메뉴 건너뛰기




Volumn 192, Issue , 2014, Pages 1-9

Magnetic-resonance imaging for kinetic analysis of permeability changes during focused ultrasound-induced blood-brain barrier opening and brain drug delivery

Author keywords

Blood brain barrier; Focused ultrasound; Kinetic analysis; Microbubble; MRI

Indexed keywords

BLOOD; DRUG DELIVERY; MAGNETIC RESONANCE IMAGING; MOLECULES; PLASMAS; RATE CONSTANTS; ULTRASONIC APPLICATIONS;

EID: 84904319430     PISSN: 01683659     EISSN: 18734995     Source Type: Journal    
DOI: 10.1016/j.jconrel.2014.06.023     Document Type: Article
Times cited : (53)

References (43)
  • 1
    • 0042899083 scopus 로고    scopus 로고
    • Blood-brain barrier drug targeting: The future of brain drug development
    • (151)
    • W.M. Pardridge Blood-brain barrier drug targeting: the future of brain drug development Mol. Interv. 3 2003 90 105 (151)
    • (2003) Mol. Interv. , vol.3 , pp. 90-105
    • Pardridge, W.M.1
  • 2
    • 0034876083 scopus 로고    scopus 로고
    • Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits
    • K. Hynynen, N. McDannold, N. Vykhodtseva, and F.A. Jolesz Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits Radiology 220 2001 640 646 (Pubitemid 32799969)
    • (2001) Radiology , vol.220 , Issue.3 , pp. 640-646
    • Hynynen, K.1    McDannold, N.2    Vykhodtseva, N.3    Jolesz, F.A.4
  • 3
    • 10044278240 scopus 로고    scopus 로고
    • Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications
    • DOI 10.1016/j.neuroimage.2004.06.046, PII S1053811904003362
    • K. Hynynen, N. McDannold, N.A. Sheikov, F.A. Jolesz, and N. Vykhodtseva Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications Neuroimage 24 2005 12 20 (Pubitemid 39611021)
    • (2005) NeuroImage , vol.24 , Issue.1 , pp. 12-20
    • Hynynen, K.1    McDannold, N.2    Sheikov, N.A.3    Jolesz, F.A.4    Vykhodtseva, N.5
  • 4
    • 27744441243 scopus 로고    scopus 로고
    • MRI-guided targeted blood-brain barrier disruption with focused ultrasound: Histological findings in rabbits
    • DOI 10.1016/j.ultrasmedbio.2005.07.010, PII S0301562905002905
    • N. McDannold, N. Vykhodtseva, S. Raymond, F.A. Jolesz, and K. Hynynen MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits Ultrasound Med. Biol. 31 2005 1527 1537 (Pubitemid 41606266)
    • (2005) Ultrasound in Medicine and Biology , vol.31 , Issue.11 , pp. 1527-1537
    • McDannold, N.1    Vykhodtseva, N.2    Raymond, S.3    Jolesz, F.A.4    Hynynen, K.5
  • 5
    • 33845675648 scopus 로고    scopus 로고
    • Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice
    • DOI 10.1016/j.ultrasmedbio.2006.07.018, PII S0301562906017467
    • J.J. Choi, M. Pernot, S.A. Small, and E.E. Konofagou Noninvasive, transcranial and localized opening of the blood-brain barrier using focused ultrasound in mice Ultrasound Med. Biol. 33 2007 95 104 (Pubitemid 44959316)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.1 , pp. 95-104
    • Choi, J.J.1    Pernot, M.2    Small, S.A.3    Konofagou, E.E.4
  • 6
    • 34547121440 scopus 로고    scopus 로고
    • Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound
    • DOI 10.1002/ijc.22732
