메뉴 건너뛰기




Volumn 6, Issue 1, 2014, Pages 11-28

Towards nano-diagnostics for rapid diagnosis of infectious diseases-current technological state

Author keywords

lateral flow devices; microfluidics; nano diagnostics; nanoparticles; nanotechnology; point of care

Indexed keywords

MICROFLUIDICS; NANOPARTICLES; NANOTECHNOLOGY;

EID: 84898942127     PISSN: 16625986     EISSN: 1662596X     Source Type: Journal    
DOI: 10.1515/ejnm-2014-0004     Document Type: Review
Times cited : (17)

References (85)
  • 1
    • 67649297821 scopus 로고    scopus 로고
    • Emergence and pandemic potential of swine-origin H1N1 influenza virus
    • Neumann G, Noda T, Kawaoka Y. Emergence and pandemic potential of swine-origin H1N1 influenza virus. Nature 2009;459:931-9.
    • (2009) Nature , vol.459 , pp. 931-939
    • Neumann, G.1    Noda, T.2    Kawaoka, Y.3
  • 2
    • 78650407591 scopus 로고    scopus 로고
    • Tackling HIV through robust diagnostics in the developing world: Current status and future opportunities
    • Desai D, Wu G, Zaman MH. Tackling HIV through robust diagnostics in the developing world: current status and future opportunities. Lab Chip 2011;11:194-211.
    • (2011) Lab Chip , vol.11 , pp. 194-211
    • Desai, D.1    Wu, G.2    Zaman, M.H.3
  • 3
    • 76849101592 scopus 로고    scopus 로고
    • Nanotechnology diagnostics for infectious diseases prevalent in developing countries
    • Hauck TS, Giri S, Gao Y, Chan WC. Nanotechnology diagnostics for infectious diseases prevalent in developing countries. Adv Drug Deliver Rev 2010;62:438-48.
    • (2010) Adv Drug Deliver Rev , vol.62 , pp. 438-448
    • Hauck, T.S.1    Giri, S.2    Gao, Y.3    Chan, W.C.4
  • 6
    • 79951727215 scopus 로고    scopus 로고
    • Biofunctionalized indigo-nanoparticles as biolabels for the generation of precipitated visible signal in immunodipsticks
    • Mak WC, Sin KK, Chan CP, Wong LW, Renneberg R. Biofunctionalized indigo-nanoparticles as biolabels for the generation of precipitated visible signal in immunodipsticks. Biosensors Bioelectronics 2011;26:3148-53.
    • (2011) Biosensors Bioelectronics , vol.26 , pp. 3148-3153
    • Mak, W.C.1    Sin, K.K.2    Chan, C.P.3    Wong, L.W.4    Renneberg, R.5
  • 7
    • 84867332646 scopus 로고    scopus 로고
    • Enhancing the lateral-flow immunoassay for detection of proteins using an aqueous two-phase micellar system
    • Mashayekhi F, Le AM, Nafisi PM, Wu BM, Kamei DT. Enhancing the lateral-flow immunoassay for detection of proteins using an aqueous two-phase micellar system. Anal Bioanal Chem 2012;404:2057-66.
    • (2012) Anal Bioanal Chem , vol.404 , pp. 2057-2066
    • Mashayekhi, F.1    Le, A.M.2    Nafisi, P.M.3    Wu, B.M.4    Kamei, D.T.5
  • 12
    • 84876099601 scopus 로고    scopus 로고
    • Advances in microfluidic materials, functions, integration, and applications
    • Nge PN, Rogers CI, Woolley AT. Advances in microfluidic materials, functions, integration, and applications. Chem Rev 2013;113:2550-83.
    • (2013) Chem Rev , vol.113 , pp. 2550-2583
    • Nge, P.N.1    Rogers, C.I.2    Woolley, A.T.3
  • 14
    • 52649159923 scopus 로고    scopus 로고
    • A microfluidic flow injection system for DNA assay with fluids driven by an on-chip integrated pump based on capillary and evaporation effects
    • Xu ZR, Zhong CH, Guan YX, Chen XW, Wang JH, Fang ZL. A microfluidic flow injection system for DNA assay with fluids driven by an on-chip integrated pump based on capillary and evaporation effects. Lab Chip 2008;8:1658-63.
