메뉴 건너뛰기




Volumn 13, Issue 5, 2010, Pages 606-611

Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: A retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement - Clinical article

Author keywords

Cervical pedicle screw; Fluoroscopy; Three dimensional navigation

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; CERVICAL PEDICLE SCREW; CERVICAL SPINE; CHILD; CLINICAL EVALUATION; CLINICAL STUDY; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; FLUOROSCOPY; HUMAN; MAJOR CLINICAL STUDY; MALE; PEDICLE SCREW; PREVALENCE; RETROSPECTIVE STUDY; SCHOOL CHILD; SPINE STABILIZATION; THREE DIMENSIONAL IMAGING;

EID: 78149332417     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2010.5.SPINE09993     Document Type: Article
Times cited : (109)

References (28)
  • 1
    • 0028012268 scopus 로고
    • Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report
    • Abumi K, Itoh H, Taneichi H, Kaneda K: Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7:19-28, 1994
    • (1994) J Spinal Disord , vol.7 , pp. 19-28
    • Abumi, K.1    Itoh, H.2    Taneichi, H.3    Kaneda, K.4
  • 2
    • 0031427940 scopus 로고    scopus 로고
    • Pedicle screw fixation for nontraumatic lesions of the cervical spine
    • Abumi K, Kaneda K: Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 22:1853-1863, 1997
    • (1997) Spine , vol.22 , pp. 1853-1863
    • Abumi, K.1    Kaneda, K.2
  • 3
    • 0034655412 scopus 로고    scopus 로고
    • Complications of pedicle screw fixation in reconstructive surgery of the cervical spine
    • Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K: Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine 25:962-969, 2000
    • (2000) Spine , vol.25 , pp. 962-969
    • Abumi, K.1    Shono, Y.2    Ito, M.3    Taneichi, H.4    Kotani, Y.5    Kaneda, K.6
  • 4
    • 65849124230 scopus 로고    scopus 로고
    • Indications for cervical pedicle screw instrumentation in nontraumatic lesions
    • Hasegawa K, Hirano T, Shimoda H, Homma T, Morita O: Indications for cervical pedicle screw instrumentation in nontraumatic lesions. Spine 33:2284-2289, 2008
    • (2008) Spine , vol.33 , pp. 2284-2289
    • Hasegawa, K.1    Hirano, T.2    Shimoda, H.3    Homma, T.4    Morita, O.5
  • 5
    • 0042568676 scopus 로고    scopus 로고
    • Intraoperative spinal navigation
    • Holly LT, Foley KT: Intraoperative spinal navigation. Spine 28 (15 Suppl):S54-S61, 2003
    • (2003) Spine , vol.28 , Issue.15 SUPPL.
    • Holly, L.T.1    Foley, K.T.2
  • 7
    • 33947153987 scopus 로고    scopus 로고
    • Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients
    • Ito H, Neo M, Yoshida M, Fujibayashi S, Yoshitomi H, Nakamura T: Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. Rheumatol Int 27:567-574, 2007
    • (2007) Rheumatol Int , vol.27 , pp. 567-574
    • Ito, H.1    Neo, M.2    Yoshida, M.3    Fujibayashi, S.4    Yoshitomi, H.5    Nakamura, T.6
  • 8
    • 58149168458 scopus 로고    scopus 로고
    • Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. Clinical article
    • Ito Y, Sugimoto Y, Tomioka M, Hasegawa Y, Nakago K, Yagata Y: Clinical accuracy of 3D fluoroscopy-assisted cervical pedicle screw insertion. Clinical article. J Neurosurg Spine 9:450-453, 2008
    • (2008) J Neurosurg Spine , vol.9 , pp. 450-453
    • Ito, Y.1    Sugimoto, Y.2    Tomioka, M.3    Hasegawa, Y.4    Nakago, K.5    Yagata, Y.6
  • 9
    • 0031010622 scopus 로고    scopus 로고
    • Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison
    • Jones EL, Heller JG, Silcox DH, Hutton WC: Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine 22:977-982, 1997
