-
1
-
-
66849142486
-
Aerosol antibiotics in cystic fibrosis
-
D.E. Geller Aerosol antibiotics in cystic fibrosis Respir. Care 54 2009 658 670
-
(2009)
Respir. Care
, vol.54
, pp. 658-670
-
-
Geller, D.E.1
-
2
-
-
0344513087
-
Pulmonary drug delivery. Part I: Physiological factors affecting therapeutic effectiveness of aerosolized medications
-
N.R. Labiris, and M.B. Dolovich Pulmonary drug delivery. Part I: physiological factors affecting therapeutic effectiveness of aerosolized medications Brit. J. Clin. Pharmacol. 56 2003 588 599
-
(2003)
Brit. J. Clin. Pharmacol.
, vol.56
, pp. 588-599
-
-
Labiris, N.R.1
Dolovich, M.B.2
-
3
-
-
0345534831
-
Dry Powder versus intravenous and nebulized gentamicin in cystic fibrosis and bronchiectasis
-
N. Crowther-Labiris, A. Holbrook, H. Chrystyn, S. MacLeod, and M. Newhouse Dry Powder versus intravenous and nebulized gentamicin in cystic fibrosis and bronchiectasis Am. J. Respir. Crit. Care Med. 160 1999 1711 1716
-
(1999)
Am. J. Respir. Crit. Care Med.
, vol.160
, pp. 1711-1716
-
-
Crowther-Labiris, N.1
Holbrook, A.2
Chrystyn, H.3
Macleod, S.4
Newhouse, M.5
-
4
-
-
0037346651
-
The inhalers of the future? A review of dry powder devices on the market today
-
I.J. Smith, and M. Parry-Billings The inhalers of the future? A review of dry powder devices on the market today Pulm. Pharmacol. Ther. 16 2003 79 95
-
(2003)
Pulm. Pharmacol. Ther.
, vol.16
, pp. 79-95
-
-
Smith, I.J.1
Parry-Billings, M.2
-
5
-
-
0029091872
-
A comparison of lung deposition patterns between different asthma inhalers
-
S.P. Newman A comparison of lung deposition patterns between different asthma inhalers J. Aerosol Med. 8 1995 21 27
-
(1995)
J. Aerosol Med.
, vol.8
, pp. 21-27
-
-
Newman, S.P.1
-
6
-
-
33645413962
-
High dose inhaled powder delivery: Challenges and techniques
-
R.N. Dalby, P.R. Byron, J. Peart, J.D. Suman, S.J. Farr, Davis Healthcare International Publishing (River Grove, IL, USA) Palm Desert, CA, USA
-
J. Weers, A. Clark, and P. Challoner High dose inhaled powder delivery: challenges and techniques R.N. Dalby, P.R. Byron, J. Peart, J.D. Suman, S.J. Farr, Respiratory Drug Delivery IX 2004 Davis Healthcare International Publishing (River Grove, IL, USA) Palm Desert, CA, USA 281 288
-
(2004)
Respiratory Drug Delivery IX
, pp. 281-288
-
-
Weers, J.1
Clark, A.2
Challoner, P.3
-
7
-
-
66849121732
-
New aerosol delivery devices for cystic fibrosis
-
K.C. Kesser, and D.E. Geller New aerosol delivery devices for cystic fibrosis Respir. Care 54 2009 754 768
-
(2009)
Respir. Care
, vol.54
, pp. 754-768
-
-
Kesser, K.C.1
Geller, D.E.2
-
8
-
-
0029757981
-
Efficient delivery to the lungs of flunisolide aerosol from a new portable hand-held multidose nebulizer
-
S.P. Newman, K.P. Steed, S.J. Reader, G. Hooper, and B. Zierenberg Efficient delivery to the lungs of flunisolide aerosol from a new portable hand-held multidose nebulizer J. Pharm. Sci. 85 1996 960 964
-
(1996)
J. Pharm. Sci.
, vol.85
, pp. 960-964
-
-
Newman, S.P.1
Steed, K.P.2
Reader, S.J.3
Hooper, G.4
Zierenberg, B.5
-
9
-
-
79952763932
-
Aerosol drug delivery: Developments in device design and clinical use
-
M.B. Dolovich, and R. Dhand Aerosol drug delivery: developments in device design and clinical use Lancet 377 2011 1032 1045
-
(2011)
Lancet
, vol.377
, pp. 1032-1045
-
-
Dolovich, M.B.1
Dhand, R.2
-
11
-
-
0015133119
-
Dry powder aerosols I: A new powder inhalation device
-
J.H. Bell, P.S. Hartley, and J.S.G. Cox Dry powder aerosols I: a new powder inhalation device J. Pharm. Sci. 60 1971 1559 1564
-
(1971)
J. Pharm. Sci.
, vol.60
, pp. 1559-1564
-
-
Bell, J.H.1
Hartley, P.S.2
Cox, J.S.G.3
-
12
-
-
0016384135
-
Evaluation of an antiasthmatic agent cromolyn sodium (aarane, intal)
-
M.M. Dykes Evaluation of an antiasthmatic agent cromolyn sodium (aarane, intal) JAMA - J. Am. Med. Assoc. 227 1974 1061 1062
-
(1974)
JAMA - J. Am. Med. Assoc.
