메뉴 건너뛰기




Volumn 14, Issue , 2015, Pages 217-225

Additively manufactured porous tantalum implants

Author keywords

Bone regeneration; Porous biomaterials; Selective laser melting; Tantalum

Indexed keywords

ALUMINUM ALLOYS; BIOCOMPATIBILITY; BIOMEDICAL EQUIPMENT; BONE; MELTING; METAL IMPLANTS; TANTALUM; TANTALUM ALLOYS; TERNARY ALLOYS; TITANIUM ALLOYS; VANADIUM ALLOYS;

EID: 84921822933     PISSN: 17427061     EISSN: 18787568     Source Type: Journal    
DOI: 10.1016/j.actbio.2014.12.003     Document Type: Article
Times cited : (362)

References (99)
  • 1
    • 35448944365 scopus 로고    scopus 로고
    • The operation of the century: Total hip replacement
    • Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet 2007;370:1508-19.
    • (2007) Lancet , vol.370 , pp. 1508-1519
    • Learmonth, I.D.1    Young, C.2    Rorabeck, C.3
  • 5
    • 34848862402 scopus 로고    scopus 로고
    • Treatment options and allograft use in revision total hip arthroplasty the acetabulum
    • Brubaker SM, Brown TE, Manaswi A, Mihalko WM, Cui Q, Saleh KJ. Treatment options and allograft use in revision total hip arthroplasty the acetabulum. J Arthrop 2007;22:52-6.
    • (2007) J Arthrop , vol.22 , pp. 52-56
    • Brubaker, S.M.1    Brown, T.E.2    Manaswi, A.3    Mihalko, W.M.4    Cui, Q.5    Saleh, K.J.6
  • 7
    • 0028059248 scopus 로고
    • Biological performance of tantalum
    • Black J. Biological performance of tantalum. Clin Mater 1994;16:167-73.
    • (1994) Clin Mater , vol.16 , pp. 167-173
    • Black, J.1
  • 9
    • 0035372012 scopus 로고    scopus 로고
    • Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium
    • Matsuno H, Yokoyama A, Watari F, Uo M, Kawasaki T. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials 2001;22:1253-62.
    • (2001) Biomaterials , vol.22 , pp. 1253-1262
    • Matsuno, H.1    Yokoyama, A.2    Watari, F.3    Uo, M.4    Kawasaki, T.5
  • 10
    • 0025315708 scopus 로고
    • Qualitative interfacial study between bone and tantalum, niobium or commercially pure titanium
    • Johansson CB, Hansson HA, Albrektsson T. Qualitative interfacial study between bone and tantalum, niobium or commercially pure titanium. Biomaterials 1990;11:277-80.
    • (1990) Biomaterials , vol.11 , pp. 277-280
    • Johansson, C.B.1    Hansson, H.A.2    Albrektsson, T.3
  • 12
    • 47049109396 scopus 로고    scopus 로고
    • Morphology, proliferation, and osteogenic differentiation of mesenchymal stem cells cultured on titanium, tantalum, and chromium surfaces
    • Stiehler M, Lind M, Mygind T, Baatrup A, Dolatshahi-Pirouz A, Li H, et al. Morphology, proliferation, and osteogenic differentiation of mesenchymal stem cells cultured on titanium, tantalum, and chromium surfaces. J Biomed Mater Res, Part A 2008;86:448-58.
    • (2008) J Biomed Mater Res, Part A , vol.86 , pp. 448-458
    • Stiehler, M.1    Lind, M.2    Mygind, T.3    Baatrup, A.4    Dolatshahi-Pirouz, A.5    Li, H.6
  • 13
    • 84878865789 scopus 로고    scopus 로고
    • Porous tantalum coatings prepared by vacuum plasma spraying enhance BMSCs osteogenic differentiation and bone regeneration in vitro and in vivo
    • Tang Z, Xie Y, Yang F, Huang Y, Wang C, Dai K, et al. Porous tantalum coatings prepared by vacuum plasma spraying enhance BMSCs osteogenic differentiation and bone regeneration in vitro and in vivo. PLoS One 2013;8:e66263.
