메뉴 건너뛰기




Volumn 13, Issue 4, 2005, Pages 468-472

Direct neural sensory feedback and control of a prosthetic arm

Author keywords

Peripheral nerve implant; Prosthetic limb control; Sensory feedback

Indexed keywords

AMPUTEE'S PHANTOM HAND; NEURAL CONTROL; PERIPHERAL NERVE IMPLANTS; PROSTHETIC LIMB CONTROL;

EID: 29644439037     PISSN: 15344320     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNSRE.2005.856072     Document Type: Article
Times cited : (483)

References (38)
  • 1
    • 0030554768 scopus 로고    scopus 로고
    • Epidemiologic overview of individuals with upper-limb loss and their reported research priorities
    • D. J. Atkins, D. C. Y. Heard, and W. H. Donovan, "Epidemiologic overview of individuals with upper-limb loss and their reported research priorities," J. Prosthetics Orthotics, vol. 8, pp. 2-11, 1996.
    • (1996) J. Prosthetics Orthotics , vol.8 , pp. 2-11
    • Atkins, D.J.1    Heard, D.C.Y.2    Donovan, W.H.3
  • 4
    • 0016483763 scopus 로고
    • Sensory feedback for powered limb prostheses
    • T. A. Rohland, "Sensory feedback for powered limb prostheses," Med. Bio. Eng., vol. 12, pp. 300-301, 1975.
    • (1975) Med. Bio. Eng. , vol.12 , pp. 300-301
    • Rohland, T.A.1
  • 5
    • 0033366456 scopus 로고    scopus 로고
    • Does use of a myoelectric prosthesis prevent cortical reorganization and phantom limb pain?
    • M. Lotze, W. Grodd, N. Birbaumer, M. Erb, E. Huse, and H. Flor, "Does use of a myoelectric prosthesis prevent cortical reorganization and phantom limb pain?," Nature Neurosci., vol. 2, pp. 501-502, 1999.
    • (1999) Nature Neurosci. , vol.2 , pp. 501-502
    • Lotze, M.1    Grodd, W.2    Birbaumer, N.3    Erb, M.4    Huse, E.5    Flor, H.6
  • 6
    • 0026030113 scopus 로고
    • Proportional myoelectric hand control: An evaluation
    • H. H. Sears and J. Shaperman, "Proportional myoelectric hand control: An evaluation," Amer. J. Phys. Med. Rehabil., vol. 70, pp. 20-28, 1991.
    • (1991) Amer. J. Phys. Med. Rehabil. , vol.70 , pp. 20-28
    • Sears, H.H.1    Shaperman, J.2
  • 7
    • 0020587260 scopus 로고
    • Functional comparison of upper extremity amputees using myoelectic and conventional prostheses
    • R. B. Stein and M. Walley, "Functional comparison of upper extremity amputees using myoelectic and conventional prostheses," Arch. Phys. Med. Rehabil., vol. 64, pp. 243-248, 1983.
    • (1983) Arch. Phys. Med. Rehabil. , vol.64 , pp. 243-248
    • Stein, R.B.1    Walley, M.2
  • 8
    • 29644435231 scopus 로고    scopus 로고
    • Challenges to developing a neurally controlled upper limb prosthesis
    • K. W. Horch and G. S. Dhillon, Eds. Hackensack, NJ
    • G. S. Dhillon and S. Meek, "Challenges to developing a neurally controlled upper limb prosthesis," in Neuroprosthetics: Theory and Practice, K. W. Horch and G. S. Dhillon, Eds. Hackensack, NJ, 2004, pp. 1005-1034.
    • (2004) Neuroprosthetics: Theory and Practice , pp. 1005-1034
    • Dhillon, G.S.1    Meek, S.2
  • 9
    • 0029030038 scopus 로고
    • Phantom-limb pain as a perceptual correlate of cortical reorganization following arm amputation
    • H. Flor, T. Elbert, S. Knecht, C. Wienbruch, C. Pantev, N. Birbaumer, W. Larbig, and E. Taub, "Phantom-limb pain as a perceptual correlate of cortical reorganization following arm amputation," Nature, vol. 375, pp. 482-484, 1995.
    • (1995) Nature , vol.375 , pp. 482-484