    • L.H. Treat, N. McDannold, N. Vykhodtseva, Y. Zhang, K. Tam, and K. Hynynen Targeted delivery of doxorubicin to the rat brain at therapeutic levels using MRI-guided focused ultrasound Int. J. Cancer 121 2007 901 907 (Pubitemid 47106223)
    • (2007) International Journal of Cancer , vol.121 , Issue.4 , pp. 901-907
    • Treat, L.H.1    McDannold, N.2    Vykhodtseva, N.3    Zhang, Y.4    Tam, K.5    Hynynen, K.6
  • 7
    • 77951477367 scopus 로고    scopus 로고
    • Blood-brain barrier disruption with focused ultrasound enhances delivery of chemotherapeutic drugs for glioblastoma treatment
    • H.L. Liu, M.Y. Hua, P.Y. Chen, P.C. Chu, C.H. Pan, H.W. Yang, C.Y. Huang, J.J. Wang, T.C. Yen, and K.C. Wei Blood-brain barrier disruption with focused ultrasound enhances delivery of chemotherapeutic drugs for glioblastoma treatment Radiology 255 2010 415 425
    • (2010) Radiology , vol.255 , pp. 415-425
    • Liu, H.L.1    Hua, M.Y.2    Chen, P.Y.3    Chu, P.C.4    Pan, C.H.5    Yang, H.W.6    Huang, C.Y.7    Wang, J.J.8    Yen, T.C.9    Wei, K.C.10
  • 8
    • 84861985598 scopus 로고    scopus 로고
    • Focused ultrasound and interleukin-4 receptor-targeted liposomal doxorubicin for enhanced targeted drug delivery and antitumor effect in glioblastoma multiforme
    • F.Y. Yang, T.T. Wong, M.C. Teng, R.S. Liu, M. Lu, H.F. Liang, and M.C. Wei Focused ultrasound and interleukin-4 receptor-targeted liposomal doxorubicin for enhanced targeted drug delivery and antitumor effect in glioblastoma multiforme J. Control. Release 160 2012 652 658
    • (2012) J. Control. Release , vol.160 , pp. 652-658
    • Yang, F.Y.1    Wong, T.T.2    Teng, M.C.3    Liu, R.S.4    Lu, M.5    Liang, H.F.6    Wei, M.C.7
  • 9
    • 85027942646 scopus 로고    scopus 로고
    • Two-photon fluorescence microscopy study of cerebrovascular dynamics in ultrasound-induced blood-brain barrier opening
    • E.E. Cho, J. Drazic, M. Ganguly, B. Stefanovic, and K. Hynynen Two-photon fluorescence microscopy study of cerebrovascular dynamics in ultrasound-induced blood-brain barrier opening J. Cereb. Blood Flow Metab. 31 2011 1852 1862
    • (2011) J. Cereb. Blood Flow Metab. , vol.31 , pp. 1852-1862
    • Cho, E.E.1    Drazic, J.2    Ganguly, M.3    Stefanovic, B.4    Hynynen, K.5
  • 10
    • 45949097554 scopus 로고    scopus 로고
    • Effect of Focused Ultrasound Applied With an Ultrasound Contrast Agent on the Tight Junctional Integrity of the Brain Microvascular Endothelium
    • DOI 10.1016/j.ultrasmedbio.2007.12.015, PII S030156290700659X
    • N. Sheikov, N. McDannold, S. Sharma, and K. Hynynen Effect of focused ultrasound applied with an ultrasound contrast agent on the tight junctional integrity of the brain microvascular endothelium Ultrasound Med. Biol. 34 2008 1093 1104 (Pubitemid 351893156)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.7 , pp. 1093-1104
    • Sheikov, N.1    McDannold, N.2    Sharma, S.3    Hynynen, K.4
  • 11
    • 60349085115 scopus 로고    scopus 로고
    • Magnetic resonance imaging enhanced by superparamagnetic iron oxide particles: Usefulness for distinguishing between focused ultrasound-induced blood-brain barrier disruption and brain hemorrhage