    • (2008) Lab Chip , vol.8 , pp. 1658-1663
    • Xu, Z.R.1    Zhong, C.H.2    Guan, Y.X.3    Chen, X.W.4    Wang, J.H.5    Fang, Z.L.6
  • 16
    • 70249131172 scopus 로고    scopus 로고
    • Development of an all-fluoroplastic microfluidic device applied as a nanoliter sample injector Jpn
    • Sato T, Kawai K, Kanai M, Shoji S. Development of an all-fluoroplastic microfluidic device applied as a nanoliter sample injector Jpn. J Appl Phys 2009;48:06FJ03.
    • (2009) J Appl Phys , vol.48
    • Sato, T.1    Kawai, K.2    Kanai, M.3    Shoji, S.4
  • 17
    • 84880933921 scopus 로고    scopus 로고
    • Microdialysis sampling coupled to microchip electrophoresis with integrated amperometric detection on an all-glass substrate
    • Scott DE, Grigsby RJ, Lunt SM. Microdialysis sampling coupled to microchip electrophoresis with integrated amperometric detection on an all-glass substrate. ChemPhysChem 2013;14:2288-94.
    • (2013) ChemPhysChem , vol.14 , pp. 2288-2294
    • Scott, D.E.1    Grigsby, R.J.2    Lunt, S.M.3
  • 18
    • 84880987128 scopus 로고    scopus 로고
    • Lab on a chip for in situ diagnosis: From blood to point of care
    • Lee J, Lee SH. Lab on a chip for in situ diagnosis: from blood to point of care. Biomed Eng Lett 2013;3:59-66.
    • (2013) Biomed Eng Lett , vol.3 , pp. 59-66
    • Lee, J.1    Lee, S.H.2
  • 19
    • 79957970113 scopus 로고    scopus 로고
    • A vacuum-driven peristaltic micropump with valved actuation chambers
    • Cui J, Pan T. A vacuum-driven peristaltic micropump with valved actuation chambers. J Micromech Microeng 2011;21:065034.
    • (2011) J Micromech Microeng , vol.21 , pp. 065034
    • Cui, J.1    Pan, T.2
  • 20
    • 67349245781 scopus 로고    scopus 로고
    • A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure
    • Yang YN, Hsiun SK, Lee GB. A pneumatic micropump incorporated with a normally closed valve capable of generating a high pumping rate and a high back pressure. Microfluid Nanofluid 2009;6:823-33.
    • (2009) Microfluid Nanofluid , vol.6 , pp. 823-833
    • Yang, Y.N.1    Hsiun, S.K.2    Lee, G.B.3
  • 23
    • 77951920946 scopus 로고    scopus 로고
    • Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics
    • Hunag CC, Bazant MZ, Thorsen T. Ultrafast high-pressure AC electro-osmotic pumps for portable biomedical microfluidics. Lab Chip 2010;10:80-5.
    • (2010) Lab Chip , vol.10 , pp. 80-85
    • Hunag, C.C.1    Bazant, M.Z.2    Thorsen, T.3
  • 24
    • 77957866991 scopus 로고    scopus 로고
    • Mixing enhancement in microfluidic channel with a constriction under periodic electro-osmotic flow
    • Lim CY, Lam YC, Yang C. Mixing enhancement in microfluidic channel with a constriction under periodic electro-osmotic flow. Biomicrofluidics 2010;4:14101.
    • (2010) Biomicrofluidics , vol.4 , pp. 14101
    • Lim, C.Y.1    Lam, Y.C.2    Yang, C.3
  • 26
    • 4143091025 scopus 로고    scopus 로고
    • Electro-hydrodynamic microfluidic mixer
    • El Moctar AO, Aubry N, Batton J. Electro-hydrodynamic microfluidic mixer. Lab Chip 2003;3:273-80.
    • (2003) Lab Chip , vol.3 , pp. 273-280
    • El Moctar, A.O.1    Aubry, N.2    Batton, J.3
  • 28
    • 84862166539 scopus 로고    scopus 로고
    • A disposable picolitre bioreactor for cultivation and investigation of industrially relevant bacteria on the single cell level
    • Grberger A, Paczia N, Probst C, Schendzielorz G, Eggeling L, Noack S, et al. A disposable picolitre bioreactor for cultivation and investigation of industrially relevant bacteria on the single cell level. Lab Chip 2012;12:2060-8.
