메뉴 건너뛰기




Volumn 139, Issue 23, 2014, Pages 6144-6153

Ion collision crosssection measurements in quadrupole ion traps using a time–frequency analysis method

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOTENSIN I; ANGIOTENSIN II; BRADYKININ; UBIQUITIN;

EID: 84908440187     PISSN: 00032654     EISSN: 13645528     Source Type: Journal    
DOI: 10.1039/c4an01216j     Document Type: Article
Times cited : (14)

References (70)
  • 1
    • 0029117357 scopus 로고
    • Special feature: Historical. Collision-induced dissociation: Readings and commentary
    • R. G. Cooks, Special feature: historical. Collision-induced dissociation: readings and commentary J. Mass Spectrom., 1995, 30, 1215-1221.
    • (1995) J. Mass Spectrom. , vol.30 , pp. 1215-1221
    • Cooks, R.G.1
  • 2
    • 37249068466 scopus 로고    scopus 로고
    • Enabling MALDI-FTICR-MS/MS for high-performance proteomics through combination of infrared and collisional activation
    • E. D. Dodds, J. B. German, C. B. Lebrilla, Enabling MALDI-FTICR-MS/MS for high-performance proteomics through combination of infrared and collisional activation Anal. Chem., 2007, 79, 9547-9556.
    • (2007) Anal. Chem. , vol.79 , pp. 9547-9556
    • Dodds, E.D.1    German, J.B.2    Lebrilla, C.B.3
  • 9
    • 80051552668 scopus 로고    scopus 로고
    • Top-down high-resolution electron capture dissociation mass spectrometry for comprehensive characterization of post-translational modifications in Rhesus monkey cardiac troponin I
    • F. M. Xu, Q. G. Xu, X. T. Dong, M. Guy, H. Guner, T. A. Hacker, Y. Ge, Top-down high-resolution electron capture dissociation mass spectrometry for comprehensive characterization of post-translational modifications in Rhesus monkey cardiac troponin I Int. J. Mass Spectrom., 2011, 305, 95-102.
    • (2011) Int. J. Mass Spectrom. , vol.305 , pp. 95-102
    • Xu, F.M.1    Xu, Q.G.2    Dong, X.T.3    Guy, M.4    Guner, H.5    Hacker, T.A.6    Ge, Y.7
  • 10
    • 33750610338 scopus 로고    scopus 로고
    • Characterization of neurohistone variants and post-translational modifications by electron capture dissociation mass spectrometry
    • B. A. Garcia, N. Siuti, C. E. Thomas, C. A. Mizzen, N. L. Kelleher, Characterization of neurohistone variants and post-translational modifications by electron capture dissociation mass spectrometry Int. J. Mass Spectrom., 2007, 259, 184-196.
    • (2007) Int. J. Mass Spectrom. , vol.259 , pp. 184-196
    • Garcia, B.A.1    Siuti, N.2    Thomas, C.E.3    Mizzen, C.A.4    Kelleher, N.L.5
  • 11
    • 84879459486 scopus 로고    scopus 로고
    • IMSPeptider: A computational peptide collision cross-section area calculator based on a novel molecular dynamics simulation protocol
    • R. V. de Carvalho, D. Lopez-Ferrer, K. S. Guimaraes, R. D. Lins, IMSPeptider: a computational peptide collision cross-section area calculator based on a novel molecular dynamics simulation protocol J. Comput. Chem., 2013, 34, 1707-1718.
    • (2013) J. Comput. Chem. , vol.34 , pp. 1707-1718
    • De Carvalho, R.V.1    Lopez-Ferrer, D.2    Guimaraes, K.S.3    Lins, R.D.4
  • 13
    • 84879071414 scopus 로고    scopus 로고
    • Ion Mobility Spectrometry-Mass Spectrometry Analysis for the Site of
    • A. Shimizu, M. Chiba, Ion Mobility Spectrometry-Mass Spectrometry Analysis for the Site of Aromatic Hydroxylation Drug Metab. Dispos., 2013, 41, 1295-1299.
    • (2013) Aromatic Hydroxylation Drug Metab. Dispos , vol.41 , pp. 1295-1299
    • Shimizu, A.1    Chiba, M.2
  • 15
    • 65049088697 scopus 로고    scopus 로고
    • Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples
    • L. Fenn, M. Kliman, A. Mahsut, S. Zhao, J. McLean, Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples Anal. Bioanal. Chem., 2009, 394, 235-244.
    • (2009) Anal. Bioanal. Chem. , vol.394 , pp. 235-244
    • Fenn, L.1    Kliman, M.2    Mahsut, A.3    Zhao, S.4    Mc Lean, J.5
  • 16
    • 78349306915 scopus 로고    scopus 로고
    • A study of ion-neutral collision cross-section values for low charge states of peptides, proteins, and peptide/protein complexes
    • F. A. Fernandez-Lima, R. C. Blase, D. H. Russell, A study of ion-neutral collision cross-section values for low charge states of peptides, proteins, and peptide/protein complexes Int. J. Mass Spectrom., 2010, 298, 111-118.
