메뉴 건너뛰기




Volumn 93, Issue , 2015, Pages 320-327

Is the cellular uptake of respiratory aerosols delivered from different devices equivalent?

Author keywords

Andersen cascade impactor; Calu 3; DPI; Inhaled formulation; Nebuliser; pMDI; Salbutamol

Indexed keywords

SALBUTAMOL; AEROSOL; BRONCHODILATING AGENT; POWDER;

EID: 84930193182     PISSN: 09396411     EISSN: 18733441     Source Type: Journal    
DOI: 10.1016/j.ejpb.2015.04.012     Document Type: Article
Times cited : (17)

References (44)
  • 1
    • 0242584998 scopus 로고    scopus 로고
    • Large porous particle impingement on lung epithelial cell monolayers - Toward improved particle characterization in the lung
    • J. Fiegel, C. Ehrhardt, U.F. Schaefer, C.-M. Lehr, and J. Hanes Large porous particle impingement on lung epithelial cell monolayers - toward improved particle characterization in the lung Pharm. Res. 20 2003 788 796
    • (2003) Pharm. Res. , vol.20 , pp. 788-796
    • Fiegel, J.1    Ehrhardt, C.2    Schaefer, U.F.3    Lehr, C.-M.4    Hanes, J.5
  • 2
    • 33745630072 scopus 로고    scopus 로고
    • Culture of Calu-3 cells at the air interface provides a representative model of the airway epithelial barrier
    • C.I. Grainger, L.L. Greenwell, D.J. Lockley, G.P. Martin, and B. Forbes Culture of Calu-3 cells at the air interface provides a representative model of the airway epithelial barrier Pharm. Res. 23 2006 1482 1490
    • (2006) Pharm. Res. , vol.23 , pp. 1482-1490
    • Grainger, C.I.1    Greenwell, L.L.2    Lockley, D.J.3    Martin, G.P.4    Forbes, B.5
  • 3
    • 84910036519 scopus 로고    scopus 로고
    • Across the pulmonary epithelial barrier: Integration of physicochemical properties and human cell models to study pulmonary drug formulations
    • M. Haghi, H.X. Ong, D. Traini, and P. Young Across the pulmonary epithelial barrier: integration of physicochemical properties and human cell models to study pulmonary drug formulations Pharmacol. Therapeut. 2014
    • (2014) Pharmacol. Therapeut.
    • Haghi, M.1    Ong, H.X.2    Traini, D.3    Young, P.4
  • 4
    • 84882395942 scopus 로고    scopus 로고
    • Pharmaceutical applications of the Calu-3 lung epithelia cell line
    • H.X. Ong, D. Traini, and P.M. Young Pharmaceutical applications of the Calu-3 lung epithelia cell line Expert Opin. Drug Deliv. 10 2013 1287 1302
    • (2013) Expert Opin. Drug Deliv. , vol.10 , pp. 1287-1302
    • Ong, H.X.1    Traini, D.2    Young, P.M.3
  • 5
    • 84862001733 scopus 로고    scopus 로고
    • Deposition, diffusion and transport mechanism of dry powder microparticulate salbutamol, at the respiratory epithelia
    • M. Haghi, D. Traini, M. Bebawy, and P.M. Young Deposition, diffusion and transport mechanism of dry powder microparticulate salbutamol, at the respiratory epithelia Mol. Pharm. 9 2012 1717 1726
    • (2012) Mol. Pharm. , vol.9 , pp. 1717-1726
    • Haghi, M.1    Traini, D.2    Bebawy, M.3    Young, P.M.4
