-
1
-
-
84903580287
-
-
Touch EMAS Ltd
-
Touch EMAS Ltd., http://www.touchbionics.com, 2014.
-
-
-
-
2
-
-
84903580288
-
-
RSL Steeper
-
RSL Steeper, http://www.bebionic.com, 2014..
-
-
-
-
3
-
-
67349146792
-
Coding and use of tactile signals from the fingertips in object manipulation tasks
-
May
-
R.S. Johansson and J.R. Flanagan, "Coding and Use of Tactile Signals from the Fingertips in Object Manipulation Tasks," Nature Rev. Neuroscience, vol. 10, no. 5, pp. 345-359, May 2009.
-
(2009)
Nature Rev. Neuroscience
, vol.10
, Issue.5
, pp. 345-359
-
-
Johansson, R.S.1
Flanagan, J.R.2
-
4
-
-
84868154345
-
The design of artificial arms and hands for prosthetic applications
-
M. Kutz, ed. McGraw-Hill
-
R. Weir and J. Sensinger, "The Design of Artificial Arms and Hands for Prosthetic Applications," Biomedical Engineering and Design Handbook (Volume II: Applications), M. Kutz, ed., pp. 537-598, McGraw-Hill, 2009.
-
(2009)
Biomedical Engineering and Design Handbook (Volume II: Applications)
, pp. 537-598
-
-
Weir, R.1
Sensinger, J.2
-
5
-
-
0019300990
-
Closed-loop control in prosthetic systems: Historical perspective
-
D.S. Childress, "Closed-Loop Control in Prosthetic Systems: Historical Perspective," Annals of Biomedical Eng., vol. 8, no. 4-6, pp. 293-303, 1980.
-
(1980)
Annals of Biomedical Eng
, vol.8
, Issue.4-6
, pp. 293-303
-
-
Childress, D.S.1
-
6
-
-
0018913645
-
Sensory-feed back system compatible with myoelectric control
-
R.N. Scott, R.H. Brittain, R.R. Caldwell, A.B. Cameron, and V.A. Dunfield, "Sensory-Feed back System Compatible with Myoelectric Control," Medical and Biological Eng. and Computing, vol. 18, no. 1, pp. 65-69, 1980.
-
(1980)
Medical and Biological Eng. and Computing
, vol.18
, Issue.1
, pp. 65-69
-
-
Scott, R.N.1
Brittain, R.H.2
Caldwell, R.R.3
Cameron, A.B.4
Dunfield, V.A.5
-
7
-
-
0033380863
-
Strategies for providing upper extremity amputees with tactile and hand position feedback-moving closer to the bionic arm
-
R.R. Riso, "Strategies for Providing Upper Extremity Amputees with Tactile and Hand Position Feedback-Moving Closer to the Bionic Arm," Technology and Health Care, vol. 7, no. 6, pp. 401-409, 1999.
-
(1999)
Technology and Health Care
, vol.7
, Issue.6
, pp. 401-409
-
-
Riso, R.R.1
-
8
-
-
84871951414
-
Sensory feed back in upper limb prosthetics
-
Jan.
-
C. Antfolk, M. D'Alonzo, B. Ros-en, G. Lundborg, F. Sebelius, and C. Cipriani, "Sensory Feedback in Upper Limb Prosthetics," Expert Rev. of Medical Devices, vol. 10, no. 1, pp. 45-54, Jan. 2013.
-
(2013)
Expert Rev. of Medical Devices
, vol.10
, Issue.1
, pp. 45-54
-
-
Antfolk, C.1
D'Alonzo, M.2
Rosen, B.3
Lundborg, G.4
Sebelius, F.5
Cipriani, C.6
-
9
-
-
29644439037
-
Direct neural sensory feed back and control of a prosthetic arm
-
G.S. Dhillon and K.W. Horch, "Direct Neural Sensory Feedback and Control of a Prosthetic Arm," IEEE Trans. Neural Systems and Rehabilitation Eng., vol. 13, no. 4, pp. 468-472, 2005.
