메뉴 건너뛰기




Volumn 1374, Issue , 2014, Pages 40-49

High throughput quantification of prohibited substances in plasma using thin film solid phase microextraction

Author keywords

High throughput; Plasma; Prohibited substances; Sample preparation; Solid phase microextraction; Thin film

Indexed keywords

AUTOMATION; BIOCOMPATIBILITY; FILM PREPARATION; PLASMAS; SAMPLING; THIN FILMS;

EID: 84916242646     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2014.11.047     Document Type: Article
Times cited : (77)

References (41)
  • 1
    • 84916221927 scopus 로고    scopus 로고
    • Retrieved from (19.07.14)
    • World Antidoping Agency (WADA) Prohibited List 2014, Retrieved from: http://www.wada-ama.org/Documents/World_Anti-Doping_Program/WADP-Prohibited-list/2014/WADA-prohibited-list-2014-EN.pdf (19.07.14).
    • (2014) Prohibited List
  • 2
    • 84916227252 scopus 로고    scopus 로고
    • Retrieved from (19.07.14)
    • World Antidoping Agency (WADA) Minimum Required Performance Levels 2014, Retrieved from: http://www.wada-ama.org/Documents/World_Anti-Doping_Program/WADP-IS-Laboratories/Technical_Documents/WADA-TD2014MRPL-v1-Minimum-Required-Performance-Levels-EN.pdf (19.07.14).
    • (2014) Minimum Required Performance Levels
  • 3
    • 84890118884 scopus 로고    scopus 로고
    • Targeting prohibited substances in doping control blood samples by means of chromatographic-mass spectrometric methods
    • Thevis M., Thomas A., Schänzer W. Targeting prohibited substances in doping control blood samples by means of chromatographic-mass spectrometric methods. Anal. Bioanal. Chem. 2013, 405:9655-9667.
    • (2013) Anal. Bioanal. Chem. , vol.405 , pp. 9655-9667
    • Thevis, M.1    Thomas, A.2    Schänzer, W.3
  • 4
    • 84861231627 scopus 로고    scopus 로고
    • Sensitive determination of prohibited drugs in dried blood spots (DBS) for doping controls by means of a benchtop quadrupole/Orbitrap mass spectrometer
    • Thomas A., Geyer H., Schänzer W., Crone C., Kellmann M., Moehring T., Thevis M. Sensitive determination of prohibited drugs in dried blood spots (DBS) for doping controls by means of a benchtop quadrupole/Orbitrap mass spectrometer. Anal. Bioanal. Chem. 2012, 403:1279-1289.
    • (2012) Anal. Bioanal. Chem. , vol.403 , pp. 1279-1289
    • Thomas, A.1    Geyer, H.2    Schänzer, W.3    Crone, C.4    Kellmann, M.5    Moehring, T.6    Thevis, M.7
  • 6
    • 84864462465 scopus 로고    scopus 로고
    • Challenges and perspectives in anti-doping testing
    • Schamasch P., Rabin O. Challenges and perspectives in anti-doping testing. Bioanalysis 2012, 4:1691-1701.
    • (2012) Bioanalysis , vol.4 , pp. 1691-1701
    • Schamasch, P.1    Rabin, O.2
  • 7
    • 84877106925 scopus 로고    scopus 로고
    • Ultrahigh pressure liquid chromatography-(tandem) mass spectrometry in human sports drug testing: possibilities and limitations
    • Thevis M., Thomas A., Pop V., Schänzer W. Ultrahigh pressure liquid chromatography-(tandem) mass spectrometry in human sports drug testing: possibilities and limitations. J. Chromatogr. A 2013, 1292:38-50.
    • (2013) J. Chromatogr. A , vol.1292 , pp. 38-50
    • Thevis, M.1    Thomas, A.2    Pop, V.3    Schänzer, W.4
  • 8
    • 80052559344 scopus 로고    scopus 로고
    • Direct quantification of cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry
    • Schwope D.M., Scheidweiler K.B., Huestis M.A. Direct quantification of cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography-tandem mass spectrometry. Anal. Bioanal. Chem. 2011, 401:1273-1283.
