메뉴 건너뛰기




Volumn 35, Issue 11, 2012, Pages 2182-2187

The use of an automated, portable glucose control system for overnight glucose control in adolescents and young adults with type 1 diabetes

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; INSULIN; INSULIN ASPART; INSULIN LISPRO;

EID: 84868087308     PISSN: 01495992     EISSN: 19355548     Source Type: Journal    
DOI: 10.2337/dc12-0761     Document Type: Article
Times cited : (81)

References (28)
  • 1
    • 0031006603 scopus 로고    scopus 로고
    • Hypoglycemia in the Diabetes Control and Complications Trial
    • The Diabetes Control and Complications Trial Research Group
    • The Diabetes Control and Complications Trial Research Group. Hypoglycemia in the Diabetes Control and Complications Trial. Diabetes 1997;46:271-286
    • (1997) Diabetes , vol.46 , pp. 271-286
  • 2
    • 4644266916 scopus 로고    scopus 로고
    • The impact of a decade of changing treatment on rates of severe hypoglycemia in a population-based cohort of children with type 1 diabetes
    • DOI 10.2337/diacare.27.10.2293
    • Bulsara MK, Holman CD, Davis EA, Jones TW. The impact of a decade of changing treatment on rates of severe hypoglycemia in a population-based cohort of children with type 1 diabetes. Diabetes Care 2004;27:2293-2298 (Pubitemid 39281375)
    • (2004) Diabetes Care , vol.27 , Issue.10 , pp. 2293-2298
    • Bulsara, M.K.1    Holman, C.D.J.2    Davis, E.A.3    Jones, T.W.4
  • 3
    • 34548660790 scopus 로고    scopus 로고
    • Continuous glucose monitoring in children with type 1 diabetes
    • Diabetes Research in Children Network (DirecNet) Study Group
    • Diabetes Research in Children Network (DirecNet) Study Group, Buckingham B, Beck RW, Tamborlane WV, et al. Continuous glucose monitoring in children with type 1 diabetes. J Pediatr 2007;151:388-393, 393.e1-2.
    • (2007) J Pediatr , vol.151
    • Buckingham, B.1    Beck, R.W.2    Tamborlane, W.V.3
  • 4
    • 70349696377 scopus 로고    scopus 로고
    • Impaired awareness of hypoglycemia in a population-based sample of children and adolescents with type 1 diabetes
    • Ly TT, Gallego PH, Davis EA, Jones TW. Impaired awareness of hypoglycemia in a population-based sample of children and adolescents with type 1 diabetes. Diabetes Care 2009;32:1802-1806
    • (2009) Diabetes Care , vol.32 , pp. 1802-1806
    • Ly, T.T.1    Gallego, P.H.2    Davis, E.A.3    Jones, T.W.4
  • 5
    • 77954830051 scopus 로고    scopus 로고
    • Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
    • STAR 3 Study Group
    • Bergenstal RM, Tamborlane WV, Ahmann A, et al.; STAR 3 Study Group. Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes. N Engl J Med 2010;363:311-320
    • (2010) N Engl J Med , vol.363 , pp. 311-320
    • Bergenstal, R.M.1    Tamborlane, W.V.2    Ahmann, A.3
  • 6
    • 79960098673 scopus 로고    scopus 로고
    • Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial
    • Hermanides J, Nørgaard K, Bruttomesso D, et al. Sensor-augmented pump therapy lowers HbA(1c) in suboptimally controlled Type 1 diabetes; a randomized controlled trial. Diabet Med 2011;28:1158-1167
    • (2011) Diabet Med , vol.28 , pp. 1158-1167
    • Hermanides, J.1    Nørgaard, K.2    Bruttomesso, D.3
  • 7
    • 58849102225 scopus 로고    scopus 로고
    • 2008 Update from the Collaborative Islet Transplant Registry
    • Collaborative Islet Transplant Registry Investigators
    • Alejandro R, Barton FB, Hering BJ, Wease S; Collaborative Islet Transplant Registry Investigators. 2008 Update from the Collaborative Islet Transplant Registry. Transplantation 2008;86:1783-1788
    • (2008) Transplantation , vol.86 , pp. 1783-1788
    • Alejandro, R.1    Barton, F.B.2    Hering, B.J.3    Wease, S.4
  • 9
    • 14844351847 scopus 로고    scopus 로고
