Portal dosimetry for VMAT using integrated images obtained during treatment

Author keywords

arc therapy; electronic portal imaging device; in vivo dosimetry; verification; VMAT

Indexed keywords

DATA HANDLING; DOSIMETRY; ERRORS; FORECASTING; IONIZATION; IONIZATION CHAMBERS; VERIFICATION;

EID: 84894261864     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4862515     Document Type: Article
Times cited : (37)

References (49)
  • 1
    • 84880205045 scopus 로고    scopus 로고
    • In vivo dosimetry in external beam radiotherapy
    • (19p). 10.1118/1.4811216
    • B. Mijnheer, S. Beddar, J. Izewska, and C. Reft, "In vivo dosimetry in external beam radiotherapy," Med. Phys. 40, 070903 (19pp.) (2013). 10.1118/1.4811216
    • (2013) Med. Phys. , vol.40 , pp. 070903
    • Mijnheer, B.1    Beddar, S.2    Izewska, J.3    Reft, C.4
  • 2
    • 52049100092 scopus 로고    scopus 로고
    • A literature review of electronic portal imaging for radiotherapy dosimetry
    • 10.1016/j.radonc.2008.07.008
    • W. van Elmpt, L. McDermott, S. Nijsten, M. Wendling, P. Lambin, and B. Mijnheer, "A literature review of electronic portal imaging for radiotherapy dosimetry," Radiother. Oncol. 88, 289-309 (2008). 10.1016/j.radonc.2008.07.008
    • (2008) Radiother. Oncol. , vol.88 , pp. 289-309
    • Van Elmpt, W.1    McDermott, L.2    Nijsten, S.3    Wendling, M.4    Lambin, P.5    Mijnheer, B.6
  • 3
    • 0038033842 scopus 로고    scopus 로고
    • Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy
    • DOI 10.1118/1.1582469
    • P. B. Greer and C. C. Popescu, "Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy," Med. Phys. 30, 1618-1627 (2003). 10.1118/1.1582469 (Pubitemid 36885779)
    • (2003) Medical Physics , vol.30 , Issue.7 , pp. 1618-1627
    • Greer, P.B.1    Popescu, C.C.2
  • 4
    • 1242271376 scopus 로고    scopus 로고
    • Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device
    • DOI 10.1118/1.1637969
    • L. N. McDermott, R. J. W. Louwe, J.-J. Sonke, M. B. van Herk, and B. J. Mijnheer, "Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device," Med. Phys. 31, 285-295 (2004). 10.1118/1.1637969 (Pubitemid 38235398)
    • (2004) Medical Physics , vol.31 , Issue.2 , pp. 285-295
    • McDermott, L.N.1    Louwe, R.J.W.2    Sonke, J.-J.3    Van Herk, M.B.4    Mijnheer, B.J.5
  • 5
    • 9244240768 scopus 로고    scopus 로고
    • The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes
    • DOI 10.1118/1.1803751
    • R. J. W. Louwe, L. N. McDermott, J.-J. Sonke, R. Tielenburg, M. Wendling, M. B. van Herk, and B. J. Mijnheer, "The long-term stability of amorphous silicon flat panel imaging devices for dosimetry purposes," Med. Phys. 31, 2989-2995 (2004). 10.1118/1.1803751 (Pubitemid 39552688)
    • (2004) Medical Physics , vol.31 , Issue.11 , pp. 2989-2995
    • Louwe, R.J.W.1    McDermott, L.N.2    Sonke, J.-J.3    Tielenburg, R.4    Wendling, M.5    Van Herk, M.B.6    Mijnheer, B.J.7
  • 7
    • 84883770810 scopus 로고    scopus 로고
    • A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment
    • (11p). 10.1118/1.4817484
    • T. Fuangrod, H. C. Woodruff, E. van Uytven, B. M. C. McCurdy, Z. Kuncic, D. J. O'Connor, and P. B. Greer, "A system for EPID-based real-time treatment delivery verification during dynamic IMRT treatment," Med. Phys. 40, 091907 (11pp.) (2013). 10.1118/1.4817484
    • (2013) Med. Phys. , vol.40 , pp. 091907
    • Fuangrod, T.1    Woodruff, H.C.2    Van Uytven, E.3    McCurdy, B.M.C.4    Kuncic, Z.5    O'Connor, D.J.6    Greer, P.B.7