    • (2011) Anal. Bioanal. Chem. , vol.401 , pp. 1273-1283
    • Schwope, D.M.1    Scheidweiler, K.B.2    Huestis, M.A.3
  • 9
    • 84879667267 scopus 로고    scopus 로고
    • Screening for illicit and medicinal drugs in whole blood using fully automated SPE and ultra-high-performance liquid chromatography with TOF-MS with data-independent acquisition
    • Pedersen A.J., Dalsgaard P.W., Rode A.J., Rasmussen B.S., Müller I.B., Johansen S.S., Linnet K. Screening for illicit and medicinal drugs in whole blood using fully automated SPE and ultra-high-performance liquid chromatography with TOF-MS with data-independent acquisition. J. Sep. Sci. 2013, 36:2081-2089.
    • (2013) J. Sep. Sci. , vol.36 , pp. 2081-2089
    • Pedersen, A.J.1    Dalsgaard, P.W.2    Rode, A.J.3    Rasmussen, B.S.4    Müller, I.B.5    Johansen, S.S.6    Linnet, K.7
  • 10
    • 41649097412 scopus 로고    scopus 로고
    • Concentrations of cocaine and its major metabolite benzoylecgonine in blood samples from apprehended drivers in Sweden
    • Jones A.W., Holmgren A., Kugelberg F.C. Concentrations of cocaine and its major metabolite benzoylecgonine in blood samples from apprehended drivers in Sweden. Forensic Sci. Int. 2008, 177:133-139.
    • (2008) Forensic Sci. Int. , vol.177 , pp. 133-139
    • Jones, A.W.1    Holmgren, A.2    Kugelberg, F.C.3
  • 11
    • 24044488944 scopus 로고    scopus 로고
    • The quantitative analysis of heroin, methadone and their metabolites and the simultaneous detection of cocaine, acetylcodeine and their metabolites in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry
    • Rook E.J., Hillebrand M.J.X., Rosing H., van Ree J.M., Beijnen J.H. The quantitative analysis of heroin, methadone and their metabolites and the simultaneous detection of cocaine, acetylcodeine and their metabolites in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2005, 824:213-221.
    • (2005) J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. , vol.824 , pp. 213-221
    • Rook, E.J.1    Hillebrand, M.J.X.2    Rosing, H.3    van Ree, J.M.4    Beijnen, J.H.5
  • 13
    • 84880172682 scopus 로고    scopus 로고
    • High resolution accurate mass screening of prohibited substances in equine plasma using liquid chromatography - Orbitrap mass spectrometry
    • Ho E.N.M., Kwok W.H., Wong A.S.Y., Wan T.S.M. High resolution accurate mass screening of prohibited substances in equine plasma using liquid chromatography - Orbitrap mass spectrometry. Drug Test. Anal. 2013, 5:509-528.
    • (2013) Drug Test. Anal. , vol.5 , pp. 509-528
    • Ho, E.N.M.1    Kwok, W.H.2    Wong, A.S.Y.3    Wan, T.S.M.4
  • 14
    • 84874952542 scopus 로고    scopus 로고
    • Ultra high performance liquid chromatography/tandem mass spectrometry based identification of steroid esters in serum and plasma: an efficient strategy to detect natural steroids abuse in breeding and racing animals
    • Kaabia Z., Dervilly-Pinel G., Hanganu F., Cesbron N., Bichon E., Popot M.A., Bonnaire Y., Le Bizec B. Ultra high performance liquid chromatography/tandem mass spectrometry based identification of steroid esters in serum and plasma: an efficient strategy to detect natural steroids abuse in breeding and racing animals. J. Chromatogr. A 2013, 1284:126-140.
    • (2013) J. Chromatogr. A , vol.1284 , pp. 126-140
    • Kaabia, Z.1    Dervilly-Pinel, G.2    Hanganu, F.3    Cesbron, N.4    Bichon, E.5    Popot, M.A.6    Bonnaire, Y.7    Le Bizec, B.8
  • 16
    • 78751687715 scopus 로고    scopus 로고
    • Detection and confirmation of 60 anabolic and androgenic steroids in equine plasma by liquid chromatography-tandem mass spectrometry with instant library searching
    • Liu Y., Uboh C.E., Soma L.R., Li X., Guan F., You Y., Rudy J.A., Chen J.-W. Detection and confirmation of 60 anabolic and androgenic steroids in equine plasma by liquid chromatography-tandem mass spectrometry with instant library searching. Drug Test. Anal. 2011, 3:54-67.
