메뉴 건너뛰기




Volumn 37, Issue 5, 2014, Pages

Deviation analysis of atlantoaxial pedicle screws assisted by a drill template

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANALYTICAL ERROR; ARTICLE; BONE DRILL; CADAVER; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER MODEL; COMPUTER PROGRAM; COMPUTER SIMULATION; CONTROLLED STUDY; FEMALE; HUMAN; HUMAN TISSUE; IMAGE RECONSTRUCTION; MALE; MEDICAL DEVICE COMPLICATION; PEDICLE SCREW; PEDICLE SCREW DEVIATION; SPINE FUSION; SPINE STABILIZATION; SURGICAL ANATOMY; VALIDATION PROCESS;

EID: 84900524014     PISSN: 01477447     EISSN: 19382367     Source Type: Journal    
DOI: 10.3928/01477447-20140430-51     Document Type: Article
Times cited : (28)

References (30)
  • 1
    • 78549243017 scopus 로고    scopus 로고
    • Transarticular screw fixation for atlantoaxial instability: Modified Magerl's technique in 38 patients
    • Bahadur R, Goyal T, Dhatt SS, Tripathy SK. Transarticular screw fixation for atlantoaxial instability: modified Magerl's technique in 38 patients. J Orthop Surg Res. 2010; 5:87.
    • (2010) J Orthop Surg Res , vol.5 , pp. 87
    • Bahadur, R.1    Goyal, T.2    Dhatt, S.S.3    Tripathy, S.K.4
  • 2
    • 0037626143 scopus 로고    scopus 로고
    • Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass
    • DOI 10.1097/00007632-200305010-00010
    • Tan M, Wang H, Wang Y, et al. Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass. Spine. 2003; 28:888-895. (Pubitemid 36542756)
    • (2003) Spine , vol.28 , Issue.9 , pp. 888-895
    • Tan, M.1    Wang, H.2    Wang, Y.3    Zhang, G.4    Yi, P.5    Li, Z.6    Wei, H.7    Yang, F.8
  • 3
    • 1842686189 scopus 로고    scopus 로고
    • Posterior C2 fixation using bilateral, crossing C2 laminar screws: Case series and technical note
    • Wright NM. Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech. 2004; 17:158-162.
    • (2004) J Spinal Disord Tech , vol.17 , pp. 158-162
    • Wright, N.M.1
  • 4
    • 0036481526 scopus 로고    scopus 로고
    • C1-C2 pedicle screw fixation with rigid cantilever beam construct: Case report and technical note
    • DOI 10.1097/00006123-200202000-00039
    • Resnick DK, Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery. 2002; 50:426-428. (Pubitemid 41672607)
    • (2002) Neurosurgery , vol.50 , Issue.2 , pp. 426-428
    • Resnick, D.K.1    Benzel, E.C.2
  • 5
    • 33745792102 scopus 로고    scopus 로고
    • Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior trans-articular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
    • Lapsiwala SB, Anderson PA, Oza A, Resnick DK. Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior trans-articular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery. 2006; 58:516-521.
    • (2006) Neurosurgery , vol.58 , pp. 516-521
    • Lapsiwala, S.B.1    Anderson, P.A.2    Oza, A.3    Resnick, D.K.4
  • 6
    • 0037099510 scopus 로고    scopus 로고
    • Anatomic suitability of the C1-C2 complex for pedicle screw fixation
    • DOI 10.1097/00007632-200207150-00003
    • Resnick DK, Lapsiwala S, Trost GR. Anatomic suitability of the C1-C2 complex for pedicle screw fixation. Spine. 2002; 27:1494-1498. (Pubitemid 34787171)
    • (2002) Spine , vol.27 , Issue.14 , pp. 1494-1498
    • Resnick, D.K.1    Lapsiwala, S.2    Trost, G.R.3
  • 7
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickman CA, Sonntag VK. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg. 1996; 85:221-224. (Pubitemid 26260828)
    • (1996) Journal of Neurosurgery , vol.85 , Issue.2 , pp. 221-224
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.H.3
  • 8
    • 0023680091 scopus 로고
    • Three dimensional movements of the upper spine
    • Panjabi M, Dvorak J, Duranceau J, et al. Three dimensional movements of the upper spine. Spine. 1988; 13:726-730.
