메뉴 건너뛰기




Volumn 165, Issue , 2005, Pages 1-346

Quadrupole Ion Trap Mass Spectrometry: Second Edition

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL LABORATORIES; GAS CHROMATOGRAPHY; LIQUID CHROMATOGRAPHY; MASS SPECTROMETERS; MASS SPECTROMETRY; SENSITIVITY ANALYSIS; STUDENTS;

EID: 84949508848     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1002/0471717983     Document Type: Book
Times cited : (251)

References (603)
  • 1
    • 0038166642 scopus 로고
    • Apparatus for separating charged particles of different specific charges
    • W. Paul, H. Steinwedel, Apparatus for separating charged particles of different specific charges, German Patent 944,900 (1956); U.S. Patent 2,939,952 (1960).
    • (1960)
    • Paul, W.1    Steinwedel, H.2
  • 2
    • 84949495814 scopus 로고
    • University of California Radiation Laboratory Report (S. Shewchuck) UCRL 2209, Berkeley, CA
    • R. F. Post, L. Heinrich, University of California Radiation Laboratory Report (S. Shewchuck) UCRL 2209, Berkeley, CA (1953).
    • (1953)
    • Post, R.F.1    Heinrich, L.2
  • 3
    • 84949525317 scopus 로고
    • University of California Radiation Laboratory Report UCRL 4146, Berkeley, CA
    • M. L. Good, University of California Radiation Laboratory Report UCRL 4146, Berkeley, CA (1953).
    • (1953)
    • Good, M.L.1
  • 4
    • 0000775703 scopus 로고
    • The strong-focusing synchrotron; a new high energy accelerator
    • E. D. Courant, M. S. Livingston, H. S. Snyder, The strong-focusing synchrotron; a new high energy accelerator, Phys. Rev. 88 (1952) 1190-1196.
    • (1952) Phys. Rev. , vol.88 , pp. 1190-1196
    • Courant, E.D.1    Livingston, M.S.2    Snyder, H.S.3
  • 5
    • 33646876482 scopus 로고
    • Quadrupoles, monopoles and ion traps
    • P. H. Dawson, N. R. Whetten, Quadrupoles, monopoles and ion traps. Res. Dev. 19(2) (1969) 46-50.
    • (1969) Res. Dev. , vol.19 , Issue.2 , pp. 46-50
    • Dawson, P.H.1    Whetten, N.R.2
  • 6
    • 84885653762 scopus 로고
    • A new mass spectrometer without a magnetic field
    • W. Paul, H. Steinwedel, A new mass spectrometer without a magnetic field, Z. Naturforsch. 8a (1953) 448-450.
    • (1953) Z. Naturforsch. , vol.8 a , pp. 448-450
    • Paul, W.1    Steinwedel, H.2
  • 8
    • 0014973284 scopus 로고
    • Operating parameters of a quadrupole in a grounded cylindrical housing
    • D. R. Denison, Operating parameters of a quadrupole in a grounded cylindrical housing, J. Vac. Sci. Technol. 8 (1971) 266-269.
    • (1971) J. Vac. Sci. Technol. , vol.8 , pp. 266-269
    • Denison, D.R.1
  • 10
    • 0003843122 scopus 로고
    • Elsevier, Amsterdam, Reprinted as an American Vacuum Society classic by the American Institute of Physics (ISBN 1563964554)
    • P. H. Dawson (Ed.), Quadrupole Mass Spectrometry and Its Applications, Elsevier, Amsterdam, 1976. Reprinted as an American Vacuum Society classic by the American Institute of Physics (ISBN 1563964554).
    • (1976) Quadrupole Mass Spectrometry and Its Applications
    • Dawson, P.H.1
  • 11
    • 33646895942 scopus 로고
    • The three-dimensional quadrupole ion trap
    • P. H. Dawson, N. R. Whetten, The three-dimensional quadrupole ion trap, Naturwissenschaften 56 (1969) 109-112.
    • (1969) Naturwissenschaften , vol.56 , pp. 109-112
    • Dawson, P.H.1    Whetten, N.R.2
  • 12
    • 48749143322 scopus 로고
    • The general form of the quadrupole ion trap potential
    • R. D. Knight, The general form of the quadrupole ion trap potential, Int. J. Mass Spectrom. Ion Phys. 51 (1983) 127-131.
    • (1983) Int. J. Mass Spectrom. Ion Phys. , vol.51 , pp. 127-131
    • Knight, R.D.1
  • 13
    • 0001225172 scopus 로고
    • Mémoire sur le mouvement vibratoire d'une membrane de forme elliptique
    • E. Mathieu, Mémoire sur le mouvement vibratoire d'une membrane de forme elliptique, J. Math. Pures Appl. (J. Liouville) 13 (1868) 137.
    • (1868) J. Math. Pures Appl. (J. Liouville) , vol.13 , pp. 137
    • Mathieu, E.1
  • 17
    • 0002115109 scopus 로고
    • Die dreidimensionale Stabilisirung von Ladungsträgern in einem Vierpolfeld
    • E. Fischer, Die dreidimensionale Stabilisirung von Ladungsträgern in einem Vierpolfeld, Z. Phys. 156(l) (1959) 1-26.
    • (1959) Z. Phys. , vol.156 , Issue.L , pp. 1-26
    • Fischer, E.1
  • 18
    • 0000949102 scopus 로고
    • The detection of low partial pressures by means of the ion cage
    • V. von G. Rettinghaus, The detection of low partial pressures by means of the ion cage, Z. Angew. Phys. 22(4) (1967) 321-326.
    • (1967) Z. Angew. Phys. , vol.22 , Issue.4 , pp. 321-326
    • Von, V.1    Rettinghaus, G.2
  • 19
    • 33646864162 scopus 로고
    • Paper DCII. Practical limitations of the electrodynamic ion trap
    • D. C. Burnham, D. Kleppner, Paper DCII. Practical limitations of the electrodynamic ion trap, Bull. Am. Phys. Soc. Ser. II 11 (1968) 70.
    • (1968) Bull. Am. Phys. Soc. Ser. II , vol.11 , pp. 70
    • Burnham, D.C.1    Kleppner, D.2
  • 22
    • 0029402802 scopus 로고
    • Ion remeasurement in the radio frequency quadrupole ion trap
    • D. E. Goeringer, R. I. Crutcher, S. A. McLuckey, Ion remeasurement in the radio frequency quadrupole ion trap, Anal. Chem. 67 (1995) 4164-4169.
    • (1995) Anal. Chem. , vol.67 , pp. 4164-4169
    • Goeringer, D.E.1    Crutcher, R.I.2    McLuckey, S.A.3
  • 24
    • 0001982081 scopus 로고    scopus 로고
    • Characteristics of a broad-band Fourier transform ion trap mass spectrometer
    • M. Nappi, V. Frankevich, M. Soni, R. G. Cooks, Characteristics of a broad-band Fourier transform ion trap mass spectrometer, Int. J. Mass Spectrom. 177 (1998) 91-104.
    • (1998) Int. J. Mass Spectrom. , vol.177 , pp. 91-104
    • Nappi, M.1    Frankevich, V.2    Soni, M.3    Cooks, R.G.4
  • 25
    • 77956859716 scopus 로고
    • Radiofrequency spectroscopy of stored ions. I. Storage
    • H. G. Dehmelt, Radiofrequency spectroscopy of stored ions. I. Storage, Adv. At. Mol. Phys. 3 (1967) 53-72.
    • (1967) Adv. At. Mol. Phys. , vol.3 , pp. 53-72
    • Dehmelt, H.G.1
  • 26
    • 19544389937 scopus 로고
    • Radiofrequency spectroscopy of stored ions. II. Spectroscopy
    • H. G. Dehmelt, Radiofrequency spectroscopy of stored ions. II. Spectroscopy. Adv. At. Mol. Phys. 5 (1969) 109-154.
    • (1969) Adv. At. Mol. Phys. , vol.5 , pp. 109-154
    • Dehmelt, H.G.1
  • 27
    • 0017505516 scopus 로고
    • Spin dependent charge transfer in low-energy collisions between helium ions and cesium atoms
    • H. A. Schuesslcr, Spin dependent charge transfer in low-energy collisions between helium ions and cesium atoms, Metrologia 13 (1977) 109-113.
    • (1977) Metrologia , vol.13 , pp. 109-113
    • Schuesslcr, H.A.1
  • 28
    • 49549138602 scopus 로고
    • Line shifts and widths of axial, cyclotron and G-2 resonances in tailored, stored electron (ion) cloud
    • Erratum, 19 (1976) 251
    • D. J. Wineland, H. Dehmelt, Line shifts and widths of axial, cyclotron and G-2 resonances in tailored, stored electron (ion) cloud, Int. J. Mass Spectrom. Ion Phys. 16 (1975) 338-342; Erratum, 19 (1976) 251.
    • (1975) Int. J. Mass Spectrom. Ion Phys. , vol.16 , pp. 338-342
    • Wineland, D.J.1    Dehmelt, H.2
  • 30
    • 0342684174 scopus 로고
    • Spectroscopy of stored atomic ions
    • R. S. Van Dyck, Jr. and E. N. Fortson (Eds.), World Scientific, Singapore
    • D. J. Wineland,W. M. Itano, J. C. Bergquist, J. J. Bollinger, J. D. Prestage, Spectroscopy of stored atomic ions , in R. S. Van Dyck, Jr. and E. N. Fortson (Eds.), Atomic Physics, Vol. 9, World Scientific, Singapore, 1985, p. 3.
    • (1985) Atomic Physics , vol.9 , pp. 3
    • Wineland, D.J.1    Itano, W.M.2    Bergquist, J.C.3    Bollinger, J.J.4    Prestage, J.D.5
  • 31
    • 33646889162 scopus 로고
    • Selected Publications of the Ion Storage Group of the Time and Frequency Division, National Bureau of Standards, Boulder, CO, June
    • D. J. Wineland, W. M. Itano, J. C. Bergquist, J. J. Bollinger, Trapped Ions and Laser Cooling, Selected Publications of the Ion Storage Group of the Time and Frequency Division, National Bureau of Standards, Boulder, CO, June 1985.
    • (1985) Trapped Ions and Laser Cooling
    • Wineland, D.J.1    Itano, W.M.2    Bergquist, J.C.3    Bollinger, J.J.4
  • 32
    • 1642362401 scopus 로고
    • Stored ion spectroscopy
    • W. Hanic and H. Kleinpoppen (Eds.), Part B, Plenum, New York
    • H. A. Schuessler, Stored ion spectroscopy , in W. Hanic and H. Kleinpoppen (Eds.), Progress in Atomic Spectroscopy, Part B, Plenum, New York, 1979, pp. 999-1029.
    • (1979) Progress in Atomic Spectroscopy , pp. 999-1029
    • Schuessler, H.A.1
  • 35
    • 0002327072 scopus 로고
    • Ion storage in three-dimensional, rotationally symmetric, quadrupole fields. I. Theoretical treatment
    • P. H. Dawson, N. R. Whetten, Ion storage in three-dimensional, rotationally symmetric, quadrupole fields. I. Theoretical treatment, J. Vac. Sci. Technol. 5 (1968) 1-10.
    • (1968) J. Vac. Sci. Technol. , vol.5 , pp. 1-10
    • Dawson, P.H.1    Whetten, N.R.2
  • 36
    • 0002865070 scopus 로고
    • Ion storage in three-dimensional, rotationally symmetric, quadrupole fields. II. A sensitive mass spectrometer
    • P. H. Dawson, N. R. Whetten, Ion storage in three-dimensional, rotationally symmetric, quadrupole fields. II. A sensitive mass spectrometer, J. Vac. Sci. Technol. 5 (1968), 11-18.
    • (1968) J. Vac. Sci. Technol. , vol.5 , pp. 11-18
    • Dawson, P.H.1    Whetten, N.R.2
  • 37
    • 50249189172 scopus 로고
    • Three-dimensional mass spectrometer and gauge
    • P. H. Dawson, N. R. Whetten, Three-dimensional mass spectrometer and gauge, U.S. Patent 3,527,939 (1970).
    • (1970)
    • Dawson, P.H.1    Whetten, N.R.2
  • 42
    • 33646866222 scopus 로고
    • The three-dimensional quadrupole mass spectrometer
    • Ph.D. Thesis, University of Toronto, Institute of Aerospace Studies, Technical Note 172, Toronto, Canada
    • S. Mastoris, The three-dimensional quadrupole mass spectrometer, Ph.D. Thesis, University of Toronto, Institute of Aerospace Studies, Technical Note 172, Toronto, Canada, (1971a).
    • (1971)
    • Mastoris, S.1
  • 43
    • 33646867949 scopus 로고
    • Shape of the mass peak in a three-dimensional quadrupole mass spectrometer
    • E. P. Sheretov, V. A. Zenkin, Shape of the mass peak in a three-dimensional quadrupole mass spectrometer, Sov. Phys. Tech. Phys. 17 (1972) 160-162.
    • (1972) Sov. Phys. Tech. Phys. , vol.17 , pp. 160-162
    • Sheretov, E.P.1    Zenkin, V.A.2
  • 44
    • 0015004474 scopus 로고
    • Three-dimensional quadrupole mass spectrometer with ion storage
    • E. P. Sheretov, V. A. Zenkin, O. I. Boligatov, Three-dimensional quadrupole mass spectrometer with ion storage, Gen. Exp. Tech. 14 (1971) 195-197.
    • (1971) Gen. Exp. Tech. , vol.14 , pp. 195-197
    • Sheretov, E.P.1    Zenkin, V.A.2    Boligatov, O.I.3
  • 45
    • 33646895310 scopus 로고
    • Three-dimensional quadrupole mass spectrometer with sweep of the mass spectrum by variation of the frequency of the supply signal
    • E. P. Sheretov, V. A. Zenkin, V. F. Samodurov, N. D. Veselkin, Three-dimensional quadrupole mass spectrometer with sweep of the mass spectrum by variation of the frequency of the supply signal, Gen. Expt. Tech. 16 (1973) 194-196.
