메뉴 건너뛰기




Volumn 33, Issue 9, 2015, Pages 1098-1105

Evaluation of EPI distortion correction methods for quantitative MRI of the brain at high magnetic field

Author keywords

Cerebral blood flow; Distortion correction; Field inhomogeneity; High magnetic field; Susceptibility artifact; Transgenic mouse

Indexed keywords

ARTICLE; ARTIFACT REDUCTION; BRAIN BLOOD FLOW; CONTROLLED STUDY; ECHO PLANAR IMAGING; INTERMETHOD COMPARISON; MAGNETIC FIELD; MALE; MOUSE; NEUROIMAGING; NONHUMAN; NONLINEAR SYSTEM; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SPIN LABELING; ANATOMY AND HISTOLOGY; ANIMAL; ARTIFACT; BRAIN; BRAIN MAPPING; C57BL MOUSE; FEMALE; PROCEDURES; REPRODUCIBILITY;

EID: 84943355166     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2015.06.010     Document Type: Article
Times cited : (41)

References (49)
  • 1
    • 48749112737 scopus 로고    scopus 로고
    • High-field fMRI unveils orientation columns in humans
    • Yacoub E., Harel N., Ugurbil K. High-field fMRI unveils orientation columns in humans. Proc Natl Acad Sci U S A 2008, 105(30):10607-10612.
    • (2008) Proc Natl Acad Sci U S A , vol.105 , Issue.30 , pp. 10607-10612
    • Yacoub, E.1    Harel, N.2    Ugurbil, K.3
  • 2
    • 77950118079 scopus 로고    scopus 로고
    • Cerebellar cortical layers: in vivo visualization with structural high-field-strength MR imaging
    • Marques J.P., van der Zwaag W., Granziera C., Krueger G., Gruetter R. Cerebellar cortical layers: in vivo visualization with structural high-field-strength MR imaging. Radiology 2010, 254(3):942-948.
    • (2010) Radiology , vol.254 , Issue.3 , pp. 942-948
    • Marques, J.P.1    van der Zwaag, W.2    Granziera, C.3    Krueger, G.4    Gruetter, R.5
  • 3
    • 79251567097 scopus 로고    scopus 로고
    • Human imaging at 9.4T using T(2) *-, phase-, and susceptibility-weighted contrast
    • Budde J., Shajan G., Hoffmann J., Ugurbil K., Pohmann R. Human imaging at 9.4T using T(2) *-, phase-, and susceptibility-weighted contrast. Magn Reson Med 2011, 65(2):544-550.
    • (2011) Magn Reson Med , vol.65 , Issue.2 , pp. 544-550
    • Budde, J.1    Shajan, G.2    Hoffmann, J.3    Ugurbil, K.4    Pohmann, R.5
  • 4
    • 77954811844 scopus 로고    scopus 로고
    • Direct visualization of deep brain stimulation targets in Parkinson disease with the use of 7-tesla magnetic resonance imaging
    • Cho Z.H., Min H.K., Oh S.H., Han J.Y., Park C.W., Chi J.G., et al. Direct visualization of deep brain stimulation targets in Parkinson disease with the use of 7-tesla magnetic resonance imaging. J Neurosurg 2010, 113(3):639-647.
    • (2010) J Neurosurg , vol.113 , Issue.3 , pp. 639-647
    • Cho, Z.H.1    Min, H.K.2    Oh, S.H.3    Han, J.Y.4    Park, C.W.5    Chi, J.G.6
  • 7
    • 0032868199 scopus 로고    scopus 로고
    • 3D z-shim method for reduction of susceptibility effects in BOLD fMRI
    • Glover G.H. 3D z-shim method for reduction of susceptibility effects in BOLD fMRI. Magn Reson Med 1999, 42(2):290-299.
    • (1999) Magn Reson Med , vol.42 , Issue.2 , pp. 290-299
    • Glover, G.H.1
  • 8
    • 33846817451 scopus 로고    scopus 로고
    • Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation
    • Du Y.P., Dalwani M., Wylie K., Claus E., Tregellas J.R. Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation. Magn Reson Med 2007, 57(2):396-404.