    • H.L. Liu, P.H. Hsu, P.C. Chu, Y.Y. Wai, J.C. Chen, C.R. Shen, T.C. Yen, and J.J. Wang Magnetic resonance imaging enhanced by superparamagnetic iron oxide particles: usefulness for distinguishing between focused ultrasound-induced blood-brain barrier disruption and brain hemorrhage J. Magn. Reson. Imaging 29 2009 31 38
    • (2009) J. Magn. Reson. Imaging , vol.29 , pp. 31-38
    • Liu, H.L.1    Hsu, P.H.2    Chu, P.C.3    Wai, Y.Y.4    Chen, J.C.5    Shen, C.R.6    Yen, T.C.7    Wang, J.J.8
  • 12
    • 77951159853 scopus 로고    scopus 로고
    • Gd-DTPA-loaded PLGA microbubbles as both ultrasound contrast agent and MRI contrast agent - A feasibility research
    • M. Ao, Z. Wang, H. Ran, D. Guo, J. Yu, A. Li, W. Chen, W. Wu, and Y. Zheng Gd-DTPA-loaded PLGA microbubbles as both ultrasound contrast agent and MRI contrast agent - a feasibility research J. Biomed. Mater. Res. B Appl. Biomater. 93 2010 551 556
    • (2010) J. Biomed. Mater. Res. B Appl. Biomater. , vol.93 , pp. 551-556
    • Ao, M.1    Wang, Z.2    Ran, H.3    Guo, D.4    Yu, J.5    Li, A.6    Chen, W.7    Wu, W.8    Zheng, Y.9
  • 13
    • 82855172085 scopus 로고    scopus 로고
    • Theranostic Gd(III)-lipid microbubbles for MRI-guided focused ultrasound surgery
    • J.A. Feshitan, F. Vlachos, S.R. Sirsi, E.E. Konofagou, and M.A. Borden Theranostic Gd(III)-lipid microbubbles for MRI-guided focused ultrasound surgery Biomaterials 33 2012 247 255
    • (2012) Biomaterials , vol.33 , pp. 247-255
    • Feshitan, J.A.1    Vlachos, F.2    Sirsi, S.R.3    Konofagou, E.E.4    Borden, M.A.5
  • 14
    • 84860122228 scopus 로고    scopus 로고
    • Paramagnetic perfluorocarbon-filled albumin-(Gd-DTPA) microbubbles for the induction of focused-ultrasound-induced blood-brain barrier opening and concurrent MR and ultrasound imaging
    • A.H. Liao, H.L. Liu, C.H. Su, M.Y. Hua, H.W. Yang, Y.T. Weng, P.H. Hsu, S.M. Huang, S.Y. Wu, H.E. Wang, T.C. Yen, and P.C. Li Paramagnetic perfluorocarbon-filled albumin-(Gd-DTPA) microbubbles for the induction of focused-ultrasound-induced blood-brain barrier opening and concurrent MR and ultrasound imaging Phys. Med. Biol. 57 2012 2787 2802
    • (2012) Phys. Med. Biol. , vol.57 , pp. 2787-2802
    • Liao, A.H.1    Liu, H.L.2    Su, C.H.3    Hua, M.Y.4    Yang, H.W.5    Weng, Y.T.6    Hsu, P.H.7    Huang, S.M.8    Wu, S.Y.9    Wang, H.E.10    Yen, T.C.11    Li, P.C.12
  • 15
    • 84875279479 scopus 로고    scopus 로고
    • SPIO-conjugated, doxorubicin-loaded microbubbles for concurrent MRI and focused-ultrasound enhanced brain-tumor drug delivery
    • C.H. Fan, C.Y. Ting, H.J. Lin, C.H. Wang, H.L. Liu, T.C. Yen, and C.K. Yeh SPIO-conjugated, doxorubicin-loaded microbubbles for concurrent MRI and focused-ultrasound enhanced brain-tumor drug delivery Biomaterials 34 2013 3706 3715
    • (2013) Biomaterials , vol.34 , pp. 3706-3715
    • Fan, C.H.1    Ting, C.Y.2    Lin, H.J.3    Wang, C.H.4    Liu, H.L.5    Yen, T.C.6    Yeh, C.K.7
  • 17
    • 84877278845 scopus 로고    scopus 로고
    • Pharmacodynamic analysis of magnetic resonance imaging-monitored focused ultrasound-induced blood-brain barrier opening for drug delivery to brain tumors