    • (2010) Int. J. Mass Spectrom. , vol.298 , pp. 111-118
    • Fernandez-Lima, F.A.1    Blase, R.C.2    Russell, D.H.3
  • 17
    • 84879492455 scopus 로고    scopus 로고
    • A Database of Alkaline-Earth-Coordinated Peptide Cross Sections: Insight into General Aspects of Structure
    • J. Dilger, S. Valentine, M. Glover, D. Clemmer, A Database of Alkaline-Earth-Coordinated Peptide Cross Sections: Insight into General Aspects of Structure J. Am. Soc. Mass Spectrom., 2013, 24, 768-779.
    • (2013) J. Am. Soc. Mass Spectrom. , vol.24 , pp. 768-779
    • Dilger, J.1    Valentine, S.2    Glover, M.3    Clemmer, D.4
  • 18
    • 0030905633 scopus 로고    scopus 로고
    • Ion mobility measurements and their applications to clusters and biomolecules
    • D. E. Clemmer, M. F. Jarrold, Ion mobility measurements and their applications to clusters and biomolecules J. Mass Spectrom., 1997, 32, 577-592.
    • (1997) J. Mass Spectrom. , vol.32 , pp. 577-592
    • Clemmer, D.E.1    Jarrold, M.F.2
  • 20
    • 8444223860 scopus 로고    scopus 로고
    • High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
    • R. Guevremont, High-field asymmetric waveform ion mobility spectrometry: a new tool for mass spectrometry J. Chromatogr. A, 2004, 1058, 3-19.
    • (2004) J. Chromatogr. A , vol.1058 , pp. 3-19
    • Guevremont, R.1
  • 21
    • 58149139271 scopus 로고    scopus 로고
    • Fundamentals of Traveling Wave Ion Mobility Spectrometry
    • A. A. Shvartsburg, R. D. Smith, Fundamentals of Traveling Wave Ion Mobility Spectrometry Anal. Chem., 2008, 80, 9689-9699.
    • (2008) Anal. Chem , vol.80 , pp. 9689-9699
    • Shvartsburg, A.A.1    Smith, R.D.2
  • 23
    • 0036199431 scopus 로고    scopus 로고
    • A new linear ion trap mass spectrometer Rapid Commun
    • J. W. Hager, A new linear ion trap mass spectrometer Rapid Commun. Mass Spectrom., 2002, 16, 512-526.
    • (2002) Mass Spectrom. , vol.16 , pp. 512-526
    • Hager, J.W.1
  • 29
    • 0036772560 scopus 로고    scopus 로고
    • Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap
    • H. Li, W. R. Plass, G. E. Patterson, R. G. Cooks, Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap J. Mass Spectrom., 2002, 37, 1051-1058.
    • (2002) J. Mass Spectrom. , vol.37 , pp. 1051-1058
    • Li, H.1    Plass, W.R.2    Patterson, G.E.3    Cooks, R.G.4
  • 31
    • 0037212641 scopus 로고    scopus 로고
    • Chemical mass shifts in quadrupole ion traps as analytical characteristics of nitro-aromatic compounds
    • H. Y. Li, Y. N. Peng, W. R. Plass, R. G. Cooks, Chemical mass shifts in quadrupole ion traps as analytical characteristics of nitro-aromatic compounds Int. J. Mass Spectrom., 2003, 222, 481-491.
    • (2003) Int. J. Mass Spectrom. , vol.222 , pp. 481-491
    • Li, H.Y.1    Peng, Y.N.2    Plass, W.R.3    Cooks, R.G.4
  • 32
    • 0035891892 scopus 로고    scopus 로고
    • Design, optimization and initial performance of a toroidal RF ion trap mass spectrometer Int
    • S. A. Lammert, W. R. Plass, C. V. Thompson, M. B. Wise, Design, optimization and initial performance of a toroidal RF ion trap mass spectrometer Int. J. Mass Spectrom., 2001, 212, 25-40.
    • (2001) J. Mass Spectrom. , vol.212 , pp. 25-40
    • Lammert, S.A.1    Plass, W.R.2    Thompson, C.V.3    Wise, M.B.4
  • 34
    • 62149147187 scopus 로고    scopus 로고
    • Characterization of electrode surface roughness and its impact on ion trap mass analysis
    • W. Xu, W. J. Chappell, R. G. Cooks, Z. Ouyang, Characterization of electrode surface roughness and its impact on ion trap mass analysis J. Mass Spectrom., 2009, 44, 353-360.