    • (2007) Magn Reson Med , vol.57 , Issue.2 , pp. 396-404
    • Du, Y.P.1    Dalwani, M.2    Wylie, K.3    Claus, E.4    Tregellas, J.R.5
  • 9
    • 0032768601 scopus 로고    scopus 로고
    • Composite image formation in z-shimmed functional MR imaging
    • Constable R.T., Spencer D.D. Composite image formation in z-shimmed functional MR imaging. Magn Reson Med 1999, 42(1):110-117.
    • (1999) Magn Reson Med , vol.42 , Issue.1 , pp. 110-117
    • Constable, R.T.1    Spencer, D.D.2
  • 10
  • 12
    • 0029034190 scopus 로고
    • Correction for geometric distortion in echo planar images from B0 field variations
    • Jezzard P., Balaban R.S. Correction for geometric distortion in echo planar images from B0 field variations. Magn Reson Med 1995, 34(1):65-73.
    • (1995) Magn Reson Med , vol.34 , Issue.1 , pp. 65-73
    • Jezzard, P.1    Balaban, R.S.2
  • 13
    • 0030912558 scopus 로고    scopus 로고
    • Reduction of geometric and intensity distortions in echo-planar imaging using a multireference scan
    • Wan X., Gullberg G.T., Parker D.L., Zeng G.L. Reduction of geometric and intensity distortions in echo-planar imaging using a multireference scan. Magn Reson Med 1997, 37(6):932-942.
    • (1997) Magn Reson Med , vol.37 , Issue.6 , pp. 932-942
    • Wan, X.1    Gullberg, G.T.2    Parker, D.L.3    Zeng, G.L.4
  • 15
    • 0034310510 scopus 로고    scopus 로고
    • Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model
    • Studholme C., Constable R.T., Duncan J.S. Accurate alignment of functional EPI data to anatomical MRI using a physics-based distortion model. IEEE Trans Med Imaging 2000, 19(11):1115-1127.
    • (2000) IEEE Trans Med Imaging , vol.19 , Issue.11 , pp. 1115-1127
    • Studholme, C.1    Constable, R.T.2    Duncan, J.S.3
  • 16
    • 0026925939 scopus 로고
    • A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities
    • Chang H., Fitzpatrick J.M. A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities. IEEE Trans Med Imaging 1992, 11(3):319-329.
    • (1992) IEEE Trans Med Imaging , vol.11 , Issue.3 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2
  • 17
    • 1842590302 scopus 로고    scopus 로고
    • Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method
    • Morgan P.S., Bowtell R.W., McIntyre D.J., Worthington B.S. Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method. J Magn Reson Imaging 2004, 19(4):499-507.
    • (2004) J Magn Reson Imaging , vol.19 , Issue.4 , pp. 499-507
    • Morgan, P.S.1    Bowtell, R.W.2    McIntyre, D.J.3    Worthington, B.S.4
  • 19
    • 0142074685 scopus 로고    scopus 로고
    • How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    • Andersson J.L., Skare S., Ashburner J. How to correct susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 2003, 20(2):870-888.
    • (2003) Neuroimage , vol.20 , Issue.2 , pp. 870-888
    • Andersson, J.L.1    Skare, S.2    Ashburner, J.3
  • 20
    • 75349084742 scopus 로고    scopus 로고
    • Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging
    • Holland D., Kuperman J.M., Dale A.M. Efficient correction of inhomogeneous static magnetic field-induced distortion in Echo Planar Imaging. Neuroimage 2010, 50(1):175-183.
    • (2010) Neuroimage , vol.50 , Issue.1 , pp. 175-183
    • Holland, D.1    Kuperman, J.M.2    Dale, A.M.3
  • 21
    • 84866326392 scopus 로고    scopus 로고
    • Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images
    • Ruthotto L., Kugel H., Olesch J., Fischer B., Modersitzki J., Burger M., et al. Diffeomorphic susceptibility artifact correction of diffusion-weighted magnetic resonance images. Phys Med Biol 2012, 57(18):5715-5731.
