메뉴 건너뛰기




Volumn 11, Issue 6, 2014, Pages 943-955

Insulin pump therapy in youth with type 1 diabetes: Toward closed-loop systems

Author keywords

Bolus calculator; Bolus profile; Closed loop insulin delivery; Continuous glucose monitor; Control algorithm; Diabetes; Euglycemia; Insulin pump; Sensor augmented pump therapy; Smart pump; Suspend

Indexed keywords

INSULIN;

EID: 84901259795     PISSN: 17425247     EISSN: 17447593     Source Type: Journal    
DOI: 10.1517/17425247.2014.910192     Document Type: Review
Times cited : (15)

References (112)
  • 1
    • 0036897063 scopus 로고    scopus 로고
    • The rise of childhood type 1 diabetes in the 20th century
    • Gale EA. The rise of childhood type 1 diabetes in the 20th century. Diabetes 2002;51(12):3353-61
    • (2002) Diabetes , vol.51 , Issue.12 , pp. 3353-3361
    • Gale, E.A.1
  • 2
    • 33746548378 scopus 로고    scopus 로고
    • Incidence and trends of childhood type 1 diabetes worldwide 1990-1999
    • Group DP. Incidence and trends of childhood Type 1 diabetes worldwide 1990-1999. Diabet Med 2006;23(8):857-66
    • (2006) Diabet Med , vol.23 , Issue.8 , pp. 857-866
  • 3
    • 84870303140 scopus 로고    scopus 로고
    • Trends in childhood type 1 diabetes incidence in europe during 1989-2008: Evidence of non-uniformity over time in rates of increase
    • Patterson CC, Gyurus E, Rosenbauer J, et al. Trends in childhood type 1 diabetes incidence in Europe during 1989-2008: Evidence of non-uniformity over time in rates of increase. Diabetologia 2012;55(8):2142-7
    • (2012) Diabetologia , vol.55 , Issue.8 , pp. 2142-2147
    • Patterson, C.C.1    Gyurus, E.2    Rosenbauer, J.3
  • 5
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-Term complications in insulin-dependent diabetes mellitus
    • Group DCCT. The Diabetes Control and Complications Trial Research Group
    • Group DCCT. The effect of intensive treatment of diabetes on the development and progression of long-Term complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. N Engl J Med 1993;329(14):977-86
    • (1993) N Engl J Med , vol.329 , Issue.14 , pp. 977-986
  • 6
    • 57249098943 scopus 로고    scopus 로고
    • The barrier of hypoglycemia in Diabetes
    • Cryer PE. The barrier of hypoglycemia in Diabetes. Diabetes 2008;57(12):3169-76
    • (2008) Diabetes , vol.57 , Issue.12 , pp. 3169-3176
    • Cryer, P.E.1
  • 7
    • 0031014593 scopus 로고    scopus 로고
    • Hypoglycemia: Incidence and clinical predictors in a large population- based sample of children and adolescents with IDDM
    • Davis EA, Keating B, Byrne GC, et al. Hypoglycemia: Incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM. Diabetes Care 1997;20(1):22-5 (Pubitemid 27020036
    • (1997) Diabetes Care , vol.20 , Issue.1 , pp. 22-25
    • Davis, E.A.1    Keating, B.2    Byrne, G.C.3    Russell, M.4    Jones, T.W.5
  • 8
    • 0032914534 scopus 로고    scopus 로고
    • Neurocognitive functioning in children Diagnosed with diabetes before age 10 years
    • DOI 10.1016/S1056-8727(98)00029-4, PII S1056872798000294
    • Kaufman FR, Epport K, Engilman R, et al. Neurocognitive functioning in children Diagnosed with diabetes before age 10 years. J Diabetes Complications 1999;13(1):31-8 (Pubitemid 29195644
    • (1999) Journal of Diabetes and Its Complications , vol.13 , Issue.1 , pp. 31-38
    • Kaufman, F.R.1    Epport, K.2    Engilman, R.3    Halvorson, M.4
  • 9
    • 77954554880 scopus 로고    scopus 로고
    • Fear of hypoglycaemia in parents of young children with type 1 diabetes: A systematic review
    • Barnard K, Thomas S, Royle P, et al. Fear of hypoglycaemia in parents of young children with type 1 diabetes: A systematic review. BMC Pediatr 2010;10:50
    • (2010) BMC Pediatr , vol.10 , pp. 50
    • Barnard, K.1    Thomas, S.2    Royle, P.3
  • 10
    • 84882688633 scopus 로고    scopus 로고
    • Hypoglycaemia fear of hypoglycaemia and quality of life in children with type 1 diabetes and their parents
    • Johnson SR, Cooper MN, Davis EA, et al. Hypoglycaemia, fear of hypoglycaemia and quality of life in children with Type 1 diabetes and their parents. Diabet Med 2013;30(9):1126-31
    • (2013) Diabet Med , vol.30 , Issue.9 , pp. 1126-1131
    • Johnson, S.R.1    Cooper, M.N.2    Davis, E.A.3
  • 11
    • 84893103159 scopus 로고    scopus 로고
    • Alterations in white matter structure in young children with type 1 diabetes
    • Barnea-Goraly N, Raman M, Mazaika P, et al. Alterations in white matter structure in young children with type 1 diabetes. Diabetes Care 2014;37(2):332-40
    • (2014) Diabetes Care , vol.37 , Issue.2 , pp. 332-340
    • Barnea-Goraly, N.1    Raman, M.2    Mazaika, P.3
  • 12
    • 56149102506 scopus 로고    scopus 로고
    • Cognitive function in children with type 1 diabetes: A meta-Analysis
    • Gaudieri PA, Chen R, Greer TF, et al. Cognitive function in children with type 1 diabetes: A meta-Analysis. Diabetes Care 2008;31(9):1892-7
    • (2008) Diabetes Care , vol.31 , Issue.9 , pp. 1892-1897
    • Gaudieri, P.A.1    Chen, R.2    Greer, T.F.3
  • 13
    • 0027998781 scopus 로고
    • Effect of intensive diabetes treatment on the development and progression of long-Term complications in adolescents with insulindependent diabetes mellitus: Diabetes Control and Complications Trial
    • Group DCC.T.