-
(2005)
IEEE Trans. Neural Systems and Rehabilitation Eng.
, vol.13
, Issue.4
, pp. 468-472
-
-
Dhillon, G.S.1
Horch, K.W.2
-
10
-
-
80054062765
-
Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes
-
K. Horch, S. Meek, T.G. Taylor, and D.T. Hutchinson, "Object Discrimination with an Artificial Hand Using Electrical Stimulation of Peripheral Tactile and Proprioceptive Pathways with Intrafascicular Electrodes," IEEE Trans. Neural Systems Rehabilitation Eng., vol. 19, no. 5, pp. 483-489, 2011.
-
(2011)
IEEE Trans. Neural Systems Rehabilitation Eng
, vol.19
, Issue.5
, pp. 483-489
-
-
Horch, K.1
Meek, S.2
Taylor, T.G.3
Hutchinson, D.T.4
-
11
-
-
78650151787
-
Grip force feed back in an electric hand-preliminary results
-
H. Sears, E. Iversen, S. Archer, J. Linder, and K. Hays, "Grip Force Feed back in an Electric Hand-Preliminary Results," Proc. Myoelectric Controls/Prosthetics Symp., pp. 175-178, 2008.
-
(2008)
Proc. Myoelectric Controls/Prosthetics Symp.
, pp. 175-178
-
-
Sears, H.1
Iversen, E.2
Archer, S.3
Linder, J.4
Hays, K.5
-
12
-
-
84871985797
-
Transfer of tactile input from an artificial hand to the forearm: Experiments in amputees and healthy volunteers
-
May
-
C. Antfolk, C. Cipriani, M.C. Carrozza, C. Balkenius, A. Bjorkman, G. Lundborg, B. Rosen, and F. Sebelius, "Transfer of Tactile Input from an Artificial Hand to the Forearm: Experiments in Amputees and Healthy Volunteers," Disability and Rehabilitation. Assistive Technology, vol. 8, no. 3, pp. 249-254, May 2013.
-
(2013)
Disability and Rehabilitation. Assistive Technology
, vol.8
, Issue.3
, pp. 249-254
-
-
Antfolk, C.1
Cipriani, C.2
Carrozza, M.C.3
Balkenius, C.4
Bjorkman, A.5
Lundborg, G.6
Rosen, B.7
Sebelius, F.8
-
13
-
-
70649088202
-
On the design of miniature haptics devices for upper extremity prosthetics
-
Feb.
-
K. Kim, J.E. Colgate, J.J. Santos-Munne, A. Makhin, and M. Peshkin, "On the Design of Miniature Haptics Devices for Upper Extremity Prosthetics," IEEE Trans. Mechatronics, vol. 11, no. 1, pp. 27-39, Feb. 2010.
-
(2010)
IEEE Trans. Mechatronics
, vol.11
, Issue.1
, pp. 27-39
-
-
Kim, K.1
Colgate, J.E.2
Santos-Munne, J.J.3
Makhin, A.4
Peshkin, M.5
-
14
-
-
0026096943
-
Electrotactile and vibrotactile displays for sensory substitution system
-
Jan.
-
K.A. Kaczmarek, J.G. Webster, P. Bach-y-Rita, and W.J. Tompkins, "Electrotactile and Vibrotactile Displays for Sensory Substitution System," IEEE Trans. Biomedical Eng., vol. 38, no. 1, pp. 1-6, Jan. 1991.
-
(1991)
IEEE Trans. Biomedical Eng.
, vol.38
, Issue.1
, pp. 1-6
-
-
Kaczmarek, K.A.1
Webster, J.G.2
Bach-Y-Rita, P.3
Tompkins, W.J.4
-
15
-
-
79651471227
-
Impacts of selected stimulation patterns on the perception threshold in electrocutaneous stimulation
-
B. Geng, K. Yoshida, and W. Jensen, "Impacts of Selected Stimulation Patterns on the Perception Threshold in Electrocutaneous Stimulation," J. NeuroEng. Rehabilitation, vol. 8, no. 9, pp. 1-10, 2011.
