메뉴 건너뛰기




Volumn 19, Issue 5, 2011, Pages 483-489

Object discrimination with an artificial hand using electrical stimulation of peripheral tactile and proprioceptive pathways with intrafascicular electrodes

Author keywords

Amputee; intrafascicular electrodes; nerve stimulation; proprioception; prosthetic limb; touch

Indexed keywords

AMPUTEE; ARTIFICIAL HAND; AUDITORY CUES; CONTACT FORCES; ELECTRICAL STIMULATIONS; INTRAFASCICULAR ELECTRODES; NERVE STIMULATION; OBJECT DISCRIMINATION; PROSTHETIC HANDS; TACTILE SENSATION; TOUCH; ULNAR NERVES;

EID: 80054062765     PISSN: 15344320     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNSRE.2011.2162635     Document Type: Article
Times cited : (163)

References (51)
  • 1
    • 0030554768 scopus 로고    scopus 로고
    • Epidemiologic overview of individuals with upper-limb loss and their reported research priorities
    • D. J. Atkins, D. C. Y. Heard, and W. H. Donovan, "Epidemiologic overview of individuals with upper-limb loss and their reported research priorities," J. Prosthetics Orthotics, vol. 8, pp. 2-11, 1996.
    • (1996) J. Prosthetics Orthotics , vol.8 , pp. 2-11
    • Atkins, D.J.1    Heard, D.C.Y.2    Donovan, W.H.3
  • 2
    • 0019777265 scopus 로고
    • Training program for a myo-electrically controlled prosthesis with sensory feedback system
    • P. J. Agnew and G. F. Shannon, "Training program for a myo-electrically controlled prosthesis with sensory feedback system," Am. J. Occup. Ther., vol. 35, pp. 722-727, 1981.
    • (1981) Am. J. Occup. Ther. , vol.35 , pp. 722-727
    • Agnew, P.J.1    Shannon, G.F.2
  • 3
    • 0020587260 scopus 로고
    • Functional comparison of upper extremity amputees using myoelectric and conventional prostheses
    • R. B. Stein and M.Walley, "Functional comparison of upper extremity amputees using myoelectic and conventional prostheses," Arch. Phys. Med. Rehabil., vol. 64, pp. 243-248, 1983. (Pubitemid 13105571)
    • (1983) Archives of Physical Medicine and Rehabilitation , vol.64 , Issue.6 , pp. 243-248
    • Stein, R.B.1    Walley, M.2
  • 4
    • 0005725929 scopus 로고
    • Approaches to prescription of body-powered and myoelectric prostheses
    • H. H. Sears, "Approaches to prescription of body-powered and myoelectric prostheses," Prosthetics, vol. 2, pp. 361-371, 1991.
    • (1991) Prosthetics , vol.2 , pp. 361-371
    • Sears, H.H.1
  • 5
    • 4243966613 scopus 로고
    • Prostheses control and feedback via non-invasive skin and invasive peripheral nerve techniques
    • W. S. Fields, Ed. New York: Intercontinental Medical
    • R. W. Mann, "Prostheses control and feedback via non-invasive skin and invasive peripheral nerve techniques," in Neural Organization and Its Relevance to Prosthetics,W. S. Fields, Ed. New York: Intercontinental Medical, 1973, pp. 177-195.
    • (1973) Neural Organization and Its Relevance to Prosthetics , pp. 177-195
    • Mann, R.W.1
  • 6
    • 0016100050 scopus 로고
    • A sensory feedback system for an upper-limb amputation prosthesis
    • F. W. Clippinger, R. Avery, and B. R. Titus, "A sensory feedback system for an upper-limb amputation prosthesis," Bull. Prosthetics Res., vol. 10-22, pp. 247-258, 1974.
    • (1974) Bull. Prosthetics Res. , vol.10-22 , pp. 247-258
    • Clippinger, F.W.1    Avery, R.2    Titus, B.R.3
  • 7
    • 0016483763 scopus 로고
    • Sensory feedback for powered limb prostheses
    • T. A. Rohland, "Sensory feedback for powered limb prostheses," Med. Biol. Eng., vol. 12, pp. 300-301, 1975.
    • (1975) Med. Biol. Eng. , vol.12 , pp. 300-301
    • Rohland, T.A.1
  • 9
    • 80054080751 scopus 로고
    • An American Initiative: Workshop on upper extremity prosthetics
    • presented at, Houston, TX, NASA Johnson Space Center
    • An American Initiative: Workshop on upper extremity prosthetics," presented at the The Limbs of Love Foundation, Houston, TX, 1991, NASA Johnson Space Center.
