-
1
-
-
17644379062
-
Personalised image-based templates for intra-operative guidance
-
DOI 10.1243/095441105X9273
-
E Berry M Cuppone S Porada PA Millner A Rao N Chiverton BB Seedhom 2005 Personalised image-based templates for intra-operative guidance Proc Inst Mech Eng [H] 219 111 118 10.1243/095441105X9273 1:STN:280:DC%2BD2M7os1antA%3D%3D (Pubitemid 40555652)
-
(2005)
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.219
, Issue.2
, pp. 111-118
-
-
Berry, E.1
Cuppone, M.2
Porada, S.3
Millner, P.A.4
Rao, A.5
Chiverton, N.6
Seedhom, B.B.7
-
2
-
-
0017871668
-
Atlanto-axial arthrodesis by the wedge compression method
-
348703 1:STN:280:DyaE1c7ntFGqug%3D%3D
-
AL Brooks EB Jenkins 1978 Atlanto-axial arthrodesis by the wedge compression method J Bone Joint Surg Am 60 279 284 348703 1:STN:280: DyaE1c7ntFGqug%3D%3D
-
(1978)
J Bone Joint Surg Am
, vol.60
, pp. 279-284
-
-
Brooks, A.L.1
Jenkins, E.B.2
-
3
-
-
0030017856
-
Arteriovenous fistula as a complication of C1-2 transarticular screw fixation: Case report and review of the literature
-
8755766 10.3171/jns.1996.85.2.0340 1:STN:280:DyaK28zgt1ejsA%3D%3D
-
D Coric CL Branch Jr JA Wilson JC Robinson 1996 Arteriovenous fistula as a complication of C1-2 transarticular screw fixation: case report and review of the literature J Neurosurg 85 340 343 8755766 10.3171/jns.1996.85.2.0340 1:STN:280:DyaK28zgt1ejsA%3D%3D
-
(1996)
J Neurosurg
, vol.85
, pp. 340-343
-
-
Coric, D.1
Branch Jr, C.L.2
Wilson, J.A.3
Robinson, J.C.4
-
4
-
-
0026092302
-
The interspinous method of posterior atlantoaxial arthrodesis
-
1988587 10.3171/jns.1991.74.2.0190 1:STN:280:DyaK3M7gvVGhsw%3D%3D
-
CA Dickman VK Sonntag SM Papadopoulos MN Hadley 1991 The interspinous method of posterior atlantoaxial arthrodesis J Neurosurg 74 190 198 1988587 10.3171/jns.1991.74.2.0190 1:STN:280:DyaK3M7gvVGhsw%3D%3D
-
(1991)
J Neurosurg
, vol.74
, pp. 190-198
-
-
Dickman, C.A.1
Sonntag, V.K.2
Papadopoulos, S.M.3
Hadley, M.N.4
-
5
-
-
0029869526
-
Anatomic consideration of C2 pedicle screw placement
-
DOI 10.1097/00007632-199603150-00005
-
N Ebraheim JR Rollins Jr R Xu WT Jackson 1996 Anatomic consideration of C2 pedicle screw placement Spine 21 691 695 10.1097/00007632-199603150-00005 8882690 10.1097/00007632-199603150-00005 1:STN:280:DyaK2s%2FjslSnsQ%3D%3D (Pubitemid 26088019)
-
(1996)
Spine
, vol.21
, Issue.6
, pp. 691-695
-
-
Ebraheim, N.1
Rollins Jr., J.R.2
Xu, R.3
Jackson, W.T.4
-
6
-
-
0035875841
-
Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-C2
-
DOI 10.1097/00007632-200106150-00017
-
J Goffin K Van Brussel K Martens J Vander Sloten R Van Audekercke MH Smet 2001 Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1-2 Spine 26 1343 1347 10.1097/00007632- 200106150-00017 11426150 10.1097/00007632-200106150-00017 1:STN:280: DC%2BD3MzmsVOlsA%3D%3D (Pubitemid 32552511)
-
(2001)
Spine
, vol.26
, Issue.12
, pp. 1343-1347
-
-
Goffin, J.1
Van Brussel, K.2
Martens, K.3
Vander Sloten, J.4
Van Audekercke, R.5
Smet, M.-H.6
-
7
-
-
22144451090
-
Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation
-
DOI 10.1097/01.brs.0000167827.84020.49
-
J Gorek E Acaroglu S Berven A Yousef CM Puttlitz 2005 Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation Spine 30 1513 1518 10.1097/01.brs.0000167827.84020.49 15990665 10.1097/01.brs.0000167827.84020.49 (Pubitemid 40979742)
-
(2005)
Spine
, vol.30
, Issue.13
, pp. 1513-1518
-
-
Gorek, J.1
Acaroglu, E.2
Berven, S.3
Yousef, A.4
Puttlitz, C.M.5
-
8
-
-
0025952072
-
Atlanto-axial fusion with transarticular screw fixation
-