    • (1988) Spine , vol.13 , pp. 726-730
    • Panjabi, M.1    Dvorak, J.2    Duranceau, J.3
  • 9
    • 4444332803 scopus 로고    scopus 로고
    • Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine
    • DOI 10.1097/01.brs.0000137287.67388.0b
    • Kothe R, Rüther W, Schneider E, Linke B. Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine. 2004; 29:1869-1875. (Pubitemid 39181043)
    • (2004) Spine , vol.29 , Issue.17 , pp. 1869-1875
    • Kothe, R.1    Ruther, W.2    Schneider, E.3    Linke, B.4
  • 10
    • 84864757303 scopus 로고    scopus 로고
    • Routine insertion of the lateral mass screw via the posterior arch for C1 fixation: Feasibility and related complications
    • Yeom JS, Kafle D, Nguyen NQ, et al. Routine insertion of the lateral mass screw via the posterior arch for C1 fixation: feasibility and related complications. Spine J. 2012; 12:476-483.
    • (2012) Spine J , vol.12 , pp. 476-483
    • Yeom, J.S.1    Kafle, D.2    Nguyen, N.Q.3
  • 11
    • 75049084845 scopus 로고    scopus 로고
    • Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch
    • Gebauer M, Barvencik F, Briem D, et al. Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch. Eur Spine J. 2010; 19:85-90.
    • (2010) Eur Spine J , vol.19 , pp. 85-90
    • Gebauer, M.1    Barvencik, F.2    Briem, D.3
  • 12
    • 84866841526 scopus 로고    scopus 로고
    • Computer-assisted C1-C2 transarticular screw fixation "Magerl technique" for atlantoaxial instability
    • Uehara M, Takahashi J, Hirabayashi H, et al. Computer-assisted C1-C2 transarticular screw fixation "Magerl technique" for atlantoaxial instability. Asian Spine J. 2012; 6:168-177.
    • (2012) Asian Spine J , vol.6 , pp. 168-177
    • Uehara, M.1    Takahashi, J.2    Hirabayashi, H.3
  • 13
    • 70349665247 scopus 로고    scopus 로고
    • A novel computer-assisted drill guide template for placement of C2 laminar screws
    • Lu S, Xu YQ, Zhang YZ, Xie L, Guo H, Li DP. A novel computer-assisted drill guide template for placement of C2 laminar screws. Eur Spine J. 2009; 18:1379-1385.
    • (2009) Eur Spine J , vol.18 , pp. 1379-1385
    • Lu, S.1    Xu, Y.Q.2    Zhang, Y.Z.3    Xie, L.4    Guo, H.5    Li, D.P.6
  • 14
    • 29444440003 scopus 로고    scopus 로고
    • Biomodeling as an aid to spinal instrumentation
    • DOI 10.1097/01.brs.0000190886.56895.3d
    • D'Urso PS, Williamson OD, Thompson RG. Biomodeling as an aid to spinal instrumentation. Spine. 2005; 30:2841-2845. (Pubitemid 43011052)
    • (2005) Spine , vol.30 , Issue.24 , pp. 2841-2845
    • D'Urso, P.S.1    Williamson, O.D.2    Thompson, R.G.3
  • 15
    • 84883776643 scopus 로고    scopus 로고
    • An optimal design for patient-specific templates for pedicle spine screws placement
    • doi: 10.1002/rcs.1439
    • Ferrari V, Parchi P, Condino S, et al. An optimal design for patient-specific templates for pedicle spine screws placement. Int J Med Robot. 2013; 9(3):298-304. doi: 10.1002/rcs.1439.
