메뉴 건너뛰기




Volumn 49, Issue 7, 2014, Pages 491-497

Comparing the image quality of a mobile flat-panel computed tomography and a multidetector computed tomography: A phantom study

Author keywords

cone beam CT; digital volume tomography; flat panel CT; image quality

Indexed keywords

ARTICLE; ARTIFACT; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; CONE BEAM COMPUTED TOMOGRAPHY; CONTRAST TO NOISE RATIO; IMAGE QUALITY; IMAGING PHANTOM; KIRSCHNER WIRE; MOBILE FLAT PANEL COMPUTED TOMOGRAPHY; MONTE CARLO METHOD; MULTIDETECTOR COMPUTED TOMOGRAPHY; PHANTOM; PRIORITY JOURNAL; RADIATION DOSE; SIMULATION; STATISTICAL ANALYSIS; COMPUTER AIDED DESIGN; COMPUTER SIMULATION; DEVICE FAILURE ANALYSIS; DEVICES; ELECTRONICS; EQUIPMENT DESIGN; EVALUATION STUDY; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; STATISTICAL MODEL; X RAY FILM;

EID: 84902209298     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0000000000000042     Document Type: Article
Times cited : (24)

References (36)
  • 1
    • 0038457603 scopus 로고    scopus 로고
    • Der einsatz von flachbilddetektoren für die CT-bildgebung
    • DOI 10.1007/s00117-003-0897-4
    • Kalender WA. The use of flat-panel detectors for CT imaging. Radiologe. 2003;43:379-387. (Pubitemid 36702362)
    • (2003) Radiologe , vol.43 , Issue.5 , pp. 379-387
    • Kalender, W.A.1
  • 3
    • 35349003753 scopus 로고    scopus 로고
    • Flat-detector computed tomography (FD-CT)
    • DOI 10.1007/s00330-007-0651-9
    • Kalender WA, Kyriakou Y. Flat-detector computed tomography (FD-CT). Eur Radiol. 2007;17:2767-2779. (Pubitemid 47603972)
    • (2007) European Radiology , vol.17 , Issue.11 , pp. 2767-2779
    • Kalender, W.A.1    Kyriakou, Y.2
  • 4
    • 52049117425 scopus 로고    scopus 로고
    • What is cone-beam CT and how does it work?
    • Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am. 2008;52:707-730, v.
    • (2008) Dent Clin North Am , vol.52 , pp. 707-730
    • Scarfe, W.C.1    Farman, A.G.2
  • 5
    • 54949157336 scopus 로고    scopus 로고
    • Musculoskeletal applications of flatpanel volume CT
    • Reichardt B, Sarwar A, Bartling SH, et al. Musculoskeletal applications of flatpanel volume CT. Skeletal Radiol. 2008;37:1069-1076.
    • (2008) Skeletal Radiol , vol.37 , pp. 1069-1076
    • Reichardt, B.1    Sarwar, A.2    Bartling, S.H.3
  • 6
    • 84859903931 scopus 로고    scopus 로고
    • Flat-panel CT arthrography: Feasibility study and comparison to multidetector CT arthrography
    • Guggenberger R, Fischer MA, Hodler J, et al. Flat-panel CT arthrography: feasibility study and comparison to multidetector CT arthrography. Invest Radiol. 2012;47:312-318.
    • (2012) Invest Radiol , vol.47 , pp. 312-318
    • Guggenberger, R.1    Fischer, M.A.2    Hodler, J.3
  • 7
    • 84874189529 scopus 로고    scopus 로고
    • C-Arm flat-panel CT arthrography of the wrist and elbow: First experiences in human cadavers
    • Guggenberger R, Morsbach F, Alkadhi H, et al. C-Arm flat-panel CT arthrography of the wrist and elbow: first experiences in human cadavers. Skeletal Radiol. 2013;42:419-429.
    • (2013) Skeletal Radiol , vol.42 , pp. 419-429
    • Guggenberger, R.1    Morsbach, F.2    Alkadhi, H.3
  • 8
    • 79961097997 scopus 로고    scopus 로고
    • A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization
    • Zbijewski W, De Jean P, Prakash P, et al. A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. Med Phys. 2011;38:4700-4713.
    • (2011) Med Phys , vol.38 , pp. 4700-4713
    • Zbijewski, W.1    De Jean, P.2    Prakash, P.3
  • 10
    • 84856287566 scopus 로고    scopus 로고
    • Cone-beam computed tomography: A new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique
    • De Cock J, Mermuys K, Goubau J, et al. Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique. Skeletal Radiol. 2012;41:93-96.
    • (2012) Skeletal Radiol , vol.41 , pp. 93-96
    • De Cock, J.1    Mermuys, K.2    Goubau, J.3
  • 13
    • 71049117748 scopus 로고    scopus 로고