    • (2012) Lab Chip , vol.12 , pp. 2060-2068
    • Grberger, A.1    Paczia, N.2    Probst, C.3    Schendzielorz, G.4    Eggeling, L.5    Noack, S.6
  • 29
    • 84859571453 scopus 로고    scopus 로고
    • A new rapid method for clostridium difficile DNA extraction and detection in stool. Toward point-of-care diagnostic testing
    • Freifeld AG, Simonsen KA, Booth CS, Zhao X, Whitneu SE, Karre T, et al. A new rapid method for clostridium difficile DNA extraction and detection in stool. Toward point-of-care diagnostic testing. Journal of Molecular Diagnostics 2012;14:274-9.
    • (2012) Journal of Molecular Diagnostics , vol.14 , pp. 274-279
    • Freifeld, A.G.1    Simonsen, K.A.2    Booth, C.S.3    Zhao, X.4    Whitneu, S.E.5    Karre, T.6
  • 30
  • 31
    • 1642287457 scopus 로고    scopus 로고
    • Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks
    • Wolf M, Juncker D, Michel B, Hunziker P, Delamarche E. Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks. Biosens Bioelectron 2004;19:1193-202.
    • (2004) Biosens Bioelectron , vol.19 , pp. 1193-1202
    • Wolf, M.1    Juncker, D.2    Michel, B.3    Hunziker, P.4    Delamarche, E.5
  • 33
    • 84872417070 scopus 로고    scopus 로고
    • Real-time and label-free bio-sensing of molecular interactions by surface plasmon resonance: A laboratory medicine perspective
    • Helmerhorst E, Chandler DJ, Nussio M, Mamotte CD. Real-time and label-free bio-sensing of molecular interactions by surface plasmon resonance: a laboratory medicine perspective. Clin Biochem Rev 2012;33:161-73.
    • (2012) Clin Biochem Rev , vol.33 , pp. 161-173
    • Helmerhorst, E.1    Chandler, D.J.2    Nussio, M.3    Mamotte, C.D.4
  • 34
    • 84868583139 scopus 로고    scopus 로고
    • Capillary-driven toner-based microfluidic devices for clinical diagnostics with colorimetric detection
    • de Souza FR, Alves GL, Coltro WK. Capillary-driven toner-based microfluidic devices for clinical diagnostics with colorimetric detection. Anal Chem 2012;84:9002-7.
    • (2012) Anal Chem , vol.84 , pp. 9002-9007
    • De Souza, F.R.1    Alves, G.L.2    Coltro, W.K.3
  • 35
    • 84866361048 scopus 로고    scopus 로고
    • Immunochromatographic assay on thread
    • Zhou G, Mao X, Juncker D. Immunochromatographic assay on thread. Anal Chem 2012;84:7736-43.
    • (2012) Anal Chem , vol.84 , pp. 7736-7743
    • Zhou, G.1    Mao, X.2    Juncker, D.3
  • 36
    • 20944444560 scopus 로고    scopus 로고
    • Modeling and optimization of high-sensitivity, low-volume microfluidicbased surface immunoassays
    • Zimmermann M, Delamarche E, Wolf M, Hunziker P. Modeling and optimization of high-sensitivity, low-volume microfluidicbased surface immunoassays. Biomed Microdevices 2005;7:99-110.
    • (2005) Biomed Microdevices , vol.7 , pp. 99-110
    • Zimmermann, M.1    Delamarche, E.2    Wolf, M.3    Hunziker, P.4
  • 38
    • 84872711228 scopus 로고    scopus 로고
    • Numerical simulation of cell adhesion and detachment in microfluidics
    • Bai B, Luo Z, Lu T, Xu F. Numerical simulation of cell adhesion and detachment in microfluidics. J Mech Med Biol 2013;13:1350002.
    • (2013) J Mech Med Biol , vol.13 , pp. 1350002
    • Bai, B.1    Luo, Z.2    Lu, T.3    Xu, F.4
  • 39
    • 84898976846 scopus 로고    scopus 로고
    • Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect
    • Yuan Q, Yang K, Wu J. Optimization of planar interdigitated microelectrode array for biofluid transport by AC electrothermal effect. Microfluid Nanofluid 2014;16:167-78.