, vol.227
, pp. 1061-1062
-
-
Dykes, M.M.1
-
13
-
-
0028031785
-
Effect of different modes of inhalation on drug delivery from a dry powder inhaler
-
S.P. Newman, A. Hollingworth, and A.R. Clark Effect of different modes of inhalation on drug delivery from a dry powder inhaler Int. J. Pharm. 102 1994 127 132
-
(1994)
Int. J. Pharm.
, vol.102
, pp. 127-132
-
-
Newman, S.P.1
Hollingworth, A.2
Clark, A.R.3
-
14
-
-
0342940773
-
In vitro evaluation of dry powder inhalers I: Drug deposition of commonly used devices
-
H. Steckel, and B.W. Müller In vitro evaluation of dry powder inhalers I: drug deposition of commonly used devices Int. J. Pharm. 154 1997 19 29
-
(1997)
Int. J. Pharm.
, vol.154
, pp. 19-29
-
-
Steckel, H.1
Müller, B.W.2
-
15
-
-
33644617924
-
Dry powder inhaler formulation
-
M.J. Telko, and A.J. Hickey Dry powder inhaler formulation Respir. Care 50 2005 1209 1227
-
(2005)
Respir. Care
, vol.50
, pp. 1209-1227
-
-
Telko, M.J.1
Hickey, A.J.2
-
16
-
-
84862677852
-
Particles and powders: Tools of innovation for non-invasive drug administration
-
10.1016/j.jconrel.2012.1002.1028
-
F. Buttini, P. Colombo, A. Rossi, F. Sonvico, and G. Colombo Particles and powders: tools of innovation for non-invasive drug administration J. Controlled Release 2012 10.1016/j.jconrel.2012.1002.1028
-
(2012)
J. Controlled Release
-
-
Buttini, F.1
Colombo, P.2
Rossi, A.3
Sonvico, F.4
Colombo, G.5
-
17
-
-
0027957592
-
Drug delivery to the respiratory tract using dry powder inhalers
-
M.P. Timsina, G.P. Martin, C. Marriott, D. Ganderton, and M. Yianneskis Drug delivery to the respiratory tract using dry powder inhalers Int. J. Pharm. 101 1994 1 13
-
(1994)
Int. J. Pharm.
, vol.101
, pp. 1-13
-
-
Timsina, M.P.1
Martin, G.P.2
Marriott, C.3
Ganderton, D.4
Yianneskis, M.5
-
20
-
-
52149086776
-
Advancements in dry powder delivery to the lung
-
Y.-J. Son, and J.T. McConville Advancements in dry powder delivery to the lung Drug Dev. Ind. Pharm. 34 2008 948 959
-
(2008)
Drug Dev. Ind. Pharm.
, vol.34
, pp. 948-959
-
-
Son, Y.-J.1
McConville, J.T.2
-
21
-
-
0036591409
-
Delivery of formoterol from a novel multi-dose inhaler AirmaxTM
-
X.M. Zeng, S. Jones, D. O'Leary, M. Phelan, and J. Colledge Delivery of formoterol from a novel multi-dose inhaler AirmaxTM Respir. Med. 96 2002 397 403
-
(2002)
Respir. Med.
, vol.96
, pp. 397-403
-
-
Zeng, X.M.1
Jones, S.2
O'Leary, D.3
Phelan, M.4
Colledge, J.5
-
22
-
-
0036591411
-
Delivery of salbutamol and of budesonide from a novel multi-dose inhaler AirmaxTM
-
X.M. Zeng, D. O'Leary, M. Phelan, S. Jones, and J. Colledge Delivery of salbutamol and of budesonide from a novel multi-dose inhaler AirmaxTM Respir. Med. 96 2002 404 411
-
(2002)
Respir. Med.
, vol.96
, pp. 404-411
-
-
Zeng, X.M.1
O'Leary, D.2
Phelan, M.3
Jones, S.4
Colledge, J.5
-
23
-
-
0033911733
-
Scintigraphic comparison of budesonide deposition from two dry powder inhalers
-
S. Newman, G. Pitcairn, P. Hirst, R. Bacon, E. O'Keefe, M. Reiners, and R. Hermann Scintigraphic comparison of budesonide deposition from two dry powder inhalers Eur. Respir. J. 16 2000 178 183
-
(2000)
Eur. Respir. J.
, vol.16
, pp. 178-183
-
-
Newman, S.1
Pitcairn, G.2
Hirst, P.3
Bacon, R.4
O'Keefe, E.5
Reiners, M.6
Hermann, R.7
-
24
-
-
0033932666
-
Pulmonary drug delivery from the Taifun dry powder inhaler is relatively independent of the patient's inspiratory effort
-
G.R. Pitcairn, T. Lankinen, O.-P. Seppälä, and S.P. Newman Pulmonary drug delivery from the Taifun dry powder inhaler is relatively independent of the patient's inspiratory effort J. Aerosol Med. 13 2000 97 104
-
(2000)
J. Aerosol Med.
, vol.13
, pp. 97-104
-
-
Pitcairn, G.R.1
Lankinen, T.2
Seppälä, O.-P.3
Newman, S.P.4
-
25
-
-
84896710944
-
-
PH&T. (accessed 05.07.12)
-
PH&T. < http://www.phtpharma.com/images/volantino-turbospin.pdf > (accessed 05.07.12).