  • 6
    • 80054750314 scopus 로고    scopus 로고
    • Epithelial profiling of antibiotic controlled release respiratory formulations
    • H.X. Ong, D. Traini, M. Bebawy, and P.M. Young Epithelial profiling of antibiotic controlled release respiratory formulations Pharm. Res. 28 2011 2327 2338
    • (2011) Pharm. Res. , vol.28 , pp. 2327-2338
    • Ong, H.X.1    Traini, D.2    Bebawy, M.3    Young, P.M.4
  • 7
    • 84881365375 scopus 로고    scopus 로고
    • The effects of mannitol on the transport of ciprofloxacin across respiratory epithelia
    • H.X. Ong, D. Traini, R. Salama, S.D. Anderson, E. Daviskas, and P.M. Young The effects of mannitol on the transport of ciprofloxacin across respiratory epithelia Mol. Pharm. 10 2013 2915 2924
    • (2013) Mol. Pharm. , vol.10 , pp. 2915-2924
    • Ong, H.X.1    Traini, D.2    Salama, R.3    Anderson, S.D.4    Daviskas, E.5    Young, P.M.6
  • 8
    • 84872118822 scopus 로고    scopus 로고
    • Liposomal nanoparticles control the uptake of ciprofloxacin across respiratory epithelia
    • H.X. Ong, D. Traini, D. Cipolla, I. Gonda, M. Bebawy, H. Agus, and P.M. Young Liposomal nanoparticles control the uptake of ciprofloxacin across respiratory epithelia Pharm. Res. 29 2012 3335 3346
    • (2012) Pharm. Res. , vol.29 , pp. 3335-3346
    • Ong, H.X.1    Traini, D.2    Cipolla, D.3    Gonda, I.4    Bebawy, M.5    Agus, H.6    Young, P.M.7
  • 9
    • 84896691331 scopus 로고    scopus 로고
    • Towards the bioequivalence of pressurised metered dose inhalers 2. Aerodynamically equivalent particles (with and without glycerol) exhibit different biopharmaceutical profiles in vitro
    • M. Haghi, M. Bebawy, P. Colombo, B. Forbes, D. Lewis, R. Salama, D. Traini, and P. Young Towards the bioequivalence of pressurised metered dose inhalers 2. Aerodynamically equivalent particles (with and without glycerol) exhibit different biopharmaceutical profiles in vitro Eur. J. Pharm. Biopharm. 86 2014 38 45
    • (2014) Eur. J. Pharm. Biopharm. , vol.86 , pp. 38-45
    • Haghi, M.1    Bebawy, M.2    Colombo, P.3    Forbes, B.4    Lewis, D.5    Salama, R.6    Traini, D.7    Young, P.8
  • 10
    • 84904244848 scopus 로고    scopus 로고
    • In vitro cell integrated impactor deposition methodology for the study of aerodynamically relevant size fractions from commercial pressurised metered dose inhalers
    • M. Haghi, D. Traini, and P. Young In vitro cell integrated impactor deposition methodology for the study of aerodynamically relevant size fractions from commercial pressurised metered dose inhalers Pharm. Res. 2014 1 9
    • (2014) Pharm. Res. , pp. 1-9
    • Haghi, M.1    Traini, D.2    Young, P.3
  • 11
    • 84923607941 scopus 로고    scopus 로고
    • Office OdS. Appendix XII C. (accessed 02.02.15).
    • Office OdS. British Pharmacopoeia, Appendix XII C. 2012; < http://www.pharmacopoeia.co.uk > (accessed 02.02.15).