    • (2014) Microfluid Nanofluid , vol.16 , pp. 167-178
    • Yuan, Q.1    Yang, K.2    Wu, J.3
  • 40
    • 80053645514 scopus 로고    scopus 로고
    • Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay
    • Yang Z, Zong C, Ju H, Yan F. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay. Anal Chim Acta 2011;706:143-8.
    • (2011) Anal Chim Acta , vol.706 , pp. 143-148
    • Yang, Z.1    Zong, C.2    Ju, H.3    Yan, F.4
  • 41
    • 84855964604 scopus 로고    scopus 로고
    • A Wash-free, electrochemical platform for the quantitative, multiplexed detection of specific antibodies
    • White RJ, Kallewaard HM, Hsieh W, Patterson AS, Kasehagen JB, Cash KJ, et al. A Wash-free, electrochemical platform for the quantitative, multiplexed detection of specific antibodies. Anal Chem 2012; 84:1098-103.
    • (2012) Anal Chem , vol.84 , pp. 1098-1103
    • White, R.J.1    Kallewaard, H.M.2    Hsieh, W.3    Patterson, A.S.4    Kasehagen, J.B.5    Cash, K.J.6
  • 43
    • 79954414628 scopus 로고    scopus 로고
    • Unconventional low-cost fabrication and patterning techniques for point of care diagnostics
    • Sharma H, Nguyen D, Chen A, Lew V, Khine M. Unconventional low-cost fabrication and patterning techniques for point of care diagnostics. Ann Biomed Eng 2011;39:1313-27.
    • (2011) Ann Biomed Eng , vol.39 , pp. 1313-1327
    • Sharma, H.1    Nguyen, D.2    Chen, A.3    Lew, V.4    Khine, M.5
  • 44
    • 84857315162 scopus 로고    scopus 로고
    • Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards
    • Lafleur L, Stevens D, McKenzie K, Ramachandran S, Spicar-Mihalic P, Singhal M, et al. Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards. Lab Chip 2012;12:1119-27.
    • (2012) Lab Chip , vol.12 , pp. 1119-1127
    • Lafleur, L.1    Stevens, D.2    McKenzie, K.3    Ramachandran, S.4    Spicar-Mihalic, P.5    Singhal, M.6
  • 45
    • 84870850588 scopus 로고    scopus 로고
    • On-chip dual detection of cancer biomarkers directly in serum based on self-assembled magnetic bead patterns and quantum dots
    • Yu X, Xia HS, Sun ZD, Lin Y, Wang K, Yu J, et al. On-chip dual detection of cancer biomarkers directly in serum based on self-assembled magnetic bead patterns and quantum dots. Biosens Bioelectron 2013;41:129-36.
    • (2013) Biosens Bioelectron , vol.41 , pp. 129-136
    • Yu, X.1    Xia, H.S.2    Sun, Z.D.3    Lin, Y.4    Wang, K.5    Yu, J.6
  • 46
    • 84862788671 scopus 로고    scopus 로고
    • Rapid detection of fish major allergen parvalbumin using superparamagnetic nanoparticle-based lateral flow immunoassay
    • Zheng C, Wang X, Lu Y, Liu Y. Rapid detection of fish major allergen parvalbumin using superparamagnetic nanoparticle-based lateral flow immunoassay. Food Control 2012;26:446-52.
    • (2012) Food Control , vol.26 , pp. 446-452
    • Zheng, C.1    Wang, X.2    Lu, Y.3    Liu, Y.4
  • 47
    • 80052192097 scopus 로고    scopus 로고
    • Effect of surface nanotopography on immunoaffinity cell capture in microfluidic devices
    • Wang B, Weldon AL, Kumnorkaew P, Xu B, Gilchrist JF, Cheng X. Effect of surface nanotopography on immunoaffinity cell capture in microfluidic devices. Langmuir 2011;27:11229-37.