    • (2012) Phys Med Biol , vol.57 , Issue.18 , pp. 5715-5731
    • Ruthotto, L.1    Kugel, H.2    Olesch, J.3    Fischer, B.4    Modersitzki, J.5    Burger, M.6
  • 23
    • 78349239713 scopus 로고    scopus 로고
    • Distortion correction for diffusion-weighted MRI tractography and fMRI in the temporal lobes
    • Embleton K.V., Haroon H.A., Morris D.M., Ralph M.A., Parker G.J. Distortion correction for diffusion-weighted MRI tractography and fMRI in the temporal lobes. Hum Brain Mapp 2010, 31(10):1570-1587.
    • (2010) Hum Brain Mapp , vol.31 , Issue.10 , pp. 1570-1587
    • Embleton, K.V.1    Haroon, H.A.2    Morris, D.M.3    Ralph, M.A.4    Parker, G.J.5
  • 24
    • 84894275049 scopus 로고    scopus 로고
    • Correction of B0-distortions in echo-planar-imaging-based perfusion-weighted MRI
    • Vardal J., Salo R.A., Larsson C., Dale A.M., Holland D., Groote I.R., et al. Correction of B0-distortions in echo-planar-imaging-based perfusion-weighted MRI. J Magn Reson Imaging 2014, 39(3):722-728.
    • (2014) J Magn Reson Imaging , vol.39 , Issue.3 , pp. 722-728
    • Vardal, J.1    Salo, R.A.2    Larsson, C.3    Dale, A.M.4    Holland, D.5    Groote, I.R.6
  • 25
    • 84894504585 scopus 로고    scopus 로고
    • High-resolution mouse kidney perfusion imaging by pseudo-continuous arterial spin labeling at 11.75T
    • Duhamel G., Prevost V., Girard O.M., Callot V., Cozzone P.J. High-resolution mouse kidney perfusion imaging by pseudo-continuous arterial spin labeling at 11.75T. Magn Reson Med 2014, 71(3):1186-1196.
    • (2014) Magn Reson Med , vol.71 , Issue.3 , pp. 1186-1196
    • Duhamel, G.1    Prevost, V.2    Girard, O.M.3    Callot, V.4    Cozzone, P.J.5
  • 26
    • 35948969225 scopus 로고    scopus 로고
    • A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling
    • Wu W.C., Fernandez-Seara M., Detre J.A., Wehrli F.W., Wang J. A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling. Magn Reson Med 2007, 58(5):1020-1027.
    • (2007) Magn Reson Med , vol.58 , Issue.5 , pp. 1020-1027
    • Wu, W.C.1    Fernandez-Seara, M.2    Detre, J.A.3    Wehrli, F.W.4    Wang, J.5
  • 29
    • 84855176732 scopus 로고    scopus 로고
    • Robust automatic rodent brain extraction using 3-D pulse-coupled neural networks (PCNN)
    • Chou N., Wu J., Bai Bingren J., Qiu A., Chuang K.H. Robust automatic rodent brain extraction using 3-D pulse-coupled neural networks (PCNN). IEEE Trans Image Process 2011, 20(9):2554-2564.
    • (2011) IEEE Trans Image Process , vol.20 , Issue.9 , pp. 2554-2564
    • Chou, N.1    Wu, J.2    Bai Bingren, J.3    Qiu, A.4    Chuang, K.H.5
  • 30
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • Buxton R.B., Frank L.R., Wong E.C., Siewert B., Warach S., Edelman R.R. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med 1998, 40(3):383-396.
    • (1998) Magn Reson Med , vol.40 , Issue.3 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3    Siewert, B.4    Warach, S.5    Edelman, R.R.6
  • 33
    • 35448989836 scopus 로고    scopus 로고
    • Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients
    • Yeo D.T., Chenevert T.L., Fessler J.A., Kim B. Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients. Magn Reson Imaging 2007, 25(9):1263-1271.
    • (2007) Magn Reson Imaging , vol.25 , Issue.9 , pp. 1263-1271
    • Yeo, D.T.1    Chenevert, T.L.2    Fessler, J.A.3    Kim, B.4
  • 34
    • 0037370552 scopus 로고    scopus 로고
    • Quantitative measurements of proton spin-lattice (T1) and spin-spin (T2) relaxation times in the mouse brain at 7.0T
    • Guilfoyle D.N., Dyakin V.V., O'Shea J., Pell G.S., Helpern J.A. Quantitative measurements of proton spin-lattice (T1) and spin-spin (T2) relaxation times in the mouse brain at 7.0T. Magn Reson Med 2003, 49(3):576-580.