    • (2013) PLoS One , vol.8 , pp. e66263
    • Tang, Z.1    Xie, Y.2    Yang, F.3    Huang, Y.4    Wang, C.5    Dai, K.6
  • 14
    • 0036132321 scopus 로고    scopus 로고
    • Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid
    • Miyazaki T, Kim H-M, Kokubo T, Ohtsuki C, Kato H, Nakamura T. Mechanism of bonelike apatite formation on bioactive tantalum metal in a simulated body fluid. Biomaterials 2002;23:827-32.
    • (2002) Biomaterials , vol.23 , pp. 827-832
    • Miyazaki, T.1    Kim, H.-M.2    Kokubo, T.3    Ohtsuki, C.4    Kato, H.5    Nakamura, T.6
  • 15
    • 43049088087 scopus 로고    scopus 로고
    • Enhanced gap filling and osteoconduction associated with alendronate-calcium phosphate-coated porous tantalum
    • Garbuz DS, Hu Y, Kim WY, Duan K, Masri BA, Oxland TR, et al. Enhanced gap filling and osteoconduction associated with alendronate-calcium phosphate-coated porous tantalum. J Bone Joint Surg Am 2008;90:1090-100.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1090-1100
    • Garbuz, D.S.1    Hu, Y.2    Kim, W.Y.3    Duan, K.4    Masri, B.A.5    Oxland, T.R.6
  • 16
    • 66249119369 scopus 로고    scopus 로고
    • Spatial and temporal changes in the morphology of preosteoblastic cells seeded on microstructured tantalum surfaces
    • Justesen J, Lorentzen M, Andersen LK, Hansen O, Chevallier J, Modin C, et al. Spatial and temporal changes in the morphology of preosteoblastic cells seeded on microstructured tantalum surfaces. J Biomed Mater Res, Part A 2009;89:885-94.
    • (2009) J Biomed Mater Res, Part A , vol.89 , pp. 885-894
    • Justesen, J.1    Lorentzen, M.2    Andersen, L.K.3    Hansen, O.4    Chevallier, J.5    Modin, C.6
  • 17
    • 84867482235 scopus 로고    scopus 로고
    • Study on the anticorrosion, biocompatibility, and osteoinductivity of tantalum decorated with tantalum oxide nanotube array films
    • Wang N, Li H, Wang J, Chen S, Ma Y, Zhang Z. Study on the anticorrosion, biocompatibility, and osteoinductivity of tantalum decorated with tantalum oxide nanotube array films. ACS Appl Mater Interfaces 2012;4:4516-23.
    • (2012) ACS Appl Mater Interfaces , vol.4 , pp. 4516-4523
    • Wang, N.1    Li, H.2    Wang, J.3    Chen, S.4    Ma, Y.5    Zhang, Z.6
  • 21
    • 33646870140 scopus 로고    scopus 로고
    • Monitoring cell adhesion on tantalum and oxidised polystyrene using a quartz crystal microbalance with dissipation
    • Lord MS, Modin C, Foss M, Duch M, Simmons A, Pedersen FS, et al. Monitoring cell adhesion on tantalum and oxidised polystyrene using a quartz crystal microbalance with dissipation. Biomaterials 2006;27:4529-37.
    • (2006) Biomaterials , vol.27 , pp. 4529-4537
    • Lord, M.S.1    Modin, C.2    Foss, M.3    Duch, M.4    Simmons, A.5    Pedersen, F.S.6
  • 26
    • 0036677824 scopus 로고    scopus 로고
    • The use of roentgen stereophotogrammetry to study micromotion of orthopaedic implants
    • Valstar ER, Nelissen RGHH, Reiber JHC, Rozing PM. The use of roentgen stereophotogrammetry to study micromotion of orthopaedic implants. J Photogramm Remote Sens 2002;56:376-89.
    • (2002) J Photogramm Remote Sens , vol.56 , pp. 376-389
    • Valstar, E.R.1    Rghh, N.2    Reiber, J.H.C.3    Rozing, P.M.4
  • 27
    • 84863982768 scopus 로고    scopus 로고
    • Preliminary study of the biomechanical behavior and physical characteristics of tantalum (Ta)-coated prostheses
    • Duan Y, Liu L, Wang L, Guo F, Li H, Shi L, et al. Preliminary study of the biomechanical behavior and physical characteristics of tantalum (Ta)-coated prostheses. J Orthop Sci 2012;17:173-85.