    • (2011) Langmuir , vol.27 , pp. 11229-11237
    • Wang, B.1    Weldon, A.L.2    Kumnorkaew, P.3    Xu, B.4    Gilchrist, J.F.5    Cheng, X.6
  • 49
    • 84863983216 scopus 로고    scopus 로고
    • GMR sensors and magnetic nanoparticles for immuno-chromatographic assays. Biosens Bioelectron
    • Marquina C, de Teresa JM, Serrate D, Marzo J, Cardoso FA, Saurel D, et al. GMR sensors and magnetic nanoparticles for immuno-chromatographic assays. Biosens Bioelectron. J Mag and Mag Mat 2012;324:3495-8.
    • (2012) J Mag and Mag Mat , vol.324 , pp. 3495-3498
    • Marquina, C.1    De Teresa, J.M.2    Serrate, D.3    Marzo, J.4    Cardoso, F.A.5    Saurel, D.6
  • 50
    • 42149174270 scopus 로고    scopus 로고
    • Detection of 130nm magnetic particles by a portable electronic platform using spin valve and magnetic tunnel junction sensors
    • Cardoso FA, Germano J, Ferreira R, Cardoso S, Martins VC, Freitas PP, et al. Detection of 130nm magnetic particles by a portable electronic platform using spin valve and magnetic tunnel junction sensors. J App Phys 2008;103:07A310.
    • (2008) J App Phys , vol.103
    • Cardoso, F.A.1    Germano, J.2    Ferreira, R.3    Cardoso, S.4    Martins, V.C.5    Freitas, P.P.6
  • 51
    • 79952584954 scopus 로고    scopus 로고
    • Gold nanoparticle layer: A promising platform for ultra-sensitive cancer detection
    • Zhou F, Yuan L, Wang H, Li D, Chen H. Gold nanoparticle layer: a promising platform for ultra-sensitive cancer detection. Langmuir 2011;27:2155-8.
    • (2011) Langmuir , vol.27 , pp. 2155-2158
    • Zhou, F.1    Yuan, L.2    Wang, H.3    Li, D.4    Chen, H.5
  • 52
    • 84860248723 scopus 로고    scopus 로고
    • Sensitive sandwich ELISA based on a gold nanoparticle layer for cancer detection
    • Zhou F, Wang M, Yuan L, Cheng Z, Wu Z, Chen H. Sensitive sandwich ELISA based on a gold nanoparticle layer for cancer detection. Analyst 2012;137:1779-84.
    • (2012) Analyst , vol.137 , pp. 1779-1784
    • Zhou, F.1    Wang, M.2    Yuan, L.3    Cheng, Z.4    Wu, Z.5    Chen, H.6
  • 53
    • 84863471612 scopus 로고    scopus 로고
    • Performance of fluorescent europium(III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay
    • Juntunen E, Myyrylnen T, Salminen T, Soukka T, Pettersson K. Performance of fluorescent europium(III) nanoparticles and colloidal gold reporters in lateral flow bioaffinity assay. Anal Biochem 2012;428:31-8.
    • (2012) Anal Biochem , vol.428 , pp. 31-38
    • Juntunen, E.1    Myyrylnen, T.2    Salminen, T.3    Soukka, T.4    Pettersson, K.5
  • 54
    • 84870773275 scopus 로고    scopus 로고
    • A multiplex and straightforward aqueous phase immunoassay protocol through the combination of SERS-fluorescence dual mode nanoprobes and magnetic nanobeads
    • Zong S, Wang Z, Zhang R, Wang C, Xu S, Cui Y. A multiplex and straightforward aqueous phase immunoassay protocol through the combination of SERS-fluorescence dual mode nanoprobes and magnetic nanobeads. Biosens Bioelectron 2013;41:745-51.
    • (2013) Biosens Bioelectron , vol.41 , pp. 745-751
    • Zong, S.1    Wang, Z.2    Zhang, R.3    Wang, C.4    Xu, S.5    Cui, Y.6
  • 55
    • 79251573872 scopus 로고    scopus 로고
    • Carbon nanoparticles in lateral flow methods to detect genes encoding virulence factors of Shiga toxin-producing Escherichia coli
    • Noguera P, Posthuma-Trumpie GA, van Tuil M, van der Wal FJ, de Boer A, Moers AP, et al. Carbon nanoparticles in lateral flow methods to detect genes encoding virulence factors of Shiga toxin-producing Escherichia coli. Anal Bioanal Chem 2011;399:831-8.
