메뉴 건너뛰기




Volumn 48, Issue 8, 2013, Pages 937-944

The coupling effects of hexapole and octopole fields in quadrupole ion traps: A theoretical study

Author keywords

coupling effects; harmonic balance method; hexapole; octopole; quadrupole ion trap

Indexed keywords

COUPLING EFFECT; HARMONIC BALANCE METHOD; HEXAPOLE; OCTOPOLE; QUADRUPOLE ION TRAPS;

EID: 84881108063     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.3239     Document Type: Article
Times cited : (43)

References (51)
  • 1
    • 0036199431 scopus 로고    scopus 로고
    • A new linear ion trap mass spectrometer
    • J. W. Hager,. A new linear ion trap mass spectrometer. Rapid Commun. Mass Spectrom. 2002, 16 (6), 512-526.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , Issue.6 , pp. 512-526
    • Hager, J.W.1
  • 3
    • 12444305375 scopus 로고    scopus 로고
    • Linear ion traps in mass spectrometry
    • D. J. Douglas, A. J. Frank, D. Mao,. Linear ion traps in mass spectrometry. Mass Spectrom. Rev. 2004, 24 (1), 1-29.
    • (2004) Mass Spectrom. Rev. , vol.24 , Issue.1 , pp. 1-29
    • Douglas, D.J.1    Frank, A.J.2    Mao, D.3
  • 8
    • 0035891892 scopus 로고    scopus 로고
    • Design, optimization and initial performance of a toroidal rf ion trap mass spectrometer
    • S. A. Lammert, W. R. Plass, C. V. Thompson, M. B. Wise,. Design, optimization and initial performance of a toroidal rf ion trap mass spectrometer. Int. J. Mass Spectrom. 2001, 212 (1), 25-40.
    • (2001) Int. J. Mass Spectrom. , vol.212 , Issue.1 , pp. 25-40
    • Lammert, S.A.1    Plass, W.R.2    Thompson, C.V.3    Wise, M.B.4
  • 9
    • 0001562484 scopus 로고
    • Calculated electrostatic properties of ion traps
    • E. C. Beaty, Calculated electrostatic properties of ion traps. Phys. Rev. A 1986, 33 (6), 3645.
    • (1986) Phys. Rev. A , vol.33 , Issue.6 , pp. 3645
    • Beaty, E.C.1
  • 10
    • 0000871860 scopus 로고
    • Computed energy and spatial statistical properties of stored ions cooled by a buffer gas
    • F. Vedel, J. Andre, M. Vedel, G. Brincourt,. Computed energy and spatial statistical properties of stored ions cooled by a buffer gas. Phys. Rev. A 1983, 27 (5), 2321.
    • (1983) Phys. Rev. A , vol.27 , Issue.5 , pp. 2321
    • Vedel, F.1    Andre, J.2    Vedel, M.3    Brincourt, G.4
  • 11
    • 0032232010 scopus 로고    scopus 로고
    • Comparison of equilibrium ion density distribution and trapping force in Penning, Paul, and combined ion traps
    • G. Z. Li, S. Guan, A. G. Marshall,. Comparison of equilibrium ion density distribution and trapping force in Penning, Paul, and combined ion traps. J. Am. Soc. Mass Spectrom. 1998, 9 (5), 473-481.
    • (1998) J. Am. Soc. Mass Spectrom. , vol.9 , Issue.5 , pp. 473-481
    • Li, G.Z.1    Guan, S.2    Marshall, A.G.3
  • 12
    • 62149147187 scopus 로고    scopus 로고
    • Characterization of electrode surface roughness and its impact on ion trap mass analysis
    • W. Xu, W. J. Chappell, R. G. Cooks, Z. Ouyang,. Characterization of electrode surface roughness and its impact on ion trap mass analysis. J. Mass Spectrom. 2008, 44 (3), 353-360.