    • (2012) British Pharmacopoeia
  • 12
    • 79953031097 scopus 로고    scopus 로고
    • Aerodynamic characteristics of nebulized terbutaline sulphate using the andersen cascade impactor compared to the Next Generation Impactor
    • M.E. Abdelrahim Aerodynamic characteristics of nebulized terbutaline sulphate using the andersen cascade impactor compared to the Next Generation Impactor Pharm. Dev. Technol. 16 2011 137 145
    • (2011) Pharm. Dev. Technol. , vol.16 , pp. 137-145
    • Abdelrahim, M.E.1
  • 13
    • 84866125588 scopus 로고    scopus 로고
    • Effect of sampling volume on dry powder inhaler (DPI)-emitted aerosol aerodynamic particle size distributions (APSDs) measured by the Next-Generation Pharmaceutical Impactor (NGI) and the Andersen Eight-Stage Cascade Impactor (ACI)
    • H. Mohammed, D.L. Roberts, M. Copley, M. Hammond, S.C. Nichols, and J.P. Mitchell Effect of sampling volume on dry powder inhaler (DPI)-emitted aerosol aerodynamic particle size distributions (APSDs) measured by the Next-Generation Pharmaceutical Impactor (NGI) and the Andersen Eight-Stage Cascade Impactor (ACI) AAPS Pharm. Sci. Tech. 13 2012 875 882
    • (2012) AAPS Pharm. Sci. Tech. , vol.13 , pp. 875-882
    • Mohammed, H.1    Roberts, D.L.2    Copley, M.3    Hammond, M.4    Nichols, S.C.5    Mitchell, J.P.6
  • 14
    • 72149093223 scopus 로고    scopus 로고
    • Pharmacopeial methodologies for determining aerodynamic mass distributions of ultra-high dose inhaler medicines
    • W. Wong, J. Crapper, H.-K. Chan, D. Traini, and P.M. Young Pharmacopeial methodologies for determining aerodynamic mass distributions of ultra-high dose inhaler medicines J. Pharmaceut. Biomed. 51 2010 853 857
    • (2010) J. Pharmaceut. Biomed. , vol.51 , pp. 853-857
    • Wong, W.1    Crapper, J.2    Chan, H.-K.3    Traini, D.4    Young, P.M.5
  • 15
    • 1642578544 scopus 로고    scopus 로고
    • Calibration and mensuration issues for the standard and modified impactor
    • S. Nichols Calibration and mensuration issues for the standard and modified impactor Pharmeuropa 14 2000 585
    • (2000) Pharmeuropa , vol.14 , pp. 585
    • Nichols, S.1
  • 16
    • 84895878772 scopus 로고    scopus 로고
    • Combined inhaled salbutamol and mannitol therapy for mucus hyper-secretion in pulmonary diseases
    • H.X. Ong, D. Traini, G. Ballerin, L. Morgan, L. Buddle, S. Scalia, and P.M. Young Combined inhaled salbutamol and mannitol therapy for mucus hyper-secretion in pulmonary diseases AAPS J. 16 2014 269 280
    • (2014) AAPS J. , vol.16 , pp. 269-280
    • Ong, H.X.1    Traini, D.2    Ballerin, G.3    Morgan, L.4    Buddle, L.5    Scalia, S.6    Young, P.M.7
  • 18
    • 2342652446 scopus 로고    scopus 로고
    • Mathematical comparison of dissolution profiles
    • J.W. Moore, and H.H. Flanner Mathematical comparison of dissolution profiles Pharm. Technol. 20 1996 64 74
    • (1996) Pharm. Technol. , vol.20 , pp. 64-74
    • Moore, J.W.1    Flanner, H.H.2
  • 20
    • 45949112470 scopus 로고    scopus 로고
    • In vitro/in vivo comparisons in pulmonary drug delivery
    • S.P. Newman, and H.K. Chan In vitro/in vivo comparisons in pulmonary drug delivery J. Aerosol Med. Pulm. Drug Deliv. 21 2008 77 84
    • (2008) J. Aerosol Med. Pulm. Drug Deliv. , vol.21 , pp. 77-84
    • Newman, S.P.1    Chan, H.K.2
  • 21
    • 79951577062 scopus 로고    scopus 로고
    • Influence of particle size on regional lung deposition - What evidence is there?