    • P.C. Chu, W.Y. Chai, H.Y. Hsieh, J.J. Wang, S.P. Wey, C.Y. Huang, K.C. Wei, and H.L. Liu Pharmacodynamic analysis of magnetic resonance imaging-monitored focused ultrasound-induced blood-brain barrier opening for drug delivery to brain tumors Biomed. Res. Int. 2013 2013 627496
    • (2013) Biomed. Res. Int. , vol.2013 , pp. 627496
    • Chu, P.C.1    Chai, W.Y.2    Hsieh, H.Y.3    Wang, J.J.4    Wey, S.P.5    Huang, C.Y.6    Wei, K.C.7    Liu, H.L.8
  • 18
    • 34547207309 scopus 로고    scopus 로고
    • Validation of dynamic contrast-enhanced magnetic resonance imaging-derived vascular permeability measurements using quantitative autoradiography in the RG2 rat brain tumor model
    • DOI 10.1593/neo.07289
    • M.C. Ferrier, H. Sarin, S.H. Fung, B. Schatlo, R.M. Pluta, S.N. Gupta, P.L. Choyke, E.H. Oldfield, D. Thomasson, and J.A. Butman Validation of dynamic contrast-enhanced magnetic resonance imaging-derived vascular permeability measurements using quantitative autoradiography in the RG2 rat brain tumor model Neoplasia 9 2007 546 555 (Pubitemid 47121828)
    • (2007) Neoplasia , vol.9 , Issue.7 , pp. 546-555
    • Ferrier, M.C.1    Sarin, H.2    Fung, S.H.3    Schatlo, B.4    Pluta, R.M.5    Gupta, S.N.6    Choykeb, P.L.7    Oldfield, E.H.8    Thomasson, D.9    Butman, J.A.10
  • 19
    • 78149338317 scopus 로고    scopus 로고
    • Permeability assessment of the focused ultrasound-induced blood-brain barrier opening using dynamic contrast-enhanced MRI
    • F. Vlachos, Y.S. Tung, and E.E. Konofagou Permeability assessment of the focused ultrasound-induced blood-brain barrier opening using dynamic contrast-enhanced MRI Phys. Med. Biol. 55 2010 5451 5466
    • (2010) Phys. Med. Biol. , vol.55 , pp. 5451-5466
    • Vlachos, F.1    Tung, Y.S.2    Konofagou, E.E.3
  • 20
    • 80051704697 scopus 로고    scopus 로고
    • Permeability dependence study of the focused ultrasound-induced blood-brain barrier opening at distinct pressures and microbubble diameters using DCE-MRI
    • F. Vlachos, Y.S. Tung, and E. Konofagou Permeability dependence study of the focused ultrasound-induced blood-brain barrier opening at distinct pressures and microbubble diameters using DCE-MRI Magn. Reson. Med. 66 2011 821 830
    • (2011) Magn. Reson. Med. , vol.66 , pp. 821-830
    • Vlachos, F.1    Tung, Y.S.2    Konofagou, E.3
  • 21
    • 70449411152 scopus 로고    scopus 로고
    • Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 T
    • H.B. Larsson, F. Courivaud, E. Rostrup, and A.E. Hansen Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 T Magn. Reson. Med. 62 2009 1270 1281
    • (2009) Magn. Reson. Med. , vol.62 , pp. 1270-1281
    • Larsson, H.B.1    Courivaud, F.2    Rostrup, E.3    Hansen, A.E.4
  • 22
    • 73949124494 scopus 로고    scopus 로고
    • Focused ultrasound microbubble destruction-mediated changes in blood-brain barrier permeability assessed by contrast-enhanced magnetic resonance imaging
    • F. Wang, Y. Cheng, J. Mei, Y. Song, Y.Q. Yang, Y. Liu, and Z. Wang Focused ultrasound microbubble destruction-mediated changes in blood-brain barrier permeability assessed by contrast-enhanced magnetic resonance imaging J. Ultrasound Med. 28 2009 1501 1509
    • (2009) J. Ultrasound Med. , vol.28 , pp. 1501-1509
    • Wang, F.1    Cheng, Y.2    Mei, J.3    Song, Y.4    Yang, Y.Q.5    Liu, Y.6    Wang, Z.7