    • (2008) J. Mass Spectrom. , vol.44 , Issue.3 , pp. 353-360
    • Xu, W.1    Chappell, W.J.2    Cooks, R.G.3    Ouyang, Z.4
  • 13
    • 4043060624 scopus 로고    scopus 로고
    • Rectilinear ion trap: Concepts, calculations, and analytical performance of a new mass analyzer
    • Z. Ouyang, G. Wu, Y. Song,;, H. Li, W. R. Plass, R. G. Cooks,. Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer. Anal. Chem. 2004, 76 (16), 4595-4605.
    • (2004) Anal. Chem. , vol.76 , Issue.16 , pp. 4595-4605
    • Ouyang, Z.1    Wu, G.2    Song, Y.3    Li, H.4    Plass, W.R.5    Cooks, R.G.6
  • 14
    • 0001388601 scopus 로고    scopus 로고
    • Resonance ejection from the Paul trap: A theoretical treatment incorporating a weak octapole field
    • A. A. Makarov,. Resonance ejection from the Paul trap: A theoretical treatment incorporating a weak octapole field. Anal. Chem. 1996, 68 (23), 4257-4263.
    • (1996) Anal. Chem. , vol.68 , Issue.23 , pp. 4257-4263
    • Makarov, A.A.1
  • 15
    • 84862529957 scopus 로고    scopus 로고
    • Dipolar DC collisional activation in a "stretched" 3-D ion trap: The effect of higher order fields on RF-heating
    • B. M. Prentice, S. A. McLuckey,. Dipolar DC collisional activation in a "stretched" 3-D ion trap: the effect of higher order fields on RF-heating. J. Am. Soc. Mass Spectrom. 2012, 1-9.
    • (2012) J. Am. Soc. Mass Spectrom. , pp. 1-9
    • Prentice, B.M.1    McLuckey, S.A.2
  • 16
    • 77956419088 scopus 로고    scopus 로고
    • Multipole expansion in quadrupolar devices comprised of planar electrode arrays
    • D. E. Austin, B. J. Hansen, Y. Peng, Z. Zhang,. Multipole expansion in quadrupolar devices comprised of planar electrode arrays. Int. J. Mass Spectrom. 2010, 295 (3), 153-158.
    • (2010) Int. J. Mass Spectrom. , vol.295 , Issue.3 , pp. 153-158
    • Austin, D.E.1    Hansen, B.J.2    Peng, Y.3    Zhang, Z.4
  • 18
    • 0002832383 scopus 로고
    • Non-linear resonances in quadrupole mass spectrometers due to imperfect fields I. The quadrupole ion trap
    • P. Dawson, N. Whetten,. Non-linear resonances in quadrupole mass spectrometers due to imperfect fields I. The quadrupole ion trap. Int. J. Mass Spectrom. Ion Phys. 1969, 2 (1), 45-59.
    • (1969) Int. J. Mass Spectrom. Ion Phys. , vol.2 , Issue.1 , pp. 45-59
    • Dawson, P.1    Whetten, N.2
  • 19
    • 0141998373 scopus 로고
    • Non-linear resonances in quadrupole mass spectrometers due to imperfect fields: II. The quadrupole mass filter and the monopole mass spectrometer
    • P. Dawson, N. Whetten,. Non-linear resonances in quadrupole mass spectrometers due to imperfect fields: II. The quadrupole mass filter and the monopole mass spectrometer. Int. J. Mass Spectrom. Ion Phys. 1969, 3 (1), 1-12.
    • (1969) Int. J. Mass Spectrom. Ion Phys. , vol.3 , Issue.1 , pp. 1-12
    • Dawson, P.1    Whetten, N.2
  • 20
    • 0037212641 scopus 로고    scopus 로고
    • Chemical mass shifts in quadrupole ion traps as analytical characteristics of nitro-aromatic compounds
    • H. Li, Y. Peng, W. R. Plass, R. G. Cooks,. Chemical mass shifts in quadrupole ion traps as analytical characteristics of nitro-aromatic compounds. Int. J. Mass Spectrom. 2003, 222 (1), 481-491.
