메뉴 건너뛰기




Volumn 55, Issue 12, 2012, Pages 3155-3162

The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: A randomised controlled trial

Author keywords

Continuous glucose monitoring; Diabetes mellitus type 1; Glycaemic control; Insulin pump therapy; Randomised controlled trial; Sensor augmented insulin pump therapy

Indexed keywords

GLUCOSE; HEMOGLOBIN A1C; SHORT ACTING INSULIN;

EID: 84868213630     PISSN: 0012186X     EISSN: 14320428     Source Type: Journal    
DOI: 10.1007/s00125-012-2708-9     Document Type: Article
Times cited : (428)

References (19)
  • 1
    • 29144453326 scopus 로고    scopus 로고
    • Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
    • Nathan DM, Cleary PA, Backlund JY et al (2005) Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes. N Engl J Med 353:2643-2453
    • (2005) N Engl J Med , vol.353 , pp. 2643-2453
    • Nathan, D.M.1    Cleary, P.A.2    Backlund, J.Y.3
  • 2
    • 67749084303 scopus 로고    scopus 로고
    • Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration: The diabetes control and complications trial/epidemiology of diabetes interventions and complications and pittsburgh epidemiology of diabetes complications experience (1983-2005
    • Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Research Group
    • Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Research Group, Nathan DM, Zinman B et al (2000) Modern-day clinical course of type 1 diabetes mellitus after 30 years' duration: the diabetes control and complications trial/epidemiology of diabetes interventions and complications and Pittsburgh epidemiology of diabetes complications experience (1983-2005). Arch Intern Med 169:1307-1316
    • (2000) Arch Intern Med , vol.169 , pp. 1307-1316
    • Nathan, D.M.1    Zinman, B.2
  • 3
    • 78651338445 scopus 로고    scopus 로고
    • Standards of medical care in diabetes -2011
    • American Diabetes Association
    • American Diabetes Association (2011) Standards of medical care in diabetes -2011. Diabetes Care 34(Suppl 1):S11-S61
    • (2011) Diabetes Care , vol.34 , Issue.SUPPL. 1
  • 4
    • 77950902799 scopus 로고    scopus 로고
    • Continuous subcutaneous insulin infusion (csii) versus multiple insulin injections for type 1 diabetes mellitus
    • Art No doi:10.1002/14651858.CD005103.pub2
    • Misso ML, Egberts KJ, Page M, O'Connor D, Shaw J (2010) Continuous subcutaneous insulin infusion (CSII) versus multiple insulin injections for type 1 diabetes mellitus. Cochrane Database Syst Rev, Issue 1, Art. No.: doi:10.1002/14651858.CD005103.pub2
    • (2010) Cochrane Database Syst Rev , vol.1
    • Misso, M.L.1    Egberts, K.J.2    Page, M.3    O'Connor, D.4    Shaw, J.5
  • 5
    • 49649112407 scopus 로고    scopus 로고
    • Severe hypoglycaemia and glycaemic control in type 1 diabetes: Meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion
    • Pickup JC, Sutton AJ (2008) Severe hypoglycaemia and glycaemic control in type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion. Diabet Med 25:765-774
    • (2008) Diabet Med , vol.25 , pp. 765-774
    • Pickup, J.C.1    Sutton, A.J.2
  • 6
    • 33845483509 scopus 로고    scopus 로고
    • Improved glycemic control in poorly controlled patients with type 1 diabetes using realtime continuous glucose monitoring
    • Deiss D, Bolinder J, Riveline JP et al (2006) Improved glycemic control in poorly controlled patients with type 1 diabetes using realtime continuous glucose monitoring. Diabetes Care 29:2730-2732
    • (2006) Diabetes Care , vol.29 , pp. 2730-2732
    • Deiss, D.1    Bolinder, J.2    Riveline, J.P.3
  • 7
    • 54849147700 scopus 로고    scopus 로고
    • Continuous glucose monitoring and intensive treatment of type 1 diabetes
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group, Tamborlane WV, Beck RW et al (2008) Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 359:1464-1476
    • (2008) N Engl J Med , vol.359 , pp. 1464-1476
    • Tamborlane, W.V.1    Beck, R.W.2
  • 8
    • 67349125899 scopus 로고    scopus 로고
    • Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: A randomised controlled trial
    • O'ConnellMA, Donath S, O'Neal DN et al (2009) Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial. Diabetologia 52:1250-1257
    • (2009) Diabetologia , vol.52 , pp. 1250-1257
    • O'Connell, M.A.1    Donath, S.2    O'Neal, D.N.3
  • 9
    • 68149136644 scopus 로고    scopus 로고
    • The effect of continuous glucose monitoring in well-controlled type 1 diabetes
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    • Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) The effect of continuous glucose monitoring in well-controlled type 1 diabetes. Diabetes Care 32:1378-1383
    • (2009) Diabetes Care , vol.32 , pp. 1378-1383
  • 10
    • 79956192128 scopus 로고    scopus 로고
    • Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes
    • Battelino T, Phillip M, Bratina N et al (2011) Effect of continuous glucose monitoring on hypoglycemia in type 1 diabetes. Diabetes Care 34:795-800