    • (2011) Anal Bioanal Chem , vol.399 , pp. 831-838
    • Noguera, P.1    Posthuma-Trumpie, G.A.2    Van Tuil, M.3    Van Der Wal, F.J.4    De Boer, A.5    Moers, A.P.6
  • 58
    • 77953657460 scopus 로고    scopus 로고
    • Label-freetoxin detection by meansof time-resolved electrochemical impedance spectroscopy
    • Chai C, Takhistov P. Label-freetoxin detection by meansof time-resolved electrochemical impedance spectroscopy. Sensors (Basel) 2010;10:655-69.
    • (2010) Sensors (Basel) , vol.10 , pp. 655-669
    • Chai, C.1    Takhistov, P.2
  • 59
    • 84878268517 scopus 로고    scopus 로고
    • Silicon nanosensor for diagnosis of cardiovascular proteomic markers
    • Prasad S, Selvam AP, Reddy RK, Love A. Silicon nanosensor for diagnosis of cardiovascular proteomic markers. J Lab Autom 2013;18:143-51.
    • (2013) J Lab Autom , vol.18 , pp. 143-151
    • Prasad, S.1    Selvam, A.P.2    Reddy, R.K.3    Love, A.4
  • 60
    • 84859879032 scopus 로고    scopus 로고
    • Development of an electrochemical membrane-based nanobiosensor for ultrasensitive detection of dengue virus
    • Cheng MS, Ho JS, Tan CH, Wong JP, Ng LC, Toh CS. Development of an electrochemical membrane-based nanobiosensor for ultrasensitive detection of dengue virus. Anal Chim Acta 2012;725:74-80.
    • (2012) Anal Chim Acta , vol.725 , pp. 74-80
    • Cheng, M.S.1    Ho, J.S.2    Tan, C.H.3    Wong, J.P.4    Ng, L.C.5    Toh, C.S.6
  • 61
    • 84863088370 scopus 로고    scopus 로고
    • Electrochemical impedance spectroscopy characterization of nanoporous alumina dengue virus biosensor
    • Nguyen BT, Peh AE, Chee CY, Fink K, Chow VT, Ng MM, et al. Electrochemical impedance spectroscopy characterization of nanoporous alumina dengue virus biosensor. ioelectrochemistry 2012;88:15-21.
    • (2012) Ioelectrochemistry , vol.88 , pp. 15-21
    • Nguyen, B.T.1    Peh, A.E.2    Chee, C.Y.3    Fink, K.4    Chow, V.T.5    Ng, M.M.6
  • 62
    • 84871657142 scopus 로고    scopus 로고
    • Dengue virus detection using impedance measured across nanoporous alumina membrane
    • Peh AE, Li SF. Dengue virus detection using impedance measured across nanoporous alumina membrane. Biosens Bioelectron 2013;42:391-6.
    • (2013) Biosens Bioelectron , vol.42 , pp. 391-396
    • Peh, A.E.1    Li, S.F.2
  • 63
    • 24744433042 scopus 로고    scopus 로고
    • Million-fold preconcentration of proteins and peptides by nanofluidic filter
    • Wang YC, Stevens AL, Han J. Million-fold preconcentration of proteins and peptides by nanofluidic filter. Anal Chem 2005;77:4293-9.
    • (2005) Anal Chem , vol.77 , pp. 4293-4299
    • Wang, Y.C.1    Stevens, A.L.2    Han, J.3
  • 64
    • 67649964517 scopus 로고    scopus 로고
    • High speed nanofluidic protein accumulator
    • Wu D, Steckl A. High speed nanofluidic protein accumulator. Lab Chip 2009;9:1890-6.
    • (2009) Lab Chip , vol.9 , pp. 1890-1896
    • Wu, D.1    Steckl, A.2
  • 65
    • 0035902938 scopus 로고    scopus 로고
    • Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species
    • Cui Y, Wei Q, Park H, Lieber CM. Nanowire nanosensors for highly sensitive and selective detection of biological and chemical species. Science 2001;293:1289-92.
