메뉴 건너뛰기




Volumn 32, Issue 5, 2014, Pages 590-593

A hybrid strategy for correcting geometric distortion in echo-planar images

Author keywords

Diffusion weighted imaging; Echo planar imaging; Field mapping; Geometric distortion correction; Reverse phase encode gradient acquisition

Indexed keywords

ARTICLE; CONTROLLED STUDY; ECHO PLANAR IMAGING; GEOMETRY; IMAGE DISPLAY; IMAGE PROCESSING; IMAGE QUALITY; MATHEMATICAL ANALYSIS; MATHEMATICAL COMPUTING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; QUALITY CONTROL; QUALITY CONTROL PROCEDURES; RADIOLOGICAL PARAMETERS; RADIOLOGICAL PROCEDURES; SIGNAL PROCESSING; ALGORITHM; ANATOMY AND HISTOLOGY; ARTIFACT; BRAIN; COMPUTER ASSISTED DIAGNOSIS; HUMAN; IMAGE ENHANCEMENT; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 84899105435     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2014.02.011     Document Type: Article
Times cited : (6)

References (9)
  • 2
    • 78650472921 scopus 로고    scopus 로고
    • Twenty-five pitfalls in the analysis of diffusion MRI data
    • Jones D.K., Cercignani M. Twenty-five pitfalls in the analysis of diffusion MRI data. NMR Biomed 2010, 23:803-820.
    • (2010) NMR Biomed , vol.23 , pp. 803-820
    • Jones, D.K.1    Cercignani, M.2
  • 3
    • 0036296026 scopus 로고    scopus 로고
    • Image distortion correction in EPI: comparison of field mapping with point spread function mapping
    • Zheng H., Constable R.T. Image distortion correction in EPI: comparison of field mapping with point spread function mapping. Magn Reson Med 2002, 48:137-146.
    • (2002) Magn Reson Med , vol.48 , pp. 137-146
    • Zheng, H.1    Constable, R.T.2
  • 4
    • 0026925939 scopus 로고
    • A technique for accurate magnetic r esonance imaging in the presence of field inhomogeneities
    • Chang H., Fitzpatrick J.M. A technique for accurate magnetic r esonance imaging in the presence of field inhomogeneities. IEEE Trans Med Imaging 1992, 11(3):319-329.
    • (1992) IEEE Trans Med Imaging , vol.11 , Issue.3 , pp. 319-329
    • Chang, H.1    Fitzpatrick, J.M.2
  • 5
    • 1842590302 scopus 로고    scopus 로고
    • Correction of spatial distortions in EPI due to in homogeneous static fields using the reverse gradient method
    • Morgan P.S., Bowtell R.W., McIntyre D.J.O., Worthington B.S. Correction of spatial distortions in EPI due to in homogeneous static fields using the reverse gradient method. J Magn Reson Imaging 2004, 19:499-507.
    • (2004) J Magn Reson Imaging , vol.19 , pp. 499-507
    • Morgan, P.S.1    Bowtell, R.W.2    McIntyre, D.J.O.3    Worthington, B.S.4
  • 6
    • 75349084742 scopus 로고    scopus 로고
    • Efficient correction of inhomogeneous static magnetic field-induced distortion in echo planar imaging
    • Holland D., Kuperman J.M., Dale A.M. Efficient correction of inhomogeneous static magnetic field-induced distortion in echo planar imaging. Neuroimage 2010, 50:175-183.
    • (2010) Neuroimage , vol.50 , pp. 175-183
    • Holland, D.1    Kuperman, J.M.2    Dale, A.M.3
  • 7
    • 0142074685 scopus 로고    scopus 로고
    • How to correct of susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging
    • Andersson J.L., Skare S., Ashburner J. How to correct of susceptibility distortions in spin-echo echo-planar images: application to diffusion tensor imaging. Neuroimage 2003, 20:870-888.
    • (2003) Neuroimage , vol.20 , pp. 870-888
    • Andersson, J.L.1    Skare, S.2    Ashburner, J.3
  • 8
    • 74949123772 scopus 로고    scopus 로고
    • Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen
    • Dale B.M., Braithwaite A.C., Boll D.T., Merkle E.M. Field strength and diffusion encoding technique affect the apparent diffusion coefficient measurements in diffusion-weighted imaging of the abdomen. Invest Radiol 2010, 45(2):104-108.
    • (2010) Invest Radiol , vol.45 , Issue.2 , pp. 104-108
    • Dale, B.M.1    Braithwaite, A.C.2    Boll, D.T.3    Merkle, E.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.