    • (2009) J. Mass Spectrom. , vol.44 , pp. 353-360
    • Xu, W.1    Chappell, W.J.2    Cooks, R.G.3    Ouyang, Z.4
  • 36
    • 0032232010 scopus 로고    scopus 로고
    • Comparison of equilibrium ion density distribution and trapping force in Penning, Paul, and combined ion traps
    • G. Z. Li, S. H. Guan, A. G. Marshall, Comparison of equilibrium ion density distribution and trapping force in Penning, Paul, and combined ion traps J. Am. Soc. Mass Spectrom., 1998, 9, 473-481.
    • (1998) J. Am. Soc. Mass Spectrom. , vol.9 , pp. 473-481
    • Li, G.Z.1    Guan, S.H.2    Marshall, A.G.3
  • 37
    • 84881108063 scopus 로고    scopus 로고
    • The coupling effects of hexapole and octopole fields in quadrupole ion traps: A theoretical study
    • Y. Z. Wang, Z. J. Huang, Y. Jiang, X. C. Xiong, Y. L. Deng, X. Fang, W. Xu, The coupling effects of hexapole and octopole fields in quadrupole ion traps: a theoretical study J. Mass Spectrom., 2013, 48, 937-944.
    • (2013) J. Mass Spectrom. , vol.48 , pp. 937-944
    • Wang, Y.Z.1    Huang, Z.J.2    Jiang, Y.3    Xiong, X.C.4    Deng, Y.L.5    Fang, X.6    Xu, W.7
  • 42
    • 0032795896 scopus 로고    scopus 로고
    • Differential non-destructive image current detection in a fourier transform quadrupole ion trap
    • E. R. Badman, G. E. Patterson, J. M. Wells, R. E. Santini, R. G. Cooks, Differential non-destructive image current detection in a fourier transform quadrupole ion trap J. Mass Spectrom., 1999, 34, 889-894.
    • (1999) J. Mass Spectrom. , vol.34 , pp. 889-894
    • Badman, E.R.1    Patterson, G.E.2    Wells, J.M.3    Santini, R.E.4    Cooks, R.G.5
  • 45
    • 0002832383 scopus 로고
    • Non-linear resonances in quadrupole mass spectrometers due to imperfect fields I. The quadrupole ion trap
    • P. H. Dawson, N. R. Whetten, Non-linear resonances in quadrupole mass spectrometers due to imperfect fields I. The quadrupole ion trap Int. J. Mass Spectrom. Ion Phys., 1969, 2, 45-59.
    • (1969) Int. J. Mass Spectrom. Ion Phys. , vol.2 , pp. 45-59
    • Dawson, P.H.1    Whetten, N.R.2
  • 46
    • 0141998373 scopus 로고
    • Non-linear resonances in quadrupole mass spectrometers due to imperfect fields: II. The quadrupole mass filter and the monopole mass spectrometer
    • P. H. Dawson, N. R. Whetten, Non-linear resonances in quadrupole mass spectrometers due to imperfect fields: II. The quadrupole mass filter and the monopole mass spectrometer Int. J. Mass Spectrom. Ion Phys., 1969, 3, 1-12.
    • (1969) Int. J. Mass Spectrom. Ion Phys. , vol.3 , pp. 1-12
    • Dawson, P.H.1    Whetten, N.R.2
  • 47
    • 84908439084 scopus 로고    scopus 로고
    • Realistic Modeling of Ion-neutral Collisions in Quadrupole Ion Traps
    • M. He, D. Guo, X. Xiong, X. Fang and W. Xu, Realistic Modeling of Ion-neutral Collisions in Quadrupole Ion Traps, J. Mass Spectrom., 2014 DOI: 10.1002/jms.3501
    • (2014) J. Mass Spectrom.
    • He, M.1    Guo, D.2    Xiong, X.3    Fang, X.4    Xu, W.5
  • 48
    • 70350492887 scopus 로고    scopus 로고
    • Linear quadrupoles in mass spectrometry
    • D. J. Douglas, Linear quadrupoles in mass spectrometry Mass Spectrom. Rev., 2009, 28, 937-960.
    • (2009) Mass Spectrom. Rev , vol.28 , pp. 937-960
    • Douglas, D.J.1
  • 50
    • 80053054267 scopus 로고    scopus 로고
    • Modeling of ion transient response to dipolar AC excitation in a quadrupole ion trap
    • W. Xu, W. J. Chappell, Z. Ouyang, Modeling of ion transient response to dipolar AC excitation in a quadrupole ion trap Int. J. Mass Spectrom., 2011, 308, 49-55.