  • 8
    • 33746606839 scopus 로고    scopus 로고
    • GLAaS: An absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications
    • DOI 10.1118/1.2218314
    • G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, "GLAaS: An absolute dose calibration algorithm for an amorphous silicon portal imager. Applications to IMRT verifications," Med. Phys. 33, 2839-2851 (2006). 10.1118/1.2218314 (Pubitemid 44154555)
    • (2006) Medical Physics , vol.33 , Issue.8 , pp. 2839-2851
    • Nicolini, G.1    Fogliata, A.2    Vanetti, E.3    Clivio, A.4    Cozzi, L.5
  • 9
    • 34547115940 scopus 로고    scopus 로고
    • Implementation and validation of portal dosimetry with an amorphous silicon EPID in the energy range from 6 to 25 MV
    • DOI 10.1088/0031-9155/52/15/N05, PII S0031915507488765, N05
    • P. Winkler, A. Hefner, and D. Georg, "Implementation and validation of portal dosimetry with an amorphous silicon EPID in the energy range from 6 to 25 MV," Phys. Med. Biol. 52, N355-N365 (2007). 10.1088/0031-9155/52/15/N05 (Pubitemid 47103156)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.15
    • Winkler, P.1    Hefner, A.2    Georg, D.3
  • 10
    • 67649583518 scopus 로고    scopus 로고
    • A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments
    • 10.1118/1.3148482
    • M. Wendling, L. N. McDermott, A. Mans, J.-J. Sonke, M. van Herk, and B. J. Mijnheer, "A simple backprojection algorithm for 3D in vivo EPID dosimetry of IMRT treatments," Med. Phys. 36, 3310-3321 (2009). 10.1118/1.3148482
    • (2009) Med. Phys. , vol.36 , pp. 3310-3321
    • Wendling, M.1    McDermott, L.N.2    Mans, A.3    Sonke, J.-J.4    Van Herk, M.5    Mijnheer, B.J.6
  • 12
    • 31844436637 scopus 로고    scopus 로고
    • Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method
    • DOI 10.1118/1.2147744
    • M. Wendling, R. J. W. Louwe, L. N. McDermott, J.-J. Sonke, M. van Herk, and B. J. Mijnheer, "Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method," Med. Phys. 33, 259-273 (2006). 10.1118/1.2147744 (Pubitemid 43183967)
    • (2006) Medical Physics , vol.33 , Issue.2 , pp. 259-273
    • Wendling, M.1    Louwe, R.J.W.2    McDermott, L.N.3    Sonke, J.-J.4    Van Herk, M.5    Mijnheer, B.J.6
  • 13
    • 61349181323 scopus 로고    scopus 로고
    • Portal dose image prediction for in vivo treatment verification completely based on EPID measurements
    • 10.1118/1.3070545
    • M. van Zijtveld, M. Dirkx, M. Breuers, H. de Boer, and B. Heijmen, "Portal dose image prediction for in vivo treatment verification completely based on EPID measurements," Med. Phys. 36, 946-952 (2009). 10.1118/1.3070545
    • (2009) Med. Phys. , vol.36 , pp. 946-952
    • Van Zijtveld, M.1    Dirkx, M.2    Breuers, M.3    De Boer, H.4    Heijmen, B.5
  • 14
    • 84874783378 scopus 로고    scopus 로고
    • Model-based prediction of portal dose images during patient treatment
    • (11p). 10.1118/1.4792203
    • K. Chytyk-Praznik, E. VanUytven, T. A. vanBeek, P. B. Greer, and B. M. C. McCurdy, "Model-based prediction of portal dose images during patient treatment," Med. Phys. 40, 031713 (11pp.) (2013). 10.1118/1.4792203
    • (2013) Med. Phys. , vol.40 , pp. 031713
    • Chytyk-Praznik, K.1    Vanuytven, E.2    Vanbeek, T.A.3    Greer, P.B.4    McCurdy, B.M.C.5
  • 15
    • 34047112709 scopus 로고    scopus 로고
    • Routine individualised patient dosimetry using electronic portal imaging devices