    • Group DCCT. Effect of intensive diabetes treatment on the development and progression of long-Term complications in adolescents with insulindependent diabetes mellitus: Diabetes Control and Complications Trial. J Pediatr 1994;125(2):177-88
    • (1994) J Pediatr , vol.125 , Issue.2 , pp. 177-188
  • 14
    • 1542268655 scopus 로고    scopus 로고
    • Metabolic impact of puberty on the course of type 1 diabetes
    • Acerini CL, Williams RM, Dunger DB. Metabolic impact of puberty on the course of type 1 diabetes. Diabetes Metab 2001;27(4 Pt 2):S19-25
    • (2001) Diabetes Metab , vol.27 , Issue.4 PART 2
    • Acerini, C.L.1    Williams, R.M.2    Dunger, D.B.3
  • 15
    • 79959616082 scopus 로고    scopus 로고
    • Closed-loop insulin Delivery: From bench to clinical practice
    • Hovorka R. Closed-loop insulin Delivery: From bench to clinical practice. Nat Rev Endocrinol 2011;7(7):385-95
    • (2011) Nat Rev Endocrinol , vol.7 , Issue.7 , pp. 385-395
    • Hovorka, R.1
  • 16
    • 0018772709 scopus 로고
    • Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump
    • Tamborlane WV, Sherwin RS, Genel M, et al. Reduction to normal of plasma glucose in juvenile diabetes by subcutaneous administration of insulin with a portable infusion pump. N Engl J Med 1979;300(11):573-8 (Pubitemid 9123116
    • (1979) New England Journal of Medicine , vol.300 , Issue.11 , pp. 573-578
    • Tamborlane, W.V.1    Sherwin, R.S.2    Genel, M.3    Felig, P.4
  • 17
    • 84860116942 scopus 로고    scopus 로고
    • Insulin-pump therapy for type 1 diabetes mellitus
    • Pickup JC. Insulin-pump therapy for type 1 diabetes mellitus. N Engl J Med 2012;366(17):1616-24
    • (2012) N Engl J Med , vol.366 , Issue.17 , pp. 1616-1624
    • Pickup, J.C.1
  • 18
    • 77955743980 scopus 로고    scopus 로고
    • The use of insulin pumps in youth with type 1 diabetes
    • Maahs DM, Horton LA, Chase HP. The use of insulin pumps in youth with type 1 diabetes. Diabetes Technol Ther 2010;12(Suppl 1):S59-65
    • (2010) Diabetes Technol Ther , vol.12 , Issue.SUPPL. 1
    • Maahs, D.M.1    Horton, L.A.2    Chase, H.P.3
  • 19
    • 14644430260 scopus 로고    scopus 로고
    • Persistence of benefits of continuous subcutaneous insulin infusion in very young children with type 1 diabetes: A follow-up report
    • DOI 10.1542/peds.2004-0092
    • Weinzimer SA, Ahern JH, Doyle EA, et al. Persistence of benefits of continuous subcutaneous insulin infusion in very young children with type 1 diabetes: A follow-up report. Pediatrics 2004;114(6):1601-5 (Pubitemid 41754924
    • (2004) Pediatrics , vol.114 , Issue.6 , pp. 1601-1605
    • Weinzimer, S.A.1    Ahern, J.H.2    Doyle, E.A.3    Vincent, M.R.4    Dziura, J.5    Steffen, A.T.6    Tamborlane, W.V.7
  • 20
    • 77950902799 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus
    • Misso ML, Egberts KJ, Page M, et al. Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochrane Database Syst Rev 2010(1):Cd005103
    • (2010) Cochrane Database Syst Rev , vol.1
    • Misso, M.L.1    Egberts, K.J.2    Page, M.3
  • 21
    • 49649112407 scopus 로고    scopus 로고
    • Severe hypoglycaemia and glycaemic control in Type 1 diabetes: Meta-Analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion
    • Pickup JC, Sutton AJ. Severe hypoglycaemia and glycaemic control in Type 1 diabetes: Meta-Analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabet Med 2008;25(7):765-74
    • (2008) Diabet Med , vol.25 , Issue.7 , pp. 765-774
    • Pickup, J.C.1    Sutton, A.J.2
  • 22
    • 70349570168 scopus 로고    scopus 로고
    • Insulin treatment in children and adolescents with diabetes
    • Bangstad HJ, Danne T, Deeb L, et al. Insulin treatment in children and adolescents with diabetes. Pediatr Diabetes 2009;10(Suppl 12):82-99
    • (2009) Pediatr Diabetes , vol.10 , Issue.SUPPL. 12 , pp. 82-99
    • Bangstad, H.J.1    Danne, T.2    Deeb, L.3
  • 23
    • 65549158249 scopus 로고    scopus 로고
    • Investigation of quality of life and family burden issues during insulin pump therapy in children with Type 1 diabetes mellitus-A large-scale multicentre pilot study
    • Muller-Godeffroy E, Treichel S, Wagner VM. Investigation of quality of life and family burden issues during insulin pump therapy in children with Type 1 diabetes mellitus-A large-scale multicentre pilot study. Diabet Med 2009;26(5):493-501
    • (2009) Diabet Med , vol.26 , Issue.5 , pp. 493-501
    • Muller-Godeffroy, E.1    Treichel, S.2    Wagner, V.M.3
  • 24
    • 3042838907 scopus 로고    scopus 로고
    • A randomized, prospective trial comparing the efficacy of continuous subcutaneous insulin infusion with multiple daily injections using insulin glargine
    • DOI 10.2337/diacare.27.7.1554
    • Doyle EA, Weinzimer SA, Steffen AT, et al. A randomized, prospective trial comparing the efficacy of continuous subcutaneous insulin infusion with multiple daily injections using insulin glargine. Diabetes Care 2004;27(7):1554-8 (Pubitemid 38857425
    • (2004) Diabetes Care , vol.27 , Issue.7 , pp. 1554-1558
    • Doyle, E.A.1    Weinzimer, S.A.2    Steffen, A.T.3    Ahern, J.A.H.4    Vincent, M.5    Tamborlane, W.V.6
  • 25
    • 0042338756 scopus 로고    scopus 로고
    • Comparison of continuous subcutaneous insulin infusion and multiple daily injection regimens in children with type 1 diabetes: A randomized open crossover trial
    • DOI 10.1542/peds.112.3.559
    • Weintrob N, Benzaquen H, Galatzer A, et al. Comparison of continuous subcutaneous insulin infusion and multiple daily injection regimens in children with type 1 diabetes: A randomized open crossover trial. Pediatrics 2003;112(3 Pt 1):559-64 (Pubitemid 37082107
    • (2003) Pediatrics , vol.112 , Issue.3 , pp. 559-564
    • Weintrob, N.1    Benzaquen, H.2    Galatzer, A.3    Shalitin, S.4    Lazar, L.5    Fayman, G.6    Lilos, P.7    Dickerman, Z.8    Phillip, M.9
  • 26
    • 77950813140 scopus 로고    scopus 로고
    • Clinical effectiveness and costeffectiveness of continuous subcutaneous insulin infusion for diabetes: Systematic review and economic evaluation
    • ii-v xi-xvi
    • Cummins E, Royle P, Snaith A, et al. Clinical effectiveness and costeffectiveness of continuous subcutaneous insulin infusion for diabetes: Systematic review and economic evaluation. Health Technol Assess 2010;14(11):iii-v; xi-xvi, 1-181
    • (2010) Health Technol Assess , vol.14 , Issue.11 , pp. 1-181