    • (2012) J Orthop Sci , vol.17 , pp. 173-185
    • Duan, Y.1    Liu, L.2    Wang, L.3    Guo, F.4    Li, H.5    Shi, L.6
  • 28
    • 84876664616 scopus 로고    scopus 로고
    • Tantalum coating on porous Ti6Al4V scaffold using chemical vapor deposition and preliminary biological evaluation
    • Li X, Wang L, Yu X, Feng Y, Wang C, Yang K, et al. Tantalum coating on porous Ti6Al4V scaffold using chemical vapor deposition and preliminary biological evaluation. Mater Sci Eng C Mater Biol Appl 2013;33:2987-94.
    • (2013) Mater Sci Eng C Mater Biol Appl , vol.33 , pp. 2987-2994
    • Li, X.1    Wang, L.2    Yu, X.3    Feng, Y.4    Wang, C.5    Yang, K.6
  • 29
    • 0032886563 scopus 로고    scopus 로고
    • Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial
    • Bobyn JD, Stackpool GJ, Hacking SA, Tanzer M, Krygier JJ. Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial. J Bone Joint Surg Br 1999;81:907-14.
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 907-914
    • Bobyn, J.D.1    Stackpool, G.J.2    Hacking, S.A.3    Tanzer, M.4    Krygier, J.J.5
  • 36
    • 55349087917 scopus 로고    scopus 로고
    • A new era in porous metals: Applications in orthopaedics
    • Levine B. A new era in porous metals: applications in orthopaedics. Adv Eng Mater 2008;10:788-92.
    • (2008) Adv Eng Mater , vol.10 , pp. 788-792
    • Levine, B.1
  • 38
    • 39049088534 scopus 로고    scopus 로고
    • Primary human osteoblasts grow into porous tantalum and maintain an osteoblastic phenotype
    • Welldon KJ, Atkins GJ, Howie DW, Findlay DM. Primary human osteoblasts grow into porous tantalum and maintain an osteoblastic phenotype. J Biomed Mater Res, Part A 2008;84:691-701.
    • (2008) J Biomed Mater Res, Part A , vol.84 , pp. 691-701
    • Welldon, K.J.1    Atkins, G.J.2    Howie, D.W.3    Findlay, D.M.4
  • 39
    • 79951861489 scopus 로고    scopus 로고
    • Porous tantalum stimulates the proliferation and osteogenesis of osteoblasts from elderly female patients
    • Sagomonyants KB, Hakim-Zargar M, Jhaveri A, Aronow MS, Gronowicz G. Porous tantalum stimulates the proliferation and osteogenesis of osteoblasts from elderly female patients. J Orthop Res 2011;29:609-16.
    • (2011) J Orthop Res , vol.29 , pp. 609-616
    • Sagomonyants, K.B.1    Hakim-Zargar, M.2    Jhaveri, A.3    Aronow, M.S.4    Gronowicz, G.5
  • 41
    • 80755153176 scopus 로고    scopus 로고
    • Oxygen consumption, acidification and migration capacity of human primary osteoblasts within a three-dimensional tantalum scaffold
    • Jonitz A, Lochner K, Lindner T, Hansmann D, Marrot A, Bader R. Oxygen consumption, acidification and migration capacity of human primary osteoblasts within a three-dimensional tantalum scaffold. J Mater Sci - Mater Med 2011;22:2089-95.
    • (2011) J Mater Sci - Mater Med , vol.22 , pp. 2089-2095
    • Jonitz, A.1    Lochner, K.2    Lindner, T.3    Hansmann, D.4    Marrot, A.5    Bader, R.6
  • 42
    • 58149383795 scopus 로고    scopus 로고
    • Activation of human leukocytes on tantalum trabecular metal in comparison to commonly used orthopedic metal implant materials
    • Schildhauer TA, Peter E, Muhr G, Koller M. Activation of human leukocytes on tantalum trabecular metal in comparison to commonly used orthopedic metal implant materials. J Biomed Mater Res, Part A 2009;88:332-41.