    • DOI 10.1016/j.radonc.2007.03.003, PII S0167814007000953
    • S. M. Nijsten, B. J. Mijnheer, A. L. Dekker, P. Lambin, and A. W. Minken, "Routine individualised patient dosimetry using electronic portal imaging devices," Radiother. Oncol. 83, 65-75 (2007). 10.1016/j.radonc.2007.03.003 (Pubitemid 46527950)
    • (2007) Radiotherapy and Oncology , vol.83 , Issue.1 , pp. 65-75
    • Nijsten, S.M.J.J.G.1    Mijnheer, B.J.2    Dekker, A.L.A.J.3    Lambin, P.4    Minken, A.W.H.5
  • 16
    • 78651241852 scopus 로고    scopus 로고
    • In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams
    • 10.1016/j.ejm2010.06.002
    • P. Francois, P. Boissard, L. Berger, and A. Mazal, "In vivo dose verification from back projection of a transit dose measurement on the central axis of photon beams," Phys. Medica 27, 1-10 (2011). 10.1016/j.ejmp.2010. 06.002
    • (2011) Phys. Medica , vol.27 , pp. 1-10
    • Francois, P.1    Boissard, P.2    Berger, L.3    Mazal, A.4
  • 17
    • 34347407383 scopus 로고    scopus 로고
    • Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction
    • DOI 10.1118/1.2742778
    • W. J. van Elmpt, S. M. Nijsten, A. L. Dekker, B. J. Mijnheer, and P. Lambin, "Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction," Med. Phys. 34, 2816-2826 (2007). 10.1118/1.2742778 (Pubitemid 47019802)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2816-2826
    • Van Elmpt, W.J.C.1    Nijsten, S.M.J.J.G.2    Dekker, A.L.A.J.3    Mijnheer, B.J.4    Lambin, P.5
  • 18
    • 37549049393 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: IMRT in a single gantry arc
    • 10.1118/1.2818738
    • K. Otto, "Volumetric modulated arc therapy: IMRT in a single gantry arc," Med. Phys. 35, 310-317 (2008). 10.1118/1.2818738
    • (2008) Med. Phys. , vol.35 , pp. 310-317
    • Otto, K.1
  • 19
    • 79951862797 scopus 로고    scopus 로고
    • Intensity-modulated arc therapy: Principles, technologies and clinical implementation
    • 10.1088/0031-9155/56/5/R01
    • C. X. Yu and G. Tang, "Intensity-modulated arc therapy: Principles, technologies and clinical implementation," Phys. Med. Biol. 56, R31-R54 (2011). 10.1088/0031-9155/56/5/R01
    • (2011) Phys. Med. Biol. , vol.56
    • Yu, C.X.1    Tang, G.2
  • 20
    • 80054717095 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy: A review of current literature and clinical use in practice
    • 10.1259/bjr/22373346
    • M. Teoh, C. H. Clark, K. Wood, S. Whitaker, and A. Nisbet, "Volumetric modulated arc therapy: A review of current literature and clinical use in practice," Br. J. Radiol. 84, 967-996 (2011). 10.1259/bjr/22373346
    • (2011) Br. J. Radiol. , vol.84 , pp. 967-996
    • Teoh, M.1    Clark, C.H.2    Wood, K.3    Whitaker, S.4    Nisbet, A.5
  • 21
    • 84866771200 scopus 로고    scopus 로고
    • EPID dosimetry for pretreatment quality assurance with two commercial systems
    • 10.1120/jacmv13i4.3736
    • D. W. Bailey, L. Kumaraswamy, M. Bakhtiari, H. K. Malhotra, and M. B. Podgorsak, "EPID dosimetry for pretreatment quality assurance with two commercial systems," J. Appl. Clin. Med. Phys. 13 (4), 82-99 (2012). 10.1120/jacmp.v13i4.3736
    • (2012) J. Appl. Clin. Med. Phys. , vol.13 , Issue.4 , pp. 82-99
    • Bailey, D.W.1    Kumaraswamy, L.2    Bakhtiari, M.3    Malhotra, H.K.4    Podgorsak, M.B.5
  • 22
    • 34347388219 scopus 로고    scopus 로고
    • IMAT-SIM: A new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT)
    • DOI 10.1118/1.2739807