    • (1973) Gen. Expt. Tech. , vol.16 , pp. 194-196
    • Sheretov, E.P.1    Zenkin, V.A.2    Samodurov, V.F.3    Veselkin, N.D.4
  • 47
    • 33646890738 scopus 로고
    • Three-dimensional accumulation quadrupole mass spectrometer
    • E. P. Sheretov, V. A. Zenkin, V. F. Samodurov, Three-dimensional accumulation quadrupole mass spectrometer, Zh. Tekh. Fiz. 43 (1973) 441.
    • (1973) Zh. Tekh. Fiz. , vol.43 , pp. 441
    • Sheretov, E.P.1    Zenkin, V.A.2    Samodurov, V.F.3
  • 48
    • 33646874654 scopus 로고
    • Charged-particle extraction from a three-dimensional quadrupole trap
    • E. P. Sheretov, V. A. Zenkin, G. A. Mogil'chenko, Charged-particle extraction from a three-dimensional quadrupole trap, Sov. Phys. Tech. Phys. 20 (1976) 1398-1400.
    • (1976) Sov. Phys. Tech. Phys. , vol.20 , pp. 1398-1400
    • Sheretov, E.P.1    Zenkin, V.A.2    Mogil'chenko, G.A.3
  • 50
    • 0000328369 scopus 로고
    • Computer simulation of single-ion trajectories in Paul-type ion traps
    • F. A. Londry, R. L. Alfred, R. E. March, Computer simulation of single-ion trajectories in Paul-type ion traps, J. Am. Soc. Mass Spectrom. 4 (1993) 687-705.
    • (1993) J. Am. Soc. Mass Spectrom. , vol.4 , pp. 687-705
    • Londry, F.A.1    Alfred, R.L.2    March, R.E.3
  • 51
    • 0001912777 scopus 로고
    • Multiparticle simulation of ion motion in the ion trap mass spectrometer: Resonant and direct current pulse excitation
    • R. K. Julian, M. Nappi, C. Weil, R. G. Cooks, Multiparticle simulation of ion motion in the ion trap mass spectrometer: Resonant and direct current pulse excitation, J. Am. Soc. Mass Spectrom. 6 (1995) 57-70.
    • (1995) J. Am. Soc. Mass Spectrom. , vol.6 , pp. 57-70
    • Julian, R.K.1    Nappi, M.2    Weil, C.3    Cooks, R.G.4
  • 52
    • 0031954411 scopus 로고    scopus 로고
    • Windows version of the ion trap simulation program ITSIM: A powerful heuristic and predictive tool in ion trap mass spectrometry
    • H. A. Bui, R. G. Cooks, Windows version of the ion trap simulation program ITSIM: A powerful heuristic and predictive tool in ion trap mass spectrometry, J. Mass Spectrom. 33 (1998) 297-304.
    • (1998) J. Mass Spectrom. , vol.33 , pp. 297-304
    • Bui, H.A.1    Cooks, R.G.2
  • 53
    • 0033456288 scopus 로고    scopus 로고
    • Simulation of ion trajectories in a quadrupole ion trap: A comparison of three simulation programs
    • M. W. Forbes, M. Sharifi, T. R. Croley, Z. Lausevic, R. E. March, Simulation of ion trajectories in a quadrupole ion trap: A comparison of three simulation programs, J. Mass Spectrom. 34 (1999) 1219-1239.
    • (1999) J. Mass Spectrom. , vol.34 , pp. 1219-1239
    • Forbes, M.W.1    Sharifi, M.2    Croley, T.R.3    Lausevic, Z.4    March, R.E.5
  • 55
    • 0016214114 scopus 로고
    • Ion storage mass spectrometry:Applications in the study of ionic processes and chemical ionization reactions
    • R. F. Bonner, G. Lawson, J. F. J. Todd, R. E. March, Ion storage mass spectrometry:Applications in the study of ionic processes and chemical ionization reactions, Adv. Mass Spectrom. 6 (1974) 377-384.
    • (1974) Adv. Mass Spectrom. , vol.6 , pp. 377-384
    • Bonner, R.F.1    Lawson, G.2    Todd, J.F.J.3    March, R.E.4
  • 56
    • 0006432244 scopus 로고
    • Theoretical and experimental studies with the quadrupole ion storage trap ('QUISTOR')
    • G. Lawson, J. F. J. Todd, R. F. Bonner, Theoretical and experimental studies with the quadrupole ion storage trap ('QUISTOR'), Dyn. Mass Spectrom. 4 (1975) 39-81.
    • (1975) Dyn. Mass Spectrom. , vol.4 , pp. 39-81
    • Lawson, G.1    Todd, J.F.J.2    Bonner, R.F.3
  • 57
    • 0348140299 scopus 로고
    • Effect of charge exchange reactions on the motion of ions in three-dimensional quadrupole electric fields
    • R. F. Bonner, R. E. March, J. Durup, Effect of charge exchange reactions on the motion of ions in three-dimensional quadrupole electric fields, Int. J. Mass Spectrom. Ion Phys. 22 (1976) 17-34.
    • (1976) Int. J. Mass Spectrom. Ion Phys. , vol.22 , pp. 17-34
    • Bonner, R.F.1    March, R.E.2    Durup, J.3
  • 58
    • 0006468004 scopus 로고
    • The effects of charge exchange collisions on the motion of ions in three-dimensional quadrupole electric fields. Part II. Program improvements and fundamental results
    • R. F. Bonner, R. E. March, The effects of charge exchange collisions on the motion of ions in three-dimensional quadrupole electric fields. Part II. Program improvements and fundamental results, Int. J. Mass Spectrom. Ion Phys. 25 (1977) 411-431.
    • (1977) Int. J. Mass Spectrom. Ion Phys. , vol.25 , pp. 411-431
    • Bonner, R.F.1    March, R.E.2
  • 59
    • 0001546739 scopus 로고
    • The quadrupole ion store (QUISTOR) as a novel source for a mass spectrometer
    • G. Lawson, R. F. Bonner, J. F. J. Todd, The quadrupole ion store (QUISTOR) as a novel source for a mass spectrometer, J. Phys. E. Sci. Instrum. 6 (1973) 357-362.
    • (1973) J. Phys. E. Sci. Instrum. , vol.6 , pp. 357-362
    • Lawson, G.1    Bonner, R.F.2    Todd, J.F.J.3
  • 60
    • 84949496560 scopus 로고
    • Heavy ion plasma confinement in an RF quadrupole trap, NASA Report X-524-71-343, Goddard Space Flight Center, Greenbelt, MD (1971). See also, Characteristics of electron-free plasma confinement in an RF quadrupole field
    • J.-P. Schermann, F. G. Major, Heavy ion plasma confinement in an RF quadrupole trap, NASA Report X-524-71-343, Goddard Space Flight Center, Greenbelt, MD (1971). See also, Characteristics of electron-free plasma confinement in an RF quadrupole field, Appl. Phys. 16 (1978) 225-230.
    • (1978) Appl. Phys. , vol.16 , pp. 225-230
    • Schermann, J.-P.1    Major, F.G.2
  • 63
    • 0001057430 scopus 로고
    • Uber nichtlineare Resonanzen in elektrischen Massenfilter als folge Feldfehlern
    • F. von Busch, W. Paul, Uber nichtlineare Resonanzen in elektrischen Massenfilter als folge Feldfehlern, Z. Phys. 164 (1961) 588-595.
    • (1961) Z. Phys. , vol.164 , pp. 588-595
    • von Busch, F.1    Paul, W.2
  • 64
    • 0011138771 scopus 로고
    • Some causes of poor peak shapes in quadrupole field mass analysers
    • N. R. Whetten, P. H. Dawson, Some causes of poor peak shapes in quadrupole field mass analysers, J. Vac. Sci. Technol. 6 (1969) 100-103.
    • (1969) J. Vac. Sci. Technol. , vol.6 , pp. 100-103
    • Whetten, N.R.1    Dawson, P.H.2
  • 65
    • 84949521655 scopus 로고
    • Some experiments with a three-dimensional quadrupole ion storage device
    • Abstract No. 44, Mass Spectrometry Group Meeting, Bristol
    • G. Lawson, J. F. J. Todd, Some experiments with a three-dimensional quadrupole ion storage device. Abstract No. 44, Mass Spectrometry Group Meeting, Bristol, 1971.
    • (1971)
    • Lawson, G.1    Todd, J.F.J.2
  • 66
    • 37049138527 scopus 로고
    • A low-pressure chemical ionisation source: An application of a novel type of ion storage mass spectrometer
    • J. F. J. Todd, R. F. Bonner, G. Lawson, A low-pressure chemical ionisation source: An application of a novel type of ion storage mass spectrometer, J. Chem. Soc. Chem. Commun. (1972) 1179-1180.
    • (1972) J. Chem. Soc. Chem. Commun. , pp. 1179-1180
    • Todd, J.F.J.1    Bonner, R.F.2    Lawson, G.3
  • 67
    • 0000279590 scopus 로고
    • Quadrupole ion store (QUISTOR). Part I. Ion-molecule reactions in methane, water, and ammonia
    • G. Lawson, R. F. Bonner, R. E. Mather, J. F. J. Todd, R. E. March, Quadrupole ion store (QUISTOR). Part I. Ion-molecule reactions in methane, water, and ammonia, J. Chem. Soc. Faraday Trans. I 72(3) (1976) 545-557.
    • (1976) J. Chem. Soc. Faraday Trans. I , vol.72 , Issue.3 , pp. 545-557
    • Lawson, G.1    Bonner, R.F.2    Mather, R.E.3    Todd, J.F.J.4    March, R.E.5
  • 68
    • 49549163965 scopus 로고
    • Ion-molecule reactions in the carbon dioxide-hydrogen system by ion cyclotron resonance
    • D. L. Smith, J. H. Futrell, Ion-molecule reactions in the carbon dioxide-hydrogen system by ion cyclotron resonance, Int. J. Mass Spectrom. Ion Phys. 10 (1973) 405-418.
    • (1973) Int. J. Mass Spectrom. Ion Phys. , vol.10 , pp. 405-418
    • Smith, D.L.1    Futrell, J.H.2
  • 70
    • 84949489139 scopus 로고
    • Effects of charge-exchange reactions on the motion of ions in three-dimensional quadrupole electric fields. Part II. A two-ion model
    • M. C. Doran, J. E. Fulford, R. J. Hughes, Y. Morita, R. E. March, R. F. Bonner, Effects of charge-exchange reactions on the motion of ions in three-dimensional quadrupole electric fields. Part II. A two-ion model, Int. J. Mass Spectrom. Ion Phys. 33 (1980) 139-158.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.33 , pp. 139-158
    • Doran, M.C.1    Fulford, J.E.2    Hughes, R.J.3    Morita, Y.4    March, R.E.5    Bonner, R.F.6
  • 71
    • 0011278346 scopus 로고
    • The characterization of a quadrupole ion storage mass spectrometer
    • R. F. Mather, R. M. Waldren, J. F. J. Todd, The characterization of a quadrupole ion storage mass spectrometer, Dyn. Mass Spectrom. 5 (1978) 71-85.
    • (1978) Dyn. Mass Spectrom. , vol.5 , pp. 71-85
    • Mather, R.F.1    Waldren, R.M.2    Todd, J.F.J.3
  • 72
    • 0002365743 scopus 로고
    • The quadrupole ion store (QUISTOR). Part IX. Space-charge and ion stability. A. Theoretical background and experimental results
    • J. F. J. Todd, R. M. Waldren, R. E. Mather, The quadrupole ion store (QUISTOR). Part IX. Space-charge and ion stability. A. Theoretical background and experimental results, Int. J. Mass Spectrom. Ion Phys. 34 (1980) 325-349.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.34 , pp. 325-349
    • Todd, J.F.J.1    Waldren, R.M.2    Mather, R.E.3
  • 73
    • 0001131736 scopus 로고
    • Formation et confinement d'ions multichargés dans un champ quadrupolaire a haute fréquence
    • C. Schwebel, P. A. Moller, P.-T. Manh, Formation et confinement d'ions multichargés dans un champ quadrupolaire a haute fréquence, Rev. Phys. Appl. 10 (1975) 227-239.
    • (1975) Rev. Phys. Appl. , vol.10 , pp. 227-239
    • Schwebel, C.1    Moller, P.A.2    Manh, P.-T.3
  • 74
    • 0000527684 scopus 로고
    • A new mode of operation for the three-dimensional quadrupole ion store (QUISTOR): The selective ion reactor
    • J. E. Fulford, R. E. March, A new mode of operation for the three-dimensional quadrupole ion store (QUISTOR): The selective ion reactor, Int. J. Mass Spectrom. Ion Phys. 26 (1978) 155-162.
    • (1978) Int. J. Mass Spectrom. Ion Phys. , vol.26 , pp. 155-162
    • Fulford, J.E.1    March, R.E.2
  • 75
    • 0000255457 scopus 로고
    • Derivations of the field equations and stability parameters for three operating modes of the three-dimensional quadrupole
    • R. F. Bonner, Derivations of the field equations and stability parameters for three operating modes of the three-dimensional quadrupole, Int. J. Mass Spectrom. Ion Phys. 23(4) (1977) 249-257.
    • (1977) Int. J. Mass Spectrom. Ion Phys. , vol.23 , Issue.4 , pp. 249-257
    • Bonner, R.F.1
  • 76
    • 0019033927 scopus 로고
    • Radiofrequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap
    • J. E. Fulford, D.-N. Hoa, R. J. Hughes, R. E. March, R. F. Bonner, G. J. Wong, Radiofrequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap, J. Vac. Sci. Technol. 17(4) (1980) 829-835.
    • (1980) J. Vac. Sci. Technol. , vol.17 , Issue.4 , pp. 829-835
    • Fulford, J.E.1    Hoa, D.-N.2    Hughes, R.J.3    March, R.E.4    Bonner, R.F.5    Wong, G.J.6
  • 77
    • 34250928748 scopus 로고
    • Das elektrische massenfilter als massenspektrometer und isotopentrenner
    • W. Paul, H. P. Reinhard, U. Von Zahn, Das elektrische massenfilter als massenspektrometer und isotopentrenner, Z. Phys. 152 (1958) 143-182.