    • (2003) Magn Reson Med , vol.49 , Issue.3 , pp. 576-580
    • Guilfoyle, D.N.1    Dyakin, V.V.2    O'Shea, J.3    Pell, G.S.4    Helpern, J.A.5
  • 35
    • 53849090309 scopus 로고    scopus 로고
    • Experimental comparison of four FAIR arterial spin labeling techniques for quantification of mouse cerebral blood flow at 4.7T
    • Kober F., Duhamel G., Cozzone P.J. Experimental comparison of four FAIR arterial spin labeling techniques for quantification of mouse cerebral blood flow at 4.7T. NMR Biomed 2008, 21(8):781-792.
    • (2008) NMR Biomed , vol.21 , Issue.8 , pp. 781-792
    • Kober, F.1    Duhamel, G.2    Cozzone, P.J.3
  • 36
    • 0033366955 scopus 로고    scopus 로고
    • Diffusion- and perfusion-weighted MR imaging of transient focal cerebral ischaemia in mice
    • van Dorsten F.A., Hata R., Maeda K., Franke C., Eis M., Hossmann K.A., et al. Diffusion- and perfusion-weighted MR imaging of transient focal cerebral ischaemia in mice. NMR Biomed 1999, 12(8):525-534.
    • (1999) NMR Biomed , vol.12 , Issue.8 , pp. 525-534
    • van Dorsten, F.A.1    Hata, R.2    Maeda, K.3    Franke, C.4    Eis, M.5    Hossmann, K.A.6
  • 37
    • 26844535237 scopus 로고    scopus 로고
    • Murine orthostatic response during prolonged vertical studies: effect on cerebral blood flow measured by arterial spin-labeled MRI
    • Foley L.M., Hitchens T.K., Kochanek P.M., Melick J.A., Jackson E.K., Ho C. Murine orthostatic response during prolonged vertical studies: effect on cerebral blood flow measured by arterial spin-labeled MRI. Magn Reson Med 2005, 54(4):798-806.
    • (2005) Magn Reson Med , vol.54 , Issue.4 , pp. 798-806
    • Foley, L.M.1    Hitchens, T.K.2    Kochanek, P.M.3    Melick, J.A.4    Jackson, E.K.5    Ho, C.6
  • 38
    • 51449115065 scopus 로고    scopus 로고
    • Cerebral blood flow MRI in mice using the cardiac-spin-labeling technique
    • Muir E.R., Shen Q., Duong T.Q. Cerebral blood flow MRI in mice using the cardiac-spin-labeling technique. Magn Reson Med 2008, 60(3):744-748.
    • (2008) Magn Reson Med , vol.60 , Issue.3 , pp. 744-748
    • Muir, E.R.1    Shen, Q.2    Duong, T.Q.3
  • 39
    • 0032883422 scopus 로고    scopus 로고
    • Sources of distortion in functional MRI data
    • Jezzard P., Clare S. Sources of distortion in functional MRI data. Hum Brain Mapp 1999, 8(2-3):80-85.
    • (1999) Hum Brain Mapp , vol.8 , Issue.2-3 , pp. 80-85
    • Jezzard, P.1    Clare, S.2
  • 40
    • 33845368376 scopus 로고    scopus 로고
    • Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field
    • El-Sharkawy A.M., Schar M., Bottomley P.A., Atalar E. Monitoring and correcting spatio-temporal variations of the MR scanner's static magnetic field. MAGMA 2006, 19(5):223-236.
    • (2006) MAGMA , vol.19 , Issue.5 , pp. 223-236
    • El-Sharkawy, A.M.1    Schar, M.2    Bottomley, P.A.3    Atalar, E.4
  • 41
    • 0036263892 scopus 로고    scopus 로고
    • Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: compensation of motion artifacts and magnetic field instabilities
    • Thiel T., Czisch M., Elbel G.K., Hennig J. Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: compensation of motion artifacts and magnetic field instabilities. Magn Reson Med 2002, 47(6):1077-1082.