    • T.C. Carvalho, J.I. Peters, and R.O. Williams Iii Influence of particle size on regional lung deposition - what evidence is there? Int. J. Pharm. 406 2011 1 10
    • (2011) Int. J. Pharm. , vol.406 , pp. 1-10
    • Carvalho, T.C.1    Peters, J.I.2    Williams, R.O.3
  • 22
    • 0034492461 scopus 로고    scopus 로고
    • Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus andersen cascade impactor and low-flow marple personal cascade impactor
    • W.T.J. Kwong, S.L. Ho, and A.L. Coates Comparison of nebulized particle size distribution with Malvern laser diffraction analyzer versus andersen cascade impactor and low-flow marple personal cascade impactor J. Aerosol Med. 13 2000 303 314
    • (2000) J. Aerosol Med. , vol.13 , pp. 303-314
    • Kwong, W.T.J.1    Ho, S.L.2    Coates, A.L.3
  • 24
    • 65349115565 scopus 로고    scopus 로고
    • Calibration of the modified electrical low-pressure impactor (ELPI) for use with pressurized pharmaceutical aerosols
    • R. Kotian, J. Peart, J. Bryner, and P.R. Byron Calibration of the modified electrical low-pressure impactor (ELPI) for use with pressurized pharmaceutical aerosols J. Aerosol Med. Pulm. Drug Deliv. 22 2009 55 66
    • (2009) J. Aerosol Med. Pulm. Drug Deliv. , vol.22 , pp. 55-66
    • Kotian, R.1    Peart, J.2    Bryner, J.3    Byron, P.R.4
  • 26
    • 84930195376 scopus 로고    scopus 로고
    • Median mass aerodynamic diameter (MMAD) and fine particle fraction (FPF): Influence on lung deposition?
    • C. Van Holsbeke, J. Marshall, J. De Backer, and W. Vos Median mass aerodynamic diameter (MMAD) and fine particle fraction (FPF): influence on lung deposition? Eur. Respir. J. 2014 44
    • (2014) Eur. Respir. J. , pp. 44
    • Van Holsbeke, C.1    Marshall, J.2    De Backer, J.3    Vos, W.4
  • 27
    • 30444452988 scopus 로고    scopus 로고
    • Regional lung deposition and bronchodilator response as a function of β2-agonist particle size
    • O.S. Usmani, M.F. Biddiscombe, and P.J. Barnes Regional lung deposition and bronchodilator response as a function of β2-agonist particle size Am. J. Respir. Crit. Care Med. 172 2005 1497 1504
    • (2005) Am. J. Respir. Crit. Care Med. , vol.172 , pp. 1497-1504
    • Usmani, O.S.1    Biddiscombe, M.F.2    Barnes, P.J.3
  • 28
    • 0021997262 scopus 로고
    • Fractional deposition from a jet nebulizer: How it differs from a metered dose inhaler
    • R.A. Lewis, and J.S. Fleming Fractional deposition from a jet nebulizer: how it differs from a metered dose inhaler Brit. J. Dis. Chest. 79 1985 361 367
    • (1985) Brit. J. Dis. Chest. , vol.79 , pp. 361-367
    • Lewis, R.A.1    Fleming, J.S.2
  • 29
    • 0025327891 scopus 로고
    • Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution
    • B. Zainudin, M. Biddiscombe, S. Tolfree, M. Short, and S. Spiro Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution Thorax 45 1990 469 473
    • (1990) Thorax , vol.45 , pp. 469-473
    • Zainudin, B.1    Biddiscombe, M.2    Tolfree, S.3    Short, M.4    Spiro, S.5
  • 30
    • 0019377972 scopus 로고
    • Deposition of pressurised aerosols in the human respiratory tract
    • S.P. Newman, D. Pavia, F. Morén, N. Sheahan, and S.W. Clarke Deposition of pressurised aerosols in the human respiratory tract Thorax 36 1981 52 55
    • (1981) Thorax , vol.36 , pp. 52-55
    • Newman, S.P.1    Pavia, D.2    Morén, F.3    Sheahan, N.4    Clarke, S.W.5
  • 31
    • 0033407085 scopus 로고    scopus 로고
    • Deposition of fenoterol from pressurized metered dose inhalers containing hydrofluoroalkanes