    • (1958) Z. Phys. , vol.152 , pp. 143-182
    • Paul, W.1    Reinhard, H.P.2    Von Zahn, U.3
  • 78
    • 0001576583 scopus 로고
    • The application of resonant ion ejection to quadrupole ion storage mass spectrometry: A study of ion/molecule reactions in the QUISTOR
    • M. A. Armitage, J. E. Fulford, D.-N. Hoa, R. J. Hughes, R. E. March, The application of resonant ion ejection to quadrupole ion storage mass spectrometry: A study of ion/molecule reactions in the QUISTOR, Can. J. Chem. 57 (1979) 2108-2113.
    • (1979) Can. J. Chem. , vol.57 , pp. 2108-2113
    • Armitage, M.A.1    Fulford, J.E.2    Hoa, D.-N.3    Hughes, R.J.4    March, R.E.5
  • 82
    • 0023386279 scopus 로고
    • Instrumentation, applications and energy disposition in quadrupole ion-trap tandem mass spectrometry
    • J. N. Louris, R. G. Cooks, J. E. P. Syka, P. E. Kelley, G. C. Stafford, J. F. J. Todd, Instrumentation, applications and energy disposition in quadrupole ion-trap tandem mass spectrometry, Anal. Chem. 59 (1987) 1677-1685.
    • (1987) Anal. Chem. , vol.59 , pp. 1677-1685
    • Louris, J.N.1    Cooks, R.G.2    Syka, J.E.P.3    Kelley, P.E.4    Stafford, G.C.5    Todd, J.F.J.6
  • 83
    • 0008096887 scopus 로고
    • Computation of ion trajectories in the monopole mass spectrometer by numerical integration of Mathieu's equation
    • R. F. Lever, Computation of ion trajectories in the monopole mass spectrometer by numerical integration of Mathieu's equation, IBM J. Res. Develop. 10(1) (1966) 26-40.
    • (1966) IBM J. Res. Develop. , vol.10 , Issue.1 , pp. 26-40
    • Lever, R.F.1
  • 85
    • 0007235586 scopus 로고
    • Ion storage in a three-dimensional high frequency, quadrupole field
    • M. Baril, A. Septier, Ion storage in a three-dimensional high frequency, quadrupole field, Rev. Phys. Appl. 9 (1974) 525-531.
    • (1974) Rev. Phys. Appl. , vol.9 , pp. 525-531
    • Baril, M.1    Septier, A.2
  • 86
    • 0002150208 scopus 로고
    • The use of matrix methods and phase space dynamics for the modelling of r.f. quadrupole-type device performance
    • R. M. Waldren, J. F. J. Todd, The use of matrix methods and phase space dynamics for the modelling of r.f. quadrupole-type device performance, Dyn. Mass Spectrom. 5 (1978) 14-40.
    • (1978) Dyn. Mass Spectrom. , vol.5 , pp. 14-40
    • Waldren, R.M.1    Todd, J.F.J.2
  • 87
    • 0007701451 scopus 로고
    • The acceptance of the quadrupole mass filter
    • P. H. Dawson, The acceptance of the quadrupole mass filter, Int. J. Mass Spectrom. Ion Phys. 17 (1975) 423-445.
    • (1975) Int. J. Mass Spectrom. Ion Phys. , vol.17 , pp. 423-445
    • Dawson, P.H.1
  • 88
    • 0019299090 scopus 로고
    • Ion optical properties of quadrupole mass filters
    • P. H. Dawson, Ion optical properties of quadrupole mass filters, Adv. Electron Elect. Phys. 53 (1980) 153-208.
    • (1980) Adv. Electron Elect. Phys. , vol.53 , pp. 153-208
    • Dawson, P.H.1
  • 89
    • 0345006480 scopus 로고
    • Phase space concepts and best operating point for the three-dimensional quadrupole ion trap
    • M. Baril, Phase space concepts and best operating point for the three-dimensional quadrupole ion trap, Dyn. Mass Spectrom. 6 (1981) 33-43.
    • (1981) Dyn. Mass Spectrom. , vol.6 , pp. 33-43
    • Baril, M.1
  • 90
    • 33646859318 scopus 로고
    • Generation and storage of multiplycharged ions within a RF quadrupole trap
    • P. A. Moller, P. T. Manh, C. Schwebel, A. Septier, Generation and storage of multiplycharged ions within a RF quadrupole trap, IEEE Trans. Nucl. Sci. NS-23(2) (1976) 991-993.
    • (1976) IEEE Trans. Nucl. Sci. , vol.NS-23 , Issue.2 , pp. 991-993
    • Moller, P.A.1    Manh, P.T.2    Schwebel, C.3    Septier, A.4
  • 91
    • 0011747081 scopus 로고
    • Energetics of ions in quadrupole fields
    • P. H. Dawson, Energetics of ions in quadrupole fields, Int. J. Mass Spectrom. Ion Phys. 20 (1976) 237-245.
    • (1976) Int. J. Mass Spectrom. Ion Phys. , vol.20 , pp. 237-245
    • Dawson, P.H.1
  • 92
    • 33646869559 scopus 로고
    • The influence of collisions on ion motion in quadrupole fields
    • P. H. Dawson, The influence of collisions on ion motion in quadrupole fields, Int. J. Mass Spectrom. Ion Phys. 24 (1977) 447-451.
    • (1977) Int. J. Mass Spectrom. Ion Phys. , vol.24 , pp. 447-451
    • Dawson, P.H.1
  • 93
    • 0002725692 scopus 로고
    • The quadrupole ion store (QUISTOR). Part VIII. The theoretical estimation of ion kinetic energies: A comparative survey of the field
    • J. F. J. Todd, R. M. Waldren, R. F. Bonner, The quadrupole ion store (QUISTOR). Part VIII. The theoretical estimation of ion kinetic energies: A comparative survey of the field, Int. J. Mass Spectrom. Ion Phys. 34 (1980) 17-36.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.34 , pp. 17-36
    • Todd, J.F.J.1    Waldren, R.M.2    Bonner, R.F.3
  • 94
    • 0001127112 scopus 로고
    • The quadrupole ion store (QUISTOR). Part X. Space charge and ion stability. B. On the theoretical distribution and density of stored charge in RF quadrupole fields
    • J. F. J. Todd, R. M. Waldren, D. A. Freer, R. B. Turner, The quadrupole ion store (QUISTOR). Part X. Space charge and ion stability. B. On the theoretical distribution and density of stored charge in RF quadrupole fields, Int. J. Mass Spectrom. Ion Phys. 35 (1980) 107-150.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.35 , pp. 107-150
    • Todd, J.F.J.1    Waldren, R.M.2    Freer, D.A.3    Turner, R.B.4
  • 95
    • 0008971907 scopus 로고
    • The quadrupole ion store (QUISTOR). Part XI. The model of ion motion in a pseudo-potential well: An appraisal in terms of phasespace dynamics
    • J. F. J. Todd, D. A. Freer, R. M. Waldren, The quadrupole ion store (QUISTOR). Part XI. The model of ion motion in a pseudo-potential well: An appraisal in terms of phasespace dynamics, Int. J. Mass Spectrom. Ion Phys. 36 (1980) 185-203.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.36 , pp. 185-203
    • Todd, J.F.J.1    Freer, D.A.2    Waldren, R.M.3
  • 96
    • 0007624834 scopus 로고
    • The quadrupole ion store (QUISTOR). Part VI. Studies on phase-synchronised ion ejection: The effects of ejection pulse amplitude
    • R. M. Waldren, J. F. J. Todd, The quadrupole ion store (QUISTOR). Part VI. Studies on phase-synchronised ion ejection: The effects of ejection pulse amplitude, Int. J. Mass Spectrom. Ion Phys. 31 (1979) 15-29.
    • (1979) Int. J. Mass Spectrom. Ion Phys. , vol.31 , pp. 15-29
    • Waldren, R.M.1    Todd, J.F.J.2
  • 98
    • 0000202038 scopus 로고
    • Optical side-band cooling of visible atom cloud confined in parabolic well
    • W. Neuhauser, M. Hohenstatt, P. E. Toschek, H. G. Dehmelt, Optical side-band cooling of visible atom cloud confined in parabolic well, Phys. Rev. Lett. 41(4) (1978) 233-236.
    • (1978) Phys. Rev. Lett. , vol.41 , Issue.4 , pp. 233-236
    • Neuhauser, W.1    Hohenstatt, M.2    Toschek, P.E.3    Dehmelt, H.G.4
  • 99
    • 0018024262 scopus 로고
    • Visual observation and optical cooling of electrodynamically contained ions
    • W. Neuhauser, M. Hohenstatt, P. E. Toschek, H. G. Dehmelt, Visual observation and optical cooling of electrodynamically contained ions, Appl. Phys. 17 (1978) 123-129.
    • (1978) Appl. Phys. , vol.17 , pp. 123-129
    • Neuhauser, W.1    Hohenstatt, M.2    Toschek, P.E.3    Dehmelt, H.G.4
  • 100
    • 33646861834 scopus 로고
    • Etude théorique de l'influence des collisions élastiques sur un gaz dilué de particules chargées, confinées par un champ de radio-fréquence a symétrie quadrupolaire
    • J. André, Etude théorique de l'influence des collisions élastiques sur un gaz dilué de particules chargées, confinées par un champ de radio-fréquence a symétrie quadrupolaire, J. Phys. 37 (1976) 719-730.
    • (1976) J. Phys. , vol.37 , pp. 719-730
    • André, J.1
  • 101
    • 0018722855 scopus 로고
    • Invariance temporelle et propriétés statistiques énergétiques et spatiales d'ions confines dans une trappe quadrupolaire R.F.
    • J. André, F. Vedel, M. Vedel, Invariance temporelle et propriétés statistiques énergétiques et spatiales d'ions confines dans une trappe quadrupolaire R.F., J. Phys. Lett. 40(24) (1979) L633-L638.
    • (1979) J. Phys. Lett. , vol.40 , Issue.24 , pp. L633-L638
    • André, J.1    Vedel, F.2    Vedel, M.3
  • 102
    • 0008942375 scopus 로고
    • Method of mass analyzing a sample by use of a quadrupole ion trap
    • Canadian Patent 1,207,918
    • P. E. Kelley, G. C. Stafford, Jr., D. R. Stephens, Method of mass analyzing a sample by use of a quadrupole ion trap, U. S. Patent 4,540,884 (1985); Canadian Patent 1,207,918 (1986).
    • (1986)
    • Kelley, P.E.1    Stafford, G.C.2    Stephens, D.R.3
  • 103
    • 0000785613 scopus 로고
    • Experimentally determined proton affinities of 4-methyl-3-penten-2-one, 2-propyl ethanoate, and 4-hydroxy-4-methyl-2-pentanone in the gas phase
    • A. Kamar, A. B. Young, R. E. March, Experimentally determined proton affinities of 4-methyl-3-penten-2-one, 2-propyl ethanoate, and 4-hydroxy-4-methyl-2-pentanone in the gas phase, Can. J. Chem. 64 (1986) 2368-2370.
    • (1986) Can. J. Chem. , vol.64 , pp. 2368-2370
    • Kamar, A.1    Young, A.B.2    March, R.E.3
  • 104
    • 0001028174 scopus 로고
    • Gas phase ion/molecule reactions of dimethylsulfoxide
    • J. E. Fulford, J. W. Dupuis, R. E. March, Gas phase ion/molecule reactions of dimethylsulfoxide, Can. J. Chem. 56 (1978) 2324-2330.
    • (1978) Can. J. Chem. , vol.56 , pp. 2324-2330
    • Fulford, J.E.1    Dupuis, J.W.2    March, R.E.3
  • 105
    • 0346303593 scopus 로고
    • Plenum, New York, F. T. Arecchi, F. Strumia, and H. Walther (Eds.)
    • H. G. Dehmelt, in F. T. Arecchi, F. Strumia, and H. Walther (Eds.), Advances in Laser Spectroscopy, Plenum, New York, 1983, p. 153.
    • (1983) Advances in Laser Spectroscopy , pp. 153
    • Dehmelt, H.G.1
  • 106
    • 0000250108 scopus 로고
    • Trapped ions, laser cooling, and better clocks
    • D. J. Wineland, Trapped ions, laser cooling, and better clocks, Science 226 (1984) 395-400.
    • (1984) Science , vol.226 , pp. 395-400
    • Wineland, D.J.1
  • 107
    • 0019038826 scopus 로고
    • Laser probing of ions confined in a cylindrical radiofrequency trap
    • F. Plumelle, M. Desaintfuscien, J. L. Duchene, C. Audoin, Laser probing of ions confined in a cylindrical radiofrequency trap, Opt. Commun. 34 (1980) 71-76.
    • (1980) Opt. Commun. , vol.34 , pp. 71-76
    • Plumelle, F.1    Desaintfuscien, M.2    Duchene, J.L.3    Audoin, C.4
  • 112
    • 2942662180 scopus 로고
    • The laser-induced fluorescence spectrum of trapped bromine cyanide cations
    • F. J. Grieman, B. H. Mahan, A. O'Keefe, The laser-induced fluorescence spectrum of trapped bromine cyanide cations, J. Chem. Phys. 74 (1981) 857-861.
    • (1981) J. Chem. Phys. , vol.74 , pp. 857-861
    • Grieman, F.J.1    Mahan, B.H.2    O'Keefe, A.3
  • 114
    • 0000762792 scopus 로고
    • Multiphoton dissociation of ions derived from 2-Propanol in a QUISTOR with low-power cw infrared laser radiation
    • R. J. Hughes, R. E. March, A. B. Young, Multiphoton dissociation of ions derived from 2-Propanol in a QUISTOR with low-power cw infrared laser radiation, Int. J. Mass Spectrom. Ion Phys. 42 (1982) 255-263.
    • (1982) Int. J. Mass Spectrom. Ion Phys. , vol.42 , pp. 255-263
    • Hughes, R.J.1    March, R.E.2    Young, A.B.3
  • 115
    • 0006507116 scopus 로고
    • A comparative ion chemistry study of acetone, diacetone alcohol, and mesityl oxide
    • A. Kamar, A. B. Young, R. E. March, A comparative ion chemistry study of acetone, diacetone alcohol, and mesityl oxide, Can. J. Chem. 64 (1986) 1979-1988.