    • (2011) Drug Test. Anal. , vol.3 , pp. 54-67
    • Liu, Y.1    Uboh, C.E.2    Soma, L.R.3    Li, X.4    Guan, F.5    You, Y.6    Rudy, J.A.7    Chen, J.-W.8
  • 17
    • 80052329343 scopus 로고    scopus 로고
    • Efficient use of retention time for the analysis of 302 drugs in equine plasma by liquid chromatography-MS/MS with scheduled multiple reaction monitoring and instant library searching for doping control
    • Liu Y., Uboh C.E., Soma L.R., Li X., Guan F., You Y., Chen J.-W. Efficient use of retention time for the analysis of 302 drugs in equine plasma by liquid chromatography-MS/MS with scheduled multiple reaction monitoring and instant library searching for doping control. Anal. Chem. 2011, 83:6834-6841.
    • (2011) Anal. Chem. , vol.83 , pp. 6834-6841
    • Liu, Y.1    Uboh, C.E.2    Soma, L.R.3    Li, X.4    Guan, F.5    You, Y.6    Chen, J.-W.7
  • 18
    • 77951976604 scopus 로고    scopus 로고
    • Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry
    • Kwok W.H., Leung D.K.K., Leung G.N.W., Wan T.S.M., Wong C.H.F., Wong J.K.Y. Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography-tandem mass spectrometry. J. Chromatogr. A 2010, 1217:3289-3296.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 3289-3296
    • Kwok, W.H.1    Leung, D.K.K.2    Leung, G.N.W.3    Wan, T.S.M.4    Wong, C.H.F.5    Wong, J.K.Y.6
  • 19
    • 84876973252 scopus 로고    scopus 로고
    • Ultra high performance liquid chromatography tandem mass spectrometry determination and profiling of prohibited steroids in human biological matrices
    • Gosetti F., Mazzucco E., Gennaro M.C., Marengo E. Ultra high performance liquid chromatography tandem mass spectrometry determination and profiling of prohibited steroids in human biological matrices. J. Chromatogr. A 2013, 927:22-36.
    • (2013) J. Chromatogr. A , vol.927 , pp. 22-36
    • Gosetti, F.1    Mazzucco, E.2    Gennaro, M.C.3    Marengo, E.4
  • 20
    • 84889569083 scopus 로고    scopus 로고
    • The challenges of LC-MS/MS ana lysis of opiates and opioids in urine
    • French D. The challenges of LC-MS/MS ana lysis of opiates and opioids in urine. Bioanalysis 2013, 5:2803-2820.
    • (2013) Bioanalysis , vol.5 , pp. 2803-2820
    • French, D.1
  • 22
    • 84891925532 scopus 로고    scopus 로고
    • Introduction of solid-phase microextraction as a high-throughput sample preparation tool in laboratory analysis of prohibited substances
    • Boyaci E., Gorynski K., Rodriguez-Lafuente A., Bojko B., Pawliszyn J. Introduction of solid-phase microextraction as a high-throughput sample preparation tool in laboratory analysis of prohibited substances. Anal. Chim. Acta 2014, 809:69-81.
    • (2014) Anal. Chim. Acta , vol.809 , pp. 69-81
    • Boyaci, E.1    Gorynski, K.2    Rodriguez-Lafuente, A.3    Bojko, B.4    Pawliszyn, J.5
  • 23
    • 79960987740 scopus 로고    scopus 로고
    • Optimization of the coating procedure for a high-throughput 96-blade solid phase microextraction system coupled with LC-MS/MS for analysis of complex samples
    • Mirnaghi F.S., Chen Y., Sidisky L.M., Pawliszyn J. Optimization of the coating procedure for a high-throughput 96-blade solid phase microextraction system coupled with LC-MS/MS for analysis of complex samples. Anal. Chem. 2011, 83:6018-6025.