    • (2003) Int. J. Mass Spectrom. , vol.222 , Issue.1 , pp. 481-491
    • Li, H.1    Peng, Y.2    Plass, W.R.3    Cooks, R.G.4
  • 21
    • 0036772560 scopus 로고    scopus 로고
    • Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap
    • H. Li, W. R. Plass, G. E. Patterson, R. G. Cooks,. Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap. J. Mass Spectrom. 2002, 37 (10), 1051-1058.
    • (2002) J. Mass Spectrom. , vol.37 , Issue.10 , pp. 1051-1058
    • Li, H.1    Plass, W.R.2    Patterson, G.E.3    Cooks, R.G.4
  • 22
    • 0034233904 scopus 로고    scopus 로고
    • Control of chemical mass shifts in the quadrupole ion trap through selection of resonance ejection working point and rf scan direction
    • J. M. Wells, W. R. Plass, R. G. Cooks,. Control of chemical mass shifts in the quadrupole ion trap through selection of resonance ejection working point and rf scan direction. Anal. Chem. 2000, 72 (13), 2677-2683.
    • (2000) Anal. Chem. , vol.72 , Issue.13 , pp. 2677-2683
    • Wells, J.M.1    Plass, W.R.2    Cooks, R.G.3
  • 23
  • 24
    • 0141989738 scopus 로고    scopus 로고
    • Linear quadrupoles with added octopole fields
    • M. Sudakov, D. Douglas,. Linear quadrupoles with added octopole fields. Rapid Commun. Mass Spectrom. 2003, 17 (20), 2290-2294.
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , Issue.20 , pp. 2290-2294
    • Sudakov, M.1    Douglas, D.2
  • 25
    • 78650518135 scopus 로고    scopus 로고
    • Effects of higher-order multipoles on the performance of a two-plate quadrupole ion trap mass analyzer
    • Z. Zhang, H. Quist, Y. Peng, B. J. Hansen, J. Wang, A. R. Hawkins, D. E. Austin,. Effects of higher-order multipoles on the performance of a two-plate quadrupole ion trap mass analyzer. Int. J. Mass Spectrom. 2011, 299 (2), 151-157.
    • (2011) Int. J. Mass Spectrom. , vol.299 , Issue.2 , pp. 151-157
    • Zhang, Z.1    Quist, H.2    Peng, Y.3    Hansen, B.J.4    Wang, J.5    Hawkins, A.R.6    Austin, D.E.7
  • 26
    • 0036013640 scopus 로고    scopus 로고
    • A theoretical investigation of the kinetic energy of ions trapped in a radio-frequency hexapole ion trap
    • L. A. McDonnell, A. E. Giannakopulos, P. J. Derrick, Y. O. Tsybin, P. Hakansson,. A theoretical investigation of the kinetic energy of ions trapped in a radio-frequency hexapole ion trap. Eur. J. Mass Spectrom. 2002, 8 (2), 181-189.
    • (2002) Eur. J. Mass Spectrom. , vol.8 , Issue.2 , pp. 181-189
    • McDonnell, L.A.1    Giannakopulos, A.E.2    Derrick, P.J.3    Tsybin, Y.O.4    Hakansson, P.5
  • 27
    • 41049098024 scopus 로고    scopus 로고
    • Quadrupole excitation of ions in linear quadrupole ion traps with added octopole fields
    • X. Z. Zhao, O. Granot, D. Douglas,. Quadrupole excitation of ions in linear quadrupole ion traps with added octopole fields. J. Am. Soc. Mass Spectrom. 2008, 19 (4), 510-519.
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , Issue.4 , pp. 510-519
    • Zhao, X.Z.1    Granot, O.2    Douglas, D.3
  • 28
    • 15944372213 scopus 로고    scopus 로고
    • Geometry optimization for the cylindrical ion trap: Field calculations, simulations and experiments
    • G. Wu, R. G. Cooks, Z. Ouyang,. Geometry optimization for the cylindrical ion trap: field calculations, simulations and experiments. Int. J. Mass Spectrom. 2005, 241 (2), 119-132.
