메뉴 건너뛰기




Volumn 200, Issue 1, 2013, Pages 146-148

Weight-bearing CT imaging of the lower extremity

Author keywords

Cone beam CT; Extremity; Joint; Weight bearing imaging

Indexed keywords

COMPUTED TOMOGRAPHY SCANNER; CONE BEAM COMPUTED TOMOGRAPHY; EQUIPMENT DESIGN; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; KNEE ARTHROPLASTY; LEG; MULTIDETECTOR COMPUTED TOMOGRAPHY; OSTEOARTHRITIS; PORTABLE EQUIPMENT; PRIORITY JOURNAL; RADIATION DOSE; SHORT SURVEY; STANDING; WEIGHT BEARING;

EID: 84871892780     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.12.8481     Document Type: Short Survey
Times cited : (106)

References (8)
  • 1
    • 79961097997 scopus 로고    scopus 로고
    • A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization
    • Zbijewski W, De Jean P, Prakash P, et al. A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. Med Phys 2011; 38:4700-4713
    • (2011) Med Phys , vol.38 , pp. 4700-4713
    • Zbijewski, W.1    De Jean, P.2    Prakash, P.3
  • 2
    • 84856287566 scopus 로고    scopus 로고
    • Cone-beam computed tomography: A new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique
    • De Cock J, Mermuys K, Goubau J, Van Petegem S, Houthoofd B, Casselman JW. Cone-beam computed tomography: a new low dose, high resolution imaging technique of the wrist, presentation of three cases with technique. Skeletal Radiol 2012; 41:93-96
    • (2012) Skeletal Radiol , vol.41 , pp. 93-96
    • De Cock, J.1    Mermuys, K.2    Goubau, J.3    Van Petegem, S.4    Houthoofd, B.5    Casselman, J.W.6
  • 3
    • 58149396296 scopus 로고    scopus 로고
    • Flatpanel volume CT: Fundamental principles, technology, and applications
    • Gupta R, Cheung AC, Bartling SH, et al. Flatpanel volume CT: fundamental principles, technology, and applications. RadioGraphics 2008; 28:2009-2022
    • (2008) RadioGraphics , vol.28 , pp. 2009-2022
    • Gupta, R.1    Cheung, A.C.2    Bartling, S.H.3
  • 5
    • 5044251144 scopus 로고    scopus 로고
    • Radiation exposure during midfacial imaging using 4- And 16-slice computed tomography, cone beam computed tomography systems and conventional radiography
    • Schulze D, Heiland M, Thurmann H, Adam G. Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofac Radiol 2004; 33:83-86
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 83-86
    • Schulze, D.1    Heiland, M.2    Thurmann, H.3    Adam, G.4
  • 6
    • 80053470473 scopus 로고    scopus 로고
    • Single bundle anterior cruciate reconstruction does not restore normal knee kinematics at six months: An upright MRI study
    • Nicholson JA, Sutherland AG, Smith FW. Single bundle anterior cruciate reconstruction does not restore normal knee kinematics at six months: an upright MRI study. J Bone Joint Surg Br 2011; 93-B:1334-1340
    • (2011) J Bone Joint Surg Br , vol.93 B , pp. 1334-1340
    • Nicholson, J.A.1    Sutherland, A.G.2    Smith, F.W.3
  • 7
    • 84864431514 scopus 로고    scopus 로고
    • Loading of the knee during 3.0T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis
    • Stehling C, Souza RB, Graverand MP, et al. Loading of the knee during 3.0T MRI is associated with significantly increased medial meniscus extrusion in mild and moderate osteoarthritis. Eur J Radiol 2012; 81:1839-1844
    • (2012) Eur J Radiol , vol.81 , pp. 1839-1844
    • Stehling, C.1    Souza, R.B.2    Graverand, M.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.