    • (2001) Science , vol.293 , pp. 1289-1292
    • Cui, Y.1    Wei, Q.2    Park, H.3    Lieber, C.M.4
  • 67
  • 68
    • 77951218268 scopus 로고    scopus 로고
    • Label-free attomolar detection of proteins using integrated nanoelectronic and electrokinetic devices
    • Gong JR. Label-free attomolar detection of proteins using integrated nanoelectronic and electrokinetic devices. Small 2010;6:967-73.
    • (2010) Small , vol.6 , pp. 967-973
    • Gong, J.R.1
  • 69
    • 84883472789 scopus 로고    scopus 로고
    • Programmable interactions of functionalized single bioparticles in a dielectrophoresis-based microarray chip
    • Abonnenc M, Manaresi N, Borgatti M, Medoro G, Fabbri E, Romani A, et al. Programmable interactions of functionalized single bioparticles in a dielectrophoresis-based microarray chip. Anal Chem 2013;85:8219-24.
    • (2013) Anal Chem , vol.85 , pp. 8219-8224
    • Abonnenc, M.1    Manaresi, N.2    Borgatti, M.3    Medoro, G.4    Fabbri, E.5    Romani, A.6
  • 70
    • 0035298847 scopus 로고    scopus 로고
    • Cantilever-based optical deflection assay for discrimination of dna single-nucleotide mismatches
    • Hansen KM, Ji HF, Wu G, Datar R, Cote R, Majumdar A, et al. Cantilever-based optical deflection assay for discrimination of dna single-nucleotide mismatches. Anal Chem 2001;73: 1567-71.
    • (2001) Anal Chem , vol.73 , pp. 1567-1571
    • Hansen, K.M.1    Ji, H.F.2    Wu, G.3    Datar, R.4    Cote, R.5    Majumdar, A.6
  • 73
    • 77953579671 scopus 로고    scopus 로고
    • Seeing and Counting individual antigens captured on a microarrayed spot with force-based atomic force microscopy
    • Roy D, Kwon SH, Kwak JW, Park JW. " Seeing and Counting" individual antigens captured on a microarrayed spot with force-based atomic force microscopy. Anal Chem 2010;82: 5189-94.
    • (2010) Anal Chem , vol.82 , pp. 5189-5194
    • Roy, D.1    Kwon, S.H.2    Kwak, J.W.3    Park, J.W.4
  • 74
    • 18444405555 scopus 로고    scopus 로고
    • Rapid biosensor for detection of antibiotic-selective growth of Escherichia coli
    • Gfeller KY, Nugaeva N, Hegner M. Rapid biosensor for detection of antibiotic-selective growth of Escherichia coli. Appl Environ Microbiol 2005;71:2626-31.
    • (2005) Appl Environ Microbiol , vol.71 , pp. 2626-2631
    • Gfeller, K.Y.1    Nugaeva, N.2    Hegner, M.3
  • 75
    • 46149114366 scopus 로고    scopus 로고
    • Living cantilever arrays' for characterization of mass of single live cells in fluids
    • Park K, Jang J, Irimia D, Sturgis J, Lee J, Robinson JP, et al. 'Living cantilever arrays' for characterization of mass of single live cells in fluids. Lab Chip 2008;8:1034-41.
    • (2008) Lab Chip , vol.8 , pp. 1034-1041
    • Park, K.1    Jang, J.2    Irimia, D.3    Sturgis, J.4    Lee, J.5    Robinson, J.P.6
  • 76
    • 34247612361 scopus 로고    scopus 로고
    • Weighing of biomolecules, single cells and single nanoparticles in fluid
    • Burg TP, Godin M, Knudsen SM, Shen W, Carlson G, Foster JS, et al. Weighing of biomolecules, single cells and single nanoparticles in fluid. Nature 2007;446:1066-9.
    • (2007) Nature , vol.446 , pp. 1066-1069
    • Burg, T.P.1    Godin, M.2    Knudsen, S.M.3    Shen, W.4    Carlson, G.5    Foster, J.S.6
  • 77
    • 85025261308 scopus 로고    scopus 로고
    • Clinical studies: Diagnosing disease by nanomechanical olfactory sensors-system design and clinical validation
    • Schmid D, Lang H, Marsch S, Gerber C, Hunziker P. Clinical studies: diagnosing disease by nanomechanical olfactory sensors-system design and clinical validation. Eur J Nanomed 2008;1:44-7.