-
-
-
-
26
-
-
84896714865
-
-
United States Patent 4,069,819, Societa Farmaceutici S.p.A. (Milan, Italy), United States
-
L. Valentini, M. Maiorano, Inhalation Device, United States Patent 4,069,819, Societa Farmaceutici S.p.A. (Milan, Italy), United States, 1978.
-
(1978)
Inhalation Device
-
-
Valentini, L.1
Maiorano, M.2
-
27
-
-
31144432665
-
EXUBERA®: Pharmaceutical development of a novel product for pulmonary delivery of insulin
-
S. White, D.B. Bennett, S. Cheu, P.W. Conley, D.B. Guzek, S. Gray, J. Howard, R. Malcolmson, J.M. Parker, P. Roberts, N. Sadrzadeh, J.D. Schumacher, S. Seshadri, G.W. Sluggett, C.L. Stevenson, and N.J. Harper EXUBERA®: pharmaceutical development of a novel product for pulmonary delivery of insulin Diabetes Technol. Ther. 7 2005 896 906
-
(2005)
Diabetes Technol. Ther.
, vol.7
, pp. 896-906
-
-
White, S.1
Bennett, D.B.2
Cheu, S.3
Conley, P.W.4
Guzek, D.B.5
Gray, S.6
Howard, J.7
Malcolmson, R.8
Parker, J.M.9
Roberts, P.10
Sadrzadeh, N.11
Schumacher, J.D.12
Seshadri, S.13
Sluggett, G.W.14
Stevenson, C.L.15
Harper, N.J.16
-
28
-
-
1542498664
-
Alternative routes of insulin delivery
-
D.R. Owens, B. Zinman, and G. Bolli Alternative routes of insulin delivery Diabetic Med. 20 2003 886 898
-
(2003)
Diabetic Med.
, vol.20
, pp. 886-898
-
-
Owens, D.R.1
Zinman, B.2
Bolli, G.3
-
29
-
-
2442674988
-
Active and intelligent inhaler device development
-
M. Tobyn, J.N. Staniforth, D. Morton, Q. Harmer, and M.E. Newton Active and intelligent inhaler device development Int. J. Pharm. 277 2004 31 37
-
(2004)
Int. J. Pharm.
, vol.277
, pp. 31-37
-
-
Tobyn, M.1
Staniforth, J.N.2
Morton, D.3
Harmer, Q.4
Newton, M.E.5
-
30
-
-
33646888854
-
Design and in vitro performance testing of multiple air classifier technology in a new disposable inhaler concept (Twincer®) for high powder doses
-
A.H. de Boer, P. Hagedoorn, E.M. Westerman, P.P.H. Le Brun, H.G.M. Heijerman, and H.W. Frijlink Design and in vitro performance testing of multiple air classifier technology in a new disposable inhaler concept (Twincer®) for high powder doses Eur. J. Pharm. Sci. 28 2006 171 178
-
(2006)
Eur. J. Pharm. Sci.
, vol.28
, pp. 171-178
-
-
De Boer, A.H.1
Hagedoorn, P.2
Westerman, E.M.3
Le Brun, P.P.H.4
Heijerman, H.G.M.5
Frijlink, H.W.6
-
31
-
-
0347572591
-
The use of a novel handheld device to deliver high respirable fractions of high-dose dry powder active agents to the lung
-
P.M. Young, J. Thompson, R. Price, D. Woodcock, and K. Davies The use of a novel handheld device to deliver high respirable fractions of high-dose dry powder active agents to the lung J. Aerosol Med. 16 2003 192
-
(2003)
J. Aerosol Med.
, vol.16
, pp. 192
-
-
Young, P.M.1
Thompson, J.2
Price, R.3
Woodcock, D.4
Davies, K.5
-
32
-
-
3242685863
-
The development of a novel high-dose pressurized aerosol dry-powder device (PADD) for the delivery of pumactant for inhalation therapy
-
P.M. Young, J. Thompson, D. Woodcock, M. Aydin, and R. Price The development of a novel high-dose pressurized aerosol dry-powder device (PADD) for the delivery of pumactant for inhalation therapy J. Aerosol Med. 17 2004 123 128
-
(2004)
J. Aerosol Med.
, vol.17
, pp. 123-128
-
-
Young, P.M.1
Thompson, J.2
Woodcock, D.3
Aydin, M.4
Price, R.5
-
33
-
-
84896729248
-
-
RDD Europe, Berlin
-
R. Winkler, H. Wachtel, P. Langguth, Dose Range of a Propellant Driven High-Dose Dry Powder Inhaler, RDD Europe, Berlin, 2013, pp. 251-255.
