메뉴 건너뛰기




Volumn 13, Issue 3, 2012, Pages 875-882

Effect of sampling volume on dry powder inhaler (DPI)-emitted aerosol aerodynamic particle size distributions (APSDs) measured by the next-generation pharmaceutical impactor (NGI) and the andersen eight-stage cascade impactor (ACI)

Author keywords

cascade impactor; compendial method; dry powder inhaler; sample volume

Indexed keywords

AEROSOL; ANDERSEN EIGHT STAGE CASCADE IMPACTOR; ARTICLE; CONTROLLED STUDY; INSTRUMENT; MEDICAL LITERATURE; METHODOLOGY; NEXT GENERATION PHARMACEUTICAL IMPACTOR; PARTICLE SIZE; POWDER INHALER; PRESSURE; PRIORITY JOURNAL; SAMPLING;

EID: 84866125588     PISSN: None     EISSN: 15309932     Source Type: Journal    
DOI: 10.1208/s12249-012-9797-0     Document Type: Article
Times cited : (31)

References (13)
  • 1
    • 65549151221 scopus 로고    scopus 로고
    • European Directorate for the Quality of Medicines and Healthcare (EDQM): European Pharmacopeia 6(8). Chapter 2.9.18 Strasbourg: Council of Europe
    • European Directorate for the Quality of Medicines and Healthcare (EDQM): European Pharmacopeia 6(8). Chapter 2.9.18. Preparations for inhalations: aerodynamic assessment of fine particles. Strasbourg: Council of Europe; 2010.
    • (2010) Preparations for Inhalations: Aerodynamic Assessment of Fine Particles
  • 2
    • 84866075303 scopus 로고    scopus 로고
    • US Pharmacopeial Convention. United States Pharmacopeia; USP 33-NF 28 United States Pharmacopeia, Rockville, MD, USA
    • US Pharmacopeial Convention. United States Pharmacopeia; USP 33-NF 28; chapter 601physical tests and determinations: aerosols. United States Pharmacopeia, Rockville, MD, USA; 2010.
    • (2010) Chapter 601-physical Tests and Determinations: Aerosols
  • 3
    • 1642515071 scopus 로고    scopus 로고
    • Cascade impactors for the size characterization of aerosols from medical inhalers: Their uses and limitations
    • 14977427 10.1089/089426803772455622 1:CAS:528:DC%2BD2cXltFagtw%3D%3D
    • Mitchell JP, Nagel MW. Cascade impactors for the size characterization of aerosols from medical inhalers: their uses and limitations. J Aerosol Med. 2003;16(4):341-77.
    • (2003) J Aerosol Med , vol.16 , Issue.4 , pp. 341-377
    • Mitchell, J.P.1    Nagel, M.W.2
  • 4
    • 25844483208 scopus 로고    scopus 로고
    • Revised internal volumes to those provided by Mitchell JP and Nagel MW in cascade impactors for the size characterization of aerosols from medical inhalers: Their uses and limitations
    • 16181010 10.1089/jam.2005.18.364 1:STN:280:DC%2BD2MrhtVGmtQ%3D%3D
    • Copley M, Smurthwaite M, Roberts DL, Mitchell JP. Revised internal volumes to those provided by Mitchell JP and Nagel MW in cascade impactors for the size characterization of aerosols from medical inhalers: their uses and limitations. J Aerosol Med. 2005;18(3):364-6.
    • (2005) J Aerosol Med , vol.18 , Issue.3 , pp. 364-366
    • Copley, M.1    Smurthwaite, M.2    Roberts, D.L.3    Mitchell, J.P.4
  • 5
    • 38049138950 scopus 로고    scopus 로고
    • In vitro and in vivo aspects of cascade impactor tests and inhaler performance: A review
    • 10.1208/pt0804110
    • Mitchell JP, Newman S, Chan H-K. In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review. AAPS PharmSciTechnol. 2007;8(4):237-48.
    • (2007) AAPS PharmSciTechnol , vol.8 , Issue.4 , pp. 237-248
    • Mitchell, J.P.1    Newman, S.2    Chan, H.-K.3
  • 6
    • 29844443399 scopus 로고    scopus 로고
    • Analysis of cascade impactor mass distributions
    • 16379619 10.1089/jam.2005.18.439 1:CAS:528:DC%2BD2MXhtlCntbnL
    • Dunbar C, Mitchell J. Analysis of cascade impactor mass distributions. J Aerosol Med. 2005;18(4):439-51.
    • (2005) J Aerosol Med , vol.18 , Issue.4 , pp. 439-451
    • Dunbar, C.1    Mitchell, J.2
  • 8
    • 1642578544 scopus 로고    scopus 로고
    • Calibration and mensuration issues for the standard and modified impactor
    • Nichols SC. Calibration and mensuration issues for the standard and modified impactor. Pharmeuropa. 2000;12(4):585.
    • (2000) Pharmeuropa , vol.12 , Issue.4 , pp. 585
    • Nichols, S.C.1
  • 9
    • 0023994394 scopus 로고
    • An assessment of an Andersen mark-II cascade impactor
    • 10.1016/0021-8502(88)90224-8
    • Mitchell JP, Costa PA, Waters S. An assessment of an Andersen mark-II cascade impactor. J Aerosol Sci. 1987;19:213-21.
    • (1987) J Aerosol Sci , vol.19 , pp. 213-221
    • Mitchell, J.P.1    Costa, P.A.2    Waters, S.3
  • 10
    • 84866083069 scopus 로고    scopus 로고
    • Flow rate ramp profile effects on the emitted dose from dry powder inhalers
    • The Aerosol Society Edinburgh
    • Beron K, Grabek CE, Jung JA, Shelton CM. Flow rate ramp profile effects on the emitted dose from dry powder inhalers. In: Drug delivery to the lungs, 19. Edinburgh: The Aerosol Society; 2008. p. 61-4.
    • (2008) Drug Delivery to the Lungs, 19 , pp. 61-64
    • Beron, K.1    Grabek, C.E.2    Jung, J.A.3    Shelton, C.M.4
  • 13
    • 76549118365 scopus 로고    scopus 로고
    • Transient impactor behavior during the testing of dry-powder inhalers via compendial methods
    • The Aerosol Society Edinburgh
    • Roberts DL, Chiruta M. Transient impactor behavior during the testing of dry-powder inhalers via compendial methods. In: Drug delivery to the lungs, 18. Edinburgh: The Aerosol Society; 2007. p. 202-5.
    • (2007) Drug Delivery to the Lungs, 18 , pp. 202-205
    • Roberts, D.L.1    Chiruta, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.