    • (2008) Eur J Nanomed , vol.1 , pp. 44-47
    • Schmid, D.1    Lang, H.2    Marsch, S.3    Gerber, C.4    Hunziker, P.5
  • 78
    • 48249150392 scopus 로고    scopus 로고
    • Cantilever biosensors
    • Frits J. Cantilever biosensors. Analyst 2008;133:855-63.
    • (2008) Analyst , vol.133 , pp. 855-863
    • Frits, J.1
  • 79
    • 84855813503 scopus 로고    scopus 로고
    • Biosensing using dynamic-mode cantilever sensors: A review
    • Johnson BN, Mutharasan R. Biosensing using dynamic-mode cantilever sensors: a review. Biosens Bioelectron 2012;32:1-18.
    • (2012) Biosens Bioelectron , vol.32 , pp. 1-18
    • Johnson, B.N.1    Mutharasan, R.2
  • 80
    • 84859018954 scopus 로고    scopus 로고
    • Oriented conjugates of single-domain antibodies and quantum dots: Toward a new generation of ultrasmall diagnostic nanoprobes
    • Sukhanova A, Even-Desrumeaux K, Kisserli A, Tabary T, Reveil B, Millot JM, et al. Oriented conjugates of single-domain antibodies and quantum dots: toward a new generation of ultrasmall diagnostic nanoprobes. Nanomedicine 2012;8: 516-25.
    • (2012) Nanomedicine , vol.8 , pp. 516-525
    • Sukhanova, A.1    Even-Desrumeaux, K.2    Kisserli, A.3    Tabary, T.4    Reveil, B.5    Millot, J.M.6
  • 81
    • 68349117269 scopus 로고    scopus 로고
    • Single domain antibodies: Promising experimental and therapeutic tools in infection and immunity
    • Wesolowski J, Alzogaray V, Reyelt J, Unger M, Juarez K, Urrutia M, et al. Single domain antibodies: promising experimental and therapeutic tools in infection and immunity. Med Microbiol Immunol 2009;198:157-74.
    • (2009) Med Microbiol Immunol , vol.198 , pp. 157-174
    • Wesolowski, J.1    Alzogaray, V.2    Reyelt, J.3    Unger, M.4    Juarez, K.5    Urrutia, M.6
  • 82
    • 84862926222 scopus 로고    scopus 로고
    • Isolation of alpaca anti-hapten heavy chain single domain antibodies for development of sensitive immunoassay
    • Kim HJ, McCoy MR, Majkova Z, Dechant JE, Gee SJ, Tabares-da Rosa S, et al. Isolation of alpaca anti-hapten heavy chain single domain antibodies for development of sensitive immunoassay. Anal Chem 2012;84:1165-71.
    • (2012) Anal Chem , vol.84 , pp. 1165-1171
    • Kim, H.J.1    McCoy, M.R.2    Majkova, Z.3    Dechant, J.E.4    Gee, S.J.5    Tabares-Da Rosa, S.6
  • 83
    • 84875453903 scopus 로고    scopus 로고
    • Photonic crystal lab-on-a chip for detecting staphylococcal enterotoxin b at low attomolar concentration
    • Han JH, Kim HJ, Sudheendra L, Gee SJ, Hammock BD, Kennedy IM. Photonic crystal lab-on-a chip for detecting staphylococcal enterotoxin b at low attomolar concentration. Anal Chem 2013;85:3104-9.
    • (2013) Anal Chem , vol.85 , pp. 3104-3109
    • Han, J.H.1    Kim, H.J.2    Sudheendra, L.3    Gee, S.J.4    Hammock, B.D.5    Kennedy, I.M.6
  • 84
    • 35448959959 scopus 로고    scopus 로고
    • Detection and confirmation of staphylococcal enterotoxin b in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL
    • Maraldo D, Mutharasan R. Detection and confirmation of staphylococcal enterotoxin b in apple juice and milk using piezoelectric-excited millimeter-sized cantilever sensors at 2.5 fg/mL. Anal Chem 2007; 79:7636-43.
    • (2007) Anal Chem , vol.79 , pp. 7636-7643
    • Maraldo, D.1    Mutharasan, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.