    • (1986) Can. J. Chem. , vol.64 , pp. 1979-1988
    • Kamar, A.1    Young, A.B.2    March, R.E.3
  • 117
    • 49549168531 scopus 로고
    • Confinement d'ions par un champ électrique de radio-fréquence dans une cage cylindrique
    • M. Benilan, C. Audoin, Confinement d'ions par un champ électrique de radio-fréquence dans une cage cylindrique, Int. J. Mass Spectrom. Ion Phys. 11 (1973) 421-432.
    • (1973) Int. J. Mass Spectrom. Ion Phys. , vol.11 , pp. 421-432
    • Benilan, M.1    Audoin, C.2
  • 118
    • 0002688673 scopus 로고
    • Cylindrical penning traps with orthogonalized anharmonicity compensation
    • G. Gabrielse, F. C. MacKintosh, Cylindrical penning traps with orthogonalized anharmonicity compensation, Int. J. Mass Spectrom. Ion Phys. 57 (1984) 1-18.
    • (1984) Int. J. Mass Spectrom. Ion Phys. , vol.57 , pp. 1-18
    • Gabrielse, G.1    MacKintosh, F.C.2
  • 120
    • 33646868894 scopus 로고
    • Confinement d'ions dans une cage cylindrique à champ quadrupolaire HF. Application à la spectrometrie de masse. I. Partie théorique
    • A. G. Nassiopoulos, P. A. Moller, A. Septier, Confinement d'ions dans une cage cylindrique à champ quadrupolaire HF. Application à la spectrometrie de masse. I. Partie théorique, Rev. Phys. Appl. 15 (1980) 1529-1541.
    • (1980) Rev. Phys. Appl. , vol.15 , pp. 1529-1541
    • Nassiopoulos, A.G.1    Moller, P.A.2    Septier, A.3
  • 121
    • 33646864850 scopus 로고
    • Confinement d'ions dans une cage cylindrique à champ quadrupolaire HF. Application à la spectrometrie de masse. II. Partie expérimentale
    • A. G. Nassiopoulos, P. A. Moller, A. Septier, Confinement d'ions dans une cage cylindrique à champ quadrupolaire HF. Application à la spectrometrie de masse. II. Partie expérimentale, Rev. Phys. Appl. 15 (1980) 1543-1552.
    • (1980) Rev. Phys. Appl. , vol.15 , pp. 1543-1552
    • Nassiopoulos, A.G.1    Moller, P.A.2    Septier, A.3
  • 122
    • 0001566255 scopus 로고
    • Some operational characteristics of a quadrupole ion storage mass spectrometer having cylindrical geometry
    • R. E. Mather, R. M. Waldren, J. F. J. Todd, R. E. March, Some operational characteristics of a quadrupole ion storage mass spectrometer having cylindrical geometry, Int. J. Mass Spectrom. Ion Phys. 33 (1980) 201-230.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.33 , pp. 201-230
    • Mather, R.E.1    Waldren, R.M.2    Todd, J.F.J.3    March, R.E.4
  • 124
    • 0000294749 scopus 로고
    • Simple electrodes for quadrupole ion traps
    • E. C. Beaty, Simple electrodes for quadrupole ion traps, J. Appl. Phys. 61(6) (1987) 2118-2122.
    • (1987) J. Appl. Phys. , vol.61 , Issue.6 , pp. 2118-2122
    • Beaty, E.C.1
  • 128
    • 0002372148 scopus 로고
    • Time-resolved photoionization mass spectrometry in the millisecond range
    • C. Lifshitz,Y. Malinovich, Time-resolved photoionization mass spectrometry in the millisecond range, Int. J. Mass Spectrom. Ion Processes 60 (1984) 99-105.
    • (1984) Int. J. Mass Spectrom. Ion Processes , vol.60 , pp. 99-105
    • Lifshitz, C.1    Malinovich, Y.2
  • 129
    • 49249144998 scopus 로고
    • Trapping of ions injected from an external source into a three-dimensional RF quadrupole field
    • M. Nand Kishore, P. K. Ghosh, Trapping of ions injected from an external source into a three-dimensional RF quadrupole field, Int. J. Mass Spectrom. Ion Phys. 29 (1979) 345-350.
    • (1979) Int. J. Mass Spectrom. Ion Phys. , vol.29 , pp. 345-350
    • Nand Kishore, M.1    Ghosh, P.K.2
  • 130
    • 0010037515 scopus 로고
    • The quadrupole ion store (QUISTOR). Part XII. The trapping of ions injected from an external source: A description in terms of phase-space dynamics
    • J. F. J. Todd, D. A. Freer, R. M. Waldren, The quadrupole ion store (QUISTOR). Part XII. The trapping of ions injected from an external source: A description in terms of phase-space dynamics, Int. J. Mass Spectrom. Ion Phys. 36 (1980) 371-386.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.36 , pp. 371-386
    • Todd, J.F.J.1    Freer, D.A.2    Waldren, R.M.3
  • 131
    • 50849148663 scopus 로고
    • Confinement of pulse-injected external ions in a radiofrequency quadrupole ion trap
    • C.-S. O, H. A. Schuessler, Confinement of pulse-injected external ions in a radiofrequency quadrupole ion trap, Int. J. Mass Spectrom. Ion Phys. 40 (1981) 53-66.
    • (1981) Int. J. Mass Spectrom. Ion Phys. , vol.40 , pp. 53-66
    • C.-S.O.1    Schuessler, H.A.2
  • 132
    • 0345498092 scopus 로고
    • Trapping of pulse injected Ions in a radiofrequency quadrupole trap
    • C.-S. O, H. A. Schuessler, Trapping of pulse injected Ions in a radiofrequency quadrupole trap, Rev. Phys. Appl. 17 (1982) 83.
    • (1982) Rev. Phys. Appl. , vol.17 , pp. 83
    • C.-S.O.1    Schuessler, H.A.2
  • 136
  • 137
    • 33646875805 scopus 로고
    • Bimolecular reactions of carbon dioxide microcluster ions with water, investigated with a tandem molecular beam QUISTOR- quadrupole instrument
    • Denver, CO, May 24-29
    • G. Romanowski, R. H. Gabling, K.-P. Wanczek, Bimolecular reactions of carbon dioxide microcluster ions with water, investigated with a tandem molecular beam QUISTOR- quadrupole instrument. Proc. 35th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics, Denver, CO, May 24-29, 1987, pp. 777-778.
    • (1987) Proc. 35th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics , pp. 777-778
    • Romanowski, G.1    Gabling, R.H.2    Wanczek, K.-P.3
  • 140
    • 23044462060 scopus 로고
    • Weak peak enhancement by selective ion trapping in a quadrupole storage source
    • G. Lawson, J. F. J. Todd, Weak peak enhancement by selective ion trapping in a quadrupole storage source, Anal. Chem. 49(11) (1977) 1619-1622.
    • (1977) Anal. Chem. , vol.49 , Issue.11 , pp. 1619-1622
    • Lawson, G.1    Todd, J.F.J.2
  • 142
    • 33646889604 scopus 로고
    • Stability diagram determination and ion trajectory modelling for the ion trap mass spectrometer
    • Denver, CO, May 24-29
    • J. F. J. Todd, J. J. Bexon, R. D. Smith, Stability diagram determination and ion trajectory modelling for the ion trap mass spectrometer. Proc. 35th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics, Denver, CO, May 24-29, 1987, pp. 787-788.
    • (1987) Proc. 35th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics , pp. 787-788
    • Todd, J.F.J.1    Bexon, J.J.2    Smith, R.D.3
  • 143
    • 33646856075 scopus 로고
    • Ion trajectory modelling for the ion trap mass spectrometer
    • paper presented at the Sixteenth Meeting British Mass Spectrometry Society, York, U.K.
    • J. F. J. Todd, J. J. Bexon, R. D. Smith, Ion trajectory modelling for the ion trap mass spectrometer, paper presented at the Sixteenth Meeting British Mass Spectrometry Society, York, U.K., 1987, pp. 128-131.
    • (1987) , pp. 128-131
    • Todd, J.F.J.1    Bexon, J.J.2    Smith, R.D.3
  • 148
    • 0003843122 scopus 로고
    • Elsevier, Amsterdam, Reprinted as an "American Vacuum Society Classic" by the American Institute of Physics. (ISBN 1563964554)
    • P. H. Dawson, Quadrupole Mass Spectrometry and Its Applications, Elsevier, Amsterdam, 1976. Reprinted as an "American Vacuum Society Classic" by the American Institute of Physics. (ISBN 1563964554)
    • (1976) Quadrupole Mass Spectrometry and Its Applications
    • Dawson, P.H.1
  • 155
    • 48749143322 scopus 로고
    • The general form of the quadrupole ion trap potential
    • R. D. Knight, The general form of the quadrupole ion trap potential, Int. J. Mass Spectrom. Ion Processes 51 (1983) 127-131.
    • (1983) Int. J. Mass Spectrom. Ion Processes , vol.51 , pp. 127-131
    • Knight, R.D.1
  • 158
    • 0016129557 scopus 로고
    • Higher zones of stability for the quadrupole mass filter
    • P. H. Dawson, Higher zones of stability for the quadrupole mass filter, J. Vac. Sci. Technol. 11(6) (1974) 1151.
    • (1974) J. Vac. Sci. Technol. , vol.11 , Issue.6 , pp. 1151
    • Dawson, P.H.1
  • 159
    • 33646859317 scopus 로고
    • Quadrupoles operating in the second stability region
    • paper presented at the Thirty-Second Annual Conference of the American Society for Mass Spectrometry and Allied Topics, San Antonio, TX, May/June
    • P. H. Dawson, Y. Bingqi, Quadrupoles operating in the second stability region, paper presented at the Thirty-Second Annual Conference of the American Society for Mass Spectrometry and Allied Topics, San Antonio, TX, May/June 1984, pp. 505-506.
    • (1984) , pp. 505-506
    • Dawson, P.H.1    Bingqi, Y.2
  • 160
    • 0002043362 scopus 로고
    • The second stability region of the quadrupole mass filter. II. Experimental results
    • P. H. Dawson, Y. Bingqi, The second stability region of the quadrupole mass filter. II. Experimental results, Int. J. Mass Spectrom. Ion Phys. 56 (1984) 41.
    • (1984) Int. J. Mass Spectrom. Ion Phys. , vol.56 , pp. 41
    • Dawson, P.H.1    Bingqi, Y.2
  • 161
    • 0002530860 scopus 로고
    • The second stability region of the quadrupole mass filter. I. Ion optical properties
    • P. H. Dawson,Y. Bingqi, The second stability region of the quadrupole mass filter. I. Ion optical properties, Int. J. Mass Spectrom. Ion Phys. 56 (1984) 25.
    • (1984) Int. J. Mass Spectrom. Ion Phys. , vol.56 , pp. 25
    • Dawson, P.H.1    Bingqi, Y.2
  • 162
    • 0038166642 scopus 로고
    • Apparatus for separating charged particles of different specific charges
    • U.S. Patent 2,939,952, June 7
    • W. Paul, H. Steinwedel, Apparatus for separating charged particles of different specific charges, German Patent 944,900 (1956); U.S. Patent 2,939,952 (June 7, 1960).
    • (1960)
    • Paul, W.1    Steinwedel, H.2
  • 166
    • 84949524973 scopus 로고    scopus 로고
    • personal communication
    • R. D. Knight, personal communication, 2004.
    • (2004)
    • Knight, R.D.1
  • 169
    • 84949498869 scopus 로고    scopus 로고
    • personal communication
    • M. Splendore, personal communication, 1999.
    • (1999)
    • Splendore, M.1
  • 170
    • 36849140902 scopus 로고
    • Electrodynamic containment of charged particles
    • R. F. Wuerker, H. Shelton, R. V. Langmuir, Electrodynamic containment of charged particles, J. Appl. Phys. 30 (1959) 342-349.
    • (1959) J. Appl. Phys. , vol.30 , pp. 342-349
    • Wuerker, R.F.1    Shelton, H.2    Langmuir, R.V.3
  • 171
    • 77956859716 scopus 로고
    • Radiofrequency spectroscopy of stored ions I: Storage
    • D. R. Bates (Ed.), Academic, New York
    • H. G. Dehmelt, Radiofrequency spectroscopy of stored ions I: Storage , in D. R. Bates (Ed.), Advances in Atomic and Molecular Physics, Vol. 3, Academic, New York, 1967, pp. 53-72.
    • (1967) Advances in Atomic and Molecular Physics , vol.3 , pp. 53-72
    • Dehmelt, H.G.1
  • 172
    • 0002365743 scopus 로고
    • The quadrupole ion store (QUISTOR). Part IX. Space-charge and ion stability. A. Theoretical background and experimental results
    • J. F. J. Todd, R. M. Waldren, R. E. Mather, The quadrupole ion store (QUISTOR). Part IX. Space-charge and ion stability. A. Theoretical background and experimental results, Int. J. Mass Spectrom. Ion Phys. 34 (1980) 325-349.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.34 , pp. 325-349
    • Todd, J.F.J.1    Waldren, R.M.2    Mather, R.E.3
  • 173
    • 0020119927 scopus 로고
    • The quadrupole mass filter as a commercial isotope separator
    • M. F. Finlan, R. F. Sunderland, J. F. J. Todd, The quadrupole mass filter as a commercial isotope separator, Nucl. Instrum. Methods 195 (1982) 447-456.
    • (1982) Nucl. Instrum. Methods , vol.195 , pp. 447-456
    • Finlan, M.F.1    Sunderland, R.F.2    Todd, J.F.J.3
  • 174
    • 0002115109 scopus 로고
    • Die dreidimensionale Stabilisirung von Ladungsträgern in einem Vierpolfeld
    • E. Fischer, Die dreidimensionale Stabilisirung von Ladungsträgern in einem Vierpolfeld, Z. Phys. 156 (1959) 1-26.
    • (1959) Z. Phys. , vol.156 , pp. 1-26
    • Fischer, E.1
  • 175
    • 0001131736 scopus 로고
    • Formation et confinement d'ions multicharges dans un champ quadrupolaire a haute fréquence
    • C. Schwebel, P. A. Möller, P. T. Manh, Formation et confinement d'ions multicharges dans un champ quadrupolaire a haute fréquence, Rev. Phys. Appl. 10 (1975) 227-239.