    • M. Iori, E. Cagni, A. E. Nahum, and G. Borasi, "IMAT-SIM: A new method for the clinical dosimetry of intensity-modulated arc therapy (IMAT)," Med. Phys. 34, 2759-2773 (2007). 10.1118/1.2739807 (Pubitemid 47019796)
    • (2007) Medical Physics , vol.34 , Issue.7 , pp. 2759-2773
    • Iori, M.1    Cagni, E.2    Nahum, A.E.3    Borasi, G.4
  • 23
    • 73649128290 scopus 로고    scopus 로고
    • Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool
    • 10.1118/1.3271107
    • M. Iori, E. Cagni, M. Paiusco, P. Munro, and A. E. Nahum, "Dosimetric verification of IMAT delivery with a conventional EPID system and a commercial portal dose image prediction tool," Med. Phys. 37, 377-390 (2010). 10.1118/1.3271107
    • (2010) Med. Phys. , vol.37 , pp. 377-390
    • Iori, M.1    Cagni, E.2    Paiusco, M.3    Munro, P.4    Nahum, A.E.5
  • 24
    • 53149135069 scopus 로고    scopus 로고
    • The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy
    • 10.1186/1748-717X-3-24
    • G. Nicolini, E. Vanetti, A. Clivio, A. Fogliata, S. Korreman, J. Bocanek, and L. Cozzi, "The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy," Radiat. Oncol. 3, 24 (2008). 10.1186/1748-717X-3-24
    • (2008) Radiat. Oncol. , vol.3 , pp. 24
    • Nicolini, G.1    Vanetti, E.2    Clivio, A.3    Fogliata, A.4    Korreman, S.5    Bocanek, J.6    Cozzi, L.7
  • 26
    • 67649622802 scopus 로고    scopus 로고
    • Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT
    • 10.1118/1.3148822
    • B. M. C. McCurdy and P. B. Greer, "Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT," Med. Phys. 36, 3028-3039 (2009). 10.1118/1.3148822
    • (2009) Med. Phys. , vol.36 , pp. 3028-3039
    • McCurdy, B.M.C.1    Greer, P.B.2
  • 29
    • 70350716798 scopus 로고    scopus 로고
    • Treatment planning for volumetric modulated arc therapy
    • 10.1118/1.3240488
    • J. L. Bedford, "Treatment planning for volumetric modulated arc therapy," Med. Phys. 36, 5128-5138 (2009). 10.1118/1.3240488
    • (2009) Med. Phys. , vol.36 , pp. 5128-5138
    • Bedford, J.L.1
  • 30
    • 84879483825 scopus 로고    scopus 로고
    • Sinogram analysis of aperture optimization by iterative least-squares in volumetric modulated arc therapy
    • 10.1088/0031-9155/58/5/1235
    • J. L. Bedford, "Sinogram analysis of aperture optimization by iterative least-squares in volumetric modulated arc therapy," Phys. Med. Biol. 58, 1235-1250 (2013). 10.1088/0031-9155/58/5/1235
    • (2013) Phys. Med. Biol. , vol.58 , pp. 1235-1250
    • Bedford, J.L.1
  • 31
    • 0037037772 scopus 로고    scopus 로고
    • Speed versus accuracy in a fast convolution photon dose calculation for conformal radiotherapy
    • DOI 10.1088/0031-9155/47/19/303, PII S0031915502379478
    • J. L. Bedford, "Speed versus accuracy in a fast convolution photon dose calculation for conformal radiotherapy," Phys. Med. Biol. 47, 3475-3484 (2002). 10.1088/0031-9155/47/19/303 (Pubitemid 35214677)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.19 , pp. 3475-3484
    • Bedford, J.L.1
  • 34
    • 84455181494 scopus 로고    scopus 로고
    • Optimising stereotactic body radiotherapy for non-small cell lung cancer with volumetric intensity-modulated arc therapy: A planning study
    • 10.1016/j.clon.2011.02.003
    • J. Brock, J. Bedford, M. Partridge, F. McDonald, S. Ashley, H. A. McNair, and M. Brada, "Optimising stereotactic body radiotherapy for non-small cell lung cancer with volumetric intensity-modulated arc therapy: A planning study," Clin. Oncol. 24, 68-75 (2012). 10.1016/j.clon.2011.02.003