    • (2005) Int. J. Mass Spectrom. , vol.241 , Issue.2 , pp. 119-132
    • Wu, G.1    Cooks, R.G.2    Ouyang, Z.3
  • 31
    • 39149090033 scopus 로고    scopus 로고
    • Mass selective axial ion ejection from linear quadrupoles with added octopole fields
    • A. Moradian, D. Douglas,. Mass selective axial ion ejection from linear quadrupoles with added octopole fields. J. Am. Soc. Mass Spectrom. 2008, 19 (2), 270-280.
    • (2008) J. Am. Soc. Mass Spectrom. , vol.19 , Issue.2 , pp. 270-280
    • Moradian, A.1    Douglas, D.2
  • 32
    • 0141450231 scopus 로고    scopus 로고
    • Mass selective axial ion ejection from a linear quadrupole ion trap
    • F. Londry, J. W. Hager,. Mass selective axial ion ejection from a linear quadrupole ion trap. J. Am. Soc. Mass Spectrom. 2003, 14 (10), 1130-1147.
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , Issue.10 , pp. 1130-1147
    • Londry, F.1    Hager, J.W.2
  • 34
    • 47549086496 scopus 로고    scopus 로고
    • Dipole excitation of ions in linear radio frequency quadrupole ion traps with added multipole fields
    • X. Z. Zhao, D. Douglas,. Dipole excitation of ions in linear radio frequency quadrupole ion traps with added multipole fields. Int. J. Mass Spectrom. 2008, 275 (1), 91-103.
    • (2008) Int. J. Mass Spectrom. , vol.275 , Issue.1 , pp. 91-103
    • Zhao, X.Z.1    Douglas, D.2
  • 35
    • 84865448533 scopus 로고    scopus 로고
    • Perturbation theory for ion motion in quadrupole radio frequency field
    • S. Mikhail, A. Maria,. Perturbation theory for ion motion in quadrupole radio frequency field. Int. J. Mass Spectrom. 2012, 325-327, 58-66.
    • (2012) Int. J. Mass Spectrom. , vol.325-327 , pp. 58-66
    • Mikhail, S.1    Maria, A.2
  • 36
    • 82755189389 scopus 로고    scopus 로고
    • Calculation of secular axial frequencies in a nonlinear ion trap with hexapole, octopole and decapole superpositions by a modified Lindstedt-Poincare method
    • A. Doroudi, A. R. Asl,. Calculation of secular axial frequencies in a nonlinear ion trap with hexapole, octopole and decapole superpositions by a modified Lindstedt-Poincare method. Int. J. Mass Spectrom. 2011, 309, 104-108.
    • (2011) Int. J. Mass Spectrom. , vol.309 , pp. 104-108
    • Doroudi, A.1    Asl, A.R.2
  • 37
    • 0000700670 scopus 로고
    • The non-linear resonance ion trap. Part 2. A general theoretical analysis
    • Y. Wang, J. Franzen, K. Wanczek,. The non-linear resonance ion trap. Part 2. A general theoretical analysis. Int. j. mass spectrom. ion processes 1993, 124 (2), 125-144.
    • (1993) Int. J. Mass Spectrom. Ion Processes , vol.124 , Issue.2 , pp. 125-144
    • Wang, Y.1    Franzen, J.2    Wanczek, K.3
  • 38
    • 77956859716 scopus 로고
    • Radiofrequency spectroscopy of stored ions I: Storage
    • H. Dehmelt,. Radiofrequency spectroscopy of stored ions I: Storage. Adv. At. Mol. Phys. 1967, 3, 53-72.
    • (1967) Adv. At. Mol. Phys. , vol.3 , pp. 53-72
    • Dehmelt, H.1
  • 39
    • 71449112431 scopus 로고    scopus 로고
    • Calculation of coupled secular oscillation frequencies and axial secular frequency in a nonlinear ion trap by a homotopy method
    • A. Doroudi, Calculation of coupled secular oscillation frequencies and axial secular frequency in a nonlinear ion trap by a homotopy method. Phys. Rev. E 2009, 80 (5), 056603.
