메뉴 건너뛰기




Volumn 5, Issue 3, 2011, Pages 583-595

Metabolic biofouling of glucose sensors in vivo: Role of tissue microhemorrhages

Author keywords

Artificial hemorrhages; Blood clots; Continuous glucose monitoring; Implantable glucose sensor; Metabolic biofouling; Mouse; Sensor function in vivo; Temporary signal reduction; Tissue hemorrhages

Indexed keywords

GLUCOSE; SODIUM CHLORIDE;

EID: 84872781187     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681100500313     Document Type: Article
Times cited : (55)

References (15)
  • 1
    • 4644297442 scopus 로고    scopus 로고
    • Enhancement of implantable glucose sensor function in vivo using gene transfer-induced neovascularization
    • DOI 10.1016/j.biomaterials.2004.04.017, PII S014296120400362X
    • Klueh U, Dorsky DI, Kreutzer DL. Enhancement of implantable glucose sensor function in vivo using gene transfer-induced neovascularization. Biomaterials. 2005;26(10):1155-1163. [PubMed] (Pubitemid 39286825)
    • (2005) Biomaterials , vol.26 , Issue.10 , pp. 1155-1163
    • Klueh, U.1    Dorsky, D.I.2    Kreutzer, D.L.3
  • 2
    • 0033375080 scopus 로고    scopus 로고
    • Assessment of chronically implanted subcutaneous glucose sensors in dogs: The effect of surrounding fluid masses
    • Ward WK, Troupe JE. Assessment of chronically implanted subcutaneous glucose sensors in dogs: the effect of surrounding fluid masses. ASAIO J. 1999;45(6):555-561. [PubMed] (Pubitemid 30017346)
    • (1999) ASAIO Journal , vol.45 , Issue.6 , pp. 555-561
    • Ward, W.K.1    Troupe, J.E.2
  • 3
    • 84887251507 scopus 로고    scopus 로고
    • Blood-induced interference of glucose sensor function in vitro: Implications for in vivo sensor function
    • [PMC free article] [PubMed]
    • Klueh U, Liu Z, Ouyang T, Cho B, Feldman B, Henning TP, Kreutzer D. Blood-induced interference of glucose sensor function in vitro: implications for in vivo sensor function. J Diabetes Sci Technol. 2007;1(6):842-849. [PMC free article] [PubMed]
    • (2007) J Diabetes Sci Technol , vol.1 , Issue.6 , pp. 842-849
    • Klueh, U.1    Liu, Z.2    Ouyang, T.3    Cho, B.4    Feldman, B.5    Henning, T.P.6    Kreutzer, D.7
  • 4
    • 77950026778 scopus 로고    scopus 로고
    • Critical role of tissue mast cells in controlling long-term glucose sensor function in vivo
    • [PMC free article] [PubMed]
    • Klueh U, Kaur M, Qiao Y, Kreutzer DL. Critical role of tissue mast cells in controlling long-term glucose sensor function in vivo. Biomaterials. 2010;31(16):4540-4551. [PMC free article] [PubMed]
    • (2010) Biomaterials , vol.31 , Issue.16 , pp. 4540-4551
    • Klueh, U.1    Kaur, M.2    Qiao, Y.3    Kreutzer, D.L.4
  • 6
    • 79952198318 scopus 로고    scopus 로고
    • Importance of interleukin-1 and interleukin-1 receptor antagonist in short-term glucose sensor function in vivo
    • [PMC free article] [PubMed]
    • Klueh U, Liu Z, Feldman B, Kreutzer D. Importance of interleukin-1 and interleukin-1 receptor antagonist in short-term glucose sensor function in vivo. J Diabetes Sci Technol. 2010;4(5):1073-1086. [PMC free article] [PubMed]
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.5 , pp. 1073-1086
    • Klueh, U.1    Liu, Z.2    Feldman, B.3    Kreutzer, D.4
  • 7
    • 0031727960 scopus 로고    scopus 로고
    • Saphenous vein puncture for blood sampling of the mouse, rat, hamster, gerbil, guineapig, ferret and mink
    • Hem A, Smith AJ, Solberg P. Saphenous vein puncture for blood sampling of the mouse, rat, hamster, gerbil, guinea pig, ferret and mink. Lab Anim. 1998;32(4):364-368. [PubMed] (Pubitemid 28482470)