    • (2012) Clin. Oncol. , vol.24 , pp. 68-75
    • Brock, J.1    Bedford, J.2    Partridge, M.3    McDonald, F.4    Ashley, S.5    McNair, H.A.6    Brada, M.7
  • 35
    • 84875427707 scopus 로고    scopus 로고
    • Assessment of the robustness of volumetric-modulated arc therapy for lung radiotherapy
    • 10.1259/bjr.20120498
    • K. Edmunds and J. Bedford, "Assessment of the robustness of volumetric-modulated arc therapy for lung radiotherapy," Br. J. Radiol. 86, 20120498 (2013). 10.1259/bjr.20120498
    • (2013) Br. J. Radiol. , vol.86 , pp. 20120498
    • Edmunds, K.1    Bedford, J.2
  • 36
    • 84455180564 scopus 로고    scopus 로고
    • Volumetric modulated arc therapy planning for distal oesophageal malignancies
    • 10.1259/bjr/25428720
    • M. A. Hawkins, J. L. Bedford, A. P. Warrington, and D. M. Tait, "Volumetric modulated arc therapy planning for distal oesophageal malignancies," Br. J. Radiol. 85, 44-52 (2012). 10.1259/bjr/25428720
    • (2012) Br. J. Radiol. , vol.85 , pp. 44-52
    • Hawkins, M.A.1    Bedford, J.L.2    Warrington, A.P.3    Tait, D.M.4
  • 37
    • 84880827823 scopus 로고    scopus 로고
    • Biological dose escalation and hypofractionation: What is there to be gained and how will it best be done?
    • 10.1016/j.clon.2013.05.003
    • A. C. Tree, E. J. Alexander, N. J. Van As, D. P. Dearnaley, and V. Khoo, "Biological dose escalation and hypofractionation: What is there to be gained and how will it best be done? "Clin. Oncol. 25, 483-498 (2013). 10.1016/j.clon.2013.05.003
    • (2013) Clin. Oncol. , vol.25 , pp. 483-498
    • Tree, A.C.1    Alexander, E.J.2    Van As, N.J.3    Dearnaley, D.P.4    Khoo, V.5
  • 38
    • 84874991150 scopus 로고    scopus 로고
    • Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator
    • 10.1120/jacmv14i2.4136
    • J. L. Bedford, M. D. R. Thomas, and G. Smyth, "Beam modeling and VMAT performance with the Agility 160-leaf multileaf collimator," J. Appl. Clin. Med. Phys. 14 (2), 172-185 (2013). 10.1120/jacmp.v14i2.4136
    • (2013) J. Appl. Clin. Med. Phys. , vol.14 , Issue.2 , pp. 172-185
    • Bedford, J.L.1    Thomas, M.D.R.2    Smyth, G.3
  • 39
    • 58149345036 scopus 로고    scopus 로고
    • Commissioning of volumetric modulated arc therapy (VMAT)
    • 10.1016/j.ijrob2008.08.055
    • J. L. Bedford and A. P. Warrington, "Commissioning of volumetric modulated arc therapy (VMAT)," Int. J. Radiat. Oncol., Biol., Phys. 73, 537-545 (2009). 10.1016/j.ijrobp.2008.08.055
    • (2009) Int. J. Radiat. Oncol., Biol., Phys. , vol.73 , pp. 537-545
    • Bedford, J.L.1    Warrington, A.P.2
  • 40
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, "A technique for the quantitative evaluation of dose distributions," Med. Phys. 25, 656-661 (1998). 10.1118/1.598248 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 41
    • 84864701518 scopus 로고    scopus 로고
    • 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification
    • 10.1118/1.4736949
    • P. Carrasco, N. Jornet, A. Latorre, T. Eudaldo, A. Ruiz, and M. Ribas, "3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification," Med. Phys. 39, 5040-5049 (2012). 10.1118/1.4736949
    • (2012) Med. Phys. , vol.39 , pp. 5040-5049
    • Carrasco, P.1    Jornet, N.2    Latorre, A.3    Eudaldo, T.4    Ruiz, A.5    Ribas, M.6
  • 42
    • 77953487894 scopus 로고    scopus 로고
    • On the insensitivity of single field planar dosimetry to IMRT inaccuracies