    • (2009) Phys. Rev. e , vol.80 , Issue.5 , pp. 056603
    • Doroudi, A.1
  • 40
    • 76049104661 scopus 로고    scopus 로고
    • Relationship between the homotopy analysis method and harmonic balance method
    • Y. Chen, J. Liu, G. Meng,. Relationship between the homotopy analysis method and harmonic balance method. Commun. Nonlinear Sci. Numer. Simul. 2010, 15 (8), 2017-2025.
    • (2010) Commun. Nonlinear Sci. Numer. Simul. , vol.15 , Issue.8 , pp. 2017-2025
    • Chen, Y.1    Liu, J.2    Meng, G.3
  • 41
    • 0022894477 scopus 로고
    • A generalization of the method of harmonic balance
    • R. Mickens,. A generalization of the method of harmonic balance. J. Sound Vib. 1986, 111, 515-518.
    • (1986) J. Sound Vib. , vol.111 , pp. 515-518
    • Mickens, R.1
  • 42
    • 70350492887 scopus 로고    scopus 로고
    • Linear quadrupoles in mass spectrometry
    • D. Douglas,. Linear quadrupoles in mass spectrometry. Mass Spectrom. Rev. 2009, 28 (6), 937-960.
    • (2009) Mass Spectrom. Rev. , vol.28 , Issue.6 , pp. 937-960
    • Douglas, D.1
  • 43
    • 19444381354 scopus 로고    scopus 로고
    • Ion excitation in a linear quadrupole ion trap with an added octopole field
    • A. Michaud, A. Frank, C. Ding, X. Z. Zhao, D. Douglas,. Ion excitation in a linear quadrupole ion trap with an added octopole field. J. Am. Soc. Mass Spectrom. 2005, 16 (6), 835-849.
    • (2005) J. Am. Soc. Mass Spectrom. , vol.16 , Issue.6 , pp. 835-849
    • Michaud, A.1    Frank, A.2    Ding, C.3    Zhao, X.Z.4    Douglas, D.5
  • 46
    • 84868235912 scopus 로고    scopus 로고
    • Accelerated Simulation Study of Space Charge Effects in Quadrupole Ion Traps Using GPU Techniques
    • X. Xiong, W. Xu, X. Fang, Y. Deng, Z. Ouyang,. Accelerated Simulation Study of Space Charge Effects in Quadrupole Ion Traps Using GPU Techniques. J. Am. Soc. Mass Spectrom. 2012, 23 (10), 1799-1807.
    • (2012) J. Am. Soc. Mass Spectrom. , vol.23 , Issue.10 , pp. 1799-1807
    • Xiong, X.1    Xu, W.2    Fang, X.3    Deng, Y.4    Ouyang, Z.5
  • 47
    • 84971124048 scopus 로고
    • Harmonic balance and the Hopf bifurcation
    • D. Allwright,. In Harmonic balance and the Hopf bifurcation, Math. Proc. Camb. Phil. Soc, 1977, 82 (03), 453-467.
    • (1977) Math. Proc. Camb. Phil. Soc , vol.82 , Issue.3 , pp. 453-467
    • Allwright, D.1
  • 50
    • 80053054267 scopus 로고    scopus 로고
    • Modeling of ion transient response to dipolar AC excitation in a quadrupole ion trap
    • W. Xu, W. J. Chappell, Z. Ouyang,. Modeling of ion transient response to dipolar AC excitation in a quadrupole ion trap. Int. J. Mass Spectrom. 2011, 308 (1), 49-55.
    • (2011) Int. J. Mass Spectrom. , vol.308 , Issue.1 , pp. 49-55
    • Xu, W.1    Chappell, W.J.2    Ouyang, Z.3
  • 51
    • 0001325675 scopus 로고    scopus 로고
    • A two-dimensional quadrupole ion trap mass spectrometer
    • J. C. Schwartz, M. W. Senko, J. E. P. Syka,. A two-dimensional quadrupole ion trap mass spectrometer. J. Am. Soc. Mass Spectrom. 2002, 13 (6), 659-669.
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , Issue.6 , pp. 659-669
    • Schwartz, J.C.1    Senko, M.W.2    Syka, J.E.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.