  • 23
    • 79952776352 scopus 로고    scopus 로고
    • Quantitative measurement of blood-brain barrier permeability in human using dynamic contrast-enhanced MRI with fast T1 mapping
    • S. Taheri, C. Gasparovic, N.J. Shah, and G.A. Rosenberg Quantitative measurement of blood-brain barrier permeability in human using dynamic contrast-enhanced MRI with fast T1 mapping Magn. Reson. Med. 65 2011 1036 1042
    • (2011) Magn. Reson. Med. , vol.65 , pp. 1036-1042
    • Taheri, S.1    Gasparovic, C.2    Shah, N.J.3    Rosenberg, G.A.4
  • 24
    • 84864653876 scopus 로고    scopus 로고
    • The kinetics of blood brain barrier permeability and targeted doxorubicin delivery into brain induced by focused ultrasound
    • J. Park, Y. Zhang, N. Vykhodtseva, F.A. Jolesz, and N.J. McDannold The kinetics of blood brain barrier permeability and targeted doxorubicin delivery into brain induced by focused ultrasound J. Control. Release 162 2012 134 142
    • (2012) J. Control. Release , vol.162 , pp. 134-142
    • Park, J.1    Zhang, Y.2    Vykhodtseva, N.3    Jolesz, F.A.4    McDannold, N.J.5
  • 25
    • 0026011540 scopus 로고
    • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts
    • P.S. Tofts, and A.G. Kermode Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts Magn. Reson. Med. 17 1991 357 367
    • (1991) Magn. Reson. Med. , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 26
    • 0031404162 scopus 로고    scopus 로고
    • Modeling tracer kinetics in dynamic Gd-DTPA MR imaging
    • DOI 10.1002/jmri.1880070113
    • P.S. Tofts Modeling tracer kinetics in dynamic Gd-DTPA MR imaging J. Magn. Reson. Imaging 7 1997 91 101 (Pubitemid 28365643)
    • (1997) Journal of Magnetic Resonance Imaging , vol.7 , Issue.1 , pp. 91-101
    • Tofts, P.S.1
  • 28
    • 40949159717 scopus 로고    scopus 로고
    • Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging
    • H.L. Liu, Y.Y. Wai, W.S. Chen, J.C. Chen, P.H. Hsu, X.Y. Wu, W.C. Huang, T.C. Yen, and J.J. Wang Hemorrhage detection during focused-ultrasound induced blood-brain-barrier opening by using susceptibility-weighted magnetic resonance imaging Ultrasound Med. Biol. 34 2008 598 606
    • (2008) Ultrasound Med. Biol. , vol.34 , pp. 598-606
    • Liu, H.L.1    Wai, Y.Y.2    Chen, W.S.3    Chen, J.C.4    Hsu, P.H.5    Wu, X.Y.6    Huang, W.C.7    Yen, T.C.8    Wang, J.J.9
  • 29
    • 44349129408 scopus 로고
    • The theory and applications of the exchange of inert gas at the lungs and tissues
    • S.S. Kety The theory and applications of the exchange of inert gas at the lungs and tissues Pharmacol. Rev. 3 1951 1 41
    • (1951) Pharmacol. Rev. , vol.3 , pp. 1-41
    • Kety, S.S.1
  • 30
    • 36849025955 scopus 로고    scopus 로고
    • Incorporating contrast agent diffusion into the analysis of DCE-MRI data
    • DOI 10.1002/mrm.21400
    • M. Pellerin, T.E. Yankeelov, and M. Lepage Incorporating contrast agent diffusion into the analysis of DCE-MRI data Magn. Reson. Med. 58 2007 1124 1134 (Pubitemid 350234199)
    • (2007) Magnetic Resonance in Medicine , vol.58 , Issue.6 , pp. 1124-1134
    • Pellerin, M.1    Yankeelov, T.E.2    Lepage, M.3
  • 31
    • 43849110904 scopus 로고    scopus 로고