    • Flor, H.1    Elbert, T.2    Knecht, S.3    Wienbruch, C.4    Pantev, C.5    Birbaumer, N.6    Larbig, W.7    Taub, E.8
  • 11
    • 0031885458 scopus 로고    scopus 로고
    • Cortical reorganization and phantom phenomena in congenital and traumatic upper-extremity amputees
    • H. Flor, T. Elbert, W. Mühlnickel, C. Pantev, C. Wienbruch, and E. Taub, "Cortical reorganization and phantom phenomena in congenital and traumatic upper-extremity amputees," Experimental Brain Res., vol. 119, pp. 205-212, 1998.
    • (1998) Experimental Brain Res. , vol.119 , pp. 205-212
    • Flor, H.1    Elbert, T.2    Mühlnickel, W.3    Pantev, C.4    Wienbruch, C.5    Taub, E.6
  • 12
    • 0035795974 scopus 로고    scopus 로고
    • Effect of sensory discrimination training on cortical reorganization and phantom limb pain
    • H. Flor, C. Denke, M. Schaefer, and S. Grüsser, "Effect of sensory discrimination training on cortical reorganization and phantom limb pain," Lancet, vol. 357, pp. 1763-1764, 2001.
    • (2001) Lancet , vol.357 , pp. 1763-1764
    • Flor, H.1    Denke, C.2    Schaefer, M.3    Grüsser, S.4
  • 13
    • 0016100050 scopus 로고
    • A sensory feedback system for an upper-limb amputation prosthesis
    • F. W. Clippinger, R. Avery, and B. R. Titus, "A sensory feedback system for an upper-limb amputation prosthesis," Bull. Prosthetics Res., vol. 10-22, pp. 247-258, 1974.
    • (1974) Bull. Prosthetics Res. , vol.10-22 , pp. 247-258
    • Clippinger, F.W.1    Avery, R.2    Titus, B.R.3
  • 14
    • 4243966613 scopus 로고
    • Prostheses control and feedback via noninvasive skin and invasive peripheral nerve techniques
    • W. S. Fields, Ed. New York: Intercontinental Medical
    • R. W. Mann, "Prostheses control and feedback via noninvasive skin and invasive peripheral nerve techniques," in Neural Organization and Its Relevance to Prosthetics, W. S. Fields, Ed. New York: Intercontinental Medical, 1973, pp. 177-195.
    • (1973) Neural Organization and Its Relevance to Prosthetics , pp. 177-195
    • Mann, R.W.1
  • 15
    • 0023708868 scopus 로고
    • Sensory feedback control of upper- and lower-ex-tremity motor prostheses
    • C. A. Phillips, "Sensory feedback control of upper- and lower-ex-tremity motor prostheses," CRC Critical Rev. Biomed. Eng., vol. 16, pp. 105-140, 1988.
    • (1988) CRC Critical Rev. Biomed. Eng. , vol.16 , pp. 105-140
    • Phillips, C.A.1
  • 16
    • 0016951961 scopus 로고
    • A comparison of alternative means of providing sensory feedback on upper limb prostheses
    • G. F. Shannon, "A comparison of alternative means of providing sensory feedback on upper limb prostheses," Med. Biol. Eng., vol. 14, pp. 289-293, 1976.
    • (1976) Med. Biol. Eng. , vol.14 , pp. 289-293
    • Shannon, G.F.1
  • 17
    • 0018355380 scopus 로고
    • A myoelectrically-controlled prosthesis with sensory feedback
    • -, "A myoelectrically-controlled prosthesis with sensory feedback," Med. Biol. Eng. Comput., vol. 17, pp. 73-80, 1979.
    • (1979) Med. Biol. Eng. Comput. , vol.17 , pp. 73-80
  • 18
    • 29644446048 scopus 로고
    • Evaluation of sensation apparatus for hand prosthesis and controllability of hand proshtesis
    • O. Sueda, "Evaluation of sensation apparatus for hand prosthesis and controllability of hand proshtesis," Biomechanisms, pp. 171-184, 1972.
    • (1972) Biomechanisms , pp. 171-184
    • Sueda, O.1
  • 19