    • (1991) The The Limbs of Love Foundation
  • 10
    • 0025973924 scopus 로고
    • Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle
    • Jan
    • P. E. Crago, R. J. Nakai, and H. J. Chizeck, "Feedback regulation of hand grasp opening and contact force during stimulation of paralyzed muscle," IEEE Trans. Biomed. Eng., vol. 38, no. 1, pp. 17-28, Jan. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.1 , pp. 17-28
    • Crago, P.E.1    Nakai, R.J.2    Chizeck, H.J.3
  • 11
    • 80054063056 scopus 로고
    • Research into the possibility of a substitute for proprioception
    • M. T. Carruthers and J. M. Pottinger, "Research into the possibility of a substitute for proprioception," Proc. Inst. Mech. Eng., vol. 183, pp. 98-102, 1969.
    • (1969) Proc. Inst. Mech. Eng. , vol.183 , pp. 98-102
    • Carruthers, M.T.1    Pottinger, J.M.2
  • 12
    • 2142713115 scopus 로고
    • Efferent and afferent control of an electromyographic, proportional-rate, force sensing artificial elbow with cutaneous display of joint angle
    • R. W. Mann, "Efferent and afferent control of an electromyographic, proportional-rate, force sensing artificial elbow with cutaneous display of joint angle," Proc. Inst. Mech. Eng., vol. 183, pp. 86-92, 1969.
    • (1969) Proc. Inst. Mech. Eng. , vol.183 , pp. 86-92
    • Mann, R.W.1
  • 13
    • 85069381869 scopus 로고
    • Sensory device for the artificial arm
    • presented at, Chicago, IL
    • O. Sueda and H. Tamura, "Sensory device for the artificial arm," presented at the 8th ACEMB, Chicago, IL, 1969.
    • (1969) The 8th ACEMB
    • Sueda, O.1    Tamura, H.2
  • 14
    • 0014751873 scopus 로고
    • Information transmission by phantom sensations
    • Mar
    • D. S. Alles, "Information transmission by phantom sensations," IEEE Trans. Man-Machine Syst., vol. 11, no. 1, pp. 85-91, Mar. 1970.
    • (1970) IEEE Trans. Man-Machine Syst. , vol.11 , Issue.1 , pp. 85-91
    • Alles, D.S.1
  • 15
    • 0016951961 scopus 로고
    • A comparison of alternative means of providing sensory feedback on upper limb prostheses
    • G. F. Shannon, "A comparison of alternative means of providing sensory feedback on upper limb prostheses," Med. Biol. Eng., vol. 14, pp. 289-293, 1976.
    • (1976) Med. Biol. Eng. , vol.14 , pp. 289-293
    • Shannon, G.F.1
  • 16
  • 17
    • 0018355380 scopus 로고
    • A myoelectrically-controlled prosthesis with sensory feedback
    • G. F. Shannon, "A myoelectrically-controlled prosthesis with sensory feedback," Med. Biol. Eng. Comput., vol. 17, pp. 73-80, 1979. (Pubitemid 9108396)
    • (1979) Medical and Biological Engineering and Computing , vol.17 , Issue.1 , pp. 73-80
    • Shannon, G.F.1
  • 18
    • 0023154439 scopus 로고
    • Signals in tactile afferents from the fingers eliciting adaptive motor responses during precision grip
    • R. S. Johansson and G. Westling, "Signals in tactile afferents from the fingers eliciting adaptive motor responses during precision grip," Exp. Brain Res., vol. 66, pp. 141-154, 1987. (Pubitemid 17039281)
    • (1987) Experimental Brain Research , vol.66 , Issue.1 , pp. 141-154
    • Johansson, R.S.1    Westling, G.2
  • 19
    • 0023143494 scopus 로고
    • Responses in glabrous skin mechanoreceptors during precision grip in humans
    • G. Westling and R. S. Johansson, "Responses in glabrous skin mechanoreceptors during precision grip in humans," Exp. Brain Res., vol. 66, pp. 128-140, 1987. (Pubitemid 17039280)
    • (1987) Experimental Brain Research , vol.66 , Issue.1 , pp. 128-140
    • Westling, G.1    Johansson, R.S.2
  • 20
    • 29644446048 scopus 로고
    • Evaluation of sensation apparatus for hand prosthesis and controllability of hand proshtesis
    • O. Sueda, "Evaluation of sensation apparatus for hand prosthesis and controllability of hand proshtesis," Biomechanisms, pp. 171-184, 1972.