    • Effects of Acoustic Parameters and Ultrasound Contrast Agent Dose on Focused-Ultrasound Induced Blood-Brain Barrier Disruption
    • DOI 10.1016/j.ultrasmedbio.2007.11.009, PII S0301562907005698
    • N. McDannold, N. Vykhodtseva, and K. Hynynen Effects of acoustic parameters and ultrasound contrast agent dose on focused-ultrasound induced blood-brain barrier disruption Ultrasound Med. Biol. 34 2008 930 937 (Pubitemid 351697595)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.6 , pp. 930-937
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 32
    • 42949140276 scopus 로고    scopus 로고
    • Blood-Brain Barrier Disruption Induced by Focused Ultrasound and Circulating Preformed Microbubbles Appears to Be Characterized by the Mechanical Index
    • DOI 10.1016/j.ultrasmedbio.2007.10.016, PII S0301562907005480
    • N. McDannold, N. Vykhodtseva, and K. Hynynen Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index Ultrasound Med. Biol. 34 2008 834 840 (Pubitemid 351608039)
    • (2008) Ultrasound in Medicine and Biology , vol.34 , Issue.5 , pp. 834-840
    • McDannold, N.1    Vykhodtseva, N.2    Hynynen, K.3
  • 33
    • 48149101439 scopus 로고    scopus 로고
    • Progress and problems in the application of focused ultrasound for blood-brain barrier disruption
    • N. Vykhodtseva, N. McDannold, and K. Hynynen Progress and problems in the application of focused ultrasound for blood-brain barrier disruption Ultrasonics 48 2008 279 296
    • (2008) Ultrasonics , vol.48 , pp. 279-296
    • Vykhodtseva, N.1    McDannold, N.2    Hynynen, K.3
  • 34
    • 44249098561 scopus 로고    scopus 로고
    • Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption
    • F.Y. Yang, W.M. Fu, W.S. Chen, W.L. Yeh, and W.L. Lin Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption Ultrason. Sonochem. 15 2008 636 643
    • (2008) Ultrason. Sonochem. , vol.15 , pp. 636-643
    • Yang, F.Y.1    Fu, W.M.2    Chen, W.S.3    Yeh, W.L.4    Lin, W.L.5
  • 35
    • 34548130700 scopus 로고    scopus 로고
    • Quantitative evaluation of focused ultrasound with a contrast agent on blood-brain barrier disruption
    • F.Y. Yang, W.M. Fu, R.S. Yang, H.C. Liou, K.H. Kang, and W.L. Lin Quantitative evaluation of focused ultrasound with a contrast agent on blood-brain barrier disruption Ultrasound Med. Biol. 33 2007 1421 1427
    • (2007) Ultrasound Med. Biol. , vol.33 , pp. 1421-1427
    • Yang, F.Y.1    Fu, W.M.2    Yang, R.S.3    Liou, H.C.4    Kang, K.H.5    Lin, W.L.6
  • 37
    • 77953303635 scopus 로고    scopus 로고
    • Influence of exposure time and pressure amplitude on blood-brain-barrier opening using transcranial ultrasound exposures
    • R. Chopra, N. Vykhodtseva, and K. Hynynen Influence of exposure time and pressure amplitude on blood-brain-barrier opening using transcranial ultrasound exposures ACS Chem. Neurosci. 1 2010 391 398
    • (2010) ACS Chem. Neurosci. , vol.1 , pp. 391-398
    • Chopra, R.1    Vykhodtseva, N.2    Hynynen, K.3
  • 38
    • 0028932174 scopus 로고
    • The effect of verapamil on the transport of peptides across the blood-brain barrier in rats: Kinetic evidence for an apically polarized efflux mechanism