    • (1975) Rev. Phys. Appl. , vol.10 , pp. 227-239
    • Schwebel, C.1    Möller, P.A.2    Manh, P.T.3
  • 176
    • 33646890738 scopus 로고
    • Three-dimensional accumulation quadrupole mass spectrometer
    • E. P. Sheretov, V. A. Zenkin, V. F. Samodurov, Three-dimensional accumulation quadrupole mass spectrometer, Zh. Tekh. Fiz. 43 (1973) 441.
    • (1973) Zh. Tekh. Fiz. , vol.43 , pp. 441
    • Sheretov, E.P.1    Zenkin, V.A.2    Samodurov, V.F.3
  • 177
    • 1642362401 scopus 로고
    • Physics of atoms and molecules
    • W. Hanle and H. Kleinpoppen (Eds.), Plenum, New York
    • H. A. Schuessler, Physics of atoms and molecules , in W. Hanle and H. Kleinpoppen (Eds.), Progress in Atomic Spectroscopy, Part B, Plenum, New York, 1979, p. 999.
    • (1979) Progress in Atomic Spectroscopy, Part B , pp. 999
    • Schuessler, H.A.1
  • 178
    • 0019033927 scopus 로고
    • Radiofrequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap
    • J. E. Fulford, D.-N. Hoa, R. J. Hughes, R. E. March, R. E. Bonner, R. F. Wong, Radiofrequency mass selective excitation and resonant ejection of ions in a three-dimensional quadrupole ion trap, J. Vac. Sci. Technol. 17 (1980) 829-835.
    • (1980) J. Vac. Sci. Technol. , vol.17 , pp. 829-835
    • Fulford, J.E.1    Hoa, D.-N.2    Hughes, R.J.3    March, R.E.4    Bonner, R.E.5    Wong, R.F.6
  • 181
  • 182
    • 0006468004 scopus 로고
    • The effect of charge exchange collisions on the motion of ions in three-dimensional quadrupole electric fields. Part II. Program improvements and fundamental results
    • R. F. Bonner, R. E. March, The effect of charge exchange collisions on the motion of ions in three-dimensional quadrupole electric fields. Part II. Program improvements and fundamental results, Int. J. Mass Spectrom. Ion Phys. 25 (1977) 411-431.
    • (1977) Int. J. Mass Spectrom. Ion Phys. , vol.25 , pp. 411-431
    • Bonner, R.F.1    March, R.E.2
  • 183
    • 0006424350 scopus 로고
    • Effects of charge-exchange reactions on the motion of ions in three-dimensional quadrupole electric fields. Part III. A two-ion model
    • M. C. Doran, J. E. Fulford, R. J. Hughes, Y. Morita, R. E. March, R. F. Bonner, Effects of charge-exchange reactions on the motion of ions in three-dimensional quadrupole electric fields. Part III. A two-ion model, Int. J. Mass Spectrom. Ion Phys. 33 (1980) 139-158.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.33 , pp. 139-158
    • Doran, M.C.1    Fulford, J.E.2    Hughes, R.J.3    Morita, Y.4    March, R.E.5    Bonner, R.F.6
  • 184
    • 19544389937 scopus 로고
    • Radiofrequency spectroscopy of stored ions I: Spectroscopy
    • D. R. Bates (Ed.), Academic, New York
    • H. G. Dehmelt, Radiofrequency spectroscopy of stored ions I: Spectroscopy , in D. R. Bates (Ed.), Advances in Atomic and Molecular Physics, Vol. 5, Academic, New York, 1969, pp. 109-154.
    • (1969) Advances in Atomic and Molecular Physics , vol.5 , pp. 109-154
    • Dehmelt, H.G.1
  • 185
    • 0000642316 scopus 로고
    • Influence of space charge on the computed statistical properties of stored ions cooled by a buffer gas in a quadrupole rf trap
    • F. Vedel, J André, Influence of space charge on the computed statistical properties of stored ions cooled by a buffer gas in a quadrupole rf trap, Phys. Rev. A 29 (1984) 2098-2101.
    • (1984) Phys. Rev. A , vol.29 , pp. 2098-2101
    • Vedel, F.1    André, J.2
  • 186
    • 0002586885 scopus 로고
    • Equilibrium space charge distribution in a quadrupole ion trap
    • S. Guan, A. G. Marshall, Equilibrium space charge distribution in a quadrupole ion trap, J. Am. Soc. Mass Spectrom. 5 (1994) 64-71.
    • (1994) J. Am. Soc. Mass Spectrom. , vol.5 , pp. 64-71
    • Guan, S.1    Marshall, A.G.2
  • 187
    • 0032232010 scopus 로고    scopus 로고
    • Comparison of equilibrium ion density distribution and trapping force in Penning, Paul, and combined ion traps
    • G.-Z. Li, S. Guan, A. G. Marshall, Comparison of equilibrium ion density distribution and trapping force in Penning, Paul, and combined ion traps, J. Am. Soc. Mass Spectrom. 9 (1998) 473-481.
    • (1998) J. Am. Soc. Mass Spectrom. , vol.9 , pp. 473-481
    • Li, G.-Z.1    Guan, S.2    Marshall, A.G.3
  • 190
    • 84949496956 scopus 로고
    • Method of mass analysing a sample
    • G. C. Stafford, Jr., D. M. Taylor, S. C. Bradshaw, Method of mass analysing a sample, European Patent 0,237,268 (1991).
    • (1991)
    • Stafford, G.C.1    Taylor, D.M.2    Bradshaw, S.C.3
  • 191
    • 84867496998 scopus 로고
    • Method of increasing the dynamic range and sensitivity of a quadrupole ion trap mass spectrometer
    • G. C. Stafford, Jr., D. M. Taylor, S. C. Bradshaw, Method of increasing the dynamic range and sensitivity of a quadrupole ion trap mass spectrometer, U.S. Patent 5,107,109 (1992).
    • (1992)
    • Stafford, G.C.1    Taylor, D.M.2    Bradshaw, S.C.3
  • 193
    • 0002725692 scopus 로고
    • The quadrupole ion store (QUISTOR). Part VIII. The theoretical estimation of ion kinetic energies: A comparative survey of the field
    • J. F. J. Todd, R. M. Waldren, R. F. Bonner, The quadrupole ion store (QUISTOR). Part VIII. The theoretical estimation of ion kinetic energies: A comparative survey of the field, Int. J. Mass Spectrom. Ion Phys. 34 (1980) 17-36.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.34 , pp. 17-36
    • Todd, J.F.J.1    Waldren, R.M.2    Bonner, R.F.3
  • 194
    • 0002150208 scopus 로고
    • The use of matrix methods and phase-space dynamics of the modelling of RF quadrupole-type device performance
    • D. Price and J. F. J. Todd (Eds.), Heyden, London
    • R. M. Waldren, J. F. J. Todd, The use of matrix methods and phase-space dynamics of the modelling of RF quadrupole-type device performance , in D. Price and J. F. J. Todd (Eds.), Dynamic Mass Spectrometry, Vol. 5, Heyden, London, 1978, pp. 14-40.
    • (1978) Dynamic Mass Spectrometry , vol.5 , pp. 14-40
    • Waldren, R.M.1    Todd, J.F.J.2
  • 195
    • 0008971907 scopus 로고
    • The quadrupole ion store (QUISTOR). Part XI. The model ion motion in a pseudo-potential well: An appraisal in terms of phase-space dynamics
    • J. F. J. Todd, D. A. Freer, R. M. Waldren, The quadrupole ion store (QUISTOR). Part XI. The model ion motion in a pseudo-potential well: An appraisal in terms of phase-space dynamics, Int. J. Mass Spectrom. Ion Phys. 36 (1980) 185-203.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.36 , pp. 185-203
    • Todd, J.F.J.1    Freer, D.A.2    Waldren, R.M.3
  • 196
    • 0001090108 scopus 로고
    • Isotope separation by an electrical mass filter
    • F. von Busch, W. Paul, Isotope separation by an electrical mass filter, Z. Phys. 164 (1961) 581-587.
    • (1961) Z. Phys. , vol.164 , pp. 581-587
    • von Busch, F.1    Paul, W.2
  • 197
    • 51249193058 scopus 로고
    • Über den einfluss von fehlern de magnetischen feldes auf die betatronschwingungen in synchrotron mit starker stabilisierung
    • G. Lüders, Über den einfluss von fehlern de magnetischen feldes auf die betatronschwingungen in synchrotron mit starker stabilisierung, Suppl. Nuovo Cimento (Series X) 2 (1955) 1075-1146.
    • (1955) Suppl. Nuovo Cimento (Series X) , vol.2 , pp. 1075-1146
    • Lüders, G.1
  • 198
    • 0001057430 scopus 로고
    • Non-linear resonances in the electric mass filter as a consequence of field errors
    • F. von Busch,W. Paul, Non-linear resonances in the electric mass filter as a consequence of field errors, Z. Phys. 164 (1961) 588-594.
    • (1961) Z. Phys. , vol.164 , pp. 588-594
    • von Busch, F.1    Paul, W.2
  • 203
    • 0002832383 scopus 로고
    • Non-linear resonances in quadrupole mass spectrometers due to imperfect fields I. The quadupole ion trap
    • P. H. Dawson, N. R. Whetten, Non-linear resonances in quadrupole mass spectrometers due to imperfect fields I. The quadupole ion trap, Int. J. Mass Spectrom. Ion Phys. 2 (1969) 45-59.
    • (1969) Int. J. Mass Spectrom. Ion Phys. , vol.2 , pp. 45-59
    • Dawson, P.H.1    Whetten, N.R.2
  • 204
    • 0002865070 scopus 로고
    • Ion storage in three-dimensional, rotationally symmetric, quadrupole fields. II. A sensitive mass spectrometer
    • P. H. Dawson, N. R. Whetten, Ion storage in three-dimensional, rotationally symmetric, quadrupole fields. II. A sensitive mass spectrometer, J. Vac. Sci. Technol. 5 (1968) 11-18.
    • (1968) J. Vac. Sci. Technol. , vol.5 , pp. 11-18
    • Dawson, P.H.1    Whetten, N.R.2
  • 205
    • 0000260453 scopus 로고
    • The non-linear resonance QUISTOR. Part 1. Potential distribution in hyperboloidal QUISTORs
    • Y. Wang, J. Franzen, The non-linear resonance QUISTOR. Part 1. Potential distribution in hyperboloidal QUISTORs, Int. J. Mass Spectrom. Ion Processes 112 (1992) 167-178.
    • (1992) Int. J. Mass Spectrom. Ion Processes , vol.112 , pp. 167-178
    • Wang, Y.1    Franzen, J.2
  • 206
    • 0000700670 scopus 로고
    • The non-linear resonance ion trap. Part 2. A general theoretical analysis
    • Y. Wang, J. Franzen, K. P. Wanczek, The non-linear resonance ion trap. Part 2. A general theoretical analysis, Int. J. Mass Spectrom. Ion Processes 124 (1993) 125-144.
    • (1993) Int. J. Mass Spectrom. Ion Processes , vol.124 , pp. 125-144
    • Wang, Y.1    Franzen, J.2    Wanczek, K.P.3
  • 207
    • 0141998373 scopus 로고
    • Non-linear resonances in quadrupole mass spectrometers due to imperfect fields. II. The quadrupole mass filter and the monopole mass spectrometer
    • P. H. Dawson, N. R. Whetten, Non-linear resonances in quadrupole mass spectrometers due to imperfect fields. II. The quadrupole mass filter and the monopole mass spectrometer, Int. J. Mass Spectrom. Ion Phys. 3 (1969) 1-12.
    • (1969) Int. J. Mass Spectrom. Ion Phys. , vol.3 , pp. 1-12
    • Dawson, P.H.1    Whetten, N.R.2
  • 208
    • 0019927603 scopus 로고
    • Fundamentals of ion motion in electric radio-frequency multipole field
    • M. H. Friedman, A. L. Yergey, J. E. Campana, Fundamentals of ion motion in electric radio-frequency multipole field, J. Phys. E Sci. Instrum. 15 (1982) 53-61.
    • (1982) J. Phys. E Sci. Instrum. , vol.15 , pp. 53-61
    • Friedman, M.H.1    Yergey, A.L.2    Campana, J.E.3
  • 209
    • 0001239551 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. I. Principle of operation and analytical theory of multipole devices with two-dimensional electric fields
    • I. Szabo, New ion-optical devices utilizing oscillatory electric fields. I. Principle of operation and analytical theory of multipole devices with two-dimensional electric fields, Int. J. Mass Spectrom. Ion Processes 73 (1986) 197-235.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 197-235
    • Szabo, I.1
  • 210
    • 0000669347 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. II. Stability of ion motion in a two-dimensional hexapole field
    • C. Hägg, I. Szabo, New ion-optical devices utilizing oscillatory electric fields. II. Stability of ion motion in a two-dimensional hexapole field, Int. J. Mass Spectrom. Ion Processes 73 (1986) 237-275.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 237-275
    • Hägg, C.1    Szabo, I.2
  • 211
    • 0000669346 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. III. Stability of ion motion in a two-dimensional octopole field
    • C. Hägg, I. Szabo, New ion-optical devices utilizing oscillatory electric fields. III. Stability of ion motion in a two-dimensional octopole field, Int. J. Mass Spectrom. Ion Processes 73 (1986) 277-294.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 277-294
    • Hägg, C.1    Szabo, I.2
  • 212
    • 0000669342 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. IV. Computer simulations of the transport of an ion beam through an ideal quadrupole, hexapole, and octopole operating in the RF-only mode
    • C. Hägg, I. Szabo, New ion-optical devices utilizing oscillatory electric fields. IV. Computer simulations of the transport of an ion beam through an ideal quadrupole, hexapole, and octopole operating in the RF-only mode, Int. J. Mass Spectrom. Ion Processes 73 (1986) 295-312.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 295-312
    • Hägg, C.1    Szabo, I.2
  • 213
    • 84990672936 scopus 로고
    • Computer modelling of fragmentation processes in radio frequency multipole collision cells
    • S. C. Davis, B. Wright, Computer modelling of fragmentation processes in radio frequency multipole collision cells, Rapid Commun. Mass Spectrom. 4 (1990) 186-197.