    • Cummins, E.1    Royle, P.2    Snaith, A.3
  • 27
    • 59149106775 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion vs. Multiple daily injections in children with type 1 diabetes: A systematic review and meta-Analysis of randomized control trials
    • Pańkowska E, Błazik M, Dziechciarz P, et al. Continuous subcutaneous insulin infusion vs. multiple daily injections in children with type 1 diabetes: A systematic review and meta-Analysis of randomized control trials. Pediatr Diabetes 2009;10(1):52-8
    • (2009) Pediatr Diabetes , vol.10 , Issue.1 , pp. 52-58
    • Pańkowska, E.1    Błazik, M.2    Dziechciarz, P.3
  • 28
    • 84868112851 scopus 로고    scopus 로고
    • Comparative effectiveness and safety of methods of insulin Delivery and glucose monitoring for diabetes mellitus a systematic review and meta-Analysis
    • Yeh HC, Brown TT, Maruthur N, et al. Comparative effectiveness and safety of methods of insulin Delivery and glucose monitoring for diabetes mellitus: A systematic review and meta-Analysis. Ann Intern Med 2012;157(5):336-47
    • (2012) Ann Intern Med , vol.157 , Issue.5 , pp. 336-347
    • Yeh, H.C.1    Brown, T.T.2    Maruthur, N.3
  • 29
    • 33644878176 scopus 로고    scopus 로고
    • Age-specific advantages of continuous subcutaneous insulin infusion as compared with multiple daily injections in pediatric patients
    • Kordonouri O, Hartmann R, Lauterborn R, et al. Age-specific advantages of continuous subcutaneous insulin infusion as compared with multiple daily injections in pediatric patients: One-year follow-up comparison by matched-pair analysis. Diabetes Care 2006;29(1):133-4 (Pubitemid 44033444
    • (2006) Diabetes Care , vol.29 , Issue.1 , pp. 133-134
    • Kordonouri, O.1    Hartmann, R.2    Lauterborn, R.3    Barnekow, C.4    Hoeffe, J.5    Deiss, D.6
  • 30
    • 84885843485 scopus 로고    scopus 로고
    • Long-Term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study
    • Johnson SR, Cooper MN, Jones TW, et al. Long-Term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study. Diabetologia 2013;56(11):2392-400
    • (2013) Diabetologia , vol.56 , Issue.11 , pp. 2392-2400
    • Johnson, S.R.1    Cooper, M.N.2    Jones, T.W.3
  • 31
    • 65549110626 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion (CSII) 30 years later: Still the best option for insulin therapy
    • Bruttomesso D, Costa S, Baritussio A. Continuous subcutaneous insulin infusion (CSII) 30 years later: Still the best option for insulin therapy. Diabetes Metab Res Rev 2009;25(2):99-111
    • (2009) Diabetes Metab Res Rev , vol.25 , Issue.2 , pp. 99-111
    • Bruttomesso, D.1    Costa, S.2    Baritussio, A.3
  • 32
    • 84869080901 scopus 로고    scopus 로고
    • Insulin infusion set: The Achilles heel of continuous subcutaneous insulin infusion
    • Heinemann L, Krinelke L. Insulin infusion set: The Achilles heel of continuous subcutaneous insulin infusion. J Diabetes Sci Technol 2012;6(4):954-64
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.4 , pp. 954-964
    • Heinemann, L.1    Krinelke, L.2
  • 33
    • 77956140821 scopus 로고    scopus 로고
    • Insulin pump therapy: What is the evidence for using different types of boluses for coverage of prandial insulin requirements?
    • Heinemann L. Insulin pump therapy: What is the evidence for using different types of boluses for coverage of prandial insulin requirements?. J Diabetes Sci Technol 2009;3(6):1490-500
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.6 , pp. 1490-1500
    • Heinemann, L.1
  • 34
    • 17844384260 scopus 로고    scopus 로고
    • Optimal insulin pump dosing and postprandial glycemia following a pizza meal using the continuous glucose monitoring system
    • DOI 10.1089/dia.2005.7.233
    • Jones SM, Quarry JL, Caldwell-McMillan M, et al. Optimal insulin pump dosing and postprandial glycemia following a pizza meal using the continuous glucose monitoring system. Diabetes Technol Ther 2005;7(2):233-40 (Pubitemid 40586366
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.2 , pp. 233-240
    • Jones, S.M.1    Quarry, J.L.2    Caldwell-Mcmillan, M.3    Mauger, D.T.4    Gabbay, R.A.5
  • 35
    • 49649085126 scopus 로고    scopus 로고
    • Optimizing postprandial glycemia in pediatric patients with type 1 diabetes using insulin pump therapy: Impact of glycemic index and prandial bolus type
    • O'Connell MA, Gilbertson HR, Donath SM, et al. Optimizing postprandial glycemia in pediatric patients with type 1 diabetes using insulin pump therapy: Impact of glycemic index and prandial bolus type. Diabetes Care 2008;31(8):1491-5
    • (2008) Diabetes Care , vol.31 , Issue.8 , pp. 1491-1495
    • O'Connell, M.A.1    Gilbertson, H.R.2    Donath, S.M.3
  • 36
    • 77955810450 scopus 로고    scopus 로고
    • Many patients with Type 1 diabetes estimate their prandial insulin need inappropriately
    • Ahola AJ, Makimattila S, Saraheimo M, et al. Many patients with Type 1 diabetes estimate their prandial insulin need inappropriately. J Diabetes 2010;2(3):194-202
    • (2010) J Diabetes , vol.2 , Issue.3 , pp. 194-202
    • Ahola, A.J.1    Makimattila, S.2    Saraheimo, M.3
  • 37
    • 84891848271 scopus 로고    scopus 로고
    • Use of an insulin bolus advisor improves glycemic control in multiple daily insulin injection (mdi) therapy patients with suboptimal glycemic control: First results from the abacus trial
    • Ziegler R, Cavan DA, Cranston I, et al. Use of an insulin bolus advisor improves glycemic control in multiple daily insulin injection (MDI) therapy patients with suboptimal glycemic control: First results from the ABACUS trial. Diabetes Care 2013;36(11):3613-19
    • (2013) Diabetes Care , vol.36 , Issue.11 , pp. 3613-3619
    • Ziegler, R.1    Cavan, D.A.2    Cranston, I.3
  • 38
    • 84898879918 scopus 로고    scopus 로고
    • Carbohydrate counting with an automated bolus calculator helps to improve glycaemic control in children with type 1 diabetes using multiple daily injection therapy: An 18-month observational study
    • doi:10.1016/j.diabres.2013.12.026
    • Rabbone I, Scaramuzza AE, Ignaccolo MG, et al. Carbohydrate counting with an automated bolus calculator helps to improve glycaemic control in children with type 1 diabetes using multiple daily injection therapy: An 18-month observational study. Diabetes Res Clin Pract 2014, doi:10.1016/j.diabres.2013. 12.026
