메뉴 건너뛰기




Volumn 21, Issue SUPPL. 1, 2012, Pages

Free-hand pedicle screws insertion technique in the treatment of 120 consecutive scoliosis cases operated without use of intraoperative neurophysiological monitoring

Author keywords

Free hand technique; Pedicle screws; Pedicle violation; Scoliosis

Indexed keywords

ARTHRODESIS; ARTICLE; FEMALE; FREE HAND TECHNIQUE; HUMAN; IDIOPATHIC SCOLIOSIS; INSTRUMENTATION; INTRAOPERATIVE PERIOD; MAJOR CLINICAL STUDY; MALE; NEUROLOGIC DISEASE; NEUROMONITORING; PEDICLE SCREW; PEROPERATIVE CARE; PRIORITY JOURNAL; SCOLIOSIS; SURGICAL TECHNIQUE; THORACIC SPINAL CORD; VERTEBRA BODY;

EID: 84862865689     PISSN: 09406719     EISSN: 14320932     Source Type: Journal    
DOI: 10.1007/s00586-012-2218-y     Document Type: Article
Times cited : (16)

References (25)
  • 1
    • 0032076473 scopus 로고    scopus 로고
    • Anatomic considerations of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open-lamina technique
    • DOI 10.1097/00007632-199805010-00021
    • Xu R, Ebraheim NA, Ou Y, Yeasting RA (1998) Anatomic consideration of pedicle screw placement in the thoracic spine: Roy-Camille technique versus open-lamina technique. Spine 23(9):1065-1068 (Pubitemid 28242008)
    • (1998) Spine , vol.23 , Issue.9 , pp. 1065-1068
    • Xu, R.1    Ebraheim, N.A.2    Ou, Y.3    Yeasting, R.A.4
  • 2
    • 33645303790 scopus 로고    scopus 로고
    • Thoracic pedicle screw placement: Free-hand technique
    • Yongjung JK, Lenke LG (2005) Thoracic pedicle screw placement: free-hand technique. Neurol India 53(4):512-519
    • (2005) Neurol India , vol.53 , Issue.4 , pp. 512-519
    • Yongjung, J.K.1    Lenke, L.G.2
  • 3
    • 0035865653 scopus 로고    scopus 로고
    • Accuracy requirements for image-guided spinal pedicle screw placement
    • DOI 10.1097/00007632-200102150-00010
    • Rampersaud RR, Simon DA, Foley KT (2001) Accuracy requirements for image-guided spinal pedicle screw placement. Spine 26(4):352-359 (Pubitemid 32184847)
    • (2001) Spine , vol.26 , Issue.4 , pp. 352-359
    • Rampersaud, Y.R.1    Simon, D.A.2    Foley, K.T.3
  • 4
    • 0742269918 scopus 로고    scopus 로고
    • Thoracic pedicle morphometry in vertebrae from scoliotic spines
    • DOI 10.1097/01.BRS.0000109995.64028.FE
    • Parent S, Labelle H, Skalli W, de Guise J (2004) Thoracic pedicle morphometry in vertebrae from scoliotic spines. Spine 29:239-248 (Pubitemid 38155722)
    • (2004) Spine , vol.29 , Issue.3 , pp. 239-248
    • Parent, S.1    Labelle, H.2    Skalli, W.3    De Guise, J.4
  • 5
    • 0024510133 scopus 로고
    • Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size
    • DOI 10.1097/00007632-198904000-00004
    • Misenheimer GR, Peek RD, Wiltse LL, Rothman SL, Widell EH (1989) Anatomic analysis of pedicle cortical and cancellous diameter as related to screw size. Spine 14:367-372 (Pubitemid 19129716)
    • (1989) Spine , vol.14 , Issue.4 , pp. 367-372
    • Misenhimer, G.R.1    Peek, R.D.2    Wiltse, L.L.3    Rothman, S.L.G.4    Widell Jr., E.H.5
  • 6
    • 0030022014 scopus 로고    scopus 로고
    • Internal architecture of the thoracic pedicle. An anatomic study
    • Kothe R, O'Holleran JD, Liu W, Panjabi MM (1996) Internal architecture of the thoracic pedicle. An anatomic study. Spine 21:264-270
    • (1996) Spine , vol.21 , pp. 264-270
    • Kothe, R.1    O'Holleran, J.D.2    Liu, W.3    Panjabi, M.M.4
  • 7
    • 0027445917 scopus 로고
    • Pedicle morphology of the lower thoracic and lumbar spine in a Chinese population
    • Hou S, Hu R, Shi Y (1993) Pedicle morphology of the lower thoracic and lumbar spine in a Chinese population. Spine 18:1850-1855 (Pubitemid 23312842)
    • (1993) Spine , vol.18 , Issue.13 , pp. 1850-1855
    • Hou, S.1    Hu, R.2    Shi, Y.3
  • 11
    • 0031417450 scopus 로고    scopus 로고
    • Anatomic relations of the thoracic pedicle to the adjacent neural structures
    • DOI 10.1097/00007632-199707150-00002
    • Ebraheim NA, Jabaly G, Xu R, Yeasting RA (1997) Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine 22:1553-1557 (Pubitemid 28112825)
    • (1997) Spine , vol.22 , Issue.14 , pp. 1553-1557
    • Ebraheim, N.A.1    Jabaly, G.2    Xu, R.3    Yeasting, R.A.4
  • 13
    • 0033555322 scopus 로고    scopus 로고
    • Pedicle instrumentation in the thoracic spine: A morphometric and cadaveric study for placement of screws