    • (1997) Spine , vol.22 , pp. 977-982
    • Jones, E.L.1    Heller, J.G.2    Silcox, D.H.3    Hutton, W.C.4
  • 10
    • 0034466242 scopus 로고    scopus 로고
    • Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
    • Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K: Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218-224, 2000
    • (2000) J Spinal Disord , vol.13 , pp. 218-224
    • Kamimura, M.1    Ebara, S.2    Itoh, H.3    Tateiwa, Y.4    Kinoshita, T.5    Takaoka, K.6
  • 12
    • 0035890086 scopus 로고    scopus 로고
    • Accuracy of cervical pedicle screw placement using the funnel technique
    • Karaikovic EE, Yingsakmongkol W, Gaines RW Jr: Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26:2456-2462, 2001
    • (2001) Spine , vol.26 , pp. 2456-2462
    • Karaikovic, E.E.1    Yingsakmongkol, W.2    Gaines Jr., R.W.3
  • 13
    • 0142120120 scopus 로고    scopus 로고
    • Improved accuracy of computer-assisted cervical pedicle screw insertion
    • Kotani Y, Abumi K, Ito M, Minami A: Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg 99 (3 Suppl):257-263, 2003
    • (2003) J Neurosurg , vol.99 , Issue.3 SUPPL. , pp. 257-263
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Minami, A.4
  • 14
    • 4444332803 scopus 로고    scopus 로고
    • Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine
    • Kothe R, Rüther W, Schneider E, Linke B: Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine. Spine 29:1869-1875, 2004
    • (2004) Spine , vol.29 , pp. 1869-1875
    • Kothe, R.1    Rüther, W.2    Schneider, E.3    Linke, B.4
  • 15
    • 0030926450 scopus 로고    scopus 로고
    • Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients
    • Laine T, Schlenzka D, Mäkitalo K, Tallroth K, Nolte LP, Visari us H: Improved accuracy of pedicle screw insertion with computer-assisted surgery. A prospective clinical trial of 30 patients. Spine 22:1254-1258, 1997
    • (1997) Spine , vol.22 , pp. 1254-1258
    • Laine, T.1    Schlenzka, D.2    Mäkitalo, K.3    Tallroth, K.4    Nolte, L.P.5    Visarius, H.6
  • 16
    • 35348900058 scopus 로고    scopus 로고
    • A comparison of two techniques in image-guided thoracic pedicle screw placement: A retrospective study of 37 patients and 277 pedicle screws
    • Lekovic GP, Potts EA, Karahalios DG, Hall G: A comparison of two techniques in image-guided thoracic pedicle screw placement: a retrospective study of 37 patients and 277 pedicle screws. J Neurosurg Spine 7:393-398, 2007
    • (2007) J Neurosurg Spine , vol.7 , pp. 393-398
    • Lekovic, G.P.1    Potts, E.A.2    Karahalios, D.G.3    Hall, G.4
  • 17
    • 0033925472 scopus 로고    scopus 로고
    • Placement of pedicle screws in the human cadaveric cervical spine: Comparative accuracy of three techniques
    • Ludwig SC, Kramer DL, Balderston RA, Vaccaro AR, Foley KF, Albert TJ: Placement of pedicle screws in the human cadaveric cervical spine: comparative accuracy of three techniques. Spine 25:1655-1667, 2000
    • (2000) Spine , vol.25 , pp. 1655-1667
    • Ludwig, S.C.1    Kramer, D.L.2    Balderston, R.A.3    Vaccaro, A.R.4    Foley, K.F.5    Albert, T.J.6
  • 18
    • 29444456659 scopus 로고    scopus 로고
    • The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae
    • Neo M, Sakamoto T, Fujibayashi S, Nakamura T: The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae. Spine 30:2800-2805, 2005
    • (2005) Spine , vol.30 , pp. 2800-2805
    • Neo, M.1    Sakamoto, T.2    Fujibayashi, S.3    Nakamura, T.4
  • 19
    • 61549092238 scopus 로고    scopus 로고
