Volumn 7, Issue 5, 2005, Pages 675-680

Accuracy of newer-generation home blood glucose meters in a Diabetes Research in Children Network (DirecNet) inpatient exercise study

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE; HEXOKINASE;

EID: 27644544001     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2005.7.675     Document Type: Article
Times cited : (49)

References (13)
  • 1
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • The Diabetes Control and Complications Trial Research Group: The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993;329:977-986.
    • (1993) N Engl J Med , vol.329 , pp. 977-986
  • 4
    • 0023239559 scopus 로고
    • Consensus statement on self-monitoring of blood glucose
    • American Diabetes Association: Consensus statement on self-monitoring of blood glucose. Diabetes Care 1987;10:95-99.
    • (1987) Diabetes Care , vol.10 , pp. 95-99
  • 5
    • 0028158543 scopus 로고
    • Self-monitoring of blood glucose
    • American Diabetes Association: Self-monitoring of blood glucose. Diabetes Care 1994;17:81-86.
    • (1994) Diabetes Care , vol.17 , pp. 81-86
  • 6
    • 0347624613 scopus 로고    scopus 로고
    • A multicenter study of the accuracy of the OneTouch Ultra home glucose meter in children with type 1 diabetes
    • Diabetes Research in Children Network (DirecNet) Study Group: A multicenter study of the accuracy of the OneTouch Ultra home glucose meter in children with type 1 diabetes. Diabetes Technol Ther 2003;5:933-941.
    • (2003) Diabetes Technol Ther , vol.5 , pp. 933-941
  • 8
    • 0017332480 scopus 로고
    • Evaluation and comparison of 10 glucose methods and the reference method recommended in the proposed product class standard (1974)
    • Passey RB, Gillum RL, Fuller JB, Urry FM, Giles ML: Evaluation and comparison of 10 glucose methods and the reference method recommended in the proposed product class standard (1974). Clin Chem 1977;23:131-139.
    • (1977) Clin Chem , vol.23 , pp. 131-139
    • Passey, R.B.1    Gillum, R.L.2    Fuller, J.B.3    Urry, F.M.4    Giles, M.L.5
  • 9
    • 84961699889 scopus 로고    scopus 로고
    • In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus
    • Geneva: International Organisation for Standardization
    • International Organisation for Standardization: In Vitro Diagnostic Test Systems-Requirements for Blood-Glucose Monitoring Systems for Self-Testing in Managing Diabetes Mellitus. ISO 15197. Geneva: International Organisation for Standardization, 2003.
    • (2003) ISO 15197
  • 11
    • 0036092613 scopus 로고    scopus 로고
    • Instruments for self-monitoring of blood glucose: Comparisons of testing quality achieved by patients and a technician
    • Skeie S, Thue G, Nerhus K, Sandberg S: Instruments for self-monitoring of blood glucose: Comparisons of testing quality achieved by patients and a technician. Clin Chem 2002;48:994-1003.
    • (2002) Clin Chem , vol.48 , pp. 994-1003
    • Skeie, S.1    Thue, G.2    Nerhus, K.3    Sandberg, S.4
  • 12
    • 0036597372 scopus 로고    scopus 로고
    • Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites
    • Ellison JM, Stegmann JM, Coiner SL, Michael RH, Sharma MK, Ervin KR, Horwitz DL: Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites. Diabetes Care 2002;25:961-964.
    • (2002) Diabetes Care , vol.25 , pp. 961-964
    • Ellison, J.M.1    Stegmann, J.M.2    Coiner, S.L.3    Michael, R.H.4    Sharma, M.K.5    Ervin, K.R.6    Horwitz, D.L.7
  • 13
    • 0036593252 scopus 로고    scopus 로고
    • Glucose monitoring at the arm: Risky delays of hypoglycemia and hyperglycemia detection
    • Jungheim K, Koschinsky T: Glucose monitoring at the arm: Risky delays of hypoglycemia and hyperglycemia detection. Diabetes Care 2002;25:956-960.
    • (2002) Diabetes Care , vol.25 , pp. 956-960
    • Jungheim, K.1    Koschinsky, T.2