1955447 1:STN:280:DyaK38%2FmsVKhtw%3D%3D
-
D Grob B Jeanneret M Aebi TM Markwalder 1991 Atlanto-axial fusion with transarticular screw fixation J Bone Joint Surg Br 73 972 976 1955447 1:STN:280:DyaK38%2FmsVKhtw%3D%3D
-
(1991)
J Bone Joint Surg Br
, vol.73
, pp. 972-976
-
-
Grob, D.1
Jeanneret, B.2
Aebi, M.3
Markwalder, T.M.4
-
9
-
-
21244433504
-
Intraoperative Iso-C C-arm navigation in cervical spinal surgery: Review of the first 52 cases
-
10.1097/01.brs.0000147742.20637.49 15599290 10.1097/01.brs.0000147742. 20637.49
-
JS Hott SM Papadopoulos N Theodore CA Dickman VK Sonntag 2004 Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases Spine 29 2856 2860 10.1097/01.brs.0000147742.20637.49 15599290 10.1097/01.brs.0000147742.20637.49
-
(2004)
Spine
, vol.29
, pp. 2856-2860
-
-
Hott, J.S.1
Papadopoulos, S.M.2
Theodore, N.3
Dickman, C.A.4
Sonntag, V.K.5
-
10
-
-
0037335825
-
Anatomic study of the axis for surgical planning of transarticular screw fixation
-
10.1097/00003086-200303000-00020 12616054 10.1097/00003086-200303000- 00020
-
T Igarashi S Kikuchi K Sato S Kayama K Otani 2003 Anatomic study of the axis for surgical planning of transarticular screw fixation Clin Orthop Relat Res 408 162 166 10.1097/00003086-200303000-00020 12616054 10.1097/00003086- 200303000-00020
-
(2003)
Clin Orthop Relat Res
, vol.408
, pp. 162-166
-
-
Igarashi, T.1
Kikuchi, S.2
Sato, K.3
Kayama, S.4
Otani, K.5
-
11
-
-
0026618885
-
Primary posterior fusion C1-2 in odontoid fractures: Indications, technique, and results of transarticular screw fixation technique
-
10.1097/00002517-199212000-00012 1490045 10.1097/00002517-199212000-00012 1:STN:280:DyaK3s7ksVyntg%3D%3D
-
B Jeanneret F Magerl 1992 Primary posterior fusion C1-2 in odontoid fractures: indications, technique, and results of transarticular screw fixation technique J Spinal Disord 5 464 475 10.1097/00002517-199212000-00012 1490045 10.1097/00002517-199212000-00012 1:STN:280:DyaK3s7ksVyntg%3D%3D
-
(1992)
J Spinal Disord
, vol.5
, pp. 464-475
-
-
Jeanneret, B.1
Magerl, F.2
-
12
-
-
0034466242
-
Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
-
DOI 10.1097/00002517-200006000-00004
-
M Kamimura S Ebara H Itoh Y Tateiwa T Kinoshita K Takaoka 2000 Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance J Spinal Disord 13 218 224 10.1097/00002517- 200006000-00004 10872759 10.1097/00002517-200006000-00004 1:STN:280: DC%2BD3M%2FgvFKqtA%3D%3D (Pubitemid 32201546)
-
(2000)
Journal of Spinal Disorders
, vol.13
, Issue.3
, pp. 218-224
-
-
Kamimura, M.1
Ebara, S.2
Itoh, H.3
Tateiwa, Y.4
Kinoshita, T.5
Takaoka, K.6
-
13
-
-
18044401973
-
Computer navigation of parapedicular screw fixation in the thoracic spine: A cadaver study
-
10.1097/00007632-200111010-00019 11679834 10.1097/00007632-200111010- 00019 1:STN:280:DC%2BD3Mrnt1aktg%3D%3D
-
R Kothe J Matthias Strauss G Deuretzbacher T Hemmi M Lorenzen L Wiesner 2001 Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study Spine 26 E496 E501 10.1097/00007632-200111010-00019 11679834 10.1097/00007632-200111010-00019 1:STN:280:DC%2BD3Mrnt1aktg%3D%3D
-
(2001)
Spine
, vol.26
-
-
Kothe, R.1
Matthias Strauss, J.2
Deuretzbacher, G.3
Hemmi, T.4
Lorenzen, M.5
Wiesner, L.6
-
14
-
-
33745792102
-
Biomechanical comparison of four C1 to C2 rigid fixative techniques: Anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws
-
16528192
-
SB Lapsiwala PA Anderson A Oza DK Resnick 2006 Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws Neurosurgery 58 516 521 16528192
-
(2006)
Neurosurgery
, vol.58
, pp. 516-521