    • (2011) Diabetes Care , vol.34 , pp. 795-800
    • Battelino, T.1    Phillip, M.2    Bratina, N.3
  • 11
    • 77954830051 scopus 로고    scopus 로고
    • Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    • Bergenstal RM, Tamborlane WV, Ahmann A et al (2010) Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 363:311-320
    • (2010) N Engl J Med , vol.363 , pp. 311-320
    • Bergenstal, R.M.1    Tamborlane, W.V.2    Ahmann, A.3
  • 12
    • 79960098673 scopus 로고    scopus 로고
    • Sensor augmented pump therapy lowers hba1c in suboptimally controlled type 1 diabetes: A randomized controlled trial
    • Hermanides J, Nørgaard K, Bruttomesso D et al (2011) Sensor augmented pump therapy lowers HbA1c in suboptimally controlled type 1 diabetes: a randomized controlled trial. Diabet Med 28:1158-1167
    • (2011) Diabet Med , vol.28 , pp. 1158-1167
    • Hermanides, J.1    Nørgaard, K.2    Bruttomesso, D.3
  • 13
    • 50049127632 scopus 로고    scopus 로고
    • Sensor-augmented insulin pump therapy: Results of the first randomized treat-to-target study
    • Hirsch IB, Abelseth J, Bode BW et al (2008) Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther 10:377-383
    • (2008) Diabetes Technol Ther , vol.10 , pp. 377-383
    • Hirsch, I.B.1    Abelseth, J.2    Bode, B.W.3
  • 14
    • 72249116711 scopus 로고    scopus 로고
    • Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: The realtrend study
    • Raccah D, Sulmont V, Reznik Y et al (2009) Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study. Diabetes Care 32:2245-2250
    • (2009) Diabetes Care , vol.32 , pp. 2245-2250
    • Raccah, D.1    Sulmont, V.2    Reznik, Y.3
  • 15
    • 78650604192 scopus 로고    scopus 로고
    • The switch study (sensing with insulin pump therapy to control hba1c): Design and methods of a randomized controlled crossover trial on sensor-augmented insulin pump efficacy in type 1 diabetes suboptimally controlled with pump therapy
    • Conget I, Battelino T, GimenezM, Gough H, Castaneda J, Bolinder J (2011) The SWITCH study (sensing with insulin pump therapy to control HbA1c): design and methods of a randomized controlled crossover trial on sensor-augmented insulin pump efficacy in type 1 diabetes suboptimally controlled with pump therapy. Diabetes Technol Ther 13:49-54
    • (2011) Diabetes Technol Ther , vol.13 , pp. 49-54
    • Conget, I.1    Battelino, T.2    GimenezM Gough, H.3    Castaneda, J.4    Bolinder, J.5
  • 16
    • 79960319709 scopus 로고    scopus 로고
    • Glycemic control in type 1 diabetes during real time continuous glucose monitoring comparing with self-monitoring of blood glucose: A meta-analysis of randomized controlled trials using individual patient data
    • Pickup JC, Freeman SC, Sutton AJ (2011)Glycemic control in type 1 diabetes during real time continuous glucose monitoring comparing with self-monitoring of blood glucose: a meta-analysis of randomized controlled trials using individual patient data. BMJ 343:d3805
    • (2011) BMJ , vol.343
    • Pickup, J.C.1    Freeman, S.C.2    Sutton, A.J.3
  • 17
    • 84862668643 scopus 로고    scopus 로고
    • Continuous glucose monitoring systems for type 1 diabetes mellitus
    • Art No CD008101. doi:10.1002/14651858.CD008101.pub2
    • Langendam M, Luijf YM, Hooft L, DeVries JH, Mudde AH, Scholten RJPM (2012) Continuous glucose monitoring systems for type 1 diabetes mellitus. Cochrane Database Syst Rev, Issue 1, Art. No.: CD008101. doi:10.1002/14651858. CD008101.pub2
    • (2012) Cochrane Database Syst Rev , vol.1
    • Langendam, M.1    Luijf, Y.M.2    Hooft, L.3    DeVries, J.H.4    Mudde, A.H.5    Rjpm, S.6
  • 18
    • 49249094455 scopus 로고    scopus 로고
    • Establishing glycaemic control with continuous subcutaneous insulin infusion in children and adolescents with type 1 diabetes: Experience of the pedpump study in 17 countries
    • Danne T, Battelino T, Jarosz-Chobot P et al (2008) Establishing glycaemic control with continuous subcutaneous insulin infusion in children and adolescents with type 1 diabetes: experience of the PedPump Study in 17 countries. Diabetologia 51:1594-1601
    • (2008) Diabetologia , vol.51 , pp. 1594-1601
    • Danne, T.1    Battelino, T.2    Jarosz-Chobot, P.3
  • 19
    • 84862113120 scopus 로고    scopus 로고
    • Assessment of patient-led or physician-driven continuous glucose monitoring in patients with poorly controlled type 1 diabetes using basal-bolus insulin regimens: A 1-year multicenter study
    • Riveline JP, Schaepelynck P, Chaillous L et al (2012) Assessment of patient-led or physician-driven continuous glucose monitoring in patients with poorly controlled type 1 diabetes using basal-bolus insulin regimens: a 1-year multicenter study. Diabetes Care 35:965-971
    • (2012) Diabetes Care , vol.35 , pp. 965-971
    • Riveline, J.P.1    Schaepelynck, P.2    Chaillous, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.