    • (2011) Anal. Chem. , vol.83 , pp. 6018-6025
    • Mirnaghi, F.S.1    Chen, Y.2    Sidisky, L.M.3    Pawliszyn, J.4
  • 24
    • 75149125610 scopus 로고    scopus 로고
    • Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand-receptor binding studies
    • Vuckovic D., Cudjoe E., Musteata F.M., Pawliszyn J. Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand-receptor binding studies. Nat. Protoc. 2010, 5:140-161.
    • (2010) Nat. Protoc. , vol.5 , pp. 140-161
    • Vuckovic, D.1    Cudjoe, E.2    Musteata, F.M.3    Pawliszyn, J.4
  • 25
    • 51949101476 scopus 로고    scopus 로고
    • Automation of solid-phase microextraction in high-throughput format and applications to drug analysis
    • Vuckovic D., Cudjoe E., Hein D., Pawliszyn J. Automation of solid-phase microextraction in high-throughput format and applications to drug analysis. Anal. Chem. 2010, 80:6870-6880.
    • (2010) Anal. Chem. , vol.80 , pp. 6870-6880
    • Vuckovic, D.1    Cudjoe, E.2    Hein, D.3    Pawliszyn, J.4
  • 27
    • 84890335615 scopus 로고    scopus 로고
    • The bioanalytical challenge of determining unbound concentration and protein binding for drugs
    • Nilsson L.B. The bioanalytical challenge of determining unbound concentration and protein binding for drugs. Bioanalysis 2013, 5:3033-3050.
    • (2013) Bioanalysis , vol.5 , pp. 3033-3050
    • Nilsson, L.B.1
  • 28
    • 0034308903 scopus 로고    scopus 로고
    • Evaluation of solid-phase microextraction for the study of protein binding in human plasma samples
    • Abdel-Rehim M., Carlsson G., Bielenstein M., Arvidsson T., Blomberg L.G. Evaluation of solid-phase microextraction for the study of protein binding in human plasma samples. J. Chromatogr. Sci. 2000, 38:458-464.
    • (2000) J. Chromatogr. Sci. , vol.38 , pp. 458-464
    • Abdel-Rehim, M.1    Carlsson, G.2    Bielenstein, M.3    Arvidsson, T.4    Blomberg, L.G.5
  • 29
    • 0142217486 scopus 로고    scopus 로고
    • Shift in pH of biological fluids during storage and processing: effect on bioanalysis
    • Fura A., Harper T.W., Zhang H., Fung L., Shyu W.C. Shift in pH of biological fluids during storage and processing: effect on bioanalysis. J. Pharm. Biomed. Anal. 2003, 32:513-522.
    • (2003) J. Pharm. Biomed. Anal. , vol.32 , pp. 513-522
    • Fura, A.1    Harper, T.W.2    Zhang, H.3    Fung, L.4    Shyu, W.C.5
  • 30
    • 0034953125 scopus 로고    scopus 로고
    • Effect of temperature on serum protein binding characteristics of phenytoin in monotherapy paediatric patients with epilepsy
    • Kodama H., Kodama Y., Itokazu N., Shinozawa S., Kanemaru R., Sugimoto T. Effect of temperature on serum protein binding characteristics of phenytoin in monotherapy paediatric patients with epilepsy. J. Clin. Pharm. Ther. 2001, 26:175-179.
    • (2001) J. Clin. Pharm. Ther. , vol.26 , pp. 175-179
    • Kodama, H.1    Kodama, Y.2    Itokazu, N.3    Shinozawa, S.4    Kanemaru, R.5    Sugimoto, T.6
  • 31
    • 34249681467 scopus 로고    scopus 로고
    • Effect of temperature on protein binding of cortisol
    • Vogeser M., Briegel J. Effect of temperature on protein binding of cortisol. Clin. Biochem. 2007, 40:724-727.
    • (2007) Clin. Biochem. , vol.40 , pp. 724-727
    • Vogeser, M.1    Briegel, J.2
  • 32
    • 34249901783 scopus 로고    scopus 로고
    • A pharmacokinetic/pharmacodynamic approach to predict total prednisolone concentrations in human plasma
    • Xu J., Winkler J., Derendorf H. A pharmacokinetic/pharmacodynamic approach to predict total prednisolone concentrations in human plasma. J. Pharmacokinet. Pharmacodyn. 2007, 34:355-372.