-
(2013)
Dose Range of A Propellant Driven High-Dose Dry Powder Inhaler
, pp. 251-255
-
-
Winkler, R.1
Wachtel, H.2
Langguth, P.3
-
34
-
-
84873724393
-
Device engineering insights into TOBI Podhaler: A development case study of high efficient powder delivery to cystic fibrosis patients
-
R.N. Dalby, P.R. Byron, J. Peart, J.D. Suman, P.M. Young, Davis Healthcare International Publishing (River Grove, IL, USA) Berlin, Germany
-
D.S. Maltz, and S.J. Paboojian Device engineering insights into TOBI Podhaler: a development case study of high efficient powder delivery to cystic fibrosis patients R.N. Dalby, P.R. Byron, J. Peart, J.D. Suman, P.M. Young, Respiratory Drug Delivery Europe 2011, Davis Healthcare International Publishing (River Grove) 2011 Davis Healthcare International Publishing (River Grove, IL, USA) Berlin, Germany 55 65
-
(2011)
Respiratory Drug Delivery Europe 2011, Davis Healthcare International Publishing (River Grove)
, pp. 55-65
-
-
Maltz, D.S.1
Paboojian, S.J.2
-
35
-
-
84896730262
-
Dose emission characteristics of placebo PulmoSphere((R)) particles are unaffected by a subject's inhalation maneuver
-
J. Weers, K. Ung, J. Le, N. Rao, B. Ament, G. Axford, D. Maltz, and L. Chan Dose emission characteristics of placebo PulmoSphere((R)) particles are unaffected by a subject's inhalation maneuver J. Aerosol. Med. Pulm. Drug Delivery 2012
-
(2012)
J. Aerosol. Med. Pulm. Drug Delivery
-
-
Weers, J.1
Ung, K.2
Le, J.3
Rao, N.4
Ament, B.5
Axford, G.6
Maltz, D.7
Chan, L.8
-
36
-
-
84858624234
-
Lactose characteristics and the generation of the aerosol
-
G. Pilcer, N. Wauthoz, and K. Amighi Lactose characteristics and the generation of the aerosol Adv. Drug Delivery Rev. 64 2012 233 256
-
(2012)
Adv. Drug Delivery Rev.
, vol.64
, pp. 233-256
-
-
Pilcer, G.1
Wauthoz, N.2
Amighi, K.3
-
37
-
-
0036797972
-
Characterization of a surface modified dry powder inhalation carrier prepared by "particle smoothing"
-
P.M. Young, D. Cocconi, P. Colombo, R. Bettini, R. Price, D.F. Steele, and M.J. Tobyn Characterization of a surface modified dry powder inhalation carrier prepared by "particle smoothing" J. Pharm. Pharmacol. 54 2002 1339 1344
-
(2002)
J. Pharm. Pharmacol.
, vol.54
, pp. 1339-1344
-
-
Young, P.M.1
Cocconi, D.2
Colombo, P.3
Bettini, R.4
Price, R.5
Steele, D.F.6
Tobyn, M.J.7
-
38
-
-
0342437435
-
In vitro evaluation of dry powder inhalers II: Influence of carrier particle size and concentration on in vitro deposition
-
H. Steckel, and B.W. Müller In vitro evaluation of dry powder inhalers II: influence of carrier particle size and concentration on in vitro deposition Int. J. Pharm. 154 1997 31 37
-
(1997)
Int. J. Pharm.
, vol.154
, pp. 31-37
-
-
Steckel, H.1
Müller, B.W.2
-
39
-
-
0031787402
-
The role of fine particle lactose on the dispersion and deaggregation of salbutamol sulphate in an air stream in vitro
-
X.M. Zeng, G.P. Martin, S.-K. Tee, and C. Marriott The role of fine particle lactose on the dispersion and deaggregation of salbutamol sulphate in an air stream in vitro Int. J. Pharm. 176 1998 99 110
-
(1998)
Int. J. Pharm.
, vol.176
, pp. 99-110
-
-
Zeng, X.M.1
Martin, G.P.2
Tee, S.-K.3
Marriott, C.4
-
41
-
-
1842739246
-
The influence of carrier roughness on adhesion, content uniformity and the in vitro deposition of terbutaline sulphate from dry powder inhalers
-
M.-P. Flament, P. Leterme, and A. Gayot The influence of carrier roughness on adhesion, content uniformity and the in vitro deposition of terbutaline sulphate from dry powder inhalers Int. J. Pharm. 275 2004 201 209
-
(2004)
Int. J. Pharm.
, vol.275
, pp. 201-209
-
-
Flament, M.-P.1
Leterme, P.2
Gayot, A.3
-
43
-
-
33746916510
-
The influence of fine excipient particles on the performance of carrier-based dry powder inhalation formulations
-
M. Jones, and R. Price The influence of fine excipient particles on the performance of carrier-based dry powder inhalation formulations Pharm. Res. 23 2006 1665 1674
-
(2006)
Pharm. Res.
, vol.23
, pp. 1665-1674
-
-
Jones, M.1
Price, R.2
-
44
-
-
0031925636
-
Protein deposition from dry powder inhalers: Fine particle multiplets as performance modifiers
-
P. Lucas, K. Anderson, and J.N. Staniforth Protein deposition from dry powder inhalers: fine particle multiplets as performance modifiers Pharm. Res. 15 1998 562 569
-
(1998)
Pharm. Res.
, vol.15
, pp. 562-569
-
-
Lucas, P.1
Anderson, K.2
Staniforth, J.N.3
-
45
-
-
0024062977
-
Turbuhaler: A new powder inhaler for administration of drugs to the airways
-
K. Wetterlin Turbuhaler: a new powder inhaler for administration of drugs to the airways Pharm. Res. 5 1988 506 508
-
(1988)
Pharm. Res.
