메뉴 건너뛰기




Volumn 48, Issue 1, 2013, Pages 10-16

Free-breathing contrast-enhanced multiphase MRI of the liver using a combination of compressed sensing, parallel imaging, and golden-angle radial sampling

Author keywords

compressed sensing reconstruction; contrast enhanced MRI; free breathing MRI; golden angle radial acquisition; liver MRI; multicoil compressed sensing reconstruction

Indexed keywords

ADULT; ARTICLE; BREATHING; CONTRAST ENHANCEMENT; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; LIVER; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIOLOGIST;

EID: 84871607756     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e318271869c     Document Type: Article
Times cited : (218)

References (18)
  • 1
    • 28144463448 scopus 로고    scopus 로고
    • Focal hepatic lesions: Diagnostic value of enhancement pattern approach with contrast-enhanced 3D gradient-echo MR imaging
    • Elsayes KM, Narra VR, Yin Y, et al. Focal hepatic lesions: diagnostic value of enhancement pattern approach with contrast-enhanced 3D gradient-echo MR imaging. Radiographics. 2005;25: 1299-1320.
    • (2005) Radiographics. , vol.25 , pp. 1299-1320
    • Elsayes, K.M.1    Narra, V.R.2    Yin, Y.3
  • 2
    • 0030957692 scopus 로고    scopus 로고
    • Characterization of focal hepatic masses by dynamic contrast-enhanced MR imaging: Findings in 311 lesions
    • Quillin SP, Atilla S, Brown JJ, et al. Characterization of focal hepatic masses by dynamic contrast-enhanced MR imaging: findings in 311 lesions. Magn Reson Imaging. 1997;15: 275-285.
    • (1997) Magn Reson Imaging. , vol.15 , pp. 275-285
    • Quillin, S.P.1    Atilla, S.2    Brown, J.J.3
  • 3
    • 0023017677 scopus 로고
    • Respiration artifacts in MR imaging: Reduction by breath holding
    • Paling MR, Brookeman Jr. Respiration artifacts in MR imaging: reduction by breath holding. J Comput Assist Tomogr. 1986;10: 1080-1082.
    • (1986) J Comput Assist Tomogr. , vol.10 , pp. 1080-1082
    • Paling, M.R.1    Brookeman, Jr.2
  • 4
    • 0031403821 scopus 로고    scopus 로고
    • The effects of incomplete breath-holding on 3D MR image quality
    • Maki JH, Chenevert TL, Prince MR. The effects of incomplete breath-holding on 3D MR image quality. J Magn Reson Imaging. 1997;7: 1132-1139.
    • (1997) J Magn Reson Imaging. , vol.7 , pp. 1132-1139
    • Maki, J.H.1    Chenevert, T.L.2    Prince, M.R.3
  • 5
    • 55749109991 scopus 로고    scopus 로고
    • Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions
    • Lin W, Guo J, Rosen MA, et al. Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions. Magn Reson Med. 2008;60: 1135-1146.
    • (2008) Magn Reson Med. , vol.60 , pp. 1135-1146
    • Lin, W.1    Guo, J.2    Rosen, M.A.3
  • 6
    • 4744344319 scopus 로고    scopus 로고
    • Dynamic MRI with projection reconstruction and KWIC processing for simultaneous high spatial and temporal resolution
    • Song HK, Dougherty L. Dynamic MRI with projection reconstruction and KWIC processing for simultaneous high spatial and temporal resolution. Magn Reson Med. 2004;52: 815-824.
    • (2004) Magn Reson Med. , vol.52 , pp. 815-824
    • Song, H.K.1    Dougherty, L.2
  • 7
    • 80052466239 scopus 로고    scopus 로고
    • Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: A viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration
    • Chandarana H, Block TK, Rosenkrantz AB, et al. Free-breathing radial 3D fat-suppressed T1-weighted gradient echo sequence: a viable alternative for contrast-enhanced liver imaging in patients unable to suspend respiration. Invest Radiol. 2011;46: 648-653.
    • (2011) Invest Radiol. , vol.46 , pp. 648-653
    • Chandarana, H.1    Block, T.K.2    Rosenkrantz, A.B.3
  • 8
    • 80052191686 scopus 로고    scopus 로고
    • Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: Preliminary observations
    • Azevedo RM, de Campos RO, Ramalho M, et al. Free-breathing 3D T1-weighted gradient-echo sequence with radial data sampling in abdominal MRI: preliminary observations. AJR Am J Roentgenol. 2011;197: 650-657.
    • (2011) AJR Am J Roentgenol. , vol.197 , pp. 650-657
    • Azevedo, R.M.1    De Campos, R.O.2    Ramalho, M.3