    • (2009) J Biomed Mater Res, Part A , vol.88 , pp. 332-341
    • Schildhauer, T.A.1    Peter, E.2    Muhr, G.3    Koller, M.4
  • 45
    • 33846975433 scopus 로고    scopus 로고
    • Evaluation of machining methods for trabecular metal implants in a rabbit intramedullary osseointegration model
    • Deglurkar M, Davy DT, Stewart M, Goldberg VM, Welter JF. Evaluation of machining methods for trabecular metal implants in a rabbit intramedullary osseointegration model. J Biomed Mater Res B Appl Biomater 2007;80:528-40.
    • (2007) J Biomed Mater Res B Appl Biomater , vol.80 , pp. 528-540
    • Deglurkar, M.1    Davy, D.T.2    Stewart, M.3    Goldberg, V.M.4    Welter, J.F.5
  • 46
    • 84863992309 scopus 로고    scopus 로고
    • Histologic retrieval analysis of a porous tantalum metal implant in an infected primary total knee arthroplasty
    • Sambaziotis C, Lovy AJ, Koller KE, Bloebaum RD, Hirsh DM, Kim SJ. Histologic retrieval analysis of a porous tantalum metal implant in an infected primary total knee arthroplasty. J Arthrop 2012;27(1413):e5-9.
    • (2012) J Arthrop , vol.27 , Issue.1413 , pp. e5-e9
    • Sambaziotis, C.1    Lovy, A.J.2    Koller, K.E.3    Bloebaum, R.D.4    Hirsh, D.M.5    Kim, S.J.6
  • 47
    • 84878212668 scopus 로고    scopus 로고
    • Ingrowth Retrieval Study Group. Bone ingrowth in well-fixed retrieved porous tantalum implants
    • Hanzlik JA, Day JS, Ingrowth Retrieval Study Group. Bone ingrowth in well-fixed retrieved porous tantalum implants. J Arthrop 2013;28:922-7.
    • (2013) J Arthrop , vol.28 , pp. 922-927
    • Hanzlik, J.A.1    Day, J.S.2
  • 48
    • 84880077472 scopus 로고    scopus 로고
    • Failure of porous tantalum cervical interbody fusion devices: Two-year results from a prospective, randomized, multicenter clinical study
    • Kasliwal MK, Baskin DS, Traynelis VC. Failure of porous tantalum cervical interbody fusion devices: two-year results from a prospective, randomized, multicenter clinical study. J Spinal Disorders Tech 2013;26:239-45.
    • (2013) J Spinal Disorders Tech , vol.26 , pp. 239-245
    • Kasliwal, M.K.1    Baskin, D.S.2    Traynelis, V.C.3
  • 49
    • 39749113720 scopus 로고    scopus 로고
    • The use of a tantalum-based augmentation patella in patients with a previous patellectomy
    • Kwong Y, Desai VV. The use of a tantalum-based augmentation patella in patients with a previous patellectomy. Knee 2008;15:91-4.
    • (2008) Knee , vol.15 , pp. 91-94
    • Kwong, Y.1    Desai, V.V.2
  • 53
    • 70449411126 scopus 로고    scopus 로고
    • Evaluation of the mechanical behavior of a direct compression molded porous tantalum-UHMWPE construct: A microstructural model
    • Vivanco J, Fang Z, Levine D, Ploeg HL. Evaluation of the mechanical behavior of a direct compression molded porous tantalum-UHMWPE construct: a microstructural model. J Appl Biomater Biomech 2009;7:34-42.
    • (2009) J Appl Biomater Biomech , vol.7 , pp. 34-42
    • Vivanco, J.1    Fang, Z.2    Levine, D.3    Ploeg, H.L.4
  • 54
    • 84873972408 scopus 로고    scopus 로고
    • Development of new metallic alloys for biomedical applications
    • Niinomi M, Nakai M, Hieda J. Development of new metallic alloys for biomedical applications. Acta Biomater 2012;8:3888-903.
    • (2012) Acta Biomater , vol.8 , pp. 3888-3903
    • Niinomi, M.1    Nakai, M.2    Hieda, J.3
  • 55
    • 67650137145 scopus 로고    scopus 로고
    • Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity
    • Kosashvili Y, Backstein D, Safir O, Lakstein D, Gross AE. Acetabular revision using an anti-protrusion (ilio-ischial) cage and trabecular metal acetabular component for severe acetabular bone loss associated with pelvic discontinuity. J Bone Joint Surg Br 2009;91-B:870-6.