    • (1990) Rapid Commun. Mass Spectrom. , vol.4 , pp. 186-197
    • Davis, S.C.1    Wright, B.2
  • 214
    • 0001355897 scopus 로고
    • Simulation study of an ion cage with superimposed multipole fields
    • J. Franzen, Simulation study of an ion cage with superimposed multipole fields, Int. J. Mass Spectrom. Ion Processes 106 (1991) 63-78.
    • (1991) Int. J. Mass Spectrom. Ion Processes , vol.106 , pp. 63-78
    • Franzen, J.1
  • 215
    • 0000575240 scopus 로고
    • The non-linear ion trap. Part 3. multipole components in three types of practical ion trap
    • Y. Wang, J. Franzen, The non-linear ion trap. Part 3. multipole components in three types of practical ion trap, Int. J. Mass Spectrom. Ion Processes 132 (1994) 155-172.
    • (1994) Int. J. Mass Spectrom. Ion Processes , vol.132 , pp. 155-172
    • Wang, Y.1    Franzen, J.2
  • 218
    • 0001384156 scopus 로고
    • Investigation of "ghost" peaks caused by non-linear fields in the ion trap mass spectrometer
    • W. Mo, M. L. Langford, J. F. J. Todd, Investigation of "ghost" peaks caused by non-linear fields in the ion trap mass spectrometer, Rapid Commun. Mass Spectrom. 9 (1995) 107-113.
    • (1995) Rapid Commun. Mass Spectrom. , vol.9 , pp. 107-113
    • Mo, W.1    Langford, M.L.2    Todd, J.F.J.3
  • 221
    • 84990713552 scopus 로고
    • A phenomenological description of a black hole for collisionally induced decomposition products in ion-trap mass spectrometry
    • F. Guidugli, P. Traldi, A phenomenological description of a black hole for collisionally induced decomposition products in ion-trap mass spectrometry, Rapid Commun. Mass Spectrom. 5 (1991) 343-348.
    • (1991) Rapid Commun. Mass Spectrom. , vol.5 , pp. 343-348
    • Guidugli, F.1    Traldi, P.2
  • 225
    • 84990704680 scopus 로고
    • The use of dynamically programmed scans to generate parent-ion tandem mass spectra with the ion-trap mass spectrometer
    • A. D. Penman, J. F. J. Todd, D. A. Thorner, R. D. Smith, The use of dynamically programmed scans to generate parent-ion tandem mass spectra with the ion-trap mass spectrometer, Rapid Commun. Mass Spectrom. 4 (1990) 108-113.
    • (1990) Rapid Commun. Mass Spectrom. , vol.4 , pp. 108-113
    • Penman, A.D.1    Todd, J.F.J.2    Thorner, D.A.3    Smith, R.D.4
  • 226
    • 33646876030 scopus 로고
    • Dynamically programmed scans
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 11
    • A. M. Franklin, J. F. J. Todd, Dynamically programmed scans , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. 3, CRC Press, Boca Raton, FL, 1995, Chapter 11.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3
    • Franklin, A.M.1    Todd, J.F.J.2
  • 229
    • 84989064859 scopus 로고
    • Boundary effects and collisional activation in a quadrupole ion trap
    • C. Paradisi, J. F. J. Todd, P. Traldi, U. Vettori, Boundary effects and collisional activation in a quadrupole ion trap, Org. Mass Spectrom. 27 (1992) 251-254.
    • (1992) Org. Mass Spectrom. , vol.27 , pp. 251-254
    • Paradisi, C.1    Todd, J.F.J.2    Traldi, P.3    Vettori, U.4
  • 230
    • 43949165592 scopus 로고
    • Nonlinear resonance effects during ion storage in a quadrupole ion trap
    • D. M. Eades, J. V. Johnson, R. A. Yost, Nonlinear resonance effects during ion storage in a quadrupole ion trap, J. Am. Soc. Mass Spectrom. 4 (1993) 917-929.
    • (1993) J. Am. Soc. Mass Spectrom. , vol.4 , pp. 917-929
    • Eades, D.M.1    Johnson, J.V.2    Yost, R.A.3
  • 231
    • 3743145803 scopus 로고
    • The mass filter: design and performance
    • P. H. Dawson (Ed.), Elsevier:Amsterdam, Chapter VI. Reprinted as an "American Vacuum Society Classic" by the American Institute of Physics. (ISBN 1563964554)
    • W. E. Austin, A. E. Holme, J. H. Leck, The mass filter: design and performance , in P. H. Dawson (Ed.), Quadrupole Mass Spectrometry and Its Applications, Elsevier:Amsterdam, 1976. Chapter VI. Reprinted as an "American Vacuum Society Classic" by the American Institute of Physics. (ISBN 1563964554)
    • (1976) Quadrupole Mass Spectrometry and Its Applications
    • Austin, W.E.1    Holme, A.E.2    Leck, J.H.3
  • 232
    • 0141989738 scopus 로고    scopus 로고
    • Linear quadrupoles with added octopole fields
    • M. Sudakov, D. J. Douglas, Linear quadrupoles with added octopole fields, Rapid Commun. Mass Spectrom. 17 (2003) 2290-2294.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , pp. 2290-2294
    • Sudakov, M.1    Douglas, D.J.2
  • 234
    • 84949512652 scopus 로고    scopus 로고
    • Fragmentation of ions by resonant excitation in a high order multipole field, low pressure ion trap
    • F. Londry, B. A. Collings,W. R. Stott, Fragmentation of ions by resonant excitation in a high order multipole field, low pressure ion trap, U.S. Patent Application No. 2003/0189171 (2003).
    • (2003)
    • Londry, F.1    Collings, B.A.2    Stott, W.R.3
  • 236
    • 0001700222 scopus 로고
    • Commercialization of the quadrupole ion trap
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 4
    • J. E. P. Syka, Commercialization of the quadrupole ion trap , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry,Vol. 1, CRC Press, Boca Raton, FL, 1995, Chapter 4
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.1
    • Syka, J.E.P.1
  • 237
    • 84949528593 scopus 로고
    • The geometry of the finnigan ion trap:History and theory, paper presented at the Ninth Asilomar Conference on Mass Spectrometry
    • September
    • J. E. P. Syka, The geometry of the finnigan ion trap:History and theory, paper presented at the Ninth Asilomar Conference on Mass Spectrometry, September 1992.
    • (1992)
    • Syka, J.E.P.1
  • 238
    • 0034716129 scopus 로고    scopus 로고
    • Quadrupole ion trap mass spectrometry: A view at the turn of the century
    • R. E. March, Quadrupole ion trap mass spectrometry: A view at the turn of the century, Int. J. Mass Spectrom. 200 (2000) 285-312.
    • (2000) Int. J. Mass Spectrom. , vol.200 , pp. 285-312
    • March, R.E.1
  • 239
    • 0006497611 scopus 로고
    • Extension of the mass range of a commercial ion trap using monopolar resonance ejection
    • X. Wang, D. K. Bohme, R. E. March, Extension of the mass range of a commercial ion trap using monopolar resonance ejection, Can. J. Appl. Spectrosc. 38(2) (1993) 55-60.
    • (1993) Can. J. Appl. Spectrosc. , vol.38 , Issue.2 , pp. 55-60
    • Wang, X.1    Bohme, D.K.2    March, R.E.3
  • 240
    • 84949493342 scopus 로고
    • unscheduled announcement on ion trap geometry, at the 40th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics,Washington, DC, May 31-June 5
    • J. Louris, unscheduled announcement on ion trap geometry, at the 40th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics,Washington, DC, May 31-June 5, 1992.
    • (1992)
    • Louris, J.1
  • 242
    • 84990707610 scopus 로고
    • Mass displacement in ion trap mass spectrometry:A unique and valuable tool in ion structural studies
    • P. Traldi, O. Curcuruto, O. Bortolini, Mass displacement in ion trap mass spectrometry:A unique and valuable tool in ion structural studies, Rapid Commun. Mass Spectrom. 6 (1992) 410-412.
    • (1992) Rapid Commun. Mass Spectrom. , vol.6 , pp. 410-412
    • Traldi, P.1    Curcuruto, O.2    Bortolini, O.3
  • 243
    • 84989012035 scopus 로고
    • Mass displacements in ion trap mass spectrometry:Can they be related to electronic properties of the substitutent groups of the ions under investigation?
    • O. Bortolini, S. Catinella, P. Traldi, Mass displacements in ion trap mass spectrometry:Can they be related to electronic properties of the substitutent groups of the ions under investigation? Org. Mass Spectrom. 27 (1992) 927-928.
    • (1992) Org. Mass Spectrom. , vol.27 , pp. 927-928
    • Bortolini, O.1    Catinella, S.2    Traldi, P.3
  • 245
    • 33646871649 scopus 로고
    • Evaluation of the polarizability of gaseous ions
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 4
    • O. Bortolini, P. Traldi, Evaluation of the polarizability of gaseous ions , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. II, CRC Press, Boca Raton, FL, 1995, Chapter 4.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.2
    • Bortolini, O.1    Traldi, P.2
  • 246
    • 84989132282 scopus 로고
    • Estimation of the polarizability of organic ions by ion trap measurements
    • O. Bortolini, S. Catinella, P. Traldi, Estimation of the polarizability of organic ions by ion trap measurements, Org. Mass Spectrom. 28 (1993) 428-432.
    • (1993) Org. Mass Spectrom. , vol.28 , pp. 428-432
    • Bortolini, O.1    Catinella, S.2    Traldi, P.3
  • 247
    • 84994924383 scopus 로고
    • Evalutation of dipole moments of organic ions in the gas phase
    • O. Bortolini, S. Catinella, P. Traldi, Evalutation of dipole moments of organic ions in the gas phase, Org. Mass Spectrom. 29 (1994) 273-276.
    • (1994) Org. Mass Spectrom. , vol.29 , pp. 273-276
    • Bortolini, O.1    Catinella, S.2    Traldi, P.3
  • 248
    • 84990721682 scopus 로고
    • Mass displacements in a quadrupole mass filter: A tool for evaluation of intrinsic dipole moments of ionic species
    • P. Traldi, D. Favretto, Mass displacements in a quadrupole mass filter: A tool for evaluation of intrinsic dipole moments of ionic species, Rapid Commun. Mass Spectrom. 6 (1992) 543-544.
    • (1992) Rapid Commun. Mass Spectrom. , vol.6 , pp. 543-544
    • Traldi, P.1    Favretto, D.2
  • 249
    • 0042206633 scopus 로고    scopus 로고
    • Theory, simulation and measurement of chemical mass shifts in RF quadrupole ion traps
    • W. R. Plass, H. Li, R. G. Cooks, Theory, simulation and measurement of chemical mass shifts in RF quadrupole ion traps, Int. J. Mass Spectrom. 228 (2003) 237-267.
    • (2003) Int. J. Mass Spectrom. , vol.228 , pp. 237-267
    • Plass, W.R.1    Li, H.2    Cooks, R.G.3
  • 250
    • 0016034809 scopus 로고
    • Macroscopic particle motion in quadrupole fields
    • N. R. Whetten, Macroscopic particle motion in quadrupole fields, J. Vac. Sci. Technol. 11 (1974) 551-518.
    • (1974) J. Vac. Sci. Technol. , vol.11 , pp. 551-518
    • Whetten, N.R.1
  • 251
    • 36049055027 scopus 로고
    • Exchange-collision technique for the rf spectroscopy of stored ions
    • F. G. Major, H. G. Dehmelt, Exchange-collision technique for the rf spectroscopy of stored ions, Phys. Rev. 170 (1968) 91-107.
    • (1968) Phys. Rev. , vol.170 , pp. 91-107
    • Major, F.G.1    Dehmelt, H.G.2
  • 252
    • 33646895942 scopus 로고
    • The three-dimensional quadrupole ion trap
    • P. H. Dawson, N. R. Whetten, The three-dimensional quadrupole ion trap, Naturwissenschaften 56 (1969) 109-112.
    • (1969) Naturwissenschaften , vol.56 , pp. 109-112
    • Dawson, P.H.1    Whetten, N.R.2
  • 253
    • 0018739415 scopus 로고
    • On the sensitivity of ion traps for spectroscopic applications
    • R. Blatt, U. Schmeling, G. Werth, On the sensitivity of ion traps for spectroscopic applications, Appl. Phys. 20 (1979) 295-298.
    • (1979) Appl. Phys. , vol.20 , pp. 295-298
    • Blatt, R.1    Schmeling, U.2    Werth, G.3
  • 254
    • 0016529844 scopus 로고
    • High-pressure characteristics of the quadrupole ion trap
    • P. H. Dawson, C. Lambert, High-pressure characteristics of the quadrupole ion trap, J. Vac. Sci. Techonol. 12 (1975) 941-942.
    • (1975) J. Vac. Sci. Techonol. , vol.12 , pp. 941-942
    • Dawson, P.H.1    Lambert, C.2
  • 256
    • 0000241070 scopus 로고
    • Ion-molecule reactions studies with a quadrupole ion storage trap
    • R. F. Bonner, G. Lawson, J. F. J. Todd, Ion-molecule reactions studies with a quadrupole ion storage trap, Int. J. Mass Spectrom. Ion Phys. 10 (1972) 197-203.
    • (1972) Int. J. Mass Spectrom. Ion Phys. , vol.10 , pp. 197-203
    • Bonner, R.F.1    Lawson, G.2    Todd, J.F.J.3
  • 257
    • 0348140299 scopus 로고
    • Effect of charge exchange reactions on the motion of ions in three-dimensional quadrupole electric fields
    • R. F. Bonner, R. E. March, J. Durup, Effect of charge exchange reactions on the motion of ions in three-dimensional quadrupole electric fields, Int. J. Mass Spectrom. Ion Phys. 22 (1976) 17-34.
    • (1976) Int. J. Mass Spectrom. Ion Phys. , vol.22 , pp. 17-34
    • Bonner, R.F.1    March, R.E.2    Durup, J.3
  • 259
    • 0008942375 scopus 로고
    • Method of mass analyzing a sample by use of a quadrupole ion trap
    • G. C. Stafford, P. E. Kelley, D. R. Stephens, Method of mass analyzing a sample by use of a quadrupole ion trap, U.S. Patent 4,540,884, Claim 17 (1985).