    • (2002) Magn Reson Med , vol.47 , Issue.6 , pp. 1077-1082
    • Thiel, T.1    Czisch, M.2    Elbel, G.K.3    Hennig, J.4
  • 42
    • 33646441856 scopus 로고    scopus 로고
    • Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI
    • Lee J., Santos J.M., Conolly S.M., Miller K.L., Hargreaves B.A., Pauly J.M. Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI. Magn Reson Med 2006, 55(5):1197-1201.
    • (2006) Magn Reson Med , vol.55 , Issue.5 , pp. 1197-1201
    • Lee, J.1    Santos, J.M.2    Conolly, S.M.3    Miller, K.L.4    Hargreaves, B.A.5    Pauly, J.M.6
  • 43
    • 84891631945 scopus 로고    scopus 로고
    • Detection of functional connectivity in the resting mouse brain
    • Nasrallah F.A., Tay H.C., Chuang K.H. Detection of functional connectivity in the resting mouse brain. Neuroimage 2014, 86:417-424.
    • (2014) Neuroimage , vol.86 , pp. 417-424
    • Nasrallah, F.A.1    Tay, H.C.2    Chuang, K.H.3
  • 44
    • 0030726765 scopus 로고    scopus 로고
    • Measurement of the point spread function in MRI using constant time imaging
    • Robson M.D., Gore J.C., Constable R.T. Measurement of the point spread function in MRI using constant time imaging. Magn Reson Med 1997, 38(5):733-740.
    • (1997) Magn Reson Med , vol.38 , Issue.5 , pp. 733-740
    • Robson, M.D.1    Gore, J.C.2    Constable, R.T.3
  • 45
    • 0036296026 scopus 로고    scopus 로고
    • Image distortion correction in EPI: comparison of field mapping with point spread function mapping
    • Zeng H., Constable R.T. Image distortion correction in EPI: comparison of field mapping with point spread function mapping. Magn Reson Med 2002, 48(1):137-146.
    • (2002) Magn Reson Med , vol.48 , Issue.1 , pp. 137-146
    • Zeng, H.1    Constable, R.T.2
  • 46
    • 7544248836 scopus 로고    scopus 로고
    • Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction
    • Zaitsev M., Hennig J., Speck O. Point spread function mapping with parallel imaging techniques and high acceleration factors: fast, robust, and flexible method for echo-planar imaging distortion correction. Magn Reson Med 2004, 52(5):1156-1166.
    • (2004) Magn Reson Med , vol.52 , Issue.5 , pp. 1156-1166
    • Zaitsev, M.1    Hennig, J.2    Speck, O.3
  • 47
    • 41849129576 scopus 로고    scopus 로고
    • High resolution single-shot EPI at 7T
    • Speck O., Stadler J., Zaitsev M. High resolution single-shot EPI at 7T. MAGMA 2008, 21(1-2):73-86.
    • (2008) MAGMA , vol.21 , Issue.1-2 , pp. 73-86
    • Speck, O.1    Stadler, J.2    Zaitsev, M.3
  • 48
    • 84923666886 scopus 로고    scopus 로고
    • Distortion correction in EPI using an extended PSF method with a reversed phase gradient approach
    • In M.H., Posnansky O., Beall E.B., Lowe M.J., Speck O. Distortion correction in EPI using an extended PSF method with a reversed phase gradient approach. PLoS One 2015, 10(2):e0116320.
    • (2015) PLoS One , vol.10 , Issue.2 , pp. e0116320
    • In, M.H.1    Posnansky, O.2    Beall, E.B.3    Lowe, M.J.4    Speck, O.5
  • 49
    • 84899105435 scopus 로고    scopus 로고
    • A hybrid strategy for correcting geometric distortion in echo-planar images
    • Gelman N., Silavi A., Anazodo U. A hybrid strategy for correcting geometric distortion in echo-planar images. Magn Reson Imaging 2014, 32(5):590-593.
    • (2014) Magn Reson Imaging , vol.32 , Issue.5 , pp. 590-593
    • Gelman, N.1    Silavi, A.2    Anazodo, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.