    • (2009) J Bone Joint Surg Br , vol.91 B , pp. 870-876
    • Kosashvili, Y.1    Backstein, D.2    Safir, O.3    Lakstein, D.4    Gross, A.E.5
  • 57
    • 84891675594 scopus 로고    scopus 로고
    • Use of porous tantalum for acetabular reconstruction in revision hip arthroplasty
    • Issack PS. Use of porous tantalum for acetabular reconstruction in revision hip arthroplasty. J Bone Joint Surg Am 2013;95:1981-7.
    • (2013) J Bone Joint Surg Am , vol.95 , pp. 1981-1987
    • Issack, P.S.1
  • 58
    • 33750697986 scopus 로고    scopus 로고
    • Survivorship analysis and radiographic outcome following tantalum rod insertion for osteonecrosis of the femoral head
    • Veillette CJ, Mehdian H, Schemitsch EH, McKee MD. Survivorship analysis and radiographic outcome following tantalum rod insertion for osteonecrosis of the femoral head. J Bone Joint Surg Am 2006;88(Suppl. 3):48-55.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 48-55
    • Veillette, C.J.1    Mehdian, H.2    Schemitsch, E.H.3    McKee, M.D.4
  • 61
    • 33745997077 scopus 로고    scopus 로고
    • Hedrocel trabecular metal monoblock acetabular cups: Mid-term results
    • Mulier M, Rys B, Moke L. Hedrocel trabecular metal monoblock acetabular cups: mid-term results. Acta Orthop Belg 2006;72:326-31.
    • (2006) Acta Orthop Belg , vol.72 , pp. 326-331
    • Mulier, M.1    Rys, B.2    Moke, L.3
  • 62
    • 73149110420 scopus 로고    scopus 로고
    • Clinical and radiological evaluation of modular trabecular metal acetabular cups. Short-term results in 64 hips
    • Simon JP, Bellemans J. Clinical and radiological evaluation of modular trabecular metal acetabular cups. Short-term results in 64 hips. Acta Orthop Belg 2009;75:623-30.
    • (2009) Acta Orthop Belg , vol.75 , pp. 623-630
    • Simon, J.P.1    Bellemans, J.2
  • 64
    • 37849010328 scopus 로고    scopus 로고
    • Use of porous tantalum metaphyseal cones for severe tibial bone loss during revision total knee replacement
    • Meneghini RM, Lewallen DG, Hanssen AD. Use of porous tantalum metaphyseal cones for severe tibial bone loss during revision total knee replacement. J Bone Joint Surg Am 2008;90:78-84.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 78-84
    • Meneghini, R.M.1    Lewallen, D.G.2    Hanssen, A.D.3
  • 65
    • 79952369482 scopus 로고    scopus 로고
    • Early results of the use of tantalum femoral cones for revision total knee arthroplasty
    • Howard JL, Kudera J, Lewallen DG, Hanssen AD. Early results of the use of tantalum femoral cones for revision total knee arthroplasty. J Bone Joint Surg Am 2011;93:478-84.
    • (2011) J Bone Joint Surg Am , vol.93 , pp. 478-484
    • Howard, J.L.1    Kudera, J.2    Lewallen, D.G.3    Hanssen, A.D.4
  • 66
    • 77950902830 scopus 로고    scopus 로고
    • Comparison of bone mineral density between porous tantalum and cemented tibial total knee arthroplasty components
    • Minoda Y, Kobayashi A, Iwaki H, Ikebuchi M, Inori F, Takaoka K. Comparison of bone mineral density between porous tantalum and cemented tibial total knee arthroplasty components. J Bone Joint Surg Am 2010;92:700-6.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 700-706
    • Minoda, Y.1    Kobayashi, A.2    Iwaki, H.3    Ikebuchi, M.4    Inori, F.5    Takaoka, K.6
  • 67
    • 84892482504 scopus 로고    scopus 로고
    • Mid-term results of total knee arthroplasty with a porous tantalum monoblock tibial component
    • Hayakawa K, Date H, Tsujimura S, Nojiri S, Yamada H, Nakagawa K. Mid-term results of total knee arthroplasty with a porous tantalum monoblock tibial component. Knee 2014;21:199-203.