    • SpekCalc: A program to calculate photon spectra from tungsten anode x-ray tubes
    • Poludniowski G, Landry G, DeBlois F, et al. SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes. Phys Med Biol. 2009;54: N433-N438.
    • (2009) Phys Med Biol , vol.54
    • Poludniowski, G.1    Landry, G.2    Deblois, F.3
  • 14
    • 77449106113 scopus 로고    scopus 로고
    • Realistic reference phantoms: An ICRP/ICRU joint effort: A report of adult reference computational phantoms
    • ICRP publication 110
    • Menzel HG, Clement C, DeLuca P. ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort: a report of adult reference computational phantoms. Ann ICRP. 2009;39:1-164.
    • (2009) Ann ICRP , vol.39 , pp. 1-164
    • Menzel, H.G.1    Clement, C.2    Deluca, P.3
  • 15
    • 40949104442 scopus 로고    scopus 로고
    • International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103
    • International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37:1-332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
  • 16
    • 84862694013 scopus 로고    scopus 로고
    • Comparison of spatial and contrast resolution for cone-beam computed tomography scanners
    • Pauwels R, Beinsberger J, Stamatakis H, et al. Comparison of spatial and contrast resolution for cone-beam computed tomography scanners. Oral Surg Oral Med Oral Pathol Oral Radiol. 2012;114:127-135.
    • (2012) Oral Surg Oral Med Oral Pathol Oral Radiol , vol.114 , pp. 127-135
    • Pauwels, R.1    Beinsberger, J.2    Stamatakis, H.3
  • 18
    • 79551537475 scopus 로고    scopus 로고
    • Digital volume tomography (DVT) and multislice spiral CT (MSCT): An objective examination of dose and image quality
    • Kyriakou Y, Kolditz D, Langner O, et al. Digital volume tomography (DVT) and multislice spiral CT (MSCT): an objective examination of dose and image quality. Rofo. 2011;183:144-153.
    • (2011) Rofo , vol.183 , pp. 144-153
    • Kyriakou, Y.1    Kolditz, D.2    Langner, O.3
  • 19
    • 84880309442 scopus 로고    scopus 로고
    • Vitro high-resolution flatpanel computed tomographic arthrography for artificial cartilage defect detection: Comparison with multidetector computed tomography
    • Guggenberger R, Winklhofer S, Spiczak JV, et al. In vitro high-resolution flatpanel computed tomographic arthrography for artificial cartilage defect detection: comparison with multidetector computed tomography. Invest Radiol. 2013;48:614-621.
    • (2013) Invest Radiol , vol.48 , pp. 614-621
    • Guggenberger, R.1    Winklhofer, S.2    Spiczak, J.V.3
  • 21
    • 79952171984 scopus 로고    scopus 로고
    • Experimental validation of a method characterizing bow tie filters in CT scanners using a real-Time dose probe
    • McKenney SE, Nosratieh A, Gelskey D, et al. Experimental validation of a method characterizing bow tie filters in CT scanners using a real-Time dose probe. Med Phys. 2011;38:1406-1415.
    • (2011) Med Phys , vol.38 , pp. 1406-1415
    • McKenney, S.E.1    Nosratieh, A.2    Gelskey, D.3
  • 22
    • 77953346524 scopus 로고    scopus 로고
    • Comparison of organ doses and image quality between CT and flat panel XperCT scans in wrist and inner ear examinations
    • Damet J, Sans-Merce M, Mieville F, et al. Comparison of organ doses and image quality between CT and flat panel XperCT scans in wrist and inner ear examinations. Radiat Prot Dosimetry. 2010;139:164-168.
    • (2010) Radiat Prot Dosimetry , vol.139 , pp. 164-168
    • Damet, J.1    Sans-Merce, M.2    Mieville, F.3
  • 23
    • 69949169325 scopus 로고    scopus 로고
    • Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications
    • Loubele M, Bogaerts R, Van Dijck E, et al. Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol. 2009;71:461-468.
    • (2009) Eur J Radiol , vol.71 , pp. 461-468
    • Loubele, M.1    Bogaerts, R.2    Van Dijck, E.3
  • 24
    • 5044251144 scopus 로고    scopus 로고
    • Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography
    • Schulze D, Heiland M, Thurmann H, et al. Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofac Radiol. 2004;33:83-86.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 83-86
    • Schulze, D.1    Heiland, M.2    Thurmann, H.3
  • 25
    • 84890107245 scopus 로고    scopus 로고
    • Assessment of effective radiation dose of an extremity CBCT MSCT and conventional X ray for knee area using MOSFET dosemeters
    • Koivisto J, Kiljunen T, Wolff J, et al. Assessment of effective radiation dose of an extremity CBCT, MSCT and conventional X ray for knee area using MOSFET dosemeters. Radiat Prot Dosimetry. 2013;157:515-524.
    • (2013) Radiat Prot Dosimetry , vol.157 , pp. 515-524
    • Koivisto, J.1    Kiljunen, T.2    Wolff, J.3
  • 26
    • 44149113722 scopus 로고    scopus 로고
    • C-Arm cone-beam CT: General principles and technical considerations for use in interventional radiology
    • Orth RC, Wallace MJ, Kuo MD. C-Arm cone-beam CT: general principles and technical considerations for use in interventional radiology. J Vasc Interv Radiol. 2008;19:814-820.
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 814-820
    • Orth, R.C.1    Wallace, M.J.2    Kuo, M.D.3
  • 27
    • 19744369868 scopus 로고    scopus 로고
    • Artifacts in CT: Recognition and avoidance
    • Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics. 2004;24:1679-1691.
    • (2004) Radiographics , vol.24 , pp. 1679-1691
    • Barrett, J.F.1    Keat, N.2
  • 28
    • 34347238633 scopus 로고    scopus 로고
    • Beam hardening artefacts occur in dental implant scans with the NewTom® cone beam CT but not with the dental 4-row multidetector CT
    • DOI 10.1259/dmfr/32579161
    • Draenert FG, Coppenrath E, Herzog P, et al. Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT. Dentomaxillofac Radiol. 2007;36:198-203. (Pubitemid 46999234)
    • (2007) Dentomaxillofacial Radiology , vol.36 , Issue.4 , pp. 198-203
    • Draenert, F.G.1    Coppenrath, E.2    Herzog, P.3    Muller, S.4    Mueller-Lisse, U.G.5
  • 30
    • 84862130696 scopus 로고    scopus 로고
    • Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: A systematically optimized protocol
    • Meinel FG, Bischoff B, Zhang Q, et al. Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: a systematically optimized protocol. Invest Radiol. 2012;47:406-414.
    • (2012) Invest Radiol , vol.47 , pp. 406-414
    • Meinel, F.G.1    Bischoff, B.2    Zhang, Q.3
  • 31
    • 77958483245 scopus 로고    scopus 로고
    • Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach
    • Prell D, Kyriakou Y, Kachelrie M, et al. Reducing metal artifacts in computed tomography caused by hip endoprostheses using a physics-based approach. Invest Radiol. 2010;45:747-754.
    • (2010) Invest Radiol , vol.45 , pp. 747-754
    • Prell, D.1    Kyriakou, Y.2    Kachelrie, M.3
  • 32
    • 0022880440 scopus 로고
    • On the determination of functions from their integral values along certain manifolds
    • Radon J. On the determination of functions from their integral values along certain manifolds. IEEE Trans Med Imaging. 1986;5:170-176. (Pubitemid 17517170)
    • (1986) IEEE Transactions on Medical Imaging , vol.MI-5 , Issue.4 , pp. 170-176
    • Radon Johann1
  • 34
    • 33745496524 scopus 로고    scopus 로고
    • X-ray computed tomography
    • DOI 10.1088/0031-9155/51/13/R03, PII S0031915506001369, R03
    • Kalender WA. X-ray computed tomography. Phys Med Biol. 2006;51:R29-R43. (Pubitemid 43958606)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.13
    • Kalender, W.A.1
  • 35
    • 84655176386 scopus 로고    scopus 로고
    • Investigation on the 3 D geometric accuracy and on the image quality (MTF, SNR and NPS) of volume tomography units (CT, CBCT and DVT)
    • Blendl C, Fiebich M, Voigt JM, et al. Investigation on the 3 D geometric accuracy and on the image quality (MTF, SNR and NPS) of volume tomography units (CT, CBCT and DVT). Rofo. 2012;184:24-31.
    • (2012) Rofo , vol.184 , pp. 24-31
    • Blendl, C.1    Fiebich, M.2    Voigt, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.