    • (1998) Laboratory Animals , vol.32 , Issue.4 , pp. 364-368
    • Hem, A.1    Smith, A.J.2    Solberg, P.3
  • 8
    • 10844254726 scopus 로고    scopus 로고
    • Introductory experience with the continuous glucose monitoring system (CGMS Medtronic Minimed) in detecting hyperglycemia by comparing the self-monitoring of blood glucose (SMBG) in non-pregnant women and in pregnant women with impaired glucose tolerance and gestational diabetes
    • DOI 10.1055/s-2004-830399
    • Bühling KJ, Kurzidim B, Wolf C, Wohlfarth K, Mahmoudi M, Wäscher C, Siebert G, Dudenhausen JW. Introductory experience with the continuous glucose monitoring system (CGMS; Medtronic Minimed) in detecting hyperglycemia by comparing the self-monitoring of blood glucose (SMBG) in non-pregnant women and in pregnant women with impaired glucose tolerance and gestational diabetes. Exp Clin Endocrinol Diabetes. 2004;112(10):556-560. [PubMed] (Pubitemid 39664693)
    • (2004) Experimental and Clinical Endocrinology and Diabetes , vol.112 , Issue.10 , pp. 556-560
    • Buhling, K.J.1    Kurzidim, B.2    Wolf, C.3    Wohlfarth, K.4    Mahmoudi, M.5    Wascher, C.6    Siebert, G.7    Dudenhausen, J.W.8
  • 9
    • 17144458994 scopus 로고    scopus 로고
    • Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions
    • Djakouré-Platonoff C, Radermercker R, Reach G, Slama G, Selam JI. Accuracy of the continuous glucose monitoring system in inpatient and outpatient conditions. Diabetes Metab. 2003;29(2 Pt 1):159-162. [PubMed] (Pubitemid 36576095)
    • (2003) Diabetes and Metabolism , vol.29 , Issue.2 I , pp. 159-162
    • Djakoure-Platonoff, C.1    Radermercker, R.2    Reach, G.3    Slama, G.4    Selam, J.L.5
  • 10
    • 0242363717 scopus 로고    scopus 로고
    • A Continuous Glucose Sensor Based on Wired Enzyme Technology - Results from a 3-Day Trial in Patients with Type 1 Diabetes
    • DOI 10.1089/152091503322526978
    • Feldman B, Brazg R, Schwartz S, Weinstein R. A continuous glucose sensor based on wired enzyme technology - results from a 3-day trial in patients with type 1 diabetes. Diabetes Technol Ther. 2003;5(5):769-779. [PubMed] (Pubitemid 37339539)
    • (2003) Diabetes Technology and Therapeutics , vol.5 , Issue.5 , pp. 769-779
    • Feldman, B.1    Brazg, R.2    Schwartz, S.3    Weinstein, R.4
  • 13
    • 14844351847 scopus 로고    scopus 로고
    • Accuracy of the modified continuous glucose monitoring system (CGMS) sensor in an outpatient setting: Results from a diabetes research in children network (DirecNet) study
    • DOI 10.1089/dia.2005.7.109
    • Tansey MJ, Beck RW, Buckingham BA, Mauras N, Fiallo-Scharer R, Xing D, Killman C, Tamborlane WV, Ruedy KJ. Diabetes Research in Children Network (DirecNet) Study Group. Accuracy of the modified Continuous Glucose Monitoring System (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study. Diabetes Technol Ther. 2005;7(1):109-114. [PMC free article] [PubMed] (Pubitemid 40354580)
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.1 , pp. 109-114
    • Tansey, M.J.1
  • 15
    • 30944436829 scopus 로고    scopus 로고
    • Protein interactions with subcutaneously implanted biosensors
    • DOI 10.1016/j.biomaterials.2005.11.033, PII S0142961205010598
    • Gifford R, Kehoe JJ, Barnes SL, Kornilayev BA, Alterman MA, Wilson GS. Protein interactions with subcutaneously implanted biosensors. Biomaterials. 2006;27(12):2587-2598. [PubMed] (Pubitemid 43115237)
    • (2006) Biomaterials , vol.27 , Issue.12 , pp. 2587-2598
    • Gifford, R.1    Kehoe, J.J.2    Barnes, S.L.3    Kornilayev, B.A.4    Alterman, M.A.5    Wilson, G.S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.