    • (1972) Biomechanisms , pp. 171-184
    • Sueda, O.1
  • 21
    • 0019300990 scopus 로고
    • Closed-loop control in prosthetic systems: Historical perspective
    • DOI 10.1007/BF02363433
    • D. S. Childress, "Closed-loop control in prosthetic systems: Historical perspective," Ann. Biomed. Eng., vol. 8, pp. 293-303, 1980. (Pubitemid 11064542)
    • (1980) Annals of Biomedical Engineering , vol.8 , Issue.4-6 , pp. 293-303
    • Childress, D.S.1
  • 22
    • 0024676405 scopus 로고
    • Extended physiologic taction: Design and evaluation of a proportional force feedback system
    • S. G. Meek, S. C. Jacobsen, and P. P. Goulding, "Extended physiologic taction: Design and evaluation of a proportional force feedback system.," J. Rehabil. Res. Develop., vol. 26, pp. 53-62, 1989. (Pubitemid 19189051)
    • (1989) Journal of Rehabilitation Research and Development , vol.26 , Issue.3 , pp. 53-62
    • Meek, S.G.1    Jacobsen, S.C.2    Goulding, P.P.3
  • 23
    • 0027006830 scopus 로고
    • Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand
    • P. E. Patterson and J. A. Katz, "Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand," J. Rehab. Res. Develop., vol. 29, pp. 1-8, 1992.
    • (1992) J. Rehab. Res. Develop. , vol.29 , pp. 1-8
    • Patterson, P.E.1    Katz, J.A.2
  • 24
    • 0017521527 scopus 로고
    • Parameters of stimulation and perception in an artificial sensory feedback system
    • C. F.Walker, G. R. Lockhead, D. R. Markle, and J. H. McElhaney, "Parameters of stimulation and perception in an artificial sensory feedback system," J. Bioeng., vol. 1, pp. 251-260, 1977.
    • (1977) J. Bioeng. , vol.1 , pp. 251-260
    • Walker, C.F.1    Lockhead, G.R.2    Markle, D.R.3    McElhaney, J.H.4
  • 25
    • 0017516311 scopus 로고
    • Human ability to discriminate various parameters in afferent electrical nerve stimulation with particular reference to prostheses sensory feedback
    • A. B. Anani, K. Ikeda, and L. M. Korner, "Human ability to discriminate various parameters in afferent electrical nerve stimulation with particular reference to prostheses sensory feedback," Med. Biol. Eng. Comput., vol. 15, pp. 363-373, 1977. (Pubitemid 8145376)
    • (1977) Medical and Biological Engineering and Computing , vol.15 , Issue.4 , pp. 363-373
    • Anani, A.B.1    Ikeda, K.2    Korner, L.M.3
  • 26
    • 0024713867 scopus 로고
    • Orderly stimulation of skeletal muscle motor units with tripolar nerve cuff electrode
    • DOI 10.1109/10.30809
    • R. Baratta, M. Ichie, S. K.Hwang, and M. Solomonow, "Orderly stimulation of skeletal muscle motor units with tripolar nerve cuff electrode," IEEE Trans. Biomed. Eng., vol. 36, no. 8, pp. 836-843, Aug. 1989. (Pubitemid 19268578)
    • (1989) IEEE Transactions on Biomedical Engineering , vol.36 , Issue.8 , pp. 836-843
    • Baratta, R.1    Ichie, M.2    Hwang, S.K.3    Solomonow, M.4
  • 27
    • 0025453330 scopus 로고
    • A nerve cuff technique for selective excitation of peripheral nerve trunk regions
    • DOI 10.1109/10.55681
    • J. D. Sweeney, D. A. Ksienski, and J. T. Mortimer, "A nerve cuff technique for selective excitation of peripheral nerve trunk regions," IEEE Trans. Biomed. Eng., vol. 37, no. 7, pp. 706-715, Jul. 1990. (Pubitemid 20293271)
    • (1990) IEEE Transactions on Biomedical Engineering , vol.37 , Issue.7 , pp. 706-715
    • Sweeney, J.D.1    Ksienski, D.A.2    Mortimer, J.T.3
  • 28
    • 0026104684 scopus 로고
    • Selective activation of small motor axons by quasitrapezoidal current pulses
    • Feb
    • Z. Fang and J. T. Mortimer, "Selective activation of small motor axons by quasitrapezoidal current pulses," IEEE Trans. Biomed. Eng., vol. 38, no. 2, pp. 168-174, Feb. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.2 , pp. 168-174
    • Fang, Z.1    Mortimer, J.T.2
  • 32
    • 29644435231 scopus 로고    scopus 로고
    • Challenges to developing a neurally controlled upper limb prosthesis
    • K. W. Horch and G. S. Dhillon, Eds. Hackensack, NJ: World Scientific
    • G. S. Dhillon and S. Meek, "Challenges to developing a neurally controlled upper limb prosthesis," in Neuroprosthetics: Theory and Practice, K. W. Horch and G. S. Dhillon, Eds. Hackensack, NJ: World Scientific, 2004, pp. 1005-1034.