    • DOI 10.1097/00007632-199901150-00003
    • Cinotti G, Gumina S, Ripani M, Postacchini F (1999) Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine 24:114-119 (Pubitemid 29042758)
    • (1999) Spine , vol.24 , Issue.2 , pp. 114-119
    • Cinotti, G.1    Gumina, S.2    Ripani, M.3    Postacchini, F.4
  • 14
    • 77249148879 scopus 로고    scopus 로고
    • Free hand technique for thoracolumbar pedicle screw instrumentation: Critical appraisal of current "State of art"
    • Mattei TA, Meneses MS, Milano JB, Ramina R (2009) Free hand technique for thoracolumbar pedicle screw instrumentation: critical appraisal of current "State of Art". Neurol India 57:715-721
    • (2009) Neurol India , vol.57 , pp. 715-721
    • Mattei, T.A.1    Meneses, M.S.2    Milano, J.B.3    Ramina, R.4
  • 15
    • 0742269914 scopus 로고    scopus 로고
    • Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe
    • DOI 10.1097/01.BRS.0000109983.12113.9B
    • Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29(3):333-342 (Pubitemid 38155737)
    • (2004) Spine , vol.29 , Issue.3 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3    Cho, Y.S.4    Riew, K.D.5
  • 16
    • 52649105308 scopus 로고    scopus 로고
    • Ideal entry point for the thoracic pedicle screw during the free hand technique
    • Chung KJ, Shu SW, Desai S, Song HR (2008) Ideal entry point for the thoracic pedicle screw during the free hand technique. Int Orthop 32:657-662
    • (2008) Int Orthop , vol.32 , pp. 657-662
    • Chung, K.J.1    Shu, S.W.2    Desai, S.3    Song, H.R.4
  • 18
    • 0029044493 scopus 로고
    • Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography
    • Farber GL, Place HM, Mazur RA, Jones DE, Damiano TR (1995) Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine 20:1494-1499
    • (1995) Spine , vol.20 , pp. 1494-1499
    • Farber, G.L.1    Place, H.M.2    Mazur, R.A.3    Jones, D.E.4    Damiano, T.R.5
  • 19
    • 0031439898 scopus 로고    scopus 로고
    • Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction
    • Berlemann U, Heini P, Muller U, Stoupis C, Schwarzenbach O (1997) Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction. Eur Spine J 6:406-410
    • (1997) Eur Spine J , vol.6 , pp. 406-410
    • Berlemann, U.1    Heini, P.2    Muller, U.3    Stoupis, C.4    Schwarzenbach, O.5
  • 20
    • 0031413907 scopus 로고    scopus 로고
    • Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
    • DOI 10.1097/00007632-199710010-00008
    • Liljenqvist UR, Halm HF, Link TM (1997) Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine 22:2239-2245 (Pubitemid 28074054)
    • (1997) Spine , vol.22 , Issue.19 , pp. 2239-2245
    • Liljenqvist, U.R.1    Halm, H.F.H.2    Link, T.M.3
  • 21
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • DOI 10.1097/00007632-198809000-00008
    • Weinstein JN, Spratt KF, Spengler D, Brick C, Reid S (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012-1018 (Pubitemid 18266476)
    • (1988) Spine , vol.13 , Issue.9 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3    Brick, C.4    Reid, S.5
  • 23
    • 0033834682 scopus 로고    scopus 로고
    • Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis
    • Halm HF, Niemer T, Link TM (2000) Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis. Eur Spine J 9:192-197
    • (2000) Eur Spine J , vol.9 , pp. 192-197
    • Halm, H.F.1    Niemer, T.2    Link, T.M.3
  • 24
    • 0035500223 scopus 로고    scopus 로고
    • In vivo accuracy of thoracic pedicle screws
    • DOI 10.1097/00007632-200111010-00010
    • Belmont PJ, Klemme WR, Dhawan A (2001) In vivo accuracy of thoracic pedicle screws. Spine 26:2340-2346 (Pubitemid 33043316)
    • (2001) Spine , vol.26 , Issue.21 , pp. 2340-2346
    • Belmont Jr., P.J.1    Klemme, W.R.2    Dhawan, A.3    Polly Jr., D.W.4
  • 25
    • 0032912834 scopus 로고    scopus 로고
    • Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis
    • DOI 10.1007/s005860050147
    • Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M (1999) Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J 8:156-160 (Pubitemid 29217252)
    • (1999) European Spine Journal , vol.8 , Issue.2 , pp. 156-160
    • Papin, P.1    Arlet, V.2    Marchesi, D.3    Rosenblatt, B.4    Aebi, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.