    • Accuracy of the modified continuous glucose monitoring system (CGMS) sensor in an outpatient setting: Results from a diabetes research in children network (DirecNet) study
    • DOI 10.1089/dia.2005.7.109
    • Tansey MJ, Beck RW, Buckingham BA, et al.; Diabetes Research in Children Network (DirecNet) Study Group. Accuracy of the modified Continuous Glucose Monitoring System (CGMS) sensor in an outpatient setting: results from a diabetes research in children network (DirecNet) study.Diabetes Technol Ther 2005;7:109-114 (Pubitemid 40354580)
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.1 , pp. 109-114
    • Tansey, M.J.1
  • 10
    • 33748412631 scopus 로고    scopus 로고
    • Evaluation of factors affecting CGMS calibration
    • Diabetes Research In Children Network (DirecNet) Study Group
    • Diabetes Research In Children Network (DirecNet) Study Group, Buckingham BA, Kollman C, Beck R, et al. Evaluation of factors affecting CGMS calibration. Diabetes Technol Ther 2006;8:318-325
    • (2006) Diabetes Technol Ther , vol.8 , pp. 318-325
    • Buckingham, B.A.1    Kollman, C.2    Beck, R.3
  • 11
    • 33845521334 scopus 로고    scopus 로고
    • Feasibility of automating insulin delivery for the treatment of type 1 diabetes
    • DOI 10.2337/db06-0419
    • Steil GM, Rebrin K, Darwin C, Hariri F, Saad MF. Feasibility of automating insulin delivery for the treatment of type 1 diabetes. Diabetes 2006;55:3344-3350 (Pubitemid 44923591)
    • (2006) Diabetes , vol.55 , Issue.12 , pp. 3344-3350
    • Steil, G.M.1    Rebrin, K.2    Darwin, C.3    Hariri, F.4    Saad, M.F.5
  • 12
    • 48649083317 scopus 로고    scopus 로고
    • Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas
    • Weinzimer SA, Steil GM, Swan KL, Dziura J, Kurtz N, Tamborlane WV. Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008;31:934-939
    • (2008) Diabetes Care , vol.31 , pp. 934-939
    • Weinzimer, S.A.1    Steil, G.M.2    Swan, K.L.3    Dziura, J.4    Kurtz, N.5    Tamborlane, W.V.6
  • 13
    • 77953007422 scopus 로고    scopus 로고
    • Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: The Virginia experience
    • Clarke WL, Anderson S, Breton M, Patek S, Kashmer L, Kovatchev B. Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: the Virginia experience. J Diabetes Sci Tech 2009;3:1031-1038
    • (2009) J Diabetes Sci Tech , vol.3 , pp. 1031-1038
    • Clarke, W.L.1    Anderson, S.2    Breton, M.3    Patek, S.4    Kashmer, L.5    Kovatchev, B.6
  • 14
    • 77249137912 scopus 로고    scopus 로고
    • Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: Preliminary studies in Padova and Montpellier
    • Bruttomesso D, Farret A, Costa S, et al. Closed-loop artificial pancreas using subcutaneous glucose sensing and insulin delivery and a model predictive control algorithm: preliminary studies in Padova and Montpellier. J Diabetes Sci Tech 2009;3:1014-1021
    • (2009) J Diabetes Sci Tech , vol.3 , pp. 1014-1021
    • Bruttomesso, D.1    Farret, A.2    Costa, S.3
  • 15
    • 77249157244 scopus 로고    scopus 로고
    • Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: A phase 2 randomised crossover trial
    • Hovorka R, Allen JM, Elleri D, et al.Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial. Lancet 2010;375:743-751
    • (2010) Lancet , vol.375 , pp. 743-751
    • Hovorka, R.1    Allen, J.M.2    Elleri, D.3
  • 16
    • 77954901769 scopus 로고    scopus 로고
    • MD-logic artificial pancreas system: A pilot study in adults with type 1 diabetes
    • Atlas E, Nimri R, Miller S, Grunberg EA, Phillip M. MD-logic artificial pancreas system: a pilot study in adults with type 1 diabetes. Diabetes Care 2010;33:1072-1076
    • (2010) Diabetes Care , vol.33 , pp. 1072-1076