    • (2013) Int J Med Robot , vol.9 , Issue.3 , pp. 298-304
    • Ferrari, V.1    Parchi, P.2    Condino, S.3
  • 16
    • 84868647226 scopus 로고    scopus 로고
    • Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide
    • Kawaguchi Y, Nakano M, Yasuda T, Seki S, Hori T, Kimura T. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide. Spine. 2012; 37:1983-1988.
    • (2012) Spine , vol.37 , pp. 1983-1988
    • Kawaguchi, Y.1    Nakano, M.2    Yasuda, T.3    Seki, S.4    Hori, T.5    Kimura, T.6
  • 17
    • 80051905427 scopus 로고    scopus 로고
    • Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement
    • Lu S, Xu YQ, Chen GP, et al. Efficacy and accuracy of a novel rapid prototyping drill template for cervical pedicle screw placement. Comput Aided Surg. 2011; 16:240-248.
    • (2011) Comput Aided Surg , vol.16 , pp. 240-248
    • Lu, S.1    Xu, Y.Q.2    Chen, G.P.3
  • 18
    • 84864353230 scopus 로고    scopus 로고
    • Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template
    • Lu S, Zhang YZ, Wang Z, et al. Accuracy and efficacy of thoracic pedicle screws in scoliosis with patient-specific drill template. Med Biol Eng Comput. 2012; 50:751-758.
    • (2012) Med Biol Eng Comput , vol.50 , pp. 751-758
    • Lu, S.1    Zhang, Y.Z.2    Wang, Z.3
  • 19
    • 0035875841 scopus 로고    scopus 로고
    • Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2
    • DOI 10.1097/00007632-200106150-00017
    • Goffin J, Van Brussel K, Martens K, Vander Sloten J, Van Audekercke R, Smet MH. Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2. Spine. 2001; 26:1343-1347. (Pubitemid 32552511)
    • (2001) Spine , vol.26 , Issue.12 , pp. 1343-1347
    • Goffin, J.1    Van Brussel, K.2    Martens, K.3    Vander, S.J.4    Van Audekercke, R.5    Smet, M.-H.6
  • 20
    • 43049106488 scopus 로고    scopus 로고
    • Free-hand pedicle screw placement during revision spinal surgery: Analysis of 552 screws
    • DOI 10.1097/BRS.0b013e31816f28a1, PII 0000763220080501000016
    • Kim YW, Lenke LG, Kim YJ, et al. Free-hand pedicle screw placement during revision spinal surgery: analysis of 552 screws. Spine. 2008; 33:1141-1148. (Pubitemid 351630226)
    • (2008) Spine , vol.33 , Issue.10 , pp. 1141-1148
    • Kim, Y.-W.1    Lenke, L.G.2    Kim, Y.J.3    Bridwell, K.H.4    Kim, Y.B.5    Watanabe, K.6    Watanabe, K.7
  • 21
    • 84862865689 scopus 로고    scopus 로고
    • Free-hand pedicle screws insertion technique in the treatment of 120 consecutive scoliosis cases operated without use of intraoperative neurophysiological monitoring
    • Crostelli M, Mazza O, Mariani M. Free-hand pedicle screws insertion technique in the treatment of 120 consecutive scoliosis cases operated without use of intraoperative neurophysiological monitoring. Eur Spine J. 2012; 21(suppl 1):43-49.
    • (2012) Eur Spine J , vol.21 , Issue.SUPPL. 1 , pp. 43-49
    • Crostelli, M.1    Mazza, O.2    Mariani, M.3
  • 22
    • 67749110199 scopus 로고    scopus 로고
    • An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine
    • Su BW, Kim PD, Cha TD, et al. An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine. Spine. 2009; 34:1355-1362.
    • (2009) Spine , vol.34 , pp. 1355-1362
    • Su, B.W.1    Kim, P.D.2    Cha, T.D.3
  • 23
    • 78650923994 scopus 로고    scopus 로고
    • Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: Analysis of 6816 consecutive screws
    • Parker SL, McGirt MJ, Farber SH, et al. Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery. 2011; 68:170-178.