    • (2007) J. Pharmacokinet. Pharmacodyn. , vol.34 , pp. 355-372
    • Xu, J.1    Winkler, J.2    Derendorf, H.3
  • 33
    • 0020039002 scopus 로고
    • Prednisolone binding to albumin and transcortin in the presence of cortisol
    • Rocci M.L., D'Ambrosio R., Johnson N.F., Jusko W.J. Prednisolone binding to albumin and transcortin in the presence of cortisol. Biochem. Pharmacol. 1982, 31:289-292.
    • (1982) Biochem. Pharmacol. , vol.31 , pp. 289-292
    • Rocci, M.L.1    D'Ambrosio, R.2    Johnson, N.F.3    Jusko, W.J.4
  • 34
    • 84906571484 scopus 로고    scopus 로고
    • Retrieved from (06.07.14)
    • ChemSpider Search and Share Chemistry 2014, Retrieved from: http://www.chemspider.com/?gclid=CLWVmdX0sL8CFa4WMgod3AcAlA (06.07.14).
    • (2014) Search and Share Chemistry
  • 35
    • 84916205533 scopus 로고    scopus 로고
    • Retrieved from: (06.07.14)
    • DrugBank (n.d.), Retrieved from: (06.07.14). http://www.drugbank.ca/.
  • 36
    • 0031830331 scopus 로고    scopus 로고
    • A preliminary study on the distribution of morphine and its glucuronides in the subcompartments of blood
    • Sköpp G., Pötsch L., Ganssmann B., Aderjan R., Mattern R. A preliminary study on the distribution of morphine and its glucuronides in the subcompartments of blood. J. Anal. Toxicol. 1998, 22:261-264.
    • (1998) J. Anal. Toxicol. , vol.22 , pp. 261-264
    • Sköpp, G.1    Pötsch, L.2    Ganssmann, B.3    Aderjan, R.4    Mattern, R.5
  • 37
    • 0037187751 scopus 로고    scopus 로고
    • Partition coefficient, blood to plasma ratio, protein binding and short-term stability of 11-nor-D9-carboxy tetrahydrocannabinol glucuronide
    • Sköpp G., Pötsch L., Mauden M., Richter B. Partition coefficient, blood to plasma ratio, protein binding and short-term stability of 11-nor-D9-carboxy tetrahydrocannabinol glucuronide. Forensic Sci. Int. 2002, 126:17-23.
    • (2002) Forensic Sci. Int. , vol.126 , pp. 17-23
    • Sköpp, G.1    Pötsch, L.2    Mauden, M.3    Richter, B.4
  • 38
    • 0037663202 scopus 로고    scopus 로고
    • Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS
    • Matuszewski B.K., Constanzer M.L., Chavez-Eng C.M. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. Anal. Chem. 2003, 75:3019-3030.
    • (2003) Anal. Chem. , vol.75 , pp. 3019-3030
    • Matuszewski, B.K.1    Constanzer, M.L.2    Chavez-Eng, C.M.3
  • 39
    • 34548729698 scopus 로고    scopus 로고
    • Biocompatible solid-phase microextraction coatings based on polyacrylonitrile and solid-phase extraction phases
    • Musteata M.L., Musteata F.M., Pawliszyn J. Biocompatible solid-phase microextraction coatings based on polyacrylonitrile and solid-phase extraction phases. Anal. Chem. 2007, 79:6903-6911.
    • (2007) Anal. Chem. , vol.79 , pp. 6903-6911
    • Musteata, M.L.1    Musteata, F.M.2    Pawliszyn, J.3
  • 41
    • 84885955642 scopus 로고    scopus 로고
    • Microextraction versus exhaustive extraction approaches for simultaneous analysis of compounds in wide range of polarity
    • Mirnaghi F.S., Goryński K., Rodriguez-Lafuente A., Boyaci E., Bojko B., Pawliszyn J. Microextraction versus exhaustive extraction approaches for simultaneous analysis of compounds in wide range of polarity. J. Chromatogr. A 2013, 1316:37-43.
    • (2013) J. Chromatogr. A , vol.1316 , pp. 37-43
    • Mirnaghi, F.S.1    Goryński, K.2    Rodriguez-Lafuente, A.3    Boyaci, E.4    Bojko, B.5    Pawliszyn, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.