    • (2004) Neuroprosthetics: Theory and Practice , pp. 1005-1034
    • Dhillon, G.S.1    Meek, S.2
  • 33
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • DOI 10.1016/j.jhsa.2004.02.006, PII S0363502304002035
    • G. S. Dhillon, S. M. Lawrence, D. T. Hutchinson, and K. W. Horch, "Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs," J. Hand Surg., vol. 29A, pp. 605-615, 2004. (Pubitemid 38916703)
    • (2004) Journal of Hand Surgery , vol.29 , Issue.4 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 35
    • 12144251339 scopus 로고    scopus 로고
    • The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee
    • T. A. Kuiken, G. A. Dumanian, R. D. Lipschutz, L. A. Miller, and K. A. Stubblefield, "The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee," Prosthetics Orthotics Int., vol. 28, pp. 245-253, 2004. (Pubitemid 40103696)
    • (2004) Prosthetics and Orthotics International , vol.28 , Issue.3 , pp. 245-253
    • Kuiken, T.A.1    Dumanian, G.A.2    Lipschutz, R.D.3    Miller, L.A.4    Stubblefield, K.A.5
  • 36
    • 38049165433 scopus 로고    scopus 로고
    • Redirection of cutaneous sensation from the hand to the chest skin of human amputees with targeted reinnervation
    • T. A. Kuiken, P. D. Marasco, B. A. Lock, R. N. Harden, and J. P. A. Dewald, "Redirection of cutaneous sensation from the hand to the chest skin of human amputees with targeted reinnervation," Proc. Nat. Acad. Sci., vol. 104, pp. 20061-20066, 2007.
    • (2007) Proc. Nat. Acad. Sci. , vol.104 , pp. 20061-20066
    • Kuiken, T.A.1    Marasco, P.D.2    Lock, B.A.3    Harden, R.N.4    Dewald, J.P.A.5
  • 37
    • 34247563831 scopus 로고    scopus 로고
    • Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb
    • DOI 10.1016/j.jhsa.2007.02.021, PII S0363502307003048
    • X. Jia, M. A. Koenig, X. Zhang, J. Zhang, T. Chen, and Z. Chen, "Residual motor signal in long-term human severed peripheral nerves and feasibility of neural signal-controlled artificial limb," J. Hand Surgery, vol. 32, pp. 657-666, 2007. (Pubitemid 46680378)
    • (2007) Journal of Hand Surgery , vol.32 , Issue.5 , pp. 657-666
    • Jia, X.1    Koenig, M.A.2    Zhang, X.3    Zhang, J.4    Chen, T.5    Chen, Z.6
  • 39
    • 79952145177 scopus 로고    scopus 로고
    • Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
    • P. D. Marasco, K. Kim, J. E. Colgate, M. A. Peshkin, and T. A. Kuiken, "Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees," Brain, vol. 134, pp. 747-758, 2011.
    • (2011) Brain , vol.134 , pp. 747-758
    • Marasco, P.D.1    Kim, K.2    Colgate, J.E.3    Peshkin, M.A.4    Kuiken, T.A.5
  • 40
    • 17744366189 scopus 로고    scopus 로고
    • Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees
    • DOI 10.1152/jn.00937.2004
    • G. S. Dhillon, T. B. Krüger, J. S. Sandhu, and K. W. Horch, "Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees," J. Neurophysiol., vol. 93, pp. 2625-2633, 2005. (Pubitemid 40575748)
    • (2005) Journal of Neurophysiology , vol.93 , Issue.5 , pp. 2625-2633
    • Dhillon, G.S.1    Kruger, T.B.2    Sandhu, J.S.3    Horch, K.W.4
  • 41
    • 63049110933 scopus 로고    scopus 로고
    • Peripheral nervous system
    • K. W. Horch and G. S. Dhillon, Eds. Hackensack, NJ: World Scientific
    • K. W. Horch and P. R. Burgess, "Peripheral nervous system," in Neuroprosthetics: Theory and Practice, K. W. Horch and G. S. Dhillon, Eds. Hackensack, NJ: World Scientific, 2004, pp. 30-47.