    • (2011) Neurosurgery , vol.68 , pp. 170-178
    • Parker, S.L.1    McGirt, M.J.2    Farber, S.H.3
  • 24
    • 4344632292 scopus 로고    scopus 로고
    • Vertebral artery in relationship to C1-C2 vertebrae: An anatomical study
    • Cacciola F, Phalke U, Goel A. Vertebral artery in relationship to C1-C2 vertebrae: an anatomical study. Neurol India. 2004; 52:178-184. (Pubitemid 39136945)
    • (2004) Neurology India , vol.52 , Issue.2 , pp. 178-184
    • Cacciola, F.1    Phalke, U.2    Goel, A.3
  • 25
    • 84870189587 scopus 로고    scopus 로고
    • Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: Perioperative results of a prospective, comparative, multicenter study
    • Yang BP, Wahl MM, Idler CS. Percutaneous lumbar pedicle screw placement aided by computer-assisted fluoroscopy-based navigation: perioperative results of a prospective, comparative, multicenter study. Spine. 2012; 37:2055-2060.
    • (2012) Spine , vol.37 , pp. 2055-2060
    • Yang, B.P.1    Wahl, M.M.2    Idler, C.S.3
  • 26
    • 84883004888 scopus 로고    scopus 로고
    • Robotic-assisted pedicle screw placement: Lessons learned from the first 102 patients
    • Hu X, Ohnmeiss DD, Lieberman IH. Robotic-assisted pedicle screw placement: lessons learned from the first 102 patients. Eur Spine J. 2013; 22(3):661-666.
    • (2013) Eur Spine J , vol.22 , Issue.3 , pp. 661-666
    • Hu, X.1    Ohnmeiss, D.D.2    Lieberman, I.H.3
  • 27
    • 84857794789 scopus 로고    scopus 로고
    • Safety of cervical pedicle screw insertion in children: A clinicoradiological evaluation of computer-assisted insertion of 51 cervical pedicle screws including 28 subaxial pedicle screws in 16 children
    • Rajasekaran S, Kanna P, Shetty AP. Safety of cervical pedicle screw insertion in children: a clinicoradiological evaluation of computer-assisted insertion of 51 cervical pedicle screws including 28 subaxial pedicle screws in 16 children. Spine. 2012; 37:E216-E223.
    • (2012) Spine , vol.37
    • Rajasekaran, S.1    Kanna, P.2    Shetty, A.P.3
  • 28
    • 78149332417 scopus 로고    scopus 로고
    • Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: A retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement
    • Ishikawa Y, Kanemura T, Yoshida G, Ito Z, Muramoto A, Ohno S. Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement. J Neurosurg Spine. 2010; 13:606-611.
    • (2010) J Neurosurg Spine , vol.13 , pp. 606-611
    • Ishikawa, Y.1    Kanemura, T.2    Yoshida, G.3    Ito, Z.4    Muramoto, A.5    Ohno, S.6
  • 29
    • 0036015571 scopus 로고    scopus 로고
    • Image-based planning and validation of C1-C2 transarticular screw fixation using personalized drill guides
    • DOI 10.1002/igs.10027
    • Van Cleynenbreugel J, Schutyser F, Goffin J, Van Brussel K, Suetens P. Image-based planning and validation of C1-C2 transarticular screw fixation using personalized drill guides. Comput Aided Surg. 2002; 7:41-48. (Pubitemid 34601714)
    • (2002) Computer Aided Surgery , vol.7 , Issue.1 , pp. 41-48
    • Van Cleynenbreugel, J.1    Schutyser, F.2    Goffin, J.3    Van Brussel, K.4    Suetens, P.5
  • 30
    • 84857634695 scopus 로고    scopus 로고
    • A novel computer-assisted drill guide template for thoracic pedicle screw placement: A cadaveric study
    • Ma T, Xu YQ, Cheng YB, et al. A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study. Arch Orthop Trauma Surg. 2012; 132:65-72.
    • (2012) Arch Orthop Trauma Surg , vol.132 , pp. 65-72
    • Ma, T.1    Xu, Y.Q.2    Cheng, Y.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.