, vol.5
, pp. 506-508
-
-
Wetterlin, K.1
-
46
-
-
9644279431
-
Formulation development of inhalation powders for FK888 using the E-haler® to improve the inhalation performance at a high dose, and its absorption in healthy volunteers
-
T. Nakate, H. Yoshida, A. Ohike, Y. Tokunaga, R. Ibuki, and Y. Kawashima Formulation development of inhalation powders for FK888 using the E-haler® to improve the inhalation performance at a high dose, and its absorption in healthy volunteers Eur. J. Pharm. Biopharm. 59 2005 25 33
-
(2005)
Eur. J. Pharm. Biopharm.
, vol.59
, pp. 25-33
-
-
Nakate, T.1
Yoshida, H.2
Ohike, A.3
Tokunaga, Y.4
Ibuki, R.5
Kawashima, Y.6
-
47
-
-
77952744763
-
Formulation strategy and use of excipients in pulmonary drug delivery
-
G. Pilcer, and K. Amighi Formulation strategy and use of excipients in pulmonary drug delivery Int. J. Pharm. 392 2010 1 19
-
(2010)
Int. J. Pharm.
, vol.392
, pp. 1-19
-
-
Pilcer, G.1
Amighi, K.2
-
48
-
-
0037223728
-
Micronization of anti-inflammatory drugs for pulmonary delivery by a controlled crystallization process
-
N. Rasenack, H. Steckel, and B.W. Müller Micronization of anti-inflammatory drugs for pulmonary delivery by a controlled crystallization process J. Pharm. Sci. 92 2003 35 44
-
(2003)
J. Pharm. Sci.
, vol.92
, pp. 35-44
-
-
Rasenack, N.1
Steckel, H.2
Müller, B.W.3
-
49
-
-
52049118554
-
What is the role of particle morphology in pharmaceutical powder aerosols?
-
H.-K. Chan What is the role of particle morphology in pharmaceutical powder aerosols? Expert Opin. Drug Delivery 5 2008 909 914
-
(2008)
Expert Opin. Drug Delivery
, vol.5
, pp. 909-914
-
-
Chan, H.-K.1
-
50
-
-
0036805725
-
Improved inhalation behavior of steroid KSR-592 in vitro with Jethaler® by polymorphic transformation to needle-like crystals (β-form)
-
K. Ikegami, Y. Kawashima, H. Takeuchi, H. Yamamoto, N. Isshiki, D.-I. Momose, and K. Ouchi Improved inhalation behavior of steroid KSR-592 in vitro with Jethaler® by polymorphic transformation to needle-like crystals (β-form) Pharm. Res. 19 2002 1439 1445
-
(2002)
Pharm. Res.
, vol.19
, pp. 1439-1445
-
-
Ikegami, K.1
Kawashima, Y.2
Takeuchi, H.3
Yamamoto, H.4
Isshiki, N.5
Momose, D.-I.6
Ouchi, K.7
-
52
-
-
0034858772
-
Characterization of two polymorphs of salmeterol xinafoate crystallized from supercritical fluids
-
H.H.Y. Tong, B. Yu Shekunov, P. York, and A.H.L. Chow Characterization of two polymorphs of salmeterol xinafoate crystallized from supercritical fluids Pharm. Res. 18 2001 852 858
-
(2001)
Pharm. Res.
, vol.18
, pp. 852-858
-
-
Tong, H.H.Y.1
Yu Shekunov, B.2
York, P.3
Chow, A.H.L.4
-
53
-
-
36649033018
-
Conformational analysis of protein secondary structure during spray-drying of antibody/mannitol formulations
-
S. Schüle, W. Frieß, K. Bechtold-Peters, and P. Garidel Conformational analysis of protein secondary structure during spray-drying of antibody/mannitol formulations Eur. J. Pharm. Biopharm. 65 2007 1 9
-
(2007)
Eur. J. Pharm. Biopharm.
, vol.65
, pp. 1-9
-
-
Schüle, S.1
Frieß, W.2
Bechtold-Peters, K.3
Garidel, P.4
-
54
-
-
74049124897
-
Spray drying technique. I: Hardware and process parameters
-
K. Cal, and K. Sollohub Spray drying technique. I: hardware and process parameters J. Pharm. Sci. 99 2010 575 586
-
(2010)
J. Pharm. Sci.
, vol.99
, pp. 575-586
-
-
Cal, K.1
Sollohub, K.2
-
55
-
-
42049094490
-
Pharmaceutical particle engineering via spray drying
-
R. Vehring Pharmaceutical particle engineering via spray drying Pharm. Res. 25 2008 999 1022
-
(2008)
Pharm. Res.
, vol.25
, pp. 999-1022
-
-
Vehring, R.1
-
56
-
-
0034750024
-
Use of solid corrugated particles to enhance powder aerosol performance
-
N.Y.K. Chew, and H.-K. Chan Use of solid corrugated particles to enhance powder aerosol performance Pharm. Res. 18 2001 1570 1577
-
(2001)
Pharm. Res.
, vol.18
, pp. 1570-1577
-
-
Chew, N.Y.K.1
Chan, H.-K.2
-
57
-
-
17644394959
-
How much particle surface corrugation is sufficient to improve aerosol performance of powders?
-
N.Y.K. Chew, P. Tang, H.-K. Chan, and J.A. Raper How much particle surface corrugation is sufficient to improve aerosol performance of powders? Pharm. Res. 22 2005 148 152
-
(2005)
Pharm. Res.
