메뉴 건너뛰기




Volumn , Issue , 2013, Pages 3921-3924

A novel online recalibration strategy for continuous glucose measurement sensors employing LMI techniques

Author keywords

[No Author keywords available]

Indexed keywords

AUTOMATIC DETECTION; CALIBRATION MEASUREMENTS; CONSTRUCTIVE ALGORITHMS; CONTINUOUS GLUCOSE MONITORING; GLUCOSE MEASUREMENTS; MEASUREMENT UNCERTAINTY; ON-LINE CALIBRATION; STATE OF THE ART;

EID: 84886547493     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2013.6610402     Document Type: Conference Paper
Times cited : (8)

References (14)
  • 1
    • 78650760751 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • B. Kovatchev, L. Heinemann, S. Anderson, and W. Clarke, "Comparison of the numerical and clinical accuracy of four continuous glucose monitors, " Diabetes Care, vol. 31, no. 6, pp. 1160-1164, 2008.
    • (2008) Diabetes Care , vol.31 , Issue.6 , pp. 1160-1164
    • Kovatchev, B.1    Heinemann, L.2    Anderson, S.3    Clarke, W.4
  • 2
    • 50049129722 scopus 로고    scopus 로고
    • Clinical application of emerging sensor technologies in diabetes management: Consensus guidelines for continuous glucose monitoring (cgm)
    • I. B. Hirsch, D. Armstrong, R. M. Bergenstal, B. Buckingham, B. Childs, W. L. Clarke, and A. Peters, "Clinical application of emerging sensor technologies in diabetes management: Consensus guidelines for continuous glucose monitoring (cgm), " Diabetes Technology & Therapeutics, vol. 10, no. 4, pp. 232-244, 2008.
    • (2008) Diabetes Technology & Therapeutics , vol.10 , Issue.4 , pp. 232-244
    • Hirsch, I.B.1    Armstrong, D.2    Bergenstal, R.M.3    Buckingham, B.4    Childs, B.5    Clarke, W.L.6    Peters, A.7
  • 4
    • 0042018757 scopus 로고    scopus 로고
    • Continuous glucose monitoring with glucose sensors: Calibration and assessment criteria
    • V. Lodwig and L. Heinemann, "Continuous glucose monitoring with glucose sensors: calibration and assessment criteria." Diabetes Technol Ther, vol. 5, pp. 572-86, 2003.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 572-586
    • Lodwig, V.1    Heinemann, L.2
  • 8
    • 0242300559 scopus 로고    scopus 로고
    • Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    • M. S. Boyne, D. M. Silver, J. Kaplan, and C. D. Saudek, "Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor, " Diabetes, vol. 52, no. 11, pp. 2790-2794, 2003.
    • (2003) Diabetes , vol.52 , Issue.11 , pp. 2790-2794
    • Boyne, M.S.1    Silver, D.M.2    Kaplan, J.3    Saudek, C.D.4
  • 9
    • 14844348734 scopus 로고    scopus 로고
    • The extended kalman filter for continuous glucose monitoring
    • E. J. Knobbe and B. Buckingham, "The extended kalman filter for continuous glucose monitoring, " Diabetes Technology & Therapeutics, vol. 7, no. 1, pp. 15-27, 2005.
    • (2005) Diabetes Technology & Therapeutics , vol.7 , Issue.1 , pp. 15-27
    • Knobbe, E.J.1    Buckingham, B.2
  • 10
    • 0027474090 scopus 로고
    • On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis
    • E. F. Pfeiffer, C. Meyerhoff, F. Bischof, F. S. Keck, and W. Kerner, "On line continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis, " Horm Metab Res, vol. 25, pp. 121-124, 1993.
    • (1993) Horm Metab Res , vol.25 , pp. 121-124
    • Pfeiffer, E.F.1    Meyerhoff, C.2    Bischof, F.3    Keck, F.S.4    Kerner, W.5
  • 11
    • 0043025558 scopus 로고    scopus 로고
    • Physiological differences between interstitial glucose and blood glucose measured in human subjects
    • August
    • E. Kulcu, J. A. Tamada, G. Reach, R. O. Potts, and M. J. Lesho, "Physiological differences between interstitial glucose and blood glucose measured in human subjects, " Diabetes Care, vol. 26, no. 8, pp. 2405-2419, August 2003.
    • (2003) Diabetes Care , vol.26 , Issue.8 , pp. 2405-2419
    • Kulcu, E.1    Tamada, J.A.2    Reach, G.3    Potts, R.O.4    Lesho, M.J.5
  • 12
    • 0032836714 scopus 로고    scopus 로고
    • Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
    • Sep
    • K. Rebrin, G. Steil, W. Van Antwerp, and J. Mastrototaro, "Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring, " Am J of Physiology-Endocrinology and Metabolism, vol. 277, no. 3, pp. E561-E571, Sep 1999.
    • (1999) Am J of Physiology-Endocrinology and Metabolism , vol.277 , Issue.3
    • Rebrin, K.1    Steil, G.2    Van Antwerp, W.3    Mastrototaro, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.