    • (2011) Int. J. Mass Spectrom. , vol.308 , pp. 49-55
    • Xu, W.1    Chappell, W.J.2    Ouyang, Z.3
  • 52
    • 0001666207 scopus 로고    scopus 로고
    • Effect of ion-neutral collision mechanism on the trapped-ion equation of motion: A new mass spectral line shape for high-mass trapped ions
    • S. Guan, G.-Z. Li, A. G. Marshall, Effect of ion-neutral collision mechanism on the trapped-ion equation of motion: a new mass spectral line shape for high-mass trapped ions Int. J. Mass Spectrom. Ion Phys., 1997, 167, 185-193.
    • (1997) Int. J. Mass Spectrom. Ion Phys. , vol.167 , pp. 185-193
    • Guan, S.1    Li, G.-Z.2    Marshall, A.G.3
  • 53
    • 0000293183 scopus 로고
    • Theory of communication. Part 1: The analysis of information
    • D. Gabor, Theory of communication. Part 1: the analysis of information J. Inst. Electr. Eng., Part 3, 1946, 93, 429-441.
    • (1946) J. Inst. Electr. Eng. , vol.93 , pp. 429-441
    • Gabor, D.1
  • 54
    • 84868235912 scopus 로고    scopus 로고
    • Accelerated Simulation study of space charge effects in quadrupole ion traps using GPU techniques
    • X. Xiong, W. Xu, X. Fang, Y. Deng, Z. Ouyang, Accelerated Simulation study of space charge effects in quadrupole ion traps using GPU techniques J. Am. Soc. Mass Spectrom., 2012, 23, 1799-1807.
    • (2012) J. Am. Soc. Mass Spectrom. , vol.23 , pp. 1799-1807
    • Xiong, X.1    Xu, W.2    Fang, X.3    Deng, Y.4    Ouyang, Z.5
  • 55
    • 80052394230 scopus 로고    scopus 로고
    • DC potentials applied to an end-cap electrode of a 3D ion trap for enhanced MSn functionality
    • B. M. Prentice, W. Xu, Z. Ouyang, S. A. McLuckey, DC potentials applied to an end-cap electrode of a 3D ion trap for enhanced MSn functionality Int. J. Mass Spectrom., 2011, 306, 114-122.
    • (2011) Int. J. Mass Spectrom. , vol.306 , pp. 114-122
    • Prentice, B.M.1    Xu, W.2    Ouyang, Z.3    Mc Luckey, S.A.4
  • 57
  • 63
    • 0029841917 scopus 로고    scopus 로고
    • Gas-phase conformation of biological molecules: Bradykinin
    • T. Wyttenbach, G. vonHelden, M. T. Bowers, Gas-phase conformation of biological molecules: Bradykinin J. Am. Chem. Soc., 1996, 118, 8355-8364.
    • (1996) J. Am. Chem. Soc. , vol.118 , pp. 8355-8364
    • Wyttenbach, T.1    Vonhelden, G.2    Bowers, M.T.3
  • 65
    • 84904287343 scopus 로고    scopus 로고
    • Characterization of geometry deviation effects on ion trap mass analysis: A comparison study
    • Y. Wang, X. Zhang, Y. Feng, R. Shao, X. Xiong, X. Fang, Y. Deng, W. Xu, Characterization of geometry deviation effects on ion trap mass analysis: a comparison study Int. J. Mass Spectrom., 2014, 370, 125-131.
    • (2014) Int. J. Mass Spectrom. , vol.370 , pp. 125-131
    • Wang, Y.1    Zhang, X.2    Feng, Y.3    Shao, R.4    Xiong, X.5    Fang, X.6    Deng, Y.7    Xu, W.8
  • 66
    • 84904040629 scopus 로고    scopus 로고
    • Least-Squares Fitting of Time-Domain Signals for Fourier Transform Mass Spectrometry
    • T. Aushev, A. N. Kozhinov, Y. O. Tsybin, Least-Squares Fitting of Time-Domain Signals for Fourier Transform Mass Spectrometry J. Am. Soc. Mass Spectrom., 2014, 25, 1263-1273.
    • (2014) J. Am. Soc. Mass Spectrom. , vol.25 , pp. 1263-1273
    • Aushev, T.1    Kozhinov, A.N.2    Tsybin, Y.O.3
  • 67
    • 84868217406 scopus 로고    scopus 로고
    • Wavelet-Based Method for Time-Domain Noise Analysis and Reduction in a Frequency-Scan Ion Trap Mass Spectrometer
    • S. W. Chou, G. R. Shiu, H. C. Chang, W. P. Peng, Wavelet-Based Method for Time-Domain Noise Analysis and Reduction in a Frequency-Scan Ion Trap Mass Spectrometer J. Am. Soc. Mass Spectrom., 2012, 23, 1855-1864.
    • (2012) J. Am. Soc. Mass Spectrom. , vol.23 , pp. 1855-1864
    • Chou, S.W.1    Shiu, G.R.2    Chang, H.C.3    Peng, W.P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.