    • (1985) , pp. 17
    • Stafford, G.C.1    Kelley, P.E.2    Stephens, D.R.3
  • 260
    • 0006621939 scopus 로고
    • Effects of collisional cooling on detection
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 5
    • J. S. Brodbelt, Effects of collisional cooling on detection , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. 1, CRC Press, Boca Raton, FL, 1995, Chapter 5.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.1
    • Brodbelt, J.S.1
  • 261
    • 49249144998 scopus 로고
    • Trapping of ions injected from an external source into a three-dimensional RF quadrupole field
    • M. N. Kishore, P. K. Ghosh, Trapping of ions injected from an external source into a three-dimensional RF quadrupole field, Int. J. Mass Spectrom. Ion Phys. 29 (1979) 345-350.
    • (1979) Int. J. Mass Spectrom. Ion Phys. , vol.29 , pp. 345-350
    • Kishore, M.N.1    Ghosh, P.K.2
  • 262
    • 0010037515 scopus 로고
    • The quadrupole ion store (QUISTOR). Part XII. The trapping of ions injected from an external source: A description in terms of phase-space dynamics
    • J. F. J. Todd, D. A. Freer, R. M. Waldren, The quadrupole ion store (QUISTOR). Part XII. The trapping of ions injected from an external source: A description in terms of phase-space dynamics, Int. J. Mass Spectrom. Ion Phys. 36 (1980) 371-386.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.36 , pp. 371-386
    • Todd, J.F.J.1    Freer, D.A.2    Waldren, R.M.3
  • 263
    • 50849148663 scopus 로고
    • Confinement of pulse-injected external ions in a radiofrequency quadrupole ion trap
    • C.-S. O, H. A. Schuessler, Confinement of pulse-injected external ions in a radiofrequency quadrupole ion trap, Int. J. Mass Spectrom. Ion Phys. 40 (1981) 53-66.
    • (1981) Int. J. Mass Spectrom. Ion Phys , vol.40 , pp. 53-66
    • C.-S.O.1    Schuessler, H.A.2
  • 264
    • 14444273759 scopus 로고
    • Confinement of ions injected into a radiofrequency quadrupole ion trap: pulsed ion beams of different energies
    • C.-S. O, H. A. Schuessler, Confinement of ions injected into a radiofrequency quadrupole ion trap: pulsed ion beams of different energies, Int. J. Mass Spectrom. Ion Phys. 40 (1981) 67-75.
    • (1981) Int. J. Mass Spectrom. Ion Phys. , vol.40 , pp. 67-75
    • C.-S.O.1    Schuessler, H.A.2
  • 265
    • 14444270000 scopus 로고
    • Confinement of ions injected into a radiofrequency quadrupole ion trap: Energy-selective storage of pulse-injected ions
    • C.-S. O, H. A. Schuessler, Confinement of ions injected into a radiofrequency quadrupole ion trap: Energy-selective storage of pulse-injected ions, Int. J. Mass Spectrom. Ion Phys. 40 (1981) 77-86.
    • (1981) Int. J. Mass Spectrom. Ion Phys. , vol.40 , pp. 77-86
    • C.-S.O.1    Schuessler, H.A.2
  • 269
    • 23044447411 scopus 로고    scopus 로고
    • Fundamental studies of ion injection and trapping of electrosprayed ions on a quadrupole ion trap
    • S. T. Quarmby, R. A. Yost, Fundamental studies of ion injection and trapping of electrosprayed ions on a quadrupole ion trap, Int. J. Mass Spectrom. 190/191 (1999) 81-102.
    • (1999) Int. J. Mass Spectrom. , vol.190 , Issue.191 , pp. 81-102
    • Quarmby, S.T.1    Yost, R.A.2
  • 270
    • 0003660980 scopus 로고
    • Idaho National Engineering Laboratory Chemical Materials and Processes Department, Lockheed Idaho Technologies Company, Idaho Falls, ID
    • D. J. Dahl, SIMION 3D Version 6.0, Idaho National Engineering Laboratory Chemical Materials and Processes Department, Lockheed Idaho Technologies Company, Idaho Falls, ID, 1995.
    • (1995) SIMION 3D Version 6.0
    • Dahl, D.J.1
  • 271
    • 0019539434 scopus 로고
    • Confinement of ions created externally in a radio-frequency ion trap
    • C.-S. O, H. A. Scheussler, Confinement of ions created externally in a radio-frequency ion trap, J. Appl. Phys. 52 (1981) 1157-1166.
    • (1981) J. Appl. Phys. , vol.52 , pp. 1157-1166
    • C.-S.O.1    Scheussler, H.A.2
  • 274
    • 0028381419 scopus 로고
    • Filtered noise field signals for mass-selective accumulation of externally formed ions in a quadrupole ion trap
    • D. E. Goeringer, K. G. Asano, S. A. McLuckey, D. Hoekman, S. W. Stiller, Filtered noise field signals for mass-selective accumulation of externally formed ions in a quadrupole ion trap, Anal. Chem. 66 (1994) 313-318.
    • (1994) Anal. Chem. , vol.66 , pp. 313-318
    • Goeringer, D.E.1    Asano, K.G.2    McLuckey, S.A.3    Hoekman, D.4    Stiller, S.W.5
  • 275
    • 0003827618 scopus 로고
    • Practical ion trap technology:GC/MS and GC/MS/MS
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 4
    • N. A. Yates, M. M. Booth, J. L. Stephenson, Jr., R. A. Yost, Practical ion trap technology:GC/MS and GC/MS/MS , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. III, CRC Press, Boca Raton, FL, 1995, Chapter 4.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3
    • Yates, N.A.1    Booth, M.M.2    Stephenson, J.L.3    Yost, R.A.4
  • 276
    • 0023386279 scopus 로고
    • Instrumentation, applications and energy deposition in quadrupole ion trap MS/MS spectrometry
    • J. N. Louris, R. G. Cooks, J. E. P. Syka, P. E. Kelley, G. C. Stafford, Jr., J. F. J. Todd, Instrumentation, applications and energy deposition in quadrupole ion trap MS/MS spectrometry, Anal. Chem. 59 (1987) 1677-1685.
    • (1987) Anal. Chem. , vol.59 , pp. 1677-1685
    • Louris, J.N.1    Cooks, R.G.2    Syka, J.E.P.3    Kelley, P.E.4    Stafford, G.C.5    Todd, J.F.J.6
  • 277
    • 0141785109 scopus 로고    scopus 로고
    • The use of static pressures of heavy gases within a quadrupole ion trap
    • R. M. Danell, A. S. Danell, G. L. Glish, R. W. Vachet, The use of static pressures of heavy gases within a quadrupole ion trap, J. Am. Soc. Mass Spectrom. 14 (2003) 1099-1109.
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , pp. 1099-1109
    • Danell, R.M.1    Danell, A.S.2    Glish, G.L.3    Vachet, R.W.4
  • 279
    • 84989064859 scopus 로고
    • Boundary effects and collisional activation in a quadrupole ion trap
    • C. Paradisi, J. F. J. Todd, P. Traldi, U. Vettori, Boundary effects and collisional activation in a quadrupole ion trap, Org. Mass Spectrom. 27 (1992) 251-254.
    • (1992) Org. Mass Spectrom. , vol.27 , pp. 251-254
    • Paradisi, C.1    Todd, J.F.J.2    Traldi, P.3    Vettori, U.4
  • 281
    • 0000598484 scopus 로고
    • Surface-induced dissociation of molecular ions in a quadrupole ion trap mass spectrometer
    • S. A. Lammert, R. G. Cooks, Surface-induced dissociation of molecular ions in a quadrupole ion trap mass spectrometer, J. Am. Soc. Mass Spectrom. 2 (1991) 487-491.
    • (1991) J. Am. Soc. Mass Spectrom. , vol.2 , pp. 487-491
    • Lammert, S.A.1    Cooks, R.G.2
  • 298
    • 0003660980 scopus 로고
    • Idaho National Engineering Laboratory Chemical Materials and Processes Department, Lockheed Idaho Technologies Company, Idaho Falls, ID
    • D. A. Dahl, SIMION 3D Version 6.0 User's Manual, Idaho National Engineering Laboratory Chemical Materials and Processes Department, Lockheed Idaho Technologies Company, Idaho Falls, ID, 1995.
    • (1995) SIMION 3D Version 6.0 User's Manual
    • Dahl, D.A.1
  • 324
    • 84949482340 scopus 로고
    • Trent University, Peterborough, ON
    • M. Ho, Honours Thesis, Trent University, Peterborough, ON, 1983.
    • (1983) Honours Thesis
    • Ho, M.1
  • 326
    • 84949516281 scopus 로고    scopus 로고
    • personal communication
    • R. G. Cooks, personal communication, 1998.
    • (1998)
    • Cooks, R.G.1
  • 328
    • 0002884354 scopus 로고
    • Injection of mass-selected ions into the radiofrequency ion trap
    • R. E. March and J. F. J. Todd (Eds.), CRC Press: Boca Raton, FL, Chapter 2
    • P. Kofel, Injection of mass-selected ions into the radiofrequency ion trap , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. II, CRC Press: Boca Raton, FL, 1995, Chapter 2.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.2
    • Kofel, P.1
  • 330
    • 84949488262 scopus 로고
    • W. M. Brubaker, U.S. Patent 3,129,327 (1964).
    • (1964)
    • Brubaker, W.M.1
  • 333
    • 0038166642 scopus 로고
    • Apparatus for Separating Charged Particles of Different Specific charges
    • U.S. Patent 2,939,952 (June 7
    • W. Paul, H. Steinwedel, Apparatus for Separating Charged Particles of Different Specific charges, German Patent 944,900 (1956); U.S. Patent 2,939,952 (June 7, 1960).
    • (1960)
    • Paul, W.1    Steinwedel, H.2
  • 334
    • 0006103821 scopus 로고
    • U. von Zahn, S. Gebauer,W. Paul, paper presented at the Tenth Annual Conference on Mass Spectrometry, New Orleans, 1962
    • U. von Zahn, Z. Phys. 168 (1962) 129; U. von Zahn, S. Gebauer,W. Paul, paper presented at the Tenth Annual Conference on Mass Spectrometry, New Orleans, 1962.
    • (1962) Z. Phys. , vol.168 , pp. 129
    • von Zahn, U.1
  • 336
    • 0003843122 scopus 로고
    • Elsevier, Amsterdam, Reprinted as an "American Vacuum Society Classic" by the American Institute of Physics (ISBN 1563964554)
    • P. H. Dawson, Quadrupole Mass Spectrometry and Its Applications, Elsevier, Amsterdam, 1976. Reprinted as an "American Vacuum Society Classic" by the American Institute of Physics (ISBN 1563964554).
    • (1976) Quadrupole Mass Spectrometry and Its Applications
    • Dawson, P.H.1
  • 347
    • 84949527831 scopus 로고
    • J. D. Prestage, U.S. Patent 5,420,549 (1995).
    • (1995)
    • Prestage, J.D.1
  • 355
    • 84949521123 scopus 로고    scopus 로고
    • J. W. Hager, U.S. Patent 6,177,668 (2001).
    • (2001)
    • Hager, J.W.1
  • 356
    • 0036199431 scopus 로고    scopus 로고
    • A new linear ion trap mass spectrometer
    • J. W. Hager, A new linear ion trap mass spectrometer, Rapid Commun. Mass Spectrom. 16 (2002) 512.
    • (2002) Rapid Commun. Mass Spectrom , vol.16 , pp. 512
    • Hager, J.W.1
  • 363
    • 0038219393 scopus 로고    scopus 로고
    • Do space charge effects limit LC quadrupole ion trap performance?
    • Sanibel Island, FL, January 25-28
    • J. C. Schwartz, Do space charge effects limit LC quadrupole ion trap performance? 9th Sanibel Conference on Mass Spectrometry, Sanibel Island, FL, January 25-28, 1997, p. 61.
    • (1997) 9th Sanibel Conference on Mass Spectrometry , pp. 61
    • Schwartz, J.C.1
  • 364
    • 84949498613 scopus 로고    scopus 로고
    • J. W. Hager, U.S. Patent 6,627,876 (2003).
    • (2003)
    • Hager, J.W.1
  • 369
    • 0027832041 scopus 로고
    • POISSON/SUPERFISH on PC compatibles
    • May 17-20, Edited by S. T. Corneliussen, IEEE, New York, 1993
    • J. H. Billen, L. M. Young, POISSON/SUPERFISH on PC compatibles, Proc. of the 1993 Particle Accelerator Conference, May 17-20, 1993, Edited by S. T. Corneliussen, IEEE, New York, 1993, pp. 790-792.
    • (1993) Proc. of the 1993 Particle Accelerator Conference , pp. 790-792
    • Billen, J.H.1    Young, L.M.2
  • 374
    • 0037543895 scopus 로고    scopus 로고
    • The dependence of RF ion trap mass spectrometer performance on electrode geometry and collisional processes, dissertation
    • Justus-Liebig Universitaet Giessen, Giessen
    • W. R. Plass, The dependence of RF ion trap mass spectrometer performance on electrode geometry and collisional processes, dissertation, Justus-Liebig Universitaet Giessen, Giessen, 2001.
    • (2001)
    • Plass, W.R.1
  • 377
    • 84949516580 scopus 로고    scopus 로고
    • paper presented at the Forty-Ninth Annual Conference of the American Society for Mass Spectrometry and Allied Topics, Chicago, IL, May 27-31
    • K. Giles, R. H. Bateman, paper presented at the Forty-Ninth Annual Conference of the American Society for Mass Spectrometry and Allied Topics, Chicago, IL, May 27-31, 2001.
    • (2001)
    • Giles, K.1    Bateman, R.H.2
  • 381
    • 0001546739 scopus 로고
    • The quadrupole ion store (QUISTOR) as a novel source for a mass spectrometer
    • G. Lawson, R. F. Bonner, J. F. J. Todd, The quadrupole ion store (QUISTOR) as a novel source for a mass spectrometer, J. Phys. E 6 (1973) 357-362.