, vol.22
, pp. 148-152
-
-
Chew, N.Y.K.1
Tang, P.2
Chan, H.-K.3
Raper, J.A.4
-
59
-
-
73949099876
-
Force control and powder dispersibility of spray dried particles for inhalation
-
C. Weiler, M. Egen, M. Trunk, and P. Langguth Force control and powder dispersibility of spray dried particles for inhalation J. Pharm. Sci. 99 2010 303 316
-
(2010)
J. Pharm. Sci.
, vol.99
, pp. 303-316
-
-
Weiler, C.1
Egen, M.2
Trunk, M.3
Langguth, P.4
-
60
-
-
84857784969
-
Dry powder inhalers of gentamicin and leucine: Formulation parameters, aerosol performance and in vitro toxicity on CuFi1 cells
-
R.P. Aquino, L. Prota, G. Auriemma, A. Santoro, T. Mencherini, G. Colombo, and P. Russo Dry powder inhalers of gentamicin and leucine: formulation parameters, aerosol performance and in vitro toxicity on CuFi1 cells Int. J. Pharm. 426 2012 100 107
-
(2012)
Int. J. Pharm.
, vol.426
, pp. 100-107
-
-
Aquino, R.P.1
Prota, L.2
Auriemma, G.3
Santoro, A.4
Mencherini, T.5
Colombo, G.6
Russo, P.7
-
61
-
-
38349089705
-
Trileucine improves aerosol performance and stability of spray-dried powders for inhalation
-
D. Lechuga-Ballesteros, C. Charan, C.L.M. Stults, C.L. Stevenson, D.P. Miller, R. Vehring, V. Tep, and M.-C. Kuo Trileucine improves aerosol performance and stability of spray-dried powders for inhalation J. Pharm. Sci. 97 2008 287 302
-
(2008)
J. Pharm. Sci.
, vol.97
, pp. 287-302
-
-
Lechuga-Ballesteros, D.1
Charan, C.2
Stults, C.L.M.3
Stevenson, C.L.4
Miller, D.P.5
Vehring, R.6
Tep, V.7
Kuo, M.-C.8
-
62
-
-
84896702333
-
-
Boehringer Ingelheim Pharma GmbH & Co. KG (Binger Strasse 173, 55216 Ingelheim, DE)
-
K. Bechtold-Peters, W. Friess, S. Schuele, S. Bassarab, P. Garidel, T. Schultz-Fademrecht, Spray-Dried Amorphous Powder with a low Residual Moisture and Excellent Storage Stability, Boehringer Ingelheim Pharma GmbH & Co. KG (Binger Strasse 173, 55216 Ingelheim, DE), 2008.
-
(2008)
Spray-Dried Amorphous Powder with A Low Residual Moisture and Excellent Storage Stability
-
-
Bechtold-Peters, K.1
Friess, W.2
Schuele, S.3
Bassarab, S.4
Garidel, P.5
Schultz-Fademrecht, T.6
-
63
-
-
0032734092
-
Formulation and physical characterization of large porous particles for inhalation
-
R. Vanbever, J.D. Mintzes, J. Wang, J. Nice, D. Chen, R. Batycky, R. Langer, and D.A. Edwards Formulation and physical characterization of large porous particles for inhalation Pharm. Res. 16 1999 1735 1742
-
(1999)
Pharm. Res.
, vol.16
, pp. 1735-1742
-
-
Vanbever, R.1
Mintzes, J.D.2
Wang, J.3
Nice, J.4
Chen, D.5
Batycky, R.6
Langer, R.7
Edwards, D.A.8
-
64
-
-
79961039597
-
Development of an inhaled dry-powder formulation of tobramycin using PulmoSphere™ technology
-
D.E. Geller, J. Weers, and S. Heuerding Development of an inhaled dry-powder formulation of tobramycin using PulmoSphere™ technology J. Aerosol Med. Pulm. Drug Delivery 24 2011 175 182
-
(2011)
J. Aerosol Med. Pulm. Drug Delivery
, vol.24
, pp. 175-182
-
-
Geller, D.E.1
Weers, J.2
Heuerding, S.3
-
65
-
-
0006189298
-
Dispersible powders for inhalation applications
-
J. Weers Dispersible powders for inhalation applications Innov. Pharm. Tech. 7 2001 111 116
-
(2001)
Innov. Pharm. Tech.
, vol.7
, pp. 111-116
-
-
Weers, J.1
-
66
-
-
34247193128
-
Novel tobramycin inhalation powder in cystic fibrosis subjects: Pharmacokinetics and safety
-
D.E. Geller, M.W. Konstan, J. Smith, S.B. Noonberg, and C. Conrad Novel tobramycin inhalation powder in cystic fibrosis subjects: pharmacokinetics and safety Pediatr. Pulm. 42 2007 307 313
-
(2007)
Pediatr. Pulm.
, vol.42
, pp. 307-313
-
-
Geller, D.E.1
Konstan, M.W.2
Smith, J.3
Noonberg, S.B.4
Conrad, C.5
-
67
-
-
0034495318
-
Protein spray-freeze drying. Effect of atomization conditions on particle size and stability
-
H.R. Costantino, L. Firouzabadian, K. Hogeland, C. Wu, C. Beganski, K.G. Carrasquillo, M. Córdova, K. Griebenow, S.E. Zale, and M.A. Tracy Protein spray-freeze drying. Effect of atomization conditions on particle size and stability Pharm. Res. 17 2000 1374 1382
-
(2000)
Pharm. Res.