-
-
Lapsiwala, S.B.1
Anderson, P.A.2
Oza, A.3
Resnick, D.K.4
-
15
-
-
37349080177
-
Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: A reliability study
-
DOI 10.1097/BRS.0b013e31815cdab9, PII 0000763220071215000017
-
RA Lehman Jr RC Sasso MD Helgeson AE Dmitriev NW Gill MR Rosner KD Riew 2007 Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: a reliability study Spine 32 3036 3040 10.1097/BRS.0b013e31815cdab9 18091498 10.1097/BRS.0b013e31815cdab9 (Pubitemid 350307288)
-
(2007)
Spine
, vol.32
, Issue.26
, pp. 3036-3040
-
-
Lehman Jr., R.A.1
Sasso, R.C.2
Helgeson, M.D.3
Dmitriev, A.E.4
Gill, N.W.5
Rosner, M.R.6
Riew, K.D.7
-
16
-
-
33644884982
-
Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws: Technical note
-
16509484
-
JR Leonard NM Wright 2006 Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws: technical note J Neurosurg 104 59 63 16509484
-
(2006)
J Neurosurg
, vol.104
, pp. 59-63
-
-
Leonard, J.R.1
Wright, N.M.2
-
17
-
-
0242487967
-
Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine
-
DOI 10.1007/s00586-003-0549-4
-
JM Mac-Thiong H Labelle M Rooze V Feipel CE Aubin 2003 Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine Eur Spine J 12 542 547 10.1007/s00586-003-0549-4 12783286 10.1007/s00586-003-0549-4 (Pubitemid 37409957)
-
(2003)
European Spine Journal
, vol.12
, Issue.5
, pp. 542-547
-
-
Mac-Thiong, J.-M.1
Labelle, H.2
Rooze, M.3
Feipel, V.4
Aubin, C.-E.5
-
18
-
-
0030973318
-
Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
-
AA Madawi AT Casey GA Solanki G Tuite R Veres HA Crockard 1997 Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique J Neurosurg 86 961 968 9171174 10.3171/jns.1997.86.6.0961 1:STN:280:DyaK2szhsFSjsg%3D%3D (Pubitemid 27230138)
-
(1997)
Journal of Neurosurgery
, vol.86
, Issue.6
, pp. 961-968
-
-
Madawi, A.A.1
Casey, A.T.H.2
Solanki, G.A.3
Tuite, G.4
Veres, R.5
Crockard, H.A.6
-
19
-
-
0034659356
-
Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws
-
DOI 10.1097/00007632-200006150-00014
-
IM Mandel BJ Kambach CA Petersilge B Johnstone JU Yoo 2000 Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws Spine 25 1542 1547 10.1097/00007632-200006150-00014 10851104 10.1097/00007632-200006150-00014 1:STN:280:DC%2BD3czovFKgtQ%3D%3D (Pubitemid 30418469)
-
(2000)
Spine
, vol.25
, Issue.12
, pp. 1542-1547
-
-
Mandel, I.M.1
Kambach, B.J.2
Petersilge, C.A.3
Johnstone, B.4
Yoo, J.U.5
-
20
-
-
0027164898
-
Posterior atlantoaxial facet screw fixation
-
8331406 10.3171/jns.1993.79.2.0234 1:STN:280:DyaK3szit1OrsQ%3D%3D
-
P Marcotte CA Dickman VK Sonntag DG Karahalios J Drabier 1993 Posterior atlantoaxial facet screw fixation J Neurosurg 79 234 237 8331406 10.3171/jns.1993.79.2.0234 1:STN:280:DyaK3szit1OrsQ%3D%3D
-
(1993)
J Neurosurg
, vol.79
, pp. 234-237
-
-
Marcotte, P.1
Dickman, C.A.2
Sonntag, V.K.3
Karahalios, D.G.4
Drabier, J.5
-
21
-
-
42149164337
-
Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance
-
10.1007/s00586-007-0557-x 18034268 10.1007/s00586-007-0557-x
-
EW Nottmeier AB Foy 2008 Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance Eur Spine J 17 610 615 10.1007/s00586-007-0557-x 18034268 10.1007/s00586-007-0557-x
-
(2008)
Eur Spine J
, vol.17
, pp. 610-615
-
-
Nottmeier, E.W.1
Foy, A.B.2
-
22
-
-
35648948435
-
Rapid prototype patient-specific drill template for cervical pedicle screw placement
-
DOI 10.1080/10929080701662826, PII 783323830
-
BD Owen GE Christensen JM Reinhardt TC Ryken 2007 Rapid prototype patient-specific drill template for cervical pedicle screw placement Comput Aided Surg 12 303 308 10.1080/10929080701662826 17957538 10.1080/ 10929080701662826 (Pubitemid 350034902)
