-
1
-
-
51049087485
-
Treatment of lung cancer using volumetric modulated arc therapy and image guidance. A case study
-
Bedford J.L., Nordmark Hansen V., McNair H.A., et al. Treatment of lung cancer using volumetric modulated arc therapy and image guidance. A case study. Acta Oncol 47 (2008) 1438-1443
-
(2008)
Acta Oncol
, vol.47
, pp. 1438-1443
-
-
Bedford, J.L.1
Nordmark Hansen, V.2
McNair, H.A.3
-
2
-
-
60549115290
-
RapidArc volumetric modulated therapy planning for prostate cancer patients
-
Kjaer-Kristoffersen F., Ohlhues L., Medin J., and Korreman S. RapidArc volumetric modulated therapy planning for prostate cancer patients. Acta Oncol 48 (2009) 227-232
-
(2009)
Acta Oncol
, vol.48
, pp. 227-232
-
-
Kjaer-Kristoffersen, F.1
Ohlhues, L.2
Medin, J.3
Korreman, S.4
-
3
-
-
64049093906
-
Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study
-
Verbakel W.F., Cuijpers J.P., Hoffmans D., Bieker M., Slotman B.J., and Senan S. Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study. Int J Radiat Oncol Biol Phys 74 (2009) 252-259
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 252-259
-
-
Verbakel, W.F.1
Cuijpers, J.P.2
Hoffmans, D.3
Bieker, M.4
Slotman, B.J.5
Senan, S.6
-
4
-
-
70350502597
-
Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer
-
Wolff D., Stieler F., Welzel G., et al. Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. Radiother Oncol 93 (2009) 226-233
-
(2009)
Radiother Oncol
, vol.93
, pp. 226-233
-
-
Wolff, D.1
Stieler, F.2
Welzel, G.3
-
5
-
-
70350499496
-
Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?
-
Guckenberger M., Richter A., Krieger T., Wilbert J., Baier K., and Flentje M. Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes?. Radiother Oncol 93 (2009) 259-265
-
(2009)
Radiother Oncol
, vol.93
, pp. 259-265
-
-
Guckenberger, M.1
Richter, A.2
Krieger, T.3
Wilbert, J.4
Baier, K.5
Flentje, M.6
-
6
-
-
70349337606
-
Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs
-
Verbakel W.F., Senan S., Cuijpers J.P., Slotman B.J., and Lagerwaard F.J. Rapid delivery of stereotactic radiotherapy for peripheral lung tumors using volumetric intensity-modulated arcs. Radiother Oncol 93 (2009) 122-124
-
(2009)
Radiother Oncol
, vol.93
, pp. 122-124
-
-
Verbakel, W.F.1
Senan, S.2
Cuijpers, J.P.3
Slotman, B.J.4
Lagerwaard, F.J.5
-
7
-
-
67649889107
-
Evaluation of the Delta4 phantom for IMRT and VMAT verification
-
Bedford J.L., Lee Y.K., Wai P., South C.P., and Warrington A.P. Evaluation of the Delta4 phantom for IMRT and VMAT verification. Phys Med Biol 54 (2009) N167-N176