, vol.17
, pp. 1374-1382
-
-
Costantino, H.R.1
Firouzabadian, L.2
Hogeland, K.3
Wu, C.4
Beganski, C.5
Carrasquillo, K.G.6
Córdova, M.7
Griebenow, K.8
Zale, S.E.9
Tracy, M.A.10
-
68
-
-
0033043629
-
Protein inhalation powders: Spray drying vs spray freeze drying
-
Y.-F. Maa, P.-A. Nguyen, T. Sweeney, S.J. Shire, and C.C. Hsu Protein inhalation powders: spray drying vs spray freeze drying Pharm. Res. 16 1999 249 254
-
(1999)
Pharm. Res.
, vol.16
, pp. 249-254
-
-
Maa, Y.-F.1
Nguyen, P.-A.2
Sweeney, T.3
Shire, S.J.4
Hsu, C.C.5
-
69
-
-
0036170355
-
Protein spray freeze drying. 2. Effect of formulation variables on particle size and stability
-
H.R. Costantino, L. Firouzabadian, C. Wu, K.G. Carrasquillo, K. Griebenow, S.E. Zale, and M.A. Tracy Protein spray freeze drying. 2. Effect of formulation variables on particle size and stability J. Pharm. Sci. 91 2002 388 395
-
(2002)
J. Pharm. Sci.
, vol.91
, pp. 388-395
-
-
Costantino, H.R.1
Firouzabadian, L.2
Wu, C.3
Carrasquillo, K.G.4
Griebenow, K.5
Zale, S.E.6
Tracy, M.A.7
-
70
-
-
28244484920
-
Pulmonary insulin delivery by means of the Technosphere™ drug carrier mechanism
-
A. Pfützner, and T. Forst Pulmonary insulin delivery by means of the Technosphere™ drug carrier mechanism Expert Opin. Drug Delivery 2 2005 1097 1106
-
(2005)
Expert Opin. Drug Delivery
, vol.2
, pp. 1097-1106
-
-
Pfützner, A.1
Forst, T.2
-
71
-
-
0041928149
-
Technopshere/PTH(1-34) - A new approach for effective pulmonary delivery of parathyroid hormone(1-34)
-
A. Pfützner, F. Flacke, R. Pohl, D. Linkie, M. Engelbach, R. Woods, T. Forst, J. Beyer, and S.S. Steiner Technopshere/PTH(1-34) - a new approach for effective pulmonary delivery of parathyroid hormone(1-34) Horm. Metab. Res. 35 2003 319 323
-
(2003)
Horm. Metab. Res.
, vol.35
, pp. 319-323
-
-
Pfützner, A.1
Flacke, F.2
Pohl, R.3
Linkie, D.4
Engelbach, M.5
Woods, R.6
Forst, T.7
Beyer, J.8
Steiner, S.S.9
-
72
-
-
0036025088
-
Technosphere/insulin - A new approach for effective delivery of human insulin via the pulmonary route
-
A. Pfützner, A.E. Mann, and S.S. Steiner Technosphere/insulin - a new approach for effective delivery of human insulin via the pulmonary route Diabetes Technol. Ther. 4 2002 589 594
-
(2002)
Diabetes Technol. Ther.
, vol.4
, pp. 589-594
-
-
Pfützner, A.1
Mann, A.E.2
Steiner, S.S.3
-
74
-
-
0038826781
-
Inhalation of a dry powder tobramycin pulmosphere formulation in healthy volunteers
-
M.T. Newhouse, P.H. Hirst, S.P. Duddu, Y.H. Walter, T.E. Tarara, A.R. Clark, and J.G. Weers Inhalation of a dry powder tobramycin pulmosphere formulation in healthy volunteers Chest 124 2003 360 366
-
(2003)
Chest
, vol.124
, pp. 360-366
-
-
Newhouse, M.T.1
Hirst, P.H.2
Duddu, S.P.3
Walter, Y.H.4
Tarara, T.E.5
Clark, A.R.6
Weers, J.G.7
-
75
-
-
84885855014
-
-
WC500123690, European Medicines Agency
-
Colobreath Product Information, WC500123690, European Medicines Agency, 2012.
-
(2012)
Colobreath Product Information
-
-
-
76
-
-
84896724896
-
Tief in den Lungen
-
Bayer AG, Leverkusen, Germany
-
Tief in den Lungen, in: Bayer Research 21, Bayer AG, Leverkusen, Germany, 2011.
-
(2011)
Bayer Research 21
-
-
-
77
-
-
84896728532
-
Ciprofloxacin PulmoSpere inhalation powder: A healthy volunteer study
-
Toronto, Canada
-
H. Stass, S. Baumann-Noss, H. Delesen, J. Nagelschmitz, S. Willmann, A. Edginton, Ciprofloxacin PulmoSpere inhalation powder: a healthy volunteer study, in: American Thoracic Society International Conference, Toronto, Canada, 2008.