    • 10.1118/1.3425781
    • J. J. Kruse, "On the insensitivity of single field planar dosimetry to IMRT inaccuracies," Med. Phys. 37, 2516-2524 (2010). 10.1118/1.3425781
    • (2010) Med. Phys. , vol.37 , pp. 2516-2524
    • Kruse, J.J.1
  • 43
    • 79551672470 scopus 로고    scopus 로고
    • Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors
    • 10.1118/1.3544657
    • B. E. Nelms, H. Zhen, and W. A. Tomé, "Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors," Med. Phys. 38, 1037-1044 (2011). 10.1118/1.3544657
    • (2011) Med. Phys. , vol.38 , pp. 1037-1044
    • Nelms, B.E.1    Zhen, H.2    Tomé, W.A.3
  • 44
    • 79952153178 scopus 로고    scopus 로고
    • ICRU Report No. 83: Prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)
    • The International Commission on Radiation Units and Measurements, "," , 10.1093/jicru/ndq001
    • The International Commission on Radiation Units and Measurements, "ICRU Report No. 83: Prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)," J. ICRU 10 (1), 60-82 (2010). 10.1093/jicru/ndq001
    • (2010) J. ICRU , vol.10 , Issue.1 , pp. 60-82
  • 45
    • 33847294113 scopus 로고    scopus 로고
    • Diode in vivo dosimetry for patients receiving external beam radiation therapy
    • (Medical Physics Publishing, Madison, WI)
    • Report of Task Group 62 of the Radiation Therapy Committee, "Diode in vivo dosimetry for patients receiving external beam radiation therapy," AAPM Report No. 87 (Medical Physics Publishing, Madison, WI, 2005).
    • (2005) Report of Task Grou62 of the Radiation Therapy Committee, "," AAPM Report No. 87
  • 46
    • 84857630945 scopus 로고    scopus 로고
    • Clinical use of a novel in vivo 4D monitoring system for simultaneous patient motion and dose measurements
    • 10.1016/j.radonc.2011.08.021
    • A. J. Cherpak, J. E. Cygler, S. Andrusyk, J. Pantarotto, R. MacRae, and G. Perry, "Clinical use of a novel in vivo 4D monitoring system for simultaneous patient motion and dose measurements," Radiother. Oncol. 102, 290-296 (2012). 10.1016/j.radonc.2011.08.021
    • (2012) Radiother. Oncol. , vol.102 , pp. 290-296
    • Cherpak, A.J.1    Cygler, J.E.2    Andrusyk, S.3    Pantarotto, J.4    Macrae, R.5    Perry, G.6
  • 48
    • 51049087485 scopus 로고    scopus 로고
    • Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study
    • 10.1080/02841860802282778
    • J. L. Bedford, V. N. Hansen, H. A. McNair, A. H. Aitken, J. E. C. Brock, A. P. Warrington, and M. Brada, "Treatment of lung cancer using volumetric modulated arc therapy and image guidance: A case study," Acta Oncol. 47, 1438-1443 (2008). 10.1080/02841860802282778
    • (2008) Acta Oncol. , vol.47 , pp. 1438-1443
    • Bedford, J.L.1    Hansen, V.N.2    McNair, H.A.3    Aitken, A.H.4    Brock, J.E.C.5    Warrington, A.P.6    Brada, M.7
  • 49
    • 69649086522 scopus 로고    scopus 로고
    • British Institute of Radiology, Institute of Physics and Engineering in Medicine, National Patient Safety Agency, Society and College of Radiographers, The Royal College of Radiologists, (The Royal College of Radiologists, London, UK)
    • British Institute of Radiology, Institute of Physics and Engineering in Medicine, National Patient Safety Agency, Society and College of Radiographers, The Royal College of Radiologists, Towards Safer Radiotherapy (The Royal College of Radiologists, London, UK, 2008).
    • (2008) Towards Safer Radiotherapy


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.