-
(2011)
J. NeuroEng. Rehabilitation
, vol.8
, Issue.9
, pp. 1-10
-
-
Geng, B.1
Yoshida, K.2
Jensen, W.3
-
17
-
-
84856201341
-
A miniature vibrotactile sensory substitution device for multifingered hand prosthetics
-
Feb.
-
C. Cipriani, M. D'Alonzo, and M.C. Carrozza, "A Miniature Vibrotactile Sensory Substitution Device for Multifingered Hand Prosthetics," IEEE Trans. Biomedical Eng., vol. 59, no. 2, pp. 400-408, Feb. 2012.
-
(2012)
IEEE Trans. Biomedical Eng.
, vol.59
, Issue.2
, pp. 400-408
-
-
Cipriani, C.1
D'Alonzo, M.2
Carrozza, M.C.3
-
18
-
-
0016951961
-
A comparison of alternative means of providing sensory feed back on upper limb prostheses
-
May
-
G.F. Shannon, "A Comparison of Alternative Means of Providing Sensory Feedback on Upper Limb Prostheses," Medical and Biological Eng., vol. 14, pp. 289-294, May 1976.
-
(1976)
Medical and Biological Eng
, vol.14
, pp. 289-294
-
-
Shannon, G.F.1
-
19
-
-
84871981621
-
Artificial redirection of sensation from prosthetic fingers to the phantom hand map on transradial amputees: Vibrotactile vs. Mechanotactile sensory feed back
-
Jan.
-
C. Antfolk, M. D'Alonzo, M. Controzzi, B. Rosen, G. Lundborg, F. Sebelius, and C. Cipriani, "Artificial Redirection of Sensation from Prosthetic Fingers to the Phantom Hand Map on Transradial Amputees: Vibrotactile vs. Mechanotactile Sensory Feedback," IEEE Trans. Neural Systems and Rehabilitation Eng., vol. 21, no. 1, pp. 112-120, Jan. 2012.
-
(2012)
IEEE Trans. Neural Systems and Rehabilitation Eng
, vol.21
, Issue.1
, pp. 112-120
-
-
Antfolk, C.1
D'Alonzo, M.2
Controzzi, M.3
Rosen, B.4
Lundborg, G.5
Sebelius, F.6
Cipriani, C.7
-
20
-
-
80054943371
-
The role of feed-forward and feedback processes for closed-loop prosthesis control
-
I. Saunders and S. Vijayakumar, "The Role of Feed-Forward and Feedback Processes for Closed-Loop Prosthesis Control," J. Neuroeng. Rehabilitation, vol. 8, no. 60, pp. 1-12, 2011.
-
(2011)
J. Neuroeng. Rehabilitation
, vol.8
, Issue.60
, pp. 1-12
-
-
Saunders, I.1
Vijayakumar, S.2
-
21
-
-
41849087742
-
Testing a prosthetic haptic feed back simulator with an interactive force matching task
-
A. Chatterjee, P. Chaubey, J. Martin, and N. Thakor, "Testing a Prosthetic Haptic Feedback Simulator with an Interactive Force Matching Task," J. Prosthetics and Orthotics, vol. 20, no. 2, pp. 27-34, 2008.
-
(2008)
J. Prosthetics and Orthotics
, vol.20
, Issue.2
, pp. 27-34
-
-
Chatterjee, A.1
Chaubey, P.2
Martin, J.3
Thakor, N.4
-
22
-
-
40949129655
-
On the shared control of an EMG-controlled prosthetic hand: Analysis of user-prosthesis interaction
-
Feb.
-
C. Cipriani, F. Zaccone, S. Micera, and M.C. Carrozza, "On the Shared Control of an EMG-Controlled Prosthetic Hand: Analysis of User-Prosthesis Interaction," IEEE Trans. Robotics, vol. 24, no. 1, pp. 170-184, Feb. 2008.