    • S. Newman, G. Pitcairn, K. Steed, A. Harrison, and J. Nagel Deposition of fenoterol from pressurized metered dose inhalers containing hydrofluoroalkanes J. Allergy Clin. Immunol. 104 1999 s253 s257
    • (1999) J. Allergy Clin. Immunol. , vol.104 , pp. s253-s257
    • Newman, S.1    Pitcairn, G.2    Steed, K.3    Harrison, A.4    Nagel, J.5
  • 32
    • 0028031785 scopus 로고
    • Effect of different modes of inhalation on drug delivery from a dry powder inhaler
    • S.P. Newman, A. Hollingworth, and A.R. Clark Effect of different modes of inhalation on drug delivery from a dry powder inhaler Int. J. Pharm. 102 1994 127 132
    • (1994) Int. J. Pharm. , vol.102 , pp. 127-132
    • Newman, S.P.1    Hollingworth, A.2    Clark, A.R.3
  • 33
    • 0027971169 scopus 로고
    • Nebuliser performance, pharmacokinetics, airways and systemic effects of salbutamol given via a novel nebuliser delivery system ("Ventstream")
    • D.M. Newnham, and B.J. Lipworth Nebuliser performance, pharmacokinetics, airways and systemic effects of salbutamol given via a novel nebuliser delivery system ("Ventstream") Thorax 49 1994 762 770
    • (1994) Thorax , vol.49 , pp. 762-770
    • Newnham, D.M.1    Lipworth, B.J.2
  • 34
    • 0030000538 scopus 로고    scopus 로고
    • Lung bioavailability of chlorofluorocarbon free, dry powder and chlorofluorocarbon containing formulations of salbutamol
    • D. Clark, and B. Lipworth Lung bioavailability of chlorofluorocarbon free, dry powder and chlorofluorocarbon containing formulations of salbutamol Br. J. Clin. Pharmacol. 41 1996 247 249
    • (1996) Br. J. Clin. Pharmacol. , vol.41 , pp. 247-249
    • Clark, D.1    Lipworth, B.2
  • 35
    • 0030920476 scopus 로고    scopus 로고
    • Comparative lung delivery of salbutamol given via Turbuhaler and Diskus dry powder inhaler devices
    • B. Lipworth, and D. Clark Comparative lung delivery of salbutamol given via Turbuhaler and Diskus dry powder inhaler devices Eur. J. Clin. Pharmacol. 53 1997 47 49
    • (1997) Eur. J. Clin. Pharmacol. , vol.53 , pp. 47-49
    • Lipworth, B.1    Clark, D.2
  • 36
    • 0027362604 scopus 로고
    • Comparison of the extrapulmonary β2-adrenoceptor responses and pharmacokinetics of salbutamol given by standard metered dose-inhaler and modified actuator device
    • D. Newnham, D. McDevitt, and B. Lipworth Comparison of the extrapulmonary β2-adrenoceptor responses and pharmacokinetics of salbutamol given by standard metered dose-inhaler and modified actuator device Br. J. Clin. Pharmacol. 36 1993 445 450
    • (1993) Br. J. Clin. Pharmacol. , vol.36 , pp. 445-450
    • Newnham, D.1    McDevitt, D.2    Lipworth, B.3
  • 37
    • 84912083677 scopus 로고    scopus 로고
    • Rapid interrogation of the physical and chemical characteristics of salbutamol sulphate aerosol from a pressurised metered-dose inhaler (pMDI)
    • H.-J. Tong, C. Fitzgerald, P. Gallimore, M. Kalberer, M. Kuimova, P. Seville, A. Ward, and F. Pope Rapid interrogation of the physical and chemical characteristics of salbutamol sulphate aerosol from a pressurised metered-dose inhaler (pMDI) Chem. Commun. 50 2014 15499 15502
    • (2014) Chem. Commun. , vol.50 , pp. 15499-15502
    • Tong, H.-J.1    Fitzgerald, C.2    Gallimore, P.3    Kalberer, M.4    Kuimova, M.5    Seville, P.6    Ward, A.7    Pope, F.8
  • 38
    • 59849094684 scopus 로고    scopus 로고
    • The permeability of large molecular weight solutes following particle delivery to air-interfaced cells that model the respiratory mucosa