    • (2004) Neuroprosthetics: Theory and Practice , pp. 30-47
    • Horch, K.W.1    Burgess, P.R.2
  • 42
    • 0020502320 scopus 로고
    • Peripheral projections of fascicles in the human median nerve
    • W. Schady, J. L. Ochoa, H. E. Torebjörk, and L. S. Chen, "Peripheral projections of fascicles in the human median nerve," Brain, vol. 106, pp. 745-760, 1983. (Pubitemid 13051171)
    • (1983) Brain , vol.106 , Issue.3 , pp. 745-760
    • Schady, W.1    Ochoa, J.L.2    Torebjork, H.E.3    Chen, L.S.4
  • 43
    • 0024320175 scopus 로고
    • An intrafascicular electrode for recording of action potentials in peripheral nerves
    • M. Malagodi, K. W. Horch, and A. A. Schoenberg, "An intrafascicular electrode for recording of action potentials in peripheral nerves," Ann. Biomed. Eng., vol. 17, pp. 397-410, 1989. (Pubitemid 19188602)
    • (1989) Annals of Biomedical Engineering , vol.17 , Issue.4 , pp. 397-410
    • Malagodi, M.S.1    Horch, K.W.2    Schoenberg, A.A.3
  • 45
    • 0027588996 scopus 로고
    • Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
    • DOI 10.1109/10.243412
    • K. Yoshida and K. Horch, "Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes," IEEE Trans. Biomed. Eng., vol. 40, no. 5, pp. 492-494, May 1993. (Pubitemid 24062923)
    • (1993) IEEE Transactions on Biomedical Engineering , vol.40 , Issue.5 , pp. 492-494
    • Yoshida, K.1    Horch, K.2
  • 46
    • 0030088097 scopus 로고    scopus 로고
    • Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation
    • DOI 10.1109/10.481986
    • K. Yoshida and K. Horch, "Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation," IEEE Trans. Biomed. Eng., vol. 43, no. 2, pp. 167-176, Feb. 1996. (Pubitemid 26055576)
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , Issue.2 , pp. 167-176
    • Yoshida, K.1    Horch, K.2
  • 47
    • 42249102924 scopus 로고    scopus 로고
    • Hybrid force-velocity sliding mode control of a prosthetic hand
    • DOI 10.1109/TBME.2007.914672
    • E. D. Engeberg, S. G. Meek, and M. A. Minor, "Hybrid force-velocity sliding mode control of a prosthetic hand," IEEE Trans. Biomed. Eng., vol. 55, no. 5, pp. 1572-1581, May 2008. (Pubitemid 351550723)
    • (2008) IEEE Transactions on Biomedical Engineering , vol.55 , Issue.5 , pp. 1572-1581
    • Engeberg, E.D.1    Meek, S.G.2    Minor, M.A.3
  • 48
    • 38049049791 scopus 로고    scopus 로고
    • A charge-balanced pulse generator for nerve stimulation applications
    • J. C. Gwilliam and K. Horch, "A charge-balanced pulse generator for nerve stimulation applications," J. Neurosci. Methods, vol. 168, pp. 146-150, 2008.
    • (2008) J. Neurosci. Methods , vol.168 , pp. 146-150
    • Gwilliam, J.C.1    Horch, K.2
  • 50
    • 0017211419 scopus 로고
    • Comparison of histologic and functional recovery after peripheral nerve repair
    • M. E. Jabaley, J. E. Burns, B. S. Orcutt, and W. M. Bryant, "Comparison of histologic and functional recovery after peripheral nerve repair," J. Hand Surg., vol. 1, pp. 119-30, 1976. (Pubitemid 8209691)
    • (1976) Journal of Hand Surgery , vol.1 , Issue.2 , pp. 119-130
    • Jabaley, M.E.1    Burns, J.E.2    Orcutt, B.S.3    Bryant, W.M.4
  • 51
    • 0035795974 scopus 로고    scopus 로고
    • Effect of sensory discrimination training on cortical reorganisation and phantom limb pain
    • DOI 10.1016/S0140-6736(00)04890-X
    • H. Flor, C. Denke, M. Schaefer, and S. Grüsser, "Effect of sensory discrimination training on cortical reorganisation and phantom limb pain," Lancet, vol. 357, pp. 1763-1764, 2001. (Pubitemid 32524209)
    • (2001) Lancet , vol.357 , Issue.9270 , pp. 1763-1764
    • Flor, H.1    Denke, C.2    Schaefer, M.3    Grusser, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.