  • 9
    • 36849088522 scopus 로고    scopus 로고
    • The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM, et al. The application of compressed sensing for rapid MR imaging. Magn Reson Med. 2007;58: 1182-1195.
    • (2007) Magn Reson Med. , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 10
    • 34250320137 scopus 로고    scopus 로고
    • Undersampled radial MRI with multiple coils: Iterative image reconstruction using a total variation constraint
    • Block KT, Uecker M, Frahm J, et al. Undersampled radial MRI with multiple coils: iterative image reconstruction using a total variation constraint. Magn Reson Med. 2007;57: 1086-1098.
    • (2007) Magn Reson Med. , vol.57 , pp. 1086-1098
    • Block, K.T.1    Uecker, M.2    Frahm, J.3
  • 11
    • 77955586915 scopus 로고    scopus 로고
    • Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI
    • Otazo R, Kim D, Axel L, et al. Combination of compressed sensing and parallel imaging for highly accelerated first-pass cardiac perfusion MRI. Magn Reson Med. 2010;64: 767-776.
    • (2010) Magn Reson Med. , vol.64 , pp. 767-776
    • Otazo, R.1    Kim, D.2    Axel, L.3
  • 12
    • 77955157031 scopus 로고    scopus 로고
    • Improved pediatric MR imaging with compressed sensing
    • Vasanawala SS, Alley MT, Hargreaves BA, et al. Improved pediatric MR imaging with compressed sensing. Radiology. 2010;256: 607-616.
    • (2010) Radiology. , vol.256 , pp. 607-616
    • Vasanawala, S.S.1    Alley, M.T.2    Hargreaves, B.A.3
  • 13
    • 84871619278 scopus 로고    scopus 로고
    • Free-breathing dynamic contrast-enhanced MRI of the liver with radial golden-angle sampling scheme and advanced compressed-sensing reconstruction
    • Melbourne, Australia
    • Chandarana H, Feng L, Block TK, et al. Free-breathing dynamic contrast-enhanced MRI of the liver with radial golden-angle sampling scheme and advanced compressed-sensing reconstruction. Proceedings of the 20th Annual Meeting of the ISMRM, 2012; Melbourne, Australia.
    • (2012) Proceedings of the 20th Annual Meeting of the ISMRM
    • Chandarana, H.1    Feng, L.2    Block, T.K.3
  • 14
    • 0033646318 scopus 로고    scopus 로고
    • K-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI
    • Song HK, Dougherty L. k-Space weighted image contrast (KWIC) for contrast manipulation in projection reconstruction MRI. Magn Reson Med. 2000;44: 825-832.
    • (2000) Magn Reson Med. , vol.44 , pp. 825-832
    • Song, H.K.1    Dougherty, L.2
  • 15
    • 33846246695 scopus 로고    scopus 로고
    • An optimal radial profile order based on the golden ratio for time-resolved MRI
    • Winkelmann S, Schaeffter T, Koehler T, et al. An optimal radial profile order based on the golden ratio for time-resolved MRI. IEEE Trans Med Imaging. 2007;26: 68-76.
    • (2007) IEEE Trans Med Imaging. , vol.26 , pp. 68-76
    • Winkelmann, S.1    Schaeffter, T.2    Koehler, T.3
  • 16
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibra-ting partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibra-ting partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002;47: 1202-1210.
    • (2002) Magn Reson Med. , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 17
    • 0034060592 scopus 로고    scopus 로고
    • Adaptive reconstruction of phased array MR imagery
    • Walsh DO, Gmitro AF, Marcellin MW. Adaptive reconstruction of phased array MR imagery. Magn Reson Med. 2000;43: 682-690.
    • (2000) Magn Reson Med. , vol.43 , pp. 682-690
    • Walsh, D.O.1    Gmitro, A.F.2    Marcellin, M.W.3
  • 18
    • 84871623541 scopus 로고    scopus 로고
    • Contrast-enhanced free-breathing perfusion weighted MR imaging of the whole-liver with high spatial and temporal resolution
    • Melbourne, Australia
    • Chandarana H, Feng L, Block TK, et al. Contrast-enhanced free-breathing perfusion weighted MR imaging of the whole-liver with high spatial and temporal resolution. Proceedings of the 20th Annual Meeting of the ISMRM, 2012; Melbourne, Australia.
    • (2012) Proceedings of the 20th Annual Meeting of the ISMRM
    • Chandarana, H.1    Feng, L.2    Block, T.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.