-
(2008)
IEEE Trans. Robotics
, vol.24
, Issue.1
, pp. 170-184
-
-
Cipriani, C.1
Zaccone, F.2
Micera, S.3
Carrozza, M.C.4
-
23
-
-
18844371552
-
Objectives and technological approach to the development of the multifunctional manus upper limb prosthesis
-
J.L. Pons, R. Ceres, E. Rocon, D. Reynaerts, B. Saro, S. Levin, and W.V. Moorleghem, "Objectives and Technological Approach to the Development of the Multifunctional MANUS Upper Limb Prosthesis," Robotica, vol. 23, no. 3, pp. 301-310, 2005.
-
(2005)
Robotica
, vol.23
, Issue.3
, pp. 301-310
-
-
Pons, J.L.1
Ceres, R.2
Rocon, E.3
Reynaerts, D.4
Saro, B.5
Levin, S.6
Moorleghem, W.V.7
-
24
-
-
33749435189
-
Design and evaluation of a low-cost force feed back system for myoelectric prosthetic hands
-
C. Pylatiuk, A. Kargov, and S. Schulz, "Design and Evaluation of a Low-Cost Force Feed back System for Myoelectric Prosthetic Hands," J. Prosthetics and Orthotics, vol. 18, no. 2, pp. 57-61, 2006.
-
(2006)
J. Prosthetics and Orthotics
, vol.18
, Issue.2
, pp. 57-61
-
-
Pylatiuk, C.1
Kargov, A.2
Schulz, S.3
-
25
-
-
0031762621
-
Artificial sensibility based on the use of piezoresistive sensors. Preliminary observations
-
G. Lundborg, B. Rosen, K. Lindstrom, and S. Lindberg, "Artificial Sensibility Based on the Use of Piezoresistive Sensors. Preliminary Observations," J. Hand Surgery: British & European Volume, vol. 23, no. 5, pp. 620-626, 1998.
-
(1998)
J. Hand Surgery: British & European
, vol.23
, Issue.5
, pp. 620-626
-
-
Lundborg, G.1
Rosen, B.2
Lindstrom, K.3
Lindberg, S.4
-
26
-
-
0018412407
-
Sensory feed back for artificial limbs
-
G.F. Shannon, "Sensory Feedback for Artificial Limbs," Medical Progress through Technology, vol. 6, no. 2, pp. 73-79, 1979.
-
(1979)
Medical Progress Through Technology
, vol.6
, Issue.2
, pp. 73-79
-
-
Shannon, G.F.1
-
27
-
-
84896477498
-
HyVE: Hybrid vibro-electrotactile stimulation for sensory feedback and substitution in rehabilitation
-
DOI: 10.1109/TNSRE.2013.2266482
-
M. D'Alonzo, S. Dosen, C. Cipriani, and D. Farina, "HyVE: Hybrid Vibro-Electrotactile Stimulation for Sensory Feedback and Substitution in Rehabilitation," IEEE Trans. Neural Systems And Rehabilitation Eng., vol. 22, no. 2, pp. 290-301, 2014, DOI: 10.1109/TNSRE.2013.2266482.
-
(2014)
IEEE Trans. Neural Systems and Rehabilitation Eng
, vol.22
, Issue.2
, pp. 290-301
-
-
D'Alonzo, M.1
Dosen, S.2
Cipriani, C.3
Farina, D.4
-
28
-
-
84865973189
-
Sensory feed back from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin
-
C. Antfolk, A. Bjorkman, S.O. Frank, F. Sebelius, G. Lundborg, and B. Rosen, "Sensory Feedback from a Prosthetic Hand Based on Air-Mediated Pressure From the Hand to the Forearm Skin," J. Rehabilitation Medicine, vol. 44, pp. 702-707, 2012.
-
(2012)
J. Rehabilitation Medicine
, vol.44
, pp. 702-707
-
-
Antfolk, C.1
Bjorkman, A.2
Frank, S.O.3
Sebelius, F.4
Lundborg, G.5
Rosen, B.6
-
30
-
-
0014747486
-
Kinesthetic sensing for the EMG controlled boston arm
-
Mar.
-
R.W. Mann and S.D. Reimers, "Kinesthetic Sensing for the EMG Controlled Boston Arm," IEEE Trans. Man-Machine Systems, vol. MM-11, no. 1, pp. 110-115, Mar. 1970.