    • Atlas, E.1    Nimri, R.2    Miller, S.3    Grunberg, E.A.4    Phillip, M.5
  • 17
    • 79954457764 scopus 로고    scopus 로고
    • Overnight closed-loop insulin delivery (arti ficial pancreas) in adults with type 1 diabetes: Crossover randomised controlled studies
    • Hovorka R, Kumareswaran K, Harris J, et al. Overnight closed-loop insulin delivery (arti ficial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies. BMJ 2011;342:d1855.
    • (2011) BMJ , vol.342
    • Hovorka, R.1    Kumareswaran, K.2    Harris, J.3
  • 18
    • 79953186640 scopus 로고    scopus 로고
    • Automated overnight closed-loop glucose control in young children with type 1 diabetes
    • Elleri D, Allen JM, Nodale M, et al. Automated overnight closed-loop glucose control in young children with type 1 diabetes. Diabetes Technol Ther 2011;13:419-424
    • (2011) Diabetes Technol Ther , vol.13 , pp. 419-424
    • Elleri, D.1    Allen, J.M.2    Nodale, M.3
  • 19
    • 79955670667 scopus 로고    scopus 로고
    • The effect of insulin feedback on closed loop glucose control
    • Steil GM, Palerm CC, Kurtz N, et al. The effect of insulin feedback on closed loop glucose control. J Clin Endocrinol Metab 2011;96:1402- 1408
    • (2011) J Clin Endocrinol Metab , vol.96 , pp. 1402-1408
    • Steil, G.M.1    Palerm, C.C.2    Kurtz, N.3
  • 20
    • 0023239175 scopus 로고
    • Insulin suppresses its own secretion in vivo
    • Argoud GM, Schade DS, Eaton RP. Insulin suppresses its own secretion in vivo. Diabetes 1987;36:959-962 (Pubitemid 17136810)
    • (1987) Diabetes , vol.36 , Issue.8 , pp. 959-962
    • Argoud, G.M.1    Schade, D.S.2    Eaton, R.P.3
  • 21
    • 84863298190 scopus 로고    scopus 로고
    • Accuracy of the Enlite 6-day glucose sensor with guardian and Veo calibration algorithms
    • Keenan DB, Mastrototaro JJ, Zisser H, et al. Accuracy of the Enlite 6-day glucose sensor with guardian and Veo calibration algorithms. Diabetes Technol Ther 2012;14:225-231
    • (2012) Diabetes Technol Ther , vol.14 , pp. 225-231
    • Keenan, D.B.1    Mastrototaro, J.J.2    Zisser, H.3
  • 22
    • 0031014593 scopus 로고    scopus 로고
    • Hypoglycemia: Incidence and clinical predictors in a large population- based sample of children and adolescents with IDDM
    • Davis EA, Keating B, Byrne GC, Russell M, Jones TW. Hypoglycemia: incidence and clinical predictors in a large population-based sample of children and adolescents with IDDM. Diabetes Care 1997;20:22-25 (Pubitemid 27020036)
    • (1997) Diabetes Care , vol.20 , Issue.1 , pp. 22-25
    • Davis, E.A.1    Keating, B.2    Byrne, G.C.3    Russell, M.4    Jones, T.W.5
  • 23
    • 84855858659 scopus 로고    scopus 로고
    • Hypoglycemia does not change the threshold for arousal from sleep in adolescents with type 1 diabetes
    • Ly TT, Jones TW, Griffiths A, et al. Hypoglycemia does not change the threshold for arousal from sleep in adolescents with type 1 diabetes. Diabetes Technol Ther 2012;14:101-104
    • (2012) Diabetes Technol Ther , vol.14 , pp. 101-104
    • Ly, T.T.1    Jones, T.W.2    Griffiths, A.3
  • 26
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
    • Garg S, Zisser H, Schwartz S, et al. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care 2006;29:44-50 (Pubitemid 44033429)
    • (2006) Diabetes Care , vol.29 , Issue.1 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 28
    • 77954671439 scopus 로고    scopus 로고
    • Accuracy of a new real-time continuous glucose monitoring algorithm
    • Keenan DB, Cartaya R, Mastrototaro JJ. Accuracy of a new real-time continuous glucose monitoring algorithm. J Diabetes Sci Tech 2010;4:111-118
    • (2010) J Diabetes Sci Tech , vol.4 , pp. 111-118
    • Keenan, D.B.1    Cartaya, R.2    Mastrototaro, J.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.