3
-
19
-
-
34248999153
-
Improved k-t BLAST and k-t SENSE using FOCUSS
-
Jung H, Ye JC, Kim EY. Improved k-t BLAST and k-t SENSE using FOCUSS. Phys Med Biol 2007;52:3201-3226.
-
(2007)
Phys Med Biol
, vol.52
, pp. 3201-3226
-
-
Jung, H.1
Ye, J.C.2
Kim, E.Y.3
-
20
-
-
0028805010
-
Neuromagnetic source imaging with FOCUSS: A recursive weighted minimum norm algorithm. Electroen-cephalogr
-
Gorodnitsky IF, George JS, Rao BD. Neuromagnetic source imaging with FOCUSS: A recursive weighted minimum norm algorithm. Electroen-cephalogr Clin Neurophysiol 1995;95:231-251.
-
(1995)
Clin Neurophysiol
, vol.95
, pp. 231-251
-
-
Gorodnitsky, I.F.1
George, J.S.2
Rao, B.D.3
-
21
-
-
0031102203
-
Sparse signal reconstruction from limited data using FOCUSS: Re-weighted minimum norm algorithm
-
Gorodnitsky IF, Rao BD. Sparse signal reconstruction from limited data using FOCUSS: Re-weighted minimum norm algorithm. IEEE Trans Signal Processing 1997;45:600-616.
-
(1997)
IEEE Trans Signal Processing
, vol.45
, pp. 600-616
-
-
Gorodnitsky, I.F.1
Rao, B.D.2
-
22
-
-
0037313218
-
Dictionary learning algorithms for sparse representation
-
Kreutz-Delgado K, Murray JF, Rao BD, Engan K, Lee TW, Sejnowski TJ. Dictionary learning algorithms for sparse representation. Neural Comput 2003;15:349-396.
-
(2003)
Neural Comput
, vol.15
, pp. 349-396
-
-
Kreutz-Delgado, K.1
Murray, J.F.2
Rao, B.D.3
Engan, K.4
Lee, T.W.5
Sejnowski, T.J.6
-
23
-
-
0026137432
-
A video compression standard for multimedia applications
-
Gall DL. MPEG: A video compression standard for multimedia applications. Commun ACM 1991;34:46-58.
-
(1991)
Commun ACM
, vol.34
, pp. 46-58
-
-
Gall, D.M.1
-
25
-
-
21244491945
-
Analysis and compensation of eddy currents in balanced SSFP
-
Bieri O, Markl M, Scheffler K. Analysis and compensation of eddy currents in balanced SSFP. Magn Reson Med 2005;54:129-137.
-
(2005)
Magn Reson Med
, vol.54
, pp. 129-137
-
-
Bieri, O.1
Markl, M.2
Scheffler, K.3
-
26
-
-
84948655755
-
Spatio-temporal modeling and minimum redundancy adoptive acquisition in dynamic MRI
-
Aggarwal N, Zhao Q, Bresler Y. Spatio-temporal modeling and minimum redundancy adoptive acquisition in dynamic MRI. Proceedings of IEEE ISBI 2002;730-740.
-
Proceedings of IEEE
, vol.ISBI 2002
, pp. 730-740
-
-
Aggarwal, N.1
Zhao, Q.2
Bresler, Y.3
-
28
-
-
84948653511
-
Fast acquisition and sampling in MRI: Introduction to time- sequential sampling of spatio-temporal signals
-
Bresler Y. Fast acquisition and sampling in MRI: Introduction to time- sequential sampling of spatio-temporal signals. In Proceedings of IEEE ISBI, 2002, pp. 713-716.
-
(2002)
Proceedings of IEEE ISBI
, pp. 713-716
-
-
Bresler, Y.1
-
29
-
-
33750934590
-
Optimal multi-channel time-sequential acquisition in dynamic MRI with parallel coils
-
Sharif B, Bresler Y. Optimal multi-channel time-sequential acquisition in dynamic MRI with parallel coils. Proceedings of IEEE ISBI, 2006, pp. 45-48.
-
(2006)
Proceedings of IEEE ISBI
, pp. 45-48
-
-
Sharif, B.1
Bresler, Y.2
-
30
-
-
36348932742
-
Adaptive real-time caridac MRI using PARADISE: Validation by the physiologically improved NCAT phantom
-
April
-
Sharif B, Bresler Y. Adaptive real-time caridac MRI using PARADISE: Validation by the physiologically improved NCAT phantom. In Proceedings of IEEE ISBI, April 2007.
-
(2007)
Proceedings of IEEE ISBI
-
-
Sharif, B.1
Bresler, Y.2
|