-
(1970)
IEEE Trans. Man-Machine Systems
, vol.MM-11
, Issue.1
, pp. 110-115
-
-
Mann, R.W.1
Reimers, S.D.2
-
31
-
-
84864217853
-
Vibro-and electrotactile user feed back on hand opening for myoelectric forearm pros theses
-
Aug.
-
H.J.B. Witteveen, E.A. Droog, J.S. Rietman, and P.H. Veltink, "Vibro-and Electrotactile User Feed back on Hand Opening for Myoelectric Forearm Prostheses," IEEE Trans. Biomedical Eng., vol. 59, no. 8, pp. 2219-26, Aug. 2012.
-
(2012)
IEEE Trans. Biomedical Eng
, vol.59
, Issue.8
, pp. 2219-2226
-
-
Witteveen, H.J.B.1
Droog, E.A.2
Rietman, J.S.3
Veltink, P.H.4
-
33
-
-
0348221966
-
Vibrotactile location on the arm: Effect of place, space and age
-
R.W. Cholewiak and A.A. Collins, "Vibrotactile Location on the Arm: Effect of Place, Space and Age," Perception and Psycophysics, vol. 65, pp. 1058-1077, 2003.
-
(2003)
Perception and Psycophysics
, vol.65
, pp. 1058-1077
-
-
Cholewiak, R.W.1
Collins, A.A.2
-
34
-
-
33750932030
-
Determining the feasibility of forearm mounted vibrotactile displays
-
I. Oakley, Y. Kim, J. Lee, and J. Ryu, "Determining the Feasibility of Forearm Mounted Vibrotactile Displays," Proc. 14th Symp. Haptic Interfaces for Virtual Environment and Teleoperator Systems, 2006.
-
(2006)
Proc. 14th Symp. Haptic Interfaces for Virtual Environment and Teleoperator Systems
-
-
Oakley, I.1
Kim, Y.2
Lee, J.3
Ryu, J.4
-
35
-
-
0019984979
-
Two-point discrimination assessment in the upper limb in young adult men and women
-
M.F. Nolan, "Two-Point Discrimination Assessment in the Upper Limb in Young Adult Men and Women," Physical Therapy, vol. 62, pp. 965-969, 1982.
-
(1982)
Physical Therapy
, vol.62
, pp. 965-969
-
-
Nolan, M.F.1
-
36
-
-
84859261134
-
Definition and synergies of cognitive info communications
-
B. Peter and A. Csapo, "Definition and Synergies of Cognitive Info communications," Acta Polytechnica Hungarica, vol. 9, no. 1, pp. 67-83, 2012.
-
(2012)
Acta Polytechnica Hungarica
, vol.9
, Issue.1
, pp. 67-83
-
-
Peter, B.1
Csapo, A.2
-
37
-
-
84859652369
-
Vibrotactile feed back for haptics and telemanipulation: Survey, concept and experiment
-
P. Galambos, "Vibrotactile Feed back for Haptics and Telemanipulation: Survey, Concept and Experiment," Acta Polytechnica Hungarica, vol. 9, no. 1, pp. 41-65, 2012.
-
(2012)
Acta Polytechnica Hungarica
, vol.9
, Issue.1
, pp. 41-65
-
-
Galambos, P.1
-
38
-
-
77955784624
-
Cognitive vision system for control of dexterous prosthetic hands: Experimental evaluation
-
Jan.
-
S. Dosen, C. Cipriani, M. Kostic, M. Controzzi, M.C. Carrozza, and D.B. Popovic, "Cognitive Vision System for Control of Dexterous Prosthetic Hands: Experimental Evaluation," J. NeuroEng. Rehabilitation, vol. 7, p. 42, Jan. 2010.
-
(2010)
J. NeuroEng. Rehabilitation
, vol.7
, pp. 42
-
-
Dosen, S.1
Cipriani, C.2
Kostic, M.3
Controzzi, M.4
Carrozza, M.C.5
Popovic, D.B.6
|