    • E.G. Chikhale, P.S. Burton, and R.T. Borchardt The effect of verapamil on the transport of peptides across the blood-brain barrier in rats: kinetic evidence for an apically polarized efflux mechanism J. Pharmacol. Exp. Ther. 273 1995 298 303
    • (1995) J. Pharmacol. Exp. Ther. , vol.273 , pp. 298-303
    • Chikhale, E.G.1    Burton, P.S.2    Borchardt, R.T.3
  • 39
    • 0035253135 scopus 로고    scopus 로고
    • Efflux transport systems for drugs at the blood-brain barrier and blood-cerebrospinal fluid barrier (Part 1)
    • DOI 10.1016/S1359-6446(00)01632-9, PII S1359644600016329
    • H. Kusuhara, and Y. Sugiyama Efflux transport systems for drugs at the blood-brain barrier and blood-cerebrospinal fluid barrier (Part 1) Drug Discov. Today 6 2001 150 156 (Pubitemid 32098289)
    • (2001) Drug Discovery Today , vol.6 , Issue.3 , pp. 150-156
    • Kusuhara, H.1    Sugiyama, Y.2
  • 40
    • 0035254189 scopus 로고    scopus 로고
    • Efflux transport systems for drugs at the blood-brain barrier and blood-cerebrospinal fluid barrier (Part 2)
    • DOI 10.1016/S1359-6446(00)01643-3, PII S1359644600016433
    • H. Kusuhara, and Y. Sugiyama Efflux transport systems for drugs at the blood-brain barrier and blood-cerebrospinal fluid barrier (Part 2) Drug Discov. Today 6 2001 206 212 (Pubitemid 32118193)
    • (2001) Drug Discovery Today , vol.6 , Issue.4 , pp. 206-212
    • Kusuhara, H.1    Sugiyama, Y.2
  • 41
    • 0030426820 scopus 로고    scopus 로고
    • Brain efflux index as a novel method of analyzing efflux transport at the blood-brain barrier
    • A. Kakee, T. Terasaki, and Y. Sugiyama Brain efflux index as a novel method of analyzing efflux transport at the blood-brain barrier J. Pharmacol. Exp. Ther. 277 1996 1550 1559 (Pubitemid 27167171)
    • (1996) Journal of Pharmacology and Experimental Therapeutics , vol.277 , Issue.3 , pp. 1550-1559
    • Kakee, A.1    Terasaki, T.2    Sugiyama, Y.3
  • 42
    • 84857366157 scopus 로고    scopus 로고
    • A quantitative pressure and microbubble-size dependence study of focused ultrasound-induced blood-brain barrier opening reversibility in vivo using MRI
    • G. Samiotaki, F. Vlachos, Y.S. Tung, and E.E. Konofagou A quantitative pressure and microbubble-size dependence study of focused ultrasound-induced blood-brain barrier opening reversibility in vivo using MRI Magn. Reson. Med. 67 2012 769 777
    • (2012) Magn. Reson. Med. , vol.67 , pp. 769-777
    • Samiotaki, G.1    Vlachos, F.2    Tung, Y.S.3    Konofagou, E.E.4
  • 43
    • 84884334999 scopus 로고    scopus 로고
    • Drug delivery to the brain by focused ultrasound induced blood-brain barrier disruption: Quantitative evaluation of enhanced permeability of cerebral vasculature using two-photon microscopy
    • T. Nhan, A. Burgess, E.E. Cho, B. Stefanovic, L. Lilge, and K. Hynynen Drug delivery to the brain by focused ultrasound induced blood-brain barrier disruption: quantitative evaluation of enhanced permeability of cerebral vasculature using two-photon microscopy J. Control. Release 172 2013 274 280
    • (2013) J. Control. Release , vol.172 , pp. 274-280
    • Nhan, T.1    Burgess, A.2    Cho, E.E.3    Stefanovic, B.4    Lilge, L.5    Hynynen, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.