    • C. Grainger, L. Greenwell, G. Martin, and B. Forbes The permeability of large molecular weight solutes following particle delivery to air-interfaced cells that model the respiratory mucosa Eur. J. Pharm. Biopharm. 71 2009 318 324
    • (2009) Eur. J. Pharm. Biopharm. , vol.71 , pp. 318-324
    • Grainger, C.1    Greenwell, L.2    Martin, G.3    Forbes, B.4
  • 39
    • 0017761344 scopus 로고
    • Comparison of the bronchodilator effects of salbutamol inhaled as a dry powder and by conventional pressurised aerosol
    • D. Duncan, I. Paterson, D. Harris, and G. Crompton Comparison of the bronchodilator effects of salbutamol inhaled as a dry powder and by conventional pressurised aerosol Br. J. Clin. Pharmacol. 4 1977 669 671
    • (1977) Br. J. Clin. Pharmacol. , vol.4 , pp. 669-671
    • Duncan, D.1    Paterson, I.2    Harris, D.3    Crompton, G.4
  • 40
    • 0018775233 scopus 로고
    • Long-term comparison of salbutamol powder with salbutamol aerosol in asthmatic out-patients
    • J. Hartley, S. Nogrady, and A. Seaton Long-term comparison of salbutamol powder with salbutamol aerosol in asthmatic out-patients Brit. J. Dis. Chest. 73 1979 271 276
    • (1979) Brit. J. Dis. Chest. , vol.73 , pp. 271-276
    • Hartley, J.1    Nogrady, S.2    Seaton, A.3
  • 41
    • 0030777037 scopus 로고    scopus 로고
    • Pilot study of bronchodilator response to inhaled albuterol delivered by metered-dose inhaler and a novel dry powder inhaler
    • J.P. Kemp, M.R. Hill, L.M. Vaughan, E.O. Meltzer, M.J. Welch, and N.K. Ostrom Pilot study of bronchodilator response to inhaled albuterol delivered by metered-dose inhaler and a novel dry powder inhaler Ann. Allergy Asthma Immunol. 79 1997 322 326
    • (1997) Ann. Allergy Asthma Immunol. , vol.79 , pp. 322-326
    • Kemp, J.P.1    Hill, M.R.2    Vaughan, L.M.3    Meltzer, E.O.4    Welch, M.J.5    Ostrom, N.K.6
  • 42
    • 0031963823 scopus 로고    scopus 로고
    • Lung delivery of non-CFC salbutamol via small volume metal spacer and large volume plastic spacer devices compared with an open vent jet nebulizer
    • B. Lipworth, and D. Clark Lung delivery of non-CFC salbutamol via small volume metal spacer and large volume plastic spacer devices compared with an open vent jet nebulizer Br. J. Clin. Pharmacol. 45 1998 160 163
    • (1998) Br. J. Clin. Pharmacol. , vol.45 , pp. 160-163
    • Lipworth, B.1    Clark, D.2
  • 43
    • 13944254128 scopus 로고    scopus 로고
    • Comparison of the effects of nebulised and inhaled salbutamol on breathlessness in severe COPD
    • P.J. Poole, R. Saini, S.M. Brodie, and P.N. Black Comparison of the effects of nebulised and inhaled salbutamol on breathlessness in severe COPD Resp. Med. 99 2005 372 376
    • (2005) Resp. Med. , vol.99 , pp. 372-376
    • Poole, P.J.1    Saini, R.2    Brodie, S.M.3    Black, P.N.4
  • 44
    • 0037270144 scopus 로고    scopus 로고
    • Effect of propellant on the pharmacokinetics and pharmacodynamics of inhaled albuterol in asthmatic subjects
    • V. Joguparthi, P. Breen, C. Compadre, X. Zhou, L. Gann, F.C. Hiller, and P. Anderson Effect of propellant on the pharmacokinetics and pharmacodynamics of inhaled albuterol in asthmatic subjects J. Aerosol Med. 16 2003 47 53
    • (2003) J. Aerosol Med. , vol.16 , pp. 47-53
    • Joguparthi, V.1    Breen, P.2    Compadre, C.3    Zhou, X.4    Gann, L.5    Hiller, F.C.6    Anderson, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.