    • Placement of thoracolumbar pedicle screws using three-dimensional image guidance: Experience in a large patient cohort. Clinical article
    • Nottmeier EW, Seemer W, Young PM: Placement of thoracolumbar pedicle screws using three-dimensional image guidance: experience in a large patient cohort. Clinical article. J Neurosurg Spine 10:33-39, 2009
    • (2009) J Neurosurg Spine , vol.10 , pp. 33-39
    • Nottmeier, E.W.1    Seemer, W.2    Young, P.M.3
  • 20
    • 0034657288 scopus 로고    scopus 로고
    • Internal morphology of human cervical pedicles
    • Panjabi MM, Shin EK, Chen NC, Wang JL: Internal morphology of human cervical pedicles. Spine 25:1197-1205, 2000
    • (2000) Spine , vol.25 , pp. 1197-1205
    • Panjabi, M.M.1    Shin, E.K.2    Chen, N.C.3    Wang, J.L.4
  • 21
    • 33846239956 scopus 로고    scopus 로고
    • Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries
    • Rajasekaran S, Vidyadhara S, Ramesh P, Shetty AP: Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries. Spine 32:E56-E64, 2007
    • (2007) Spine , vol.32
    • Rajasekaran, S.1    Vidyadhara, S.2    Ramesh, P.3    Shetty, A.P.4
  • 22
    • 36749087583 scopus 로고    scopus 로고
    • Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: A case report
    • Rajasekaran S, Vidyadhara S, Shetty AP: Iso-C3D fluoroscopy-based navigation in direct pedicle screw fixation of Hangman fracture: a case report. J Spinal Disord Tech 20:616-619, 2007
    • (2007) J Spinal Disord Tech , vol.20 , pp. 616-619
    • Rajasekaran, S.1    Vidyadhara, S.2    Shetty, A.P.3
  • 23
    • 33644877691 scopus 로고    scopus 로고
    • Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: A CT analysis
    • Rampersaud YR, Pik JH, Salonen D, Farooq S: Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30:E183-E190, 2005
    • (2005) Spine , vol.30
    • Rampersaud, Y.R.1    Pik, J.H.2    Salonen, D.3    Farooq, S.4
  • 24
    • 27144527301 scopus 로고    scopus 로고
    • Cervical pedicle screws: Conventional versus computer-assisted placement of cannulated screws
    • Richter M, Cakir B, Schmidt R: Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws. Spine 30:2280-2287, 2005
    • (2005) Spine , vol.30 , pp. 2280-2287
    • Richter, M.1    Cakir, B.2    Schmidt, R.3
  • 25
    • 1442277695 scopus 로고    scopus 로고
    • Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
    • Richter M, Mattes T, Cakir B: Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine. Eur Spine J 13:50-59, 2004
    • (2004) Eur Spine J , vol.13 , pp. 50-59
    • Richter, M.1    Mattes, T.2    Cakir, B.3
  • 26
    • 14844347683 scopus 로고    scopus 로고
    • Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle
    • Sakamoto T, Neo M, Nakamura T: Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle. Spine 29:2510-2515, 2004
    • (2004) Spine , vol.29 , pp. 2510-2515
    • Sakamoto, T.1    Neo, M.2    Nakamura, T.3
  • 27
    • 0041472666 scopus 로고    scopus 로고
    • Pedicle screws enhance primary stability in multilevel cervical corpectomies: Biomechanical in vitro comparison of different im plants including constrained and nonconstrained posterior in strumentations
    • Schmidt R, Wilke HJ, Claes L, Puhl W, Richter M: Pedicle screws enhance primary stability in multilevel cervical corpectomies: biomechanical in vitro comparison of different im plants including constrained and nonconstrained posterior in strumentations. Spine 28:1821-1828, 2003
    • (2003) Spine , vol.28 , pp. 1821-1828
    • Schmidt, R.1    Wilke, H.J.2    Claes, L.3    Puhl, W.4    Richter, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.