    • (1973) J. Phys. E , vol.6 , pp. 357-362
    • Lawson, G.1    Bonner, R.F.2    Todd, J.F.J.3
  • 394
    • 0000294749 scopus 로고
    • Simple electrodes for quadrupole ion traps
    • E. Beaty, Simple electrodes for quadrupole ion traps, J. Appl. Phys. 61 (1987) 2118-2122.
    • (1987) J. Appl. Phys. , vol.61 , pp. 2118-2122
    • Beaty, E.1
  • 395
    • 0007319038 scopus 로고
    • Ion storage in a radio-frequency trap with semi-spherical electrodes
    • C.-S. O, H. A. Schuessler, Ion storage in a radio-frequency trap with semi-spherical electrodes, Int. J. Mass Spectrom. Ion Phys. 35 (1980) 305-317.
    • (1980) Int. J. Mass Spectrom. Ion Phys. , vol.35 , pp. 305-317
    • C.-S.O.1    Schuessler, H.A.2
  • 396
    • 0346303593 scopus 로고
    • Stored ion spectroscopy
    • F. T. Arecchi, F. Strumia, H. Walther (Eds.), Plenum, New York
    • H. G. Dehmelt, Stored ion spectroscopy , in F. T. Arecchi, F. Strumia, H. Walther (Eds.), Advances in Laser Spectroscopy, Plenum, New York, 1983, p. 153.
    • (1983) Advances in Laser Spectroscopy , pp. 153
    • Dehmelt, H.G.1
  • 399
    • 0001562484 scopus 로고
    • Calculated electrostatic properties of ion traps
    • E. C. Beaty, Calculated electrostatic properties of ion traps, Phys. Rev. A Gen. Phys. 33(6) (1986) 3645-3655.
    • (1986) Phys. Rev. A Gen. Phys. , vol.33 , Issue.6 , pp. 3645-3655
    • Beaty, E.C.1
  • 417
    • 0004187776 scopus 로고    scopus 로고
    • NIST Chemistry WebBook, W. G. Mallard and P. J. Lindstrom (Eds.), NIST Standard Reference Database Number 69, National Institute of Standards and Technology, Gaithersburg, MD, February, 1,2-Ethanediol
    • S. E. Stein, IR and Mass Spectra. In NIST Chemistry WebBook, W. G. Mallard and P. J. Lindstrom (Eds.), NIST Standard Reference Database Number 69, National Institute of Standards and Technology, Gaithersburg, MD (February) 2000, 1,2-Ethanediol (http://webbook.nist.gov).
    • (2000) IR and Mass Spectra
    • Stein, S.E.1
  • 447
    • 0038166642 scopus 로고
    • Apparatus for separating charged particles of different specific charge
    • U.S. Patent 2,939,952 (June 7, 1960)
    • W. Paul, H. Steinwedel, Apparatus for separating charged particles of different specific charge, German Patent 944,900 (1956); U.S. Patent 2,939,952 (June 7, 1960).
    • (1956)
    • Paul, W.1    Steinwedel, H.2
  • 448
    • 0001700222 scopus 로고
    • Commercialization of the quadrupole ion trap. In R. E. March and J. F. J. Todd (Eds.)
    • Chapter 4, CRC Press, Boca Raton, FL
    • J. E. P. Syka, Commercialization of the quadrupole ion trap. In R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. I, Chapter 4, CRC Press, Boca Raton, FL, 1995.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.1
    • Syka, J.E.P.1
  • 449
    • 33646883729 scopus 로고
    • The geometry of the Finnigan ion trap: History and theory
    • Asilomar Conference Grounds, Pacific Grove, CA, September
    • J. E. P. Syka, The geometry of the Finnigan ion trap: History and theory, 9th Asilomar Conference on Mass Spectrometry, Asilomar Conference Grounds, Pacific Grove, CA, September 1992.
    • (1992) 9th Asilomar Conference on Mass Spectrometry
    • Syka, J.E.P.1
  • 454
    • 0003827618 scopus 로고
    • Practical ion trap technology:GC/MS and GC/MS/MS
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 4
    • N. A. Yates, M. M. Booth, J. L. Stephenson, Jr., R. A. Yost, Practical ion trap technology:GC/MS and GC/MS/MS , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. III, CRC Press, Boca Raton, FL, 1995, Chapter 4.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3
    • Yates, N.A.1    Booth, M.M.2    Stephenson, J.L.3    Yost, R.A.4
  • 458
    • 84949506269 scopus 로고
    • September 10, Canadian Patent 1,207,918 (July 15, 1986)
    • P. E. Kelley, G. C. Stafford, Jr., D. R. Stevens, U.S. Patent 4,540,884 (September 10, 1985); Canadian Patent 1,207,918 (July 15, 1986).
    • (1985)
    • Kelley, P.E.1    Stafford, G.C.2    Stevens, D.R.3
  • 460
    • 33646890036 scopus 로고
    • Ion trap theory, design, and operation
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 1
    • J. F. J. Todd, Ion trap theory, design, and operation , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. III, CRC Press, Boca Raton, FL, 1995, Chapter 1, p. 16.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3 , pp. 16
    • Todd, J.F.J.1
  • 461
    • 0006424607 scopus 로고
    • A commercial ion trap (ITD) modified by monopolar excitation for resonant ejection and extended mass range
    • Washington, DC, May 31-June 5
    • X. Wang, D. K. Bohme, R. E. March, A commercial ion trap (ITD) modified by monopolar excitation for resonant ejection and extended mass range. Proc. 40th ASMS Conf. on Mass Spectrometry and Allied Topics, Washington, DC, May 31-June 5, 1992, p. 230.
    • (1992) Proc. 40th ASMS Conf. on Mass Spectrometry and Allied Topics , pp. 230
    • Wang, X.1    Bohme, D.K.2    March, R.E.3
  • 484
    • 0000708444 scopus 로고    scopus 로고
    • A new ion ejection method employing an asymmetric trapping field to improve the mass scanning performance of an electrodynamic ion trap
    • M. Splendore, E. Marquette, J. Oppenheimer, C. Huston, G. Wells, A new ion ejection method employing an asymmetric trapping field to improve the mass scanning performance of an electrodynamic ion trap, Int. J. Mass Spectrom. 190/191 (1999) 129-143.
    • (1999) Int. J. Mass Spectrom. , vol.190 , Issue.191 , pp. 129-143
    • Splendore, M.1    Marquette, E.2    Oppenheimer, J.3    Huston, C.4    Wells, G.5
  • 487
    • 84914620834 scopus 로고
    • Purdue University, West Lafayette, IN
    • R. K. Julian, Ph.D. Thesis, Purdue University, West Lafayette, IN, 1993.
    • (1993) Ph.D. Thesis
    • Julian, R.K.1
  • 488
    • 84949527290 scopus 로고
    • J. Franzen, U.S. Patent 5,170,054 (1992).
    • (1992)
    • Franzen, J.1
  • 499
    • 0007648920 scopus 로고
    • Organic trace analysis using direct probe sample introduction and high resolution mass spectrometry
    • M. L. Gross (Ed.), American Chemical Society, Washington, DC
    • W. F. Haddon, Organic trace analysis using direct probe sample introduction and high resolution mass spectrometry , in M. L. Gross (Ed.), High Performance Mass Spectrometry, American Chemical Society, Washington, DC, 1978, pp. 97-119.
    • (1978) High Performance Mass Spectrometry , pp. 97-119
    • Haddon, W.F.1
  • 518
    • 0346660880 scopus 로고
    • Computer simulation of ion trajectories in a quadrupole ion trap mass spectrometer
    • San Francisco, CA, June 5-10
    • R. E. Pedder, R. A. Yost, Computer simulation of ion trajectories in a quadrupole ion trap mass spectrometer. Proc. 36th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics, San Francisco, CA, June 5-10, 1988, pp. 632-633.
    • (1988) Proc. 36th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics , pp. 632-633
    • Pedder, R.E.1    Yost, R.A.2
  • 520
    • 0002884354 scopus 로고
    • Injection of mass-selected ions into the radiofrequency ion trap
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 2
    • P. Kofel, Injection of mass-selected ions into the radiofrequency ion trap , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. II, CRC Press, Boca Raton, FL, 1995, Chapter 2.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.2
    • Kofel, P.1
  • 523
    • 0007541275 scopus 로고
    • Liquid chromatography/mass spectrometry
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 5
    • B. L. Kleintop, D. M. Eades, R. A. Yost, Liquid chromatography/mass spectrometry , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. III, CRC Press, Boca Raton, FL, 1995, Chapter 5.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3
    • Kleintop, B.L.1    Eades, D.M.2    Yost, R.A.3
  • 524
    • 0344777086 scopus 로고
    • Ion spray liquid chromatography/mass spectrometry and capillary electrophoresis/mass spectrometry on a modified benchtop ion trap mass spectrometer
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 6
    • A. Mordehai, H. K. Lim, J. D. Henion, Ion spray liquid chromatography/mass spectrometry and capillary electrophoresis/mass spectrometry on a modified benchtop ion trap mass spectrometer , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. III, CRC Press, Boca Raton, FL, 1995, Chapter 6.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3
    • Mordehai, A.1    Lim, H.K.2    Henion, J.D.3
  • 525
    • 0007499811 scopus 로고
    • Electrospray/ion trap mass spectrometry: Applications to trace analysis
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 14
    • H.-Y. Lin, R. D. Voyksner, Electrospray/ion trap mass spectrometry: Applications to trace analysis , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. III, CRC Press, Boca Raton, FL, 1995, Chapter 14.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.3
    • Lin, H.-Y.1    Voyksner, R.D.2
  • 559
    • 0007415073 scopus 로고
    • Computer programs for interpretation of mass spectra of multiply charged ions of mixtures
    • Tucson, AZ, June 3-8
    • J. X. G. Zhou, I. Jardine, Computer programs for interpretation of mass spectra of multiply charged ions of mixtures. Proc. 38th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics, Tucson, AZ, June 3-8, 1990, pp. 134-135.
    • (1990) Proc. 38th Ann. ASMS Conf. on Mass Spectrometry and Allied Topics , pp. 134-135
    • Zhou, J.X.G.1    Jardine, I.2
  • 563
    • 0002785362 scopus 로고
    • High mass, high resolution mass spectrometry
    • R. E. March and J. F. J. Todd (Eds.), CRC Press, Boca Raton, FL, Chapter 1
    • J. D. Williams, K. A. Cox, J. C. Schwartz, High mass, high resolution mass spectrometry , in R. E. March and J. F. J. Todd (Eds.), Practical Aspects of Ion Trap Mass Spectrometry, Vol. II, CRC Press, Boca Raton, FL, 1995, Chapter 1.
    • (1995) Practical Aspects of Ion Trap Mass Spectrometry , vol.2
    • Williams, J.D.1    Cox, K.A.2    Schwartz, J.C.3
  • 570
    • 84949502789 scopus 로고    scopus 로고
    • Contract DAAA15-87-C0008 awarded to Teledyne CME for the U.S. Army ERDEC (Aberdeen Proving Ground)
    • Chemical- Biological Mass Spectrometer, CBMS
    • Contract DAAA15-87-C0008 awarded to Teledyne CME for the U.S. Army ERDEC (Aberdeen Proving Ground), Chemical- Biological Mass Spectrometer, CBMS.
  • 581
    • 84949518199 scopus 로고
    • filed March 8
    • J. Hiller, UK Patent 1,346,393, filed March 8, 1971.
    • (1971)
    • Hiller, J.1
  • 584
    • 84949525493 scopus 로고
    • University of New South Wales, Sydney
    • J. A. Richards, Ph.D. Thesis, University of New South Wales, Sydney, 1972.
    • (1972)
    • Richards, J.A.1    Thesis, P.D.2
  • 599
    • 37049172817 scopus 로고
    • The thermodynamic properties of isotopic substances
    • H. C. Urey, The thermodynamic properties of isotopic substances, J. Chem. Soc. (1947) 562-581.
    • (1947) J. Chem. Soc. , pp. 562-581
    • Urey, H.C.1
  • 600
    • 84949492010 scopus 로고    scopus 로고
    • The use of microfabricated field emitter arrays in a high precision mass spectrometer for the Rosetta missions
    • paper presented at the Third Round Table on Micro/Nano Technologies for Space, ESTEC, May 15-19
    • B. J. Kent, E. Huq, J. N. Dominey, A. D. Morse, N. Waltham, The use of microfabricated field emitter arrays in a high precision mass spectrometer for the Rosetta missions, paper presented at the Third Round Table on Micro/Nano Technologies for Space, ESTEC, May 15-19, 2000.
    • (2000)
    • Kent, B.J.1    Huq, E.2    Dominey, J.N.3    Morse, A.D.4    Waltham, N.5
  • 601
    • 33646865085 scopus 로고    scopus 로고
    • Development of a miniature quadrupole ion trap mass spectrometer for the determination of stable isotope ratios
    • E. J. Karjalainen, A. E. Hesso, J. E. Jalonen, U. P. Karjalainen (Eds), Elsevier Science, Amsterdam
    • S. J. Barber, A. D. Morse, I. P. Wright, B. J. Kent, N. R. Waltham, J. F. J. Todd, C. T. Pillinger, Development of a miniature quadrupole ion trap mass spectrometer for the determination of stable isotope ratios , in E. J. Karjalainen, A. E. Hesso, J. E. Jalonen, U. P. Karjalainen (Eds), Advances in Mass Spectrometry, Vol. 14, Elsevier Science, Amsterdam, 1998.
    • (1998) Advances in Mass Spectrometry , vol.14
    • Barber, S.J.1    Morse, A.D.2    Wright, I.P.3    Kent, B.J.4    Waltham, N.R.5    Todd, J.F.J.6    Pillinger, C.T.7
  • 602
    • 33646860373 scopus 로고    scopus 로고
    • Development of a quadrupole ion trap mass spectrometer for the determination of stable isotope ratios: Application to a space-flight opportunity
    • Ph.D. Thesis, Open University, Milton Keynes UK
    • S. J. Barber, Development of a quadrupole ion trap mass spectrometer for the determination of stable isotope ratios: Application to a space-flight opportunity, Ph.D. Thesis, Open University, Milton Keynes UK, 1998.
    • (1998)
    • Barber, S.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.