Volumn 18, Issue 2, 2006, Pages 57-61

Design and evaluation of a low-cost force feedback system for myoelectric prosthetic hands

Author keywords

Closed loop control; Force feedback; Prosthetic hand; Sensor; Vibration

Indexed keywords


EID: 33749435189     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008526-200604000-00007     Document Type: Conference Paper
Times cited : (131)

References (22)
  • 2
    • 0034810174 scopus 로고    scopus 로고
    • Sensory substitution in prosthetics
    • Lundborg G, Rosén B. Sensory substitution in prosthetics. Hand Clinics 2001;3:481-488.
    • (2001) Hand Clinics , vol.3 , pp. 481-488
    • Lundborg, G.1    Rosén, B.2
  • 3
    • 0021348066 scopus 로고
    • Factors influencing the force control during precision grip
    • Westling G, Johansson RS. Factors influencing the force control during precision grip. Exp Brain Res 1984;53:277-284.
    • (1984) Exp Brain Res , vol.53 , pp. 277-284
    • Westling, G.1    Johansson, R.S.2
  • 4
    • 33749431305 scopus 로고    scopus 로고
    • Künstliches Glied. German patent application. No. DE301108, 1917
    • Rosset F. Künstliches Glied. German patent application. No. DE301108, 1917.
    • Rosset, F.1
  • 5
    • 0019300990 scopus 로고
    • Closed-loop control in prosthetic systems: Historical perspective
    • Childress DS. Closed-loop control in prosthetic systems: historical perspective. Ann Biomed Eng 1980;8:293-303.
    • (1980) Ann Biomed Eng , vol.8 , pp. 293-303
    • Childress, D.S.1
  • 6
    • 0025331555 scopus 로고
    • Feedback in myoelectric prostheses
    • Scott RN. Feedback in myoelectric prostheses. Clin Orthop Rel Res 1990;256:58-63.
    • (1990) Clin Orthop Rel Res , vol.256 , pp. 58-63
    • Scott, R.N.1
  • 7
    • 0016951961 scopus 로고
    • A comparison of alternative means of providing sensory feedback on upper limb prostheses
    • Shannon GF. A comparison of alternative means of providing sensory feedback on upper limb prostheses. Med Biol Eng 1976;14(3):289-294.
    • (1976) Med Biol Eng , vol.14 , Issue.3 , pp. 289-294
    • Shannon, G.F.1
  • 8
    • 0039401126 scopus 로고    scopus 로고
    • Multifunctional myoelectric hand prosthesis with pressure sensory feedback system, Waseda Hand 4P
    • Proceedings of the 3rd International Symposium on External Control of Human Extremities, Dubrovnik, Yugoslavia, August 25-30, 1969. Yugoslav Committee for Electronics and Automation (ETAN), Belgrade, Yugoslavia
    • Kato I, Yamakawa S, Ichikawa K, Sano M. Multifunctional myoelectric hand prosthesis with pressure sensory feedback system, Waseda Hand 4P. Proceedings of the 3rd International Symposium on External Control of Human Extremities, Dubrovnik, Yugoslavia, August 25-30, 1969. In: Advances in External Control on Human Extremities, Yugoslav Committee for Electronics and Automation (ETAN), Belgrade, Yugoslavia, 1970:155-170.
    • Advances in External Control on Human Extremities , vol.1970 , pp. 155-170
    • Kato, I.1    Yamakawa, S.2    Ichikawa, K.3    Sano, M.4
  • 9
    • 0017475077 scopus 로고
    • The importance of information feedback in prostheses for the upper limbs
    • Schmidl H. The importance of information feedback in prostheses for the upper limbs. Prosthet Orthot Int 1977;1:21-24.
    • (1977) Prosthet Orthot Int , vol.1 , pp. 21-24
    • Schmidl, H.1
  • 10
    • 0016068628 scopus 로고
    • Characteristics of a transducer for tactile displays
    • Shannon GF. Characteristics of a transducer for tactile displays. Biomed Eng 1974;9(6):247-249.
    • (1974) Biomed Eng , vol.9 , Issue.6 , pp. 247-249
    • Shannon, G.F.1
  • 14
    • 33749434858 scopus 로고    scopus 로고
    • Prosthetic device sensory attachment. US Patent application US2656545, 1953
    • Conzelmann JE, Ellis HB, O'Brian CW. Prosthetic device sensory attachment. US Patent application US2656545, 1953.
    • Conzelmann, J.E.1    Ellis, H.B.2    O'Brian, C.W.3
  • 16
    • 0027006830 scopus 로고
    • Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand
    • Patterson PE, Katz JA. Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand. J Rehabil Res Dev 1992;29(1):1-8.
    • (1992) J Rehabil Res Dev , vol.29 , Issue.1 , pp. 1-8
    • Patterson, P.E.1    Katz, J.A.2
  • 17
    • 33749449812 scopus 로고    scopus 로고
    • Method and apparatus for controlling an externally powered prosthesis. US Patent application US5888213, 1999
    • Sears HH, Iversen EK, Hays KB, Dyck AD. Method and apparatus for controlling an externally powered prosthesis. US Patent application US5888213, 1999.
    • Sears, H.H.1    Iversen, E.K.2    Hays, K.B.3    Dyck, A.D.4
  • 20
    • 33745254587 scopus 로고    scopus 로고
    • Determination of the grip force distribution in functional grasping
    • Kargov A, Pylatiuk C, Martin J, Schulz S. Determination of the grip force distribution in functional grasping. Technol Health Care 2004;12(2):193-194.
    • (2004) Technol Health Care , vol.12 , Issue.2 , pp. 193-194
    • Kargov, A.1    Pylatiuk, C.2    Martin, J.3    Schulz, S.4
  • 21
    • 84953647349 scopus 로고
    • Effect of contact or area on the vibrotactile threshold
    • Verillo RT. Effect of contact or area on the vibrotactile threshold. J Acoust Soc Am 1963;35(12):1962-1965.
    • (1963) J Acoust Soc Am , vol.35 , Issue.12 , pp. 1962-1965
    • Verillo, R.T.1
  • 22
    • 0018355380 scopus 로고
    • A myoelectrically-controlled prosthesis with sensory feedback
    • Shannon GF. A myoelectrically-controlled prosthesis with sensory feedback. Med Biol Eng Comput 1979;17(1):73-80.
    • (1979) Med Biol Eng Comput , vol.17 , Issue.1 , pp. 73-80
    • Shannon, G.F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.