    • 0017521527 scopus 로고
    • Parameters of stimulation and perception in an artificial sensory feedback system
    • C. F. Walker, G. R. Lockhead, D. R. Markle, and J. H. McElhaney, "Parameters of stimulation and perception in an artificial sensory feedback system," Journal of Bioengineering, vol. 1, pp. 251-260, 1977.
    • (1977) Journal of Bioengineering , vol.1 , pp. 251-260
    • Walker, C.F.1    Lockhead, G.R.2    Markle, D.R.3    McElhaney, J.H.4
  • 20
    • 12144251339 scopus 로고    scopus 로고
    • The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee
    • T. A. Kuiken, G. A. Dumanian, R. D. Lipschutz, L. A. Miller, and K. A. Stubblefield, "The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee," Prosthetics Orthotics Int., vol. 28, pp. 245-253, 2004.
    • (2004) Prosthetics Orthotics Int. , vol.28 , pp. 245-253
    • Kuiken, T.A.1    Dumanian, G.A.2    Lipschutz, R.D.3    Miller, L.A.4    Stubblefield, K.A.5
  • 21
    • 0345603127 scopus 로고    scopus 로고
    • Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode
    • S. M. Lawrence, G. S. Dhillon, and K. W. Horch, "Fabrication and characteristics of an implantable, polymer-based, intrafascicular electrode," J. Neurosci. Methods, vol. 131, pp. 9-26, 2003.
    • (2003) J. Neurosci. Methods , vol.131 , pp. 9-26
    • Lawrence, S.M.1    Dhillon, G.S.2    Horch, K.W.3
  • 22
    • 0024320175 scopus 로고
    • An intrafascicular electrode for recording of action potentials in peripheral nerves
    • M. Malagodi, K. W. Horch, and A. A. Schoenberg, "An intrafascicular electrode for recording of action potentials in peripheral nerves," Ann. Biomed. Eng., vol. 17, pp. 397-410, 1989.
    • (1989) Ann. Biomed. Eng. , vol.17 , pp. 397-410
    • Malagodi, M.1    Horch, K.W.2    Schoenberg, A.A.3
  • 23
    • 0030560821 scopus 로고    scopus 로고
    • Metallized polymer fibers as leadwires and intrafascicular microelectrodes
    • T. G. McNaughton and K. W. Horch, "Metallized polymer fibers as leadwires and intrafascicular microelectrodes," J. Neurosci. Methods, vol. 70, pp. 103-110, 1996.
    • (1996) J. Neurosci. Methods , vol.70 , pp. 103-110
    • McNaughton, T.G.1    Horch, K.W.2
  • 25
    • 0026229639 scopus 로고
    • Information contained in sensory nerve recordings made with intrafascicular electrodes
    • Sep.
    • E. V. Goodall, T. M. Lefurge, and K. W. Horch, "Information contained in sensory nerve recordings made with intrafascicular electrodes," IEEE Trans. Biomed. Eng., vol. 38, no. 9, pp. 846-850, Sep. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.9 , pp. 846-850
    • Goodall, E.V.1    Lefurge, T.M.2    Horch, K.W.3
  • 26
    • 0027588996 scopus 로고
    • Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
    • May
    • K. Yoshida and K. Horch, "Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes," IEEE Trans. Biomed. Eng., vol. 40, no. 5, pp. 492-494, May 1993.
    • (1993) IEEE Trans. Biomed. Eng. , vol.40 , Issue.5 , pp. 492-494
    • Yoshida, K.1    Horch, K.2
  • 27
    • 0030088097 scopus 로고    scopus 로고
    • Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation
    • Feb.
    • -, "Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation," IEEE Trans. Biomed. Eng., vol. 43, no. 2, pp. 167-176, Feb. 1996.
    • (1996) IEEE Trans. Biomed. Eng. , vol.43 , Issue.2 , pp. 167-176
  • 28
    • 0032201357 scopus 로고    scopus 로고
