메뉴 건너뛰기




Volumn 17, Issue 2, 2004, Pages 158-162

Posterior C2 Fixation Using Bilateral, Crossing C2 Laminar Screws: Case Series and Technical Note

Author keywords

Atlantoaxial stabilization; Axis; C2 fixation; Fusion; Laminar screw

Indexed keywords

ADULT; AGED; ANATOMICAL VARIATION; ARTERY OCCLUSION; ARTICLE; ATLANTOAXIAL JOINT; ATLANTOOCCIPITAL JOINT; BONE SCREW; CLINICAL ARTICLE; FEMALE; HUMAN; LAMINAR SCREW; MALE; OUTCOMES RESEARCH; PEDICLE SCREW; PRIORITY JOURNAL; SPINE FUSION; SPINE STABILIZATION; SURGICAL TECHNIQUE; VERTEBRAL ARTERY; BIOMECHANICS; BONE DISEASE; BONE PLATE; CERVICAL SPINE; CONTROLLED STUDY; FRACTURE FIXATION; JOINT STABILITY; TECHNIQUE;

EID: 1842686189     PISSN: 08950385     EISSN: None     Source Type: Journal    
DOI: 10.1097/00024720-200404000-00014     Document Type: Article
Times cited : (384)

References (14)
  • 1
    • 0017871668 scopus 로고
    • Atlantoaxial arthrodesis by the wedge compression method.
    • Brooks AL, Jenkins EB. Atlantoaxial arthrodesis by the wedge compression method. J Bone Joint Surg (Am). 1978;60:279-284.
    • (1978) J Bone Joint Surg (Am) , vol.60 , pp. 279-284
    • Brooks, A.L.1    Jenkins, E.B.2
  • 2
    • 0026092302 scopus 로고
    • The interspinous method of posterior atlantoaxial arthrodesis.
    • Dickman CA, Sonntag VK, Papadopoulos SM, et al. The interspinous method of posterior atlantoaxial arthrodesis. J Neurosurg. 1991;74:190-198.
    • (1991) J Neurosurg , vol.74 , pp. 190-198
    • Dickman, C.A.1    Sonntag, V.K.2    Papadopoulos, S.M.3
  • 3
    • 0032444557 scopus 로고    scopus 로고
    • Techniques of posterior C1-C2 stabilization.
    • Wright NM, Lauryssen C. Techniques of posterior C1-C2 stabilization. Techniques Neurosurg. 1998;4:286-297.
    • (1998) Techniques Neurosurg , vol.4 , pp. 286-297
    • Wright, N.M.1    Lauryssen, C.2
  • 4
    • 0026618885 scopus 로고
    • Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation.
    • Jeanneret B, Magerl F. Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation. J Spinal Disord. 1992;5:464-475.
    • (1992) J Spinal Disord , vol.5 , pp. 464-475
    • Jeanneret, B.1    Magerl, F.2
  • 5
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation.
    • Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine. 2001;26:2467-2471.
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 6
    • 0036481526 scopus 로고    scopus 로고
    • C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note.
    • Resnick DK, Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery. 2002;50:426-428.
    • (2002) Neurosurgery , vol.50 , pp. 426-428
    • Resnick, D.K.1    Benzel, E.C.2
  • 7
    • 0011832396 scopus 로고    scopus 로고
    • Posterior atlantoaxial stabilization: new alternative to C1-2 transarticular screws.
    • Stokes JK, Villavicencio AT, Liu PC, et al. Posterior atlantoaxial stabilization: new alternative to C1-2 transarticular screws. Neurosurg Focus. 2002;12:6.
    • (2002) Neurosurg Focus , vol.12 , pp. 6
    • Stokes, J.K.1    Villavicencio, A.T.2    Liu, P.C.3
  • 8
    • 0028284239 scopus 로고
    • Plate and screw fixation for atlantoaxial subluxation.
    • Goel A, Laheri V. Plate and screw fixation for atlantoaxial subluxation. Acta Neurochir (Wien). 1994;129:47-53.
    • (1994) Acta Neurochir (Wien) , vol.129 , pp. 47-53
    • Goel, A.1    Laheri, V.2
  • 9
    • 0036954405 scopus 로고    scopus 로고
    • Goel A, Desai KI, Muzumdar DP. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery. 2002;51: 1351-1357.
    • Goel A, Desai KI, Muzumdar DP. Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery. 2002;51: 1351-1357.
  • 10
    • 0036765950 scopus 로고    scopus 로고
    • C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note.
    • Goel A. C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery. 2002;51:853-854.
    • (2002) Neurosurgery , vol.51 , pp. 853-854
    • Goel, A.1
  • 11
    • 0029869526 scopus 로고    scopus 로고
    • Anatomic consideration of C2 pedicle screw placement.
    • Ebraheim N, Rollins JR, Xu R, et al. Anatomic consideration of C2 pedicle screw placement. Spine. 1996;21:691-694.
    • (1996) Spine , vol.21 , pp. 691-694
    • Ebraheim, N.1    Rollins, J.R.2    Xu, R.3
  • 12
    • 0026029275 scopus 로고
    • Posterior stabilization of the cervical spine with hook plates.
    • Jeanneret B, Magerl F, Ward EH, et al. Posterior stabilization of the cervical spine with hook plates. Spine. 1991;16:S56-S63.
    • (1991) Spine , vol.16
    • Jeanneret, B.1    Magerl, F.2    Ward, E.H.3
  • 13
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique.
    • Madawi AA, Casey AT, Solanki GA, et al. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86:961-968.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.2    Solanki, G.A.3
  • 14
    • 0031896021 scopus 로고    scopus 로고
    • Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg. 1998;88: 634-640.
    • Wright NM, Lauryssen C. Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg. 1998;88: 634-640.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.