-
(2007)
Computer Aided Surgery
, vol.12
, Issue.5
, pp. 303-308
-
-
Owen, B.D.1
Christensen, G.E.2
Reinhardt, J.M.3
Ryken, T.C.4
-
23
-
-
0031665319
-
Computer assisted orthopaedic surgery with image based individual templates
-
10.1097/00003086-199809000-00005 9755761 10.1097/00003086-199809000-00005
-
K Radermacher F Portheine M Anton A Zimolong G Kaspers G Rau HW Staudte 1998 Computer assisted orthopaedic surgery with image based individual templates Clin Orthop Relat Res 354 28 38 10.1097/00003086-199809000-00005 9755761 10.1097/00003086-199809000-00005
-
(1998)
Clin Orthop Relat Res
, vol.354
, pp. 28-38
-
-
Radermacher, K.1
Portheine, F.2
Anton, M.3
Zimolong, A.4
Kaspers, G.5
Rau, G.6
Staudte, H.W.7
-
24
-
-
0027174272
-
Atlanto-axial stabilization with posterior transarticular screw fixation: Technical description and report of 22 cases
-
10.1097/00006123-199306000-00011 8327097 10.1097/00006123-199306000-00011 1:STN:280:DyaK3szhslWntQ%3D%3D
-
CB Stillerman JA Wilson 1993 Atlanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases Neurosurgery 32 948 955 10.1097/00006123-199306000-00011 8327097 10.1097/00006123-199306000-00011 1:STN:280:DyaK3szhslWntQ%3D%3D
-
(1993)
Neurosurgery
, vol.32
, pp. 948-955
-
-
Stillerman, C.B.1
Wilson, J.A.2
-
25
-
-
32944477651
-
Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques
-
DOI 10.1097/01.bsd.0000168511.67189.64, PII 0002472020050800000013
-
AT Villavicencio S Burneikiene KR Bulsara JJ Thramann 2005 Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques J Spinal Disord Tech 18 369 375 10.1097/01.bsd.0000168511.67189.64 16021020 10.1097/01.bsd.0000168511.67189.64 (Pubitemid 44378156)
-
(2005)
Journal of Spinal Disorders and Techniques
, vol.18
, Issue.4
, pp. 369-375
-
-
Villavicencio, A.T.1
Burneikiene, S.2
Bulsara, K.R.3
Thramann, J.J.4
-
26
-
-
33745784887
-
C2 crossing laminar screws: Cadaveric morphometric analysis
-
DOI 10.1227/01.NEU.0000219900.24467.32, PII 0000612320060700100013
-
MY Wang 2006 C2 crossing laminar screws: cadaveric morphometric analysis Neurosurgery 59 84 88 10.1227/01.NEU.0000219900.24467.32 10.1227/01.NEU. 0000219900.24467.32 (Pubitemid 44024309)
-
(2006)
Neurosurgery
, vol.59
-
-
Wang, M.Y.1
-
27
-
-
1842686189
-
Posterior C2 fixation using bilateral, crossing C2 laminar screws: Case series and technical note
-
15260101
-
NM Wright 2004 Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note J Spinal Disord Tech 17 158 162 15260101
-
(2004)
J Spinal Disord Tech
, vol.17
, pp. 158-162
-
-
Wright, N.M.1
-
28
-
-
32944464250
-
Translaminar rigid screw fixation of the axis: Technical note
-
16302639 10.3171/spi.2005.3.5.0409
-
NM Wright 2005 Translaminar rigid screw fixation of the axis: technical note J Neurosurg Spine 3 409 414 16302639 10.3171/spi.2005.3.5.0409
-
(2005)
J Neurosurg Spine
, vol.3
, pp. 409-414
-
-
Wright, N.M.1
-
29
-
-
0031896021
-
Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves: American Association of Neurological Surgeons/Congress of Neurological Surgeons
-
9525707 10.3171/jns.1998.88.4.0634 1:STN:280:DyaK1c7osVKhsg%3D%3D
-
NM Wright C Lauryssen 1998 Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves: American Association of Neurological Surgeons/Congress of Neurological Surgeons J Neurosurg 88 634 640 9525707 10.3171/jns.1998.88.4.0634 1:STN:280:DyaK1c7osVKhsg%3D%3D
-
(1998)
J Neurosurg
, vol.88
, pp. 634-640
-
-
Wright, N.M.1
Lauryssen, C.2
|