    • (2014) Knee , vol.21 , pp. 199-203
    • Hayakawa, K.1    Date, H.2    Tsujimura, S.3    Nojiri, S.4    Yamada, H.5    Nakagawa, K.6
  • 68
    • 41049104182 scopus 로고    scopus 로고
    • Anterior cervical fusion with tantalum implant: A prospective randomized controlled study
    • Fernandez-Fairen M, Sala P, Dufoo Jr M, Ballester J, Murcia A, Merzthal L. Anterior cervical fusion with tantalum implant: a prospective randomized controlled study. Spine 2008;33:465-72.
    • (2008) Spine , vol.33 , pp. 465-472
    • Fernandez-Fairen, M.1    Sala, P.2    Dufoo, M.3    Ballester, J.4    Murcia, A.5    Merzthal, L.6
  • 69
    • 77951104206 scopus 로고    scopus 로고
    • Clinical and radiological evaluation of Trabecular Metal and the Smith-Robinson technique in anterior cervical fusion for degenerative disease: A prospective, randomized, controlled study with 2-year follow-up
    • Lofgren H, Engquist M, Hoffmann P, Sigstedt B, Vavruch L. Clinical and radiological evaluation of Trabecular Metal and the Smith-Robinson technique in anterior cervical fusion for degenerative disease: a prospective, randomized, controlled study with 2-year follow-up. Eur Spine J 2010;19:464-73.
    • (2010) Eur Spine J , vol.19 , pp. 464-473
    • Lofgren, H.1    Engquist, M.2    Hoffmann, P.3    Sigstedt, B.4    Vavruch, L.5
  • 70
    • 84860836277 scopus 로고    scopus 로고
    • Host bone response to polyetheretherketone versus porous tantalum implants for cervical spinal fusion in a goat model
    • Sinclair SK, Konz GJ, Dawson JM, Epperson RT, Bloebaum RD. Host bone response to polyetheretherketone versus porous tantalum implants for cervical spinal fusion in a goat model. Spine 2012;37:E571-80.
    • (2012) Spine , vol.37 , pp. E571-E580
    • Sinclair, S.K.1    Konz, G.J.2    Dawson, J.M.3    Epperson, R.T.4    Bloebaum, R.D.5
  • 71
    • 73449142806 scopus 로고    scopus 로고
    • Can porous tantalum be used to achieve ankle and subtalar arthrodesis?: A pilot study
    • Frigg A, Dougall H, Boyd S, Nigg B. Can porous tantalum be used to achieve ankle and subtalar arthrodesis?: a pilot study. Clin Orthop Relat Res 2010;468:209-16.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 209-216
    • Frigg, A.1    Dougall, H.2    Boyd, S.3    Nigg, B.4
  • 72
    • 78651083431 scopus 로고    scopus 로고
    • Poröse Metalle in orthopädischen Anwendungen - Eine Übersicht
    • Levine BR, Fabi DW. Poröse Metalle in orthopädischen Anwendungen - Eine Übersicht [Porous metals in orthopedic applications - a review]. Materialwiss Werkstofftech 2010;41:1001-10.
    • (2010) Materialwiss Werkstofftech , vol.41 , pp. 1001-1010
    • Levine, B.R.1    Fabi, D.W.2
  • 73
    • 84873209162 scopus 로고    scopus 로고
    • Porous metallic structures for orthopaedic applications: A short review of materials and technologies
    • Marin E, Fedrizzi L, Zagra L. Porous metallic structures for orthopaedic applications: a short review of materials and technologies. Eur Orthop Traumatol 2010;1:103-9.
    • (2010) Eur Orthop Traumatol , vol.1 , pp. 103-109
    • Marin, E.1    Fedrizzi, L.2    Zagra, L.3
  • 74
    • 34547491325 scopus 로고    scopus 로고
    • Selective laser melting of biocompatible metals for rapid manufacturing of medical parts
    • Vandenbroucke B, Kruth J-P. Selective laser melting of biocompatible metals for rapid manufacturing of medical parts. Rapid Prototyping J 2007;13:196-203.
    • (2007) Rapid Prototyping J , vol.13 , pp. 196-203
    • Vandenbroucke, B.1    Kruth, J.-P.2
  • 75
    • 84861603798 scopus 로고    scopus 로고
    • The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds
    • Van Bael S, Chai YC, Truscello S, Moesen M, Kerckhofs G, Van Oosterwyck H, et al. The effect of pore geometry on the in vitro biological behavior of human periosteum-derived cells seeded on selective laser-melted Ti6Al4V bone scaffolds. Acta Biomater 2012;8:2824-34.