    • Recording properties and biocompatibility of chronically implanted polymer-based intrafascicular electrodes
    • J. A. Malmstrom, T. G. McNaughton, and K. W. Horch, "Recording properties and biocompatibility of chronically implanted polymer-based intrafascicular electrodes," Ann. Biomed. Eng., vol. 26, pp. 1055-1064, 1998.
    • (1998) Ann. Biomed. Eng. , vol.26 , pp. 1055-1064
    • Malmstrom, J.A.1    McNaughton, T.G.2    Horch, K.W.3
  • 29
    • 0036381714 scopus 로고    scopus 로고
    • Long-term biocompatibility of implanted polymer-based intrafascicular electrodes
    • S. M. Lawrence, J. O. Larsen, K. W. Horch, R. Riso, and T. Sinkjær, "Long-term biocompatibility of implanted polymer-based intrafascicular electrodes," J. Biomed. Materials Res., vol. 63, pp. 501-506, 2002.
    • (2002) J. Biomed. Materials Res. , vol.63 , pp. 501-506
    • Lawrence, S.M.1    Larsen, J.O.2    Horch, K.W.3    Riso, R.4    Sinkjær, T.5
  • 30
    • 3142743126 scopus 로고    scopus 로고
    • Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs
    • G. S. Dhillon, S. M. Lawrence, D. T. Hutchinson, and K. W. Horch, "Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs," J. Hand Surgery, vol. 29A, pp. 605-615, 2004.
    • (2004) J. Hand Surgery , vol.29 , pp. 605-615
    • Dhillon, G.S.1    Lawrence, S.M.2    Hutchinson, D.T.3    Horch, K.W.4
  • 31
    • 17744366189 scopus 로고    scopus 로고
    • Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees
    • G. S. Dhillon, T. B. Krüger, J. S. Sandhu, and K. W. Horch, "Effects of short-term training on sensory and motor function in severed nerves of long-term human amputees," J. Neurophysiol., vol. 93, pp. 2625-2633, 2005.
    • (2005) J. Neurophysiol. , vol.93 , pp. 2625-2633
    • Dhillon, G.S.1    Krüger, T.B.2    Sandhu, J.S.3    Horch, K.W.4
  • 36
    • 0031907813 scopus 로고    scopus 로고
    • Rapid plasticity of human cortical movement representation induced by practice
    • J. Classen, J. Liepert, S. P. Wise, M. Hallett, and L. G. Cohen, "Rapid plasticity of human cortical movement representation induced by practice," J. Neurophys., vol. 79, pp. 1117-1123, 1998.
    • (1998) J. Neurophys. , vol.79 , pp. 1117-1123
    • Classen, J.1    Liepert, J.2    Wise, S.P.3    Hallett, M.4    Cohen, L.G.5
  • 37
    • 0029122510 scopus 로고
    • Functional MRI evidence for adult motor cortex plasticity during motor skill learning
    • A. Karni, G. Meyer, P. Jezzard, M. M. Adams, R. Turner, and L. G. Ungerleider, "Functional MRI evidence for adult motor cortex plasticity during motor skill learning," Nature, vol. 377, pp. 155-158, 1995.
    • (1995) Nature , vol.377 , pp. 155-158
    • Karni, A.1    Meyer, G.2    Jezzard, P.3    Adams, M.M.4    Turner, R.5    Ungerleider, L.G.6
  • 38
    • 0029028097 scopus 로고
    • Modulation of muscle responses evoked by transcranial magnetic stimulation during the acquisition of new fine motor skills
    • A. Pascual-Leone, D. Nguyet, L. G. Cohen, J. P. Brasil-Neto, A. Cammarota, and M. Hallett, "Modulation of muscle responses evoked by transcranial magnetic stimulation during the acquisition of new fine motor skills," J. Neurophys., vol. 74, pp. 1037-1045, 1995.
    • (1995) J. Neurophys. , vol.74 , pp. 1037-1045
    • Pascual-Leone, A.1    Nguyet, D.2    Cohen, L.G.3    Brasil-Neto, J.P.4    Cammarota, A.5    Hallett, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.