-
(2008)
American Thoracic Society International Conference
-
-
Stass, H.1
Baumann-Noss, S.2
Delesen, H.3
Nagelschmitz, J.4
Willmann, S.5
Edginton, A.6
-
79
-
-
84896697795
-
-
Savara Pharmaceuticals USA. News Section of Web Site: (accessed 20.06.12)
-
Savara Pharmaceuticals, USA. News Section of Web Site: < http://www.savarapharma.com/news.html > (accessed 20.06.12).
-
-
-
-
80
-
-
0030783036
-
A new method for bronchial-provocation testing in asthmatic subjects using a dry powder of mannitol
-
S.D. Anderson, J. Brannan, J. Spring, N. Spalding, L.T. Rodwell, K. Cahn, I. Gonda, A. Walsh, and A.R. Clark A new method for bronchial-provocation testing in asthmatic subjects using a dry powder of mannitol Am. J. Respir. Crit. Care Med. 156 1997 758 765
-
(1997)
Am. J. Respir. Crit. Care Med.
, vol.156
, pp. 758-765
-
-
Anderson, S.D.1
Brannan, J.2
Spring, J.3
Spalding, N.4
Rodwell, L.T.5
Cahn, K.6
Gonda, I.7
Walsh, A.8
Clark, A.R.9
-
82
-
-
84862884661
-
Ergänzender Baustein zur Therapie der Mukoviszidose
-
P. Jungmayr Ergänzender Baustein zur Therapie der Mukoviszidose Deut. Apotheker Zeitung 152 2012 38 40
-
(2012)
Deut. Apotheker Zeitung
, vol.152
, pp. 38-40
-
-
Jungmayr, P.1
-
83
-
-
44649166466
-
*
-
* Chest 133 2008 1388 1396
-
(2008)
Chest
, vol.133
, pp. 1388-1396
-
-
Jaques, A.1
Daviskas, E.2
Turton, J.A.3
McKay, K.4
Cooper, P.5
Stirling, R.G.6
Robertson, C.F.7
Bye, P.T.P.8
Lesouëf, P.N.9
Shadbolt, B.10
Anderson, S.D.11
Charlton, B.12
-
84
-
-
44649138531
-
Inhalable large porous microspheres of low molecular weight heparin: In vitro and in vivo evaluation
-
A. Rawat, Q.H. Majumder, and F. Ahsan Inhalable large porous microspheres of low molecular weight heparin: in vitro and in vivo evaluation J. Controlled Release 128 2008 224 232
-
(2008)
J. Controlled Release
, vol.128
, pp. 224-232
-
-
Rawat, A.1
Majumder, Q.H.2
Ahsan, F.3
-
85
-
-
0038652086
-
Inhaled synthetic surfactant abolishes the early allergen-induced response in asthma
-
K.S. Babu, D.A. Woodcock, S.E. Smith, J.N. Staniforth, S.T. Holgate, and J.H. Conway Inhaled synthetic surfactant abolishes the early allergen-induced response in asthma Eur. Respir. J. 21 2003 1046 1049
-
(2003)
Eur. Respir. J.
, vol.21
, pp. 1046-1049
-
-
Babu, K.S.1
Woodcock, D.A.2
Smith, S.E.3
Staniforth, J.N.4
Holgate, S.T.5
Conway, J.H.6
-
86
-
-
0037441782
-
Mannitol as a challenge test to identify exercise-induced bronchoconstriction in elite athletes
-
K. Holzer, S.D. Anderson, H.-K. Chan, and J. Douglass Mannitol as a challenge test to identify exercise-induced bronchoconstriction in elite athletes Am. J. Respir. Crit. Care Med. 167 2003 534 537
-
(2003)
Am. J. Respir. Crit. Care Med.
, vol.167
, pp. 534-537
-
-
Holzer, K.1
Anderson, S.D.2
Chan, H.-K.3
Douglass, J.4
-
87
-
-
79951840468
-
Tobramycin inhalation powder for P. Aeruginosa infection in cystic fibrosis: The EVOLVE trial
-
M.W. Konstan, D.E. Geller, P. Minić, F. Brockhaus, J. Zhang, and G. Angyalosi Tobramycin inhalation powder for P. aeruginosa infection in cystic fibrosis: the EVOLVE trial Pediatr. Pulm. 46 2011 230 238
-
(2011)
Pediatr. Pulm.
, vol.46
, pp. 230-238
-
-
Konstan, M.W.1
Geller, D.E.2
Minić, P.3
Brockhaus, F.4
Zhang, J.5
Angyalosi, G.6
-
88
-
-
78651412529
-
Safety, efficacy and convenience of tobramycin inhalation powder in cystic fibrosis patients: The EAGER trial
-
M.W. Konstan, P.A. Flume, M. Kappler, R. Chiron, M. Higgins, F. Brockhaus, J. Zhang, G. Angyalosi, E. He, and D.E. Geller Safety, efficacy and convenience of tobramycin inhalation powder in cystic fibrosis patients: the EAGER trial J. Cyst. Fibros. 10 2011 54 61
-
(2011)
J. Cyst. Fibros.
, vol.10
, pp. 54-61
-
-
Konstan, M.W.1
Flume, P.A.2
Kappler, M.3
Chiron, R.4
Higgins, M.5
Brockhaus, F.6
Zhang, J.7
Angyalosi, G.8
He, E.9
Geller, D.E.10
|