    • (2012) Acta Biomater , vol.8 , pp. 2824-2834
    • Van Bael, S.1    Chai, Y.C.2    Truscello, S.3    Moesen, M.4    Kerckhofs, G.5    Van Oosterwyck, H.6
  • 76
    • 77955925980 scopus 로고    scopus 로고
    • Direct laser processing of a tantalum coating on titanium for bone replacement structures
    • Balla VK, Banerjee S, Bose S, Bandyopadhyay A. Direct laser processing of a tantalum coating on titanium for bone replacement structures. Acta Biomater 2010;6:2329-34.
    • (2010) Acta Biomater , vol.6 , pp. 2329-2334
    • Balla, V.K.1    Banerjee, S.2    Bose, S.3    Bandyopadhyay, A.4
  • 77
    • 77956633415 scopus 로고    scopus 로고
    • Porous tantalum structures for bone implants: Fabrication, mechanical and in vitro biological properties
    • Balla VK, Bodhak S, Bose S, Bandyopadhyay A. Porous tantalum structures for bone implants: fabrication, mechanical and in vitro biological properties. Acta Biomater 2010;6:3349-59.
    • (2010) Acta Biomater , vol.6 , pp. 3349-3359
    • Balla, V.K.1    Bodhak, S.2    Bose, S.3    Bandyopadhyay, A.4
  • 78
    • 80053646464 scopus 로고    scopus 로고
    • High strength bulk tantalum with novel gradient structure within a particle fabricated by spark plasma sintering
    • Zhang YS, Zhang XM, Wang G, Bai XF, Tan P, Li ZK, et al. High strength bulk tantalum with novel gradient structure within a particle fabricated by spark plasma sintering. Mater Sci Eng, A 2011;528:8332-6.
    • (2011) Mater Sci Eng, A , vol.528 , pp. 8332-8336
    • Zhang, Y.S.1    Zhang, X.M.2    Wang, G.3    Bai, X.F.4    Tan, P.5    Li, Z.K.6
  • 79
    • 50349089747 scopus 로고    scopus 로고
    • Interface interactions between porous titanium/tantalum coatings, produced by selective laser melting (SLM), on a cobalt-chromium alloy
    • Fox P, Pogson S, Sutcliffe CJ, Jones E. Interface interactions between porous titanium/tantalum coatings, produced by selective laser melting (SLM), on a cobalt-chromium alloy. Surf Coat Technol 2008;202:5001-7.
    • (2008) Surf Coat Technol , vol.202 , pp. 5001-5007
    • Fox, P.1    Pogson, S.2    Sutcliffe, C.J.3    Jones, E.4
  • 80
    • 84878620720 scopus 로고    scopus 로고
    • Strong morphological and crystallographic texture and resulting yield strength anisotropy in selective laser melted tantalum
    • Thijs L, Montero Sistiaga ML, Wauthle R, Xie Q, Kruth J-P, Van Humbeeck J. Strong morphological and crystallographic texture and resulting yield strength anisotropy in selective laser melted tantalum. Acta Mater 2013;61:4657-68.
    • (2013) Acta Mater , vol.61 , pp. 4657-4668
    • Thijs, L.1    Montero Sistiaga, M.L.2    Wauthle, R.3    Xie, Q.4    Kruth, J.-P.5    Van Humbeeck, J.6
  • 81
    • 36248993514 scopus 로고    scopus 로고
    • Consolidation phenomena in laser and powder-bed based layered manufacturing
    • Kruth JP, Levy G, Klocke F, Childs THC. Consolidation phenomena in laser and powder-bed based layered manufacturing. CIRP Ann Manuf Technol 2007;56:730-59.
    • (2007) CIRP Ann Manuf Technol , vol.56 , pp. 730-759
    • Kruth, J.P.1    Levy, G.2    Klocke, F.3    Childs, T.H.C.4
  • 83
    • 84875209842 scopus 로고    scopus 로고
    • Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects
    • Van der Stok J, Van der Jagt OP, Amin Yavari S, DeHaas MF, Waarsing JH, Jahr H, et al. Selective laser melting-produced porous titanium scaffolds regenerate bone in critical size cortical bone defects. J Orthop Res 2013;31:792-9.
    • (2013) J Orthop Res , vol.31 , pp. 792-799
    • Van Der Stok, J.1    Van Der Jagt, O.P.2    Amin Yavari, S.3    DeHaas, M.F.4    Waarsing, J.H.5    Jahr, H.6
  • 84
    • 84889801229 scopus 로고    scopus 로고
    • Enhanced bone regeneration of cortical segmental bone defects using porous titanium scaffolds incorporated with colloidal gelatin gels for time- and dose-controlled delivery of dual growth factors
    • van der stok J, Wang H, Amin Yavari S, Siebelt M, Sandker M, Waarsing JH, et al. Enhanced bone regeneration of cortical segmental bone defects using porous titanium scaffolds incorporated with colloidal gelatin gels for time- and dose-controlled delivery of dual growth factors. Tissue Eng A 2013;19:2605-14.
    • (2013) Tissue Eng A , vol.19 , pp. 2605-2614
    • Van Der Stok, J.1    Wang, H.2    Amin Yavari, S.3    Siebelt, M.4    Sandker, M.5    Waarsing, J.H.6
  • 85
    • 84875543515 scopus 로고    scopus 로고
    • Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing
    • Campoli G, Borleffs MS, Amin Yavari S, Wauthle R, Weinans H, Zadpoor AA. Mechanical properties of open-cell metallic biomaterials manufactured using additive manufacturing. Mater Des 2013;49:957-65.
    • (2013) Mater des , vol.49 , pp. 957-965
    • Campoli, G.1    Borleffs, M.S.2    Amin Yavari, S.3    Wauthle, R.4    Weinans, H.5    Zadpoor, A.A.6
  • 91
    • 84905266098 scopus 로고    scopus 로고
    • Mechanical analysis of a rodent segmental bone defect model: The effects of internal fixation and implant stiffness on load transfer
    • Amin Yavari S, van der Stok J, Ahmadi SM, Wauthle R, Schrooten J, Weinans H, et al. Mechanical analysis of a rodent segmental bone defect model: the effects of internal fixation and implant stiffness on load transfer. J Biomech 2014;47(11):2700-8. http://dx.doi.org/10.1016/j.jbiomech.2014.05.006.
    • (2014) J Biomech , vol.47 , Issue.11 , pp. 2700-2708
    • Amin Yavari, S.1    Van Der Stok, J.2    Ahmadi, S.M.3    Wauthle, R.4    Schrooten, J.5    Weinans, H.6
  • 93
    • 4444276823 scopus 로고
    • Tantalum - Processing, properties and applications
    • Köck W, Paschen P. Tantalum - processing, properties and applications. JOM 1989;41:33-9.
    • (1989) JOM , vol.41 , pp. 33-39
    • Köck, W.1    Paschen, P.2
  • 95
    • 0033501736 scopus 로고    scopus 로고
    • Mechanisms of fatigue-crack propagation in ductile and brittle solids
    • Ritchie RO. Mechanisms of fatigue-crack propagation in ductile and brittle solids. Int J Fract 1999;100:55-83.
    • (1999) Int J Fract , vol.100 , pp. 55-83
    • Ritchie, R.O.1
  • 96
    • 0022413393 scopus 로고
    • The influence of induced micromovement upon the healing of experimental tibial fractures
    • Goodship AE, Kenwright J. The influence of induced micromovement upon the healing of experimental tibial fractures. J Bone Joint Surg Br 1985;67:650-5.
    • (1985) J Bone Joint Surg Br , vol.67 , pp. 650-655
    • Goodship, A.E.1    Kenwright, J.2
  • 99
    • 0034621881 scopus 로고    scopus 로고
    • Effects of mechanical forces on maintenance and adaptation of form in trabecular bone
    • Huiskes R, Ruimerman R, van Lenthe GH, Janssen JD. Effects of mechanical forces on maintenance and adaptation of form in trabecular bone. Nature 2000;405:704-6.
    • (2000) Nature , vol.405 , pp. 704-706
    • Huiskes, R.1    Ruimerman, R.2    Van Lenthe, G.H.3    Janssen, J.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.