    • (2014) Diabetes Res Clin Pract
    • Rabbone, I.1    Scaramuzza, A.E.2    Ignaccolo, M.G.3
  • 39
    • 50649113918 scopus 로고    scopus 로고
    • Benefits of a bolus calculator in pre- and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII
    • Shashaj B, Busetto E, Sulli N. Benefits of a bolus calculator in pre- And postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII). Diabet Med 2008;25(9):1036-42
    • (2008) Diabet Med , vol.25 , Issue.9 , pp. 1036-1042
    • Shashaj, B.1    Busetto, E.2    Sulli, N.3
  • 40
    • 84868209391 scopus 로고    scopus 로고
    • Carbohydrate counting with a bolus calculator improves post-prandial blood glucose levels in children and adolescents with type 1 diabetes using insulin pumps
    • Enander R, Gundevall C, Stromgren A, et al. Carbohydrate counting with a bolus calculator improves post-prandial blood glucose levels in children and adolescents with type 1 diabetes using insulin pumps. Pediatr Diabetes 2012;13(7):545-51
    • (2012) Pediatr Diabetes , vol.13 , Issue.7 , pp. 545-551
    • Enander, R.1    Gundevall, C.2    Stromgren, A.3
  • 41
    • 84893516885 scopus 로고    scopus 로고
    • Bolus calculator and wirelessly communicated blood glucose meter effectively reduce hypoglycemia in type 1 diabetic children - Randomized controlled trial
    • Ramotowska A, Szypowska A. Bolus calculator and wirelessly communicated blood glucose meter effectively reduce hypoglycemia in type 1 diabetic children - randomized controlled trial. Diabetes Metab Res Rev 2014;30(2):146-53
    • (2014) Diabetes Metab Res Rev , vol.30 , Issue.2 , pp. 146-153
    • Ramotowska, A.1    Szypowska, A.2
  • 42
    • 49049113124 scopus 로고    scopus 로고
    • Electrochemical glucose sensors and their applications in Diabetes management
    • Heller A, Feldman B. Electrochemical glucose sensors and their applications in Diabetes management. Chem Rev 2008;108(7):2482-505
    • (2008) Chem Rev , vol.108 , Issue.7 , pp. 2482-2505
    • Heller, A.1    Feldman, B.2
  • 43
    • 62449126447 scopus 로고    scopus 로고
    • Glucose sensors: A review of current and emerging technology
    • Oliver NS, Toumazou C, Cass AE, et al. Glucose sensors: A review of current and emerging technology. Diabet Med 2009;26(3):197-210
    • (2009) Diabet Med , vol.26 , Issue.3 , pp. 197-210
    • Oliver, N.S.1    Toumazou, C.2    Cass, A.E.3
  • 44
    • 84873801365 scopus 로고    scopus 로고
    • Acomparative effectiveness analysis of three continuous glucose monitors
    • Damiano ER, El-Khatib FH, Zheng H, et al. A comparative effectiveness analysis of three continuous glucose monitors. Diabetes Care 2013;36(2):251-9
    • (2013) Diabetes Care , vol.36 , Issue.2 , pp. 251-259
    • Damiano, E.R.1    El-Khatib, F.H.2    Zheng, H.3
  • 45
    • 84884562284 scopus 로고    scopus 로고
    • Anew-generation continuous glucose monitoring system: Improved accuracy and reliability compared with a previous-generation system
    • Christiansen M, Bailey T, Watkins E, et al. A new-generation continuous glucose monitoring system: Improved accuracy and reliability compared with a previous-generation system. Diabetes Technol Ther 2013;15(10):881-8
    • (2013) Diabetes Technol Ther , vol.15 , Issue.10 , pp. 881-888
    • Christiansen, M.1    Bailey, T.2    Watkins, E.3
  • 46
    • 84863298190 scopus 로고    scopus 로고
    • Accuracy of the enlite 6-day glucose sensor with guardian and veo calibration algorithms
    • Keenan DB, Mastrototaro JJ, Zisser H, et al. Accuracy of the Enlite 6-day glucose sensor with guardian and Veo calibration algorithms. Diabetes Technol Ther 2012;14(3):225-31
    • (2012) Diabetes Technol Ther , vol.14 , Issue.3 , pp. 225-231
    • Keenan, D.B.1    Mastrototaro, J.J.2    Zisser, H.3
  • 47
    • 27644544001 scopus 로고    scopus 로고
    • Accuracy of newer-generation home blood glucose meters in a diabetes research in children network (direcnet) inpatient exercise study
    • 675-80 discussion
    • Weinzimer SA, Beck RW, Chase HP, et al. Accuracy of newer-generation home blood glucose meters in a Diabetes Research in Children Network (DirecNet) inpatient exercise study. Diabetes Technol Ther 2005;7(5):675-80; discussion 81-3
    • (2005) Diabetes Technol Ther , vol.7 , Issue.5 , pp. 81-83
    • Weinzimer, S.A.1    Beck, R.W.2    Chase, H.P.3
  • 48
    • 84872303458 scopus 로고    scopus 로고
    • Continuous glucose monitoring in type 1 diabetes
    • Mauras N, Fox L, Englert K, et al. Continuous glucose monitoring in type 1 diabetes. Endocrine 2013;43(1):41-50
    • (2013) Endocrine , vol.43 , Issue.1 , pp. 41-50
    • Mauras, N.1    Fox, L.2    Englert, K.3
  • 49
    • 79960319709 scopus 로고    scopus 로고
    • Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: Metaanalysis of randomised controlled trials using individual patient data
    • Pickup JC, Freeman SC, Sutton AJ. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: Metaanalysis of randomised controlled trials using individual patient data. BMJ 2011;343:d3805
    • (2011) BMJ , vol.343
    • Pickup, J.C.1    Freeman, S.C.2    Sutton, A.J.3
  • 50
    • 84862668643 scopus 로고    scopus 로고
    • Continuous glucose monitoring systems for type 1 diabetes mellitus
    • Langendam M, Luijf YM, Hooft L, et al. Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev 2012(1):Cd008101
    • (2012) Cochrane Database Syst Rev , vol.1
    • Langendam, M.1    Luijf, Y.M.2    Hooft, L.3
  • 51
    • 54849147700 scopus 로고    scopus 로고
    • Continuous glucose monitoring and intensive treatment of type 1 diabetes
    • Tamborlane WV, Beck RW, Bode BW, et al. Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008;359(14):1464-76
    • (2008) N Engl J Med , vol.359 , Issue.14 , pp. 1464-1476
    • Tamborlane, W.V.1    Beck, R.W.2    Bode, B.W.3
  • 52
    • 79956192128 scopus 로고    scopus 로고
    • Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes
    • Battelino T, Phillip M, Bratina N, et al. Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 2011;34(4):795-800
    • (2011) Diabetes Care , vol.34 , Issue.4 , pp. 795-800
    • Battelino, T.1    Phillip, M.2    Bratina, N.3
  • 53
    • 84859040091 scopus 로고    scopus 로고
    • Arandomized clinical trial to assess the efficacy and safety of real-Time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to <10 years
    • Mauras N, Beck R, Xing D, et al. A randomized clinical trial to assess the efficacy and safety of real-Time continuous glucose monitoring in the management of type 1 diabetes in young children aged 4 to <10 years. Diabetes Care 2012;35(2):204-10
    • (2012) Diabetes Care , vol.35 , Issue.2 , pp. 204-210
    • Mauras, N.1    Beck, R.2    Xing, D.3
  • 54
    • 50049127632 scopus 로고    scopus 로고
    • Sensor-Augmented insulin pump therapy: Results of the first randomized treat-To-Target study
    • Hirsch IB, Abelseth J, Bode BW, et al. Sensor-Augmented insulin pump therapy: Results of the first randomized treat-To-Target study. Diabetes Technol Ther 2008;10(5):377-83
    • (2008) Diabetes Technol Ther , vol.10 , Issue.5 , pp. 377-383
    • Hirsch, I.B.1    Abelseth, J.2    Bode, B.W.3
  • 55
    • 72249116711 scopus 로고    scopus 로고
    • Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: The RealTrend study
    • Raccah D, Sulmont V, Reznik Y, et al. Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: The RealTrend study. Diabetes Care 2009;32(12):2245-50
    • (2009) Diabetes Care , vol.32 , Issue.12 , pp. 2245-2250
    • Raccah, D.1    Sulmont, V.2    Reznik, Y.3
  • 56
    • 84856407738 scopus 로고    scopus 로고
    • Effectiveness of sensor-Augmented pump therapy in children and adolescents with type 1 diabetes in the star 3 study
    • Slover RH, Welsh JB, Criego A, et al. Effectiveness of sensor-Augmented pump therapy in children and adolescents with type 1 diabetes in the STAR 3 study. Pediatr Diabetes 2012;13(1):6-11
    • (2012) Pediatr Diabetes , vol.13 , Issue.1 , pp. 6-11
    • Slover, R.H.1    Welsh, J.B.2    Criego, A.3
  • 57
    • 78649335825 scopus 로고    scopus 로고
    • Sensor-Augmented pump therapy from the diagnosis of childhood type 1 diabetes: Results of the paediatric onset study (onset) after 12 months of treatment
    • Kordonouri O, Pankowska E, Rami B, et al. Sensor-Augmented pump therapy from the diagnosis of childhood type 1 diabetes: Results of the Paediatric Onset Study (ONSET) after 12 months of treatment. Diabetologia 2010;53(12):2487-95
    • (2010) Diabetologia , vol.53 , Issue.12 , pp. 2487-2495
    • Kordonouri, O.1    Pankowska, E.2    Rami, B.3
  • 58
    • 84868213630 scopus 로고    scopus 로고
    • The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: A randomised controlled trial
    • Battelino T, Conget I, Olsen B, et al. The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: A randomised controlled trial. Diabetologia 2012;55(12):3155-62
    • (2012) Diabetologia , vol.55 , Issue.12 , pp. 3155-3162
    • Battelino, T.1    Conget, I.2    Olsen, B.3
  • 59
    • 84868198912 scopus 로고    scopus 로고
    • Sensor augmented pump therapy from onset of type 1 diabetes: Late follow-up results of the pediatric onset study
    • Kordonouri O, Hartmann R, Pankowska E, et al. Sensor augmented pump therapy from onset of type 1 diabetes: Late follow-up results of the Pediatric Onset Study. Pediatr Diabetes 2012;13(7):515-18
    • (2012) Pediatr Diabetes , vol.13 , Issue.7 , pp. 515-518
    • Kordonouri, O.1    Hartmann, R.2    Pankowska, E.3
  • 60
    • 84891859307 scopus 로고    scopus 로고
    • Effectiveness of early intensive therapy on beta-cell preservation in type 1 diabetes
    • Buckingham B, Beck RW, Ruedy KJ, et al. Effectiveness of early intensive therapy on beta-cell preservation in type 1 diabetes. Diabetes Care 2013;36(12):4030-5
    • (2013) Diabetes Care , vol.36 , Issue.12 , pp. 4030-4035
    • Buckingham, B.1    Beck, R.W.2    Ruedy, K.J.3
  • 61
    • 0036049068 scopus 로고    scopus 로고
    • Sweet dreams?.-nocturnal hypoglycemia in children with type 1 diabetes
    • Matyka KA. Sweet dreams?.-nocturnal hypoglycemia in children with type 1 diabetes. Pediatr Diabetes 2002;3(2):74-81
    • (2002) Pediatr Diabetes , vol.3 , Issue.2 , pp. 74-81
    • Matyka, K.A.1
  • 62
    • 82555164135 scopus 로고    scopus 로고
    • Insulin pump therapy with automated insulin suspension in response to hypoglycemia: Reduction in nocturnal hypoglycemia in those at greatest risk
    • Choudhary P, Shin J, Wang Y, et al. Insulin pump therapy with automated insulin suspension in response to hypoglycemia: Reduction in nocturnal hypoglycemia in those at greatest risk. Diabetes Care 2011;34(9):2023-5
    • (2011) Diabetes Care , vol.34 , Issue.9 , pp. 2023-2025
    • Choudhary, P.1    Shin, J.2    Wang, Y.3
  • 63
    • 80055028578 scopus 로고    scopus 로고
    • Prevention of hypoglycemia by using low glucose suspend function in sensor-Augmented pump therapy
    • Danne T, Kordonouri O, Holder M, et al. Prevention of hypoglycemia by using low glucose suspend function in sensor-Augmented pump therapy. Diabetes Technol Ther 2011;13(11):1129-34
    • (2011) Diabetes Technol Ther , vol.13 , Issue.11 , pp. 1129-1134
    • Danne, T.1    Kordonouri, O.2    Holder, M.3
  • 64
    • 84857865549 scopus 로고    scopus 로고
    • Reduction in Duration of hypoglycemia by automatic suspension of insulin Delivery: The in-clinic aspire study
    • Garg S, Brazg RL, Bailey TS, et al. Reduction in Duration of hypoglycemia by automatic suspension of insulin Delivery: The in-clinic ASPIRE study. Diabetes Technol Ther 2012;14(3):205-9
    • (2012) Diabetes Technol Ther , vol.14 , Issue.3 , pp. 205-209
    • Garg, S.1    Brazg, R.L.2    Bailey, T.S.3
  • 65
    • 84884610823 scopus 로고    scopus 로고
    • Effect of sensor-Augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: A randomized clinical trial
    • Ly TT, Nicholas JA, Retterath A, et al. Effect of sensor-Augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: A randomized clinical trial. JAMA 2013;310(12):1240-7
    • (2013) JAMA , vol.310 , Issue.12 , pp. 1240-1247
    • Ly, T.T.1    Nicholas, J.A.2    Retterath, A.3
  • 66
    • 84880274350 scopus 로고    scopus 로고
    • Threshold-based insulin-pump interruption for reduction of hypoglycemia
    • Bergenstal RM, Klonoff DC, Garg SK, et al. Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med 2013;369(3):224-32
    • (2013) N Engl J Med , vol.369 , Issue.3 , pp. 224-232
    • Bergenstal, R.M.1    Klonoff, D.C.2    Garg, S.K.3
  • 67
    • 84862867091 scopus 로고    scopus 로고
    • Analysis of glucose responses to automated insulin suspension with sensor-Augmented pump therapy
    • Ly TT, Nicholas JA, Retterath A, et al. Analysis of glucose responses to automated insulin suspension with sensor-Augmented pump therapy. Diabetes Care 2012;35(7):1462-5
    • (2012) Diabetes Care , vol.35 , Issue.7 , pp. 1462-1465
    • Ly, T.T.1    Nicholas, J.A.2    Retterath, A.3
  • 68
    • 0033329859 scopus 로고    scopus 로고
    • Comparison of metabolic deterioration between insulin analog and regular insulin after a 5-hour interruption of a continuous subcutaneous insulin infusion in type 1 diabetic patients
    • Guerci B, Meyer L, Salle A, et al. Comparison of metabolic deterioration between insulin analog and regular insulin after a 5-hour interruption of a continuous subcutaneous insulin infusion in type 1 diabetic patients. J Clin Endocrinol Metab 1999;84(8):2673-8 (Pubitemid 30641991
    • (1999) Journal of Clinical Endocrinology and Metabolism , vol.84 , Issue.8 , pp. 2673-2678
    • Guerci, B.1    Meyer, L.2    Salle, A.3    Charrie, A.4    Dousset, B.5    Ziegler, O.6    Drouin, P.7
  • 69
    • 77954939888 scopus 로고    scopus 로고
    • Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension
    • Buckingham B, Chase HP, Dassau E, et al. Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension. Diabetes Care 2010;33(5):1013-17
    • (2010) Diabetes Care , vol.33 , Issue.5 , pp. 1013-1017
    • Buckingham, B.1    Chase, H.P.2    Dassau, E.3
  • 70
    • 84882266788 scopus 로고    scopus 로고
    • Outpatient safety assessment of an in-home predictive lowglucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia
    • Buckingham BA, Cameron F, Calhoun P, et al. Outpatient safety assessment of an in-home predictive lowglucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia. Diabetes Technol Ther 2013;15(8):622-7
    • (2013) Diabetes Technol Ther , vol.15 , Issue.8 , pp. 622-627
    • Buckingham, B.A.1    Cameron, F.2    Calhoun, P.3
  • 71
    • 84901277235 scopus 로고    scopus 로고
    • In silico modeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise
    • The PILGRIM study Epub ahead of print]
    • Danne T, Tsioli C, Kordonouri O, et al. The PILGRIM study: In silico modeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise. Diabetes Technol Ther 2014. [Epub ahead of print]
    • (2014) Diabetes Technol Ther
    • Danne, T.1    Tsioli, C.2    Kordonouri, O.3
  • 72
    • 77950679236 scopus 로고    scopus 로고
    • Suspended insulin infusion during overnight closed-loop glucose control in children and adolescents with type 1 diabetes
    • Elleri D, Allen JM, Nodale M, et al. Suspended insulin infusion During overnight closed-loop glucose control in children and adolescents with Type 1 diabetes. Diabet Med 2010;27(4):480-4
    • (2010) Diabet Med , vol.27 , Issue.4 , pp. 480-484
    • Elleri, D.1    Allen, J.M.2    Nodale, M.3
  • 73
    • 0007424620 scopus 로고
    • Automation control of blood sugar i A servomechanism for glucose monitoring and control
    • Kadish AH. Automation control of blood sugar. I. A servomechanism for glucose monitoring and control. Am J Med Electron 1964;3:82-6
    • (1964) Am J Med Electron , vol.3 , pp. 82-86
    • Kadish, A.H.1
  • 74
    • 33751506973 scopus 로고    scopus 로고
    • Artificial beta-cell: Clinical experience toward an implantable closed-loop insulin Delivery system
    • DOI DM-12-2006-32-5-C2-1262-3636-101019-200609060
    • Renard E, Costalat G, Chevassus H, et al. Artificial beta-cell: Clinical experience toward an implantable closedloop insulin Delivery system. Diabetes Metab 2006;32(5 Pt 2):497-502 (Pubitemid 44836980
    • (2006) Diabetes and Metabolism , vol.32 C2 , pp. 497-502
    • Renard, E.1    Costalat, G.2    Chevassus, H.3    Bringer, J.4
  • 75
    • 33845521334 scopus 로고    scopus 로고
    • Feasibility of automating insulin Delivery for the treatment of type 1 diabetes
    • DOI 10.2337/db06-0419
    • Steil GM, Rebrin K, Darwin C, et al. Feasibility of automating insulin Delivery for the treatment of type 1 diabetes. Diabetes 2006;55(12):3344-50 (Pubitemid 44923591
    • (2006) Diabetes , vol.55 , Issue.12 , pp. 3344-3350
    • Steil, G.M.1    Rebrin, K.2    Darwin, C.3    Hariri, F.4    Saad, M.F.5
  • 76
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated closed-loop insulin Delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Weinzimer SA, Steil GM, Swan KL, et al. Fully automated closed-loop insulin Delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008;31(5):934-9
    • (2008) Diabetes Care , vol.31 , Issue.5 , pp. 934-939
    • Weinzimer, S.A.1    Steil, G.M.2    Swan, K.L.3
  • 77
    • 77249157244 scopus 로고    scopus 로고
    • Manual closed-loop insulin Delivery in children and adolescents with type 1 diabetes: A phase 2 randomised crossover trial
    • Hovorka R, Allen JM, Elleri D, et al. Manual closed-loop insulin Delivery in children and adolescents with type 1 diabetes: A phase 2 randomised crossover trial. Lancet 2010;375(9716):743-51
    • (2010) Lancet , vol.375 , Issue.9716 , pp. 743-751
    • Hovorka, R.1    Allen, J.M.2    Elleri, D.3
  • 78
    • 77954901769 scopus 로고    scopus 로고
    • Md-logic artificial pancreas system: A pilot study in adults with type 1 diabetes
    • Atlas E, Nimri R, Miller S, et al. MD-logic artificial pancreas system: A pilot study in adults with type 1 diabetes. Diabetes Care 2010;33(5):1072-6
    • (2010) Diabetes Care , vol.33 , Issue.5 , pp. 1072-1076
    • Atlas, E.1    Nimri, R.2    Miller, S.3
  • 79
    • 77952987107 scopus 로고    scopus 로고
    • Abihormonal closed-loop artificial pancreas for type 1 diabetes
    • 27ra27
    • El-Khatib FH, Russell SJ, Nathan DM, et al. A bihormonal closed-loop artificial pancreas for type 1 diabetes. Sci Transl Med 2010;2(27):27ra27
    • (2010) Sci Transl Med , vol.2 , pp. 27
    • El-Khatib, F.H.1    Russell, S.J.2    Nathan, D.M.3
  • 80
    • 2642657551 scopus 로고
    • Epidemiology of severe hypoglycemia in the diabetes control and complications trial
    • Group DCC.T.
    • Group DCCT. Epidemiology of severe hypoglycemia in the diabetes control and complications trial. Am J Med 1991;90(4):450-9
    • (1991) Am J Med , vol.90 , Issue.4 , pp. 450-459
  • 81
    • 84891759330 scopus 로고    scopus 로고
    • Neuroanatomical correlates of dysglycemia in young children with type 1 diabetes
    • Marzelli MJ, Mazaika PK, Barnea-Goraly N, et al. Neuroanatomical correlates of dysglycemia in young children with type 1 diabetes. Diabetes 2014;63(1):343-53
    • (2014) Diabetes , vol.63 , Issue.1 , pp. 343-353
    • Marzelli, M.J.1    Mazaika, P.K.2    Barnea-Goraly, N.3
  • 82
    • 75749140069 scopus 로고    scopus 로고
    • Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes
    • Elleri D, Acerini CL, Allen JM, et al. Parental attitudes towards overnight closed-loop glucose control in children with type 1 diabetes. Diabetes Technol Ther 2010;12(1):35-9
    • (2010) Diabetes Technol Ther , vol.12 , Issue.1 , pp. 35-39
    • Elleri, D.1    Acerini, C.L.2    Allen, J.M.3
  • 83
    • 80755148728 scopus 로고    scopus 로고
    • Artificial pancreas: Past present future
    • Cobelli C, Renard E, Kovatchev B. Artificial pancreas: Past, present, future. Diabetes 2011;60(11):2672-82
    • (2011) Diabetes , vol.60 , Issue.11 , pp. 2672-2682
    • Cobelli, C.1    Renard, E.2    Kovatchev, B.3
  • 84
    • 84868087308 scopus 로고    scopus 로고
    • The use of an automated portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes
    • O'Grady MJ, Retterath AJ, Keenan DB, et al. The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012;35(11):2182-7
    • (2012) Diabetes Care , vol.35 , Issue.11 , pp. 2182-2187
    • O'Grady, M.J.1    Retterath, A.J.2    Keenan, D.B.3
  • 85
    • 84888615573 scopus 로고    scopus 로고
    • Reduced hypoglycemia and increased time in target using closed-loop insulin Delivery during nights with or without antecedent afternoon exercise in type 1 diabetes
    • Sherr JL, Cengiz E, Palerm CC, et al. Reduced hypoglycemia and increased time in target using closed-loop insulin Delivery during nights with or without antecedent afternoon exercise in type 1 diabetes. Diabetes Care 2013;36(10):2909-14
    • (2013) Diabetes Care , vol.36 , Issue.10 , pp. 2909-2914
    • Sherr, J.L.1    Cengiz, E.2    Palerm, C.C.3
  • 86
    • 84876806368 scopus 로고    scopus 로고
    • The 'Glucositter' overnight automated closed loop system for type 1 diabetes: A randomized crossover trial
    • Nimri R, Danne T, Kordonouri O, et al. The 'Glucositter' overnight automated closed loop system for type 1 diabetes: A randomized crossover trial. Pediatr Diabetes 2013;14(3):159-67
    • (2013) Pediatr Diabetes , vol.14 , Issue.3 , pp. 159-167
    • Nimri, R.1    Danne, T.2    Kordonouri, O.3
  • 87
    • 84875461530 scopus 로고    scopus 로고
    • Closed-loop basal insulin Delivery over 36 hours in adolescents with type 1 diabetes: Randomized clinical trial
    • Elleri D, Allen JM, Kumareswaran K, et al. Closed-loop basal insulin Delivery over 36 hours in adolescents with type 1 diabetes: Randomized clinical trial. Diabetes Care 2013;36(4):838-44
    • (2013) Diabetes Care , vol.36 , Issue.4 , pp. 838-844
    • Elleri, D.1    Allen, J.M.2    Kumareswaran, K.3
  • 88
    • 84877639101 scopus 로고    scopus 로고
    • The effects of inpatient hybrid closed-loop therapy initiated within 1 week of type 1 diabetes diagnosis
    • Buckingham BA, Beck RW, Ruedy KJ, et al. The effects of inpatient hybrid closed-loop therapy initiated within 1 week of type 1 diabetes diagnosis. Diabetes Technol Ther 2013;15(5):401-8
    • (2013) Diabetes Technol Ther , vol.15 , Issue.5 , pp. 401-408
    • Buckingham, B.A.1    Beck, R.W.2    Ruedy, K.J.3
  • 89
    • 84873819299 scopus 로고    scopus 로고
    • Closed-loop insulin therapy improves glycemic control in children aged 7 years: A randomized controlled trial
    • Dauber A, Corcia L, Safer J, et al. Closed-loop insulin therapy improves glycemic control in children aged 7 years: A randomized controlled trial. Diabetes Care 2013;36(2):222-7
    • (2013) Diabetes Care , vol.36 , Issue.2 , pp. 222-227
    • Dauber, A.1    Corcia, L.2    Safer, J.3
  • 90
    • 84888432831 scopus 로고    scopus 로고
    • Closed loop developments to improve glucose control at home
    • Renard E, Cobelli C, Kovatchev BP. Closed loop developments to improve glucose control at home. Diabetes Res Clin Pract 2013;102(2):79-85
    • (2013) Diabetes Res Clin Pract , vol.102 , Issue.2 , pp. 79-85
    • Renard, E.1    Cobelli, C.2    Kovatchev, B.P.3
  • 91
    • 84874368884 scopus 로고    scopus 로고
    • Nocturnal glucose control with an artificial pancreas at a diabetes camp
    • Phillip M, Battelino T, Atlas E, et al. Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med 2013;368(9):824-33
    • (2013) N Engl J Med , vol.368 , Issue.9 , pp. 824-833
    • Phillip, M.1    Battelino, T.2    Atlas, E.3
  • 92
    • 84992268896 scopus 로고    scopus 로고
    • Feasibility of outpatient fully integrated closed-loop control: First studies of wearable artificial pancreas
    • Kovatchev BP, Renard E, Cobelli C, et al. Feasibility of outpatient fully integrated closed-loop control: First studies of wearable artificial pancreas. Diabetes Care 2013;36(7):1851-8
    • (2013) Diabetes Care , vol.36 , Issue.7 , pp. 1851-1858
    • Kovatchev, B.P.1    Renard, E.2    Cobelli, C.3
  • 93
    • 84896390985 scopus 로고    scopus 로고
    • Night glucose control with md-logic artificial pancreas in home setting: A single blind randomized crossover trial-interim analysis
    • Nimri R, Muller I, Atlas E, et al. Night glucose control with MD-Logic artificial pancreas in home setting: A single blind, randomized crossover trial-interim analysis. Pediatr Diabetes 2014;15(2):91-9
    • (2014) Pediatr Diabetes , vol.15 , Issue.2 , pp. 91-99
    • Nimri, R.1    Muller, I.2    Atlas, E.3
  • 94
    • 84899117172 scopus 로고    scopus 로고
    • Overnight closed loop insulin Delivery in young people with type 1 diabetes: A free-living randomised clinical trial
    • doi 10.2337/DC13-644
    • Hovorka R, Elleri D, Thabit H, et al. Overnight closed loop insulin Delivery in young people with type 1 diabetes: A free-living randomised clinical trial. Diabetes Care 2014, doi 10.2337/DC13-644
    • (2014) Diabetes Care
    • Hovorka, R.1    Elleri, D.2    Thabit, H.3
  • 95
    • 84887185415 scopus 로고    scopus 로고
    • Areview of artificial pancreas technologies with an emphasis on bihormonal therapy
    • Bakhtiani PA, Zhao LM, El Youssef J, et al. A review of artificial pancreas technologies with an emphasis on bihormonal therapy. Diabetes Obes Metab 2013;15(12):1065-70
    • (2013) Diabetes Obes Metab , vol.15 , Issue.12 , pp. 1065-1070
    • Bakhtiani, P.A.1    Zhao, L.M.2    El Youssef, J.3
  • 96
    • 84862501914 scopus 로고    scopus 로고
    • Management of diabetes mellitus: Is the pump mightier than the pen?
    • Pickup JC. Management of diabetes mellitus: Is the pump mightier than the pen?. Nat Rev Endocrinol 2012;8(7):425-33
    • (2012) Nat Rev Endocrinol , vol.8 , Issue.7 , pp. 425-433
    • Pickup, J.C.1
  • 97
    • 0036042661 scopus 로고    scopus 로고
    • Less severe hypoglycaemia, better metabolic control and improved quality of life in Type 1 diabetes mellitus with continuous subcutaneous insulin infusion (CSII) therapy; An observational study of 100 consecutive patients followed for a mean of 2 years
    • DOI 10.1046/j.1464-5491.2002.00713.x
    • Linkeschova R, Raoul M, Bott U, et al. Less severe hypoglycaemia, better metabolic control, and improved quality of life in Type 1 diabetes mellitus with continuous subcutaneous insulin infusion (CSII) therapy; an observational study of 100 consecutive patients followed for a mean of 2 years. Diabet Med 2002;19(9):746-51 (Pubitemid 35013853
    • (2002) Diabetic Medicine , vol.19 , Issue.9 , pp. 746-751
    • Linkeschova, R.1    Raoul, M.2    Bott, U.3    Berger, M.4    Spraul, M.5
  • 99
    • 77954436411 scopus 로고    scopus 로고
    • Discontinuation of insulin pump treatment in children, adolescents, and young adults a multicenter analysis based on the dpn Database in germany and austria
    • Hofer SE, Heidtmann B, Raile K, et al. Discontinuation of insulin pump treatment in children, adolescents, and young adults. A multicenter analysis based on the DPN Database in Germany and Austria. Pediatr Diabetes 2010;11(2):116-21
    • (2010) Pediatr Diabetes , vol.11 , Issue.2 , pp. 116-121
    • Hofer, S.E.1    Heidtmann, B.2    Raile, K.3
  • 100
    • 80051606252 scopus 로고    scopus 로고
    • Satisfaction with continuous glucose monitoring in adults and youths with type 1 diabetes
    • Tansey M, Laffel L, Cheng J, et al. Satisfaction with continuous glucose monitoring in adults and youths with Type 1 diabetes. Diabet Med 2011;28(9):1118-22
    • (2011) Diabet Med , vol.28 , Issue.9 , pp. 1118-1122
    • Tansey, M.1    Laffel, L.2    Cheng, J.3
  • 101
    • 79951710868 scopus 로고    scopus 로고
    • Quality-of-life measures in children and adults with type 1 diabetes: Juvenile diabetes research foundation continuous glucose monitoring randomized trial
    • Beck RW, Lawrence JM, Laffel L, et al. Quality-of-life measures in children and adults with type 1 diabetes: Juvenile Diabetes Research Foundation Continuous Glucose Monitoring randomized trial. Diabetes Care 2010;33(10):2175-7
    • (2010) Diabetes Care , vol.33 , Issue.10 , pp. 2175-2177
    • Beck, R.W.1    Lawrence, J.M.2    Laffel, L.3
  • 102
    • 68149136644 scopus 로고    scopus 로고
    • The effect of continuous glucose monitoring in well-controlled type 1 diabetes
    • Beck RW, Hirsch IB, Laffel L, et al. The effect of continuous glucose monitoring in well-controlled type 1 diabetes. Diabetes Care 2009;32(8):1378-83
    • (2009) Diabetes Care , vol.32 , Issue.8 , pp. 1378-1383
    • Beck, R.W.1    Hirsch, I.B.2    Laffel, L.3
  • 103
    • 84870693262 scopus 로고    scopus 로고
    • Quality of life and technology: Impact on children and families with diabetes
    • Hirose M, Beverly EA, Weinger K. Quality of life and technology: Impact on children and families with diabetes. Curr Diab Rep 2012;12(6):711-20
    • (2012) Curr Diab Rep , vol.12 , Issue.6 , pp. 711-720
    • Hirose, M.1    Beverly, E.A.2    Weinger, K.3
  • 104
    • 84880413071 scopus 로고    scopus 로고
    • Treatment satisfaction in the sensor-Augmented pump therapy for a1c reduction 3 star 3) trial
    • Peyrot M, Rubin RR, Group SS. Treatment satisfaction in the sensor-Augmented pump therapy for A1C reduction 3 (STAR 3) trial. Diabet Med 2013;30(4):464-7
    • (2013) Diabet Med , vol.30 , Issue.4 , pp. 464-467
    • Peyrot, M.1    Rubin, R.R.2
  • 105
    • 84855840292 scopus 로고    scopus 로고
    • Health-related quality of life and treatment satisfaction in the sensor-Augmented pump therapy for a1c reduction 3 star 3) trial
    • Rubin RR, Peyrot M, Group SS. Health-related quality of life and treatment satisfaction in the Sensor-Augmented Pump Therapy for A1C Reduction 3 (STAR 3) trial. Diabetes Technol Ther 2012;14(2):143-51
    • (2012) Diabetes Technol Ther , vol.14 , Issue.2 , pp. 143-151
    • Rubin, R.R.1    Peyrot, M.2
  • 106
    • 84862109765 scopus 로고    scopus 로고
    • The accuracy benefit of multiple amperometric glucose sensors in people with type 1 diabetes
    • Castle JR, Pitts A, Hanavan K, et al. The accuracy benefit of multiple amperometric glucose sensors in people with type 1 diabetes. Diabetes Care 2012;35(4):706-10
    • (2012) Diabetes Care , vol.35 , Issue.4 , pp. 706-710
    • Castle, J.R.1    Pitts, A.2    Hanavan, K.3
  • 107
    • 0035514022 scopus 로고    scopus 로고
    • Limitations of conventional methods of self-monitoring of blood glucose lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes
    • Boland E, Monsod T, Delucia M, et al. Limitations of conventional methods of self-monitoring of blood glucose: Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes. Diabetes Care 2001;24(11):1858-62 (Pubitemid 33716491
    • (2001) Diabetes Care , vol.24 , Issue.11 , pp. 1858-1862
    • Boland, E.1    Monsod, T.2    Delucia, M.3    Brandt, C.A.4    Fernando, S.5    Tamborlane, W.V.6
  • 108
    • 38149091855 scopus 로고    scopus 로고
    • Effect of puberty on the pharmacodynamic and pharmacokinetic properties of insulin pump therapy in youth with type 1 diabetes
    • Swan KL, Weinzimer SA, Dziura JD, et al. Effect of puberty on the pharmacodynamic and pharmacokinetic properties of insulin pump therapy in youth with type 1 diabetes. Diabetes Care 2008;31(1):44-6
    • (2008) Diabetes Care , vol.31 , Issue.1 , pp. 44-46
    • Swan, K.L.1    Weinzimer, S.A.2    Dziura, J.D.3
  • 109
    • 84876797666 scopus 로고    scopus 로고
    • Acceleration of insulin pharmacodynamic profile by a novel insulin infusion site warming device
    • Cengiz E, Weinzimer SA, Sherr JL, et al. Acceleration of insulin pharmacodynamic profile by a novel insulin infusion site warming device. Pediatr Diabetes 2013;14(3):168-73
    • (2013) Pediatr Diabetes , vol.14 , Issue.3 , pp. 168-173
    • Cengiz, E.1    Weinzimer, S.A.2    Sherr, J.L.3
  • 110
    • 79956073035 scopus 로고    scopus 로고
    • Accelerated insulin pharmacokinetics and improved postprandial glycemic control in patients with type 1 diabetes after coadministration of prandial insulins with hyaluronidase
    • Hompesch M, Muchmore DB, Morrow L, et al. Accelerated insulin pharmacokinetics and improved postprandial glycemic control in patients with type 1 diabetes after coadministration of prandial insulins with hyaluronidase. Diabetes Care 2011;34(3):666-8
    • (2011) Diabetes Care , vol.34 , Issue.3 , pp. 666-668
    • Hompesch, M.1    Muchmore, D.B.2    Morrow, L.3
  • 111
    • 84866727216 scopus 로고    scopus 로고
    • Effect of pramlintide on prandial glycemic excursions during closed-loop control in adolescents and young adults with type 1 diabetes
    • Weinzimer SA, Sherr JL, Cengiz E, et al. Effect of pramlintide on prandial glycemic excursions during closed-loop control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012;35(10):1994-9
    • (2012) Diabetes Care , vol.35 , Issue.10 , pp. 1994-1999
    • Weinzimer, S.A.1    Sherr, J.L.2    Cengiz, E.3
  • 112
    • 84872181342 scopus 로고    scopus 로고
    • Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: A novel single-port technique for the treatment of type 1 diabetes patients
    • Regittnig W, Lindpointner S, Korsatko S, et al. Periodic extraction of interstitial fluid from the site of subcutaneous insulin infusion for the measurement of glucose: A novel single-port technique for the treatment of type 1 diabetes patients. Diabetes Technol Ther 2013;15(1):50-9
    • (2013) Diabetes Technol Ther , vol.15 , Issue.1 , pp. 50-59
    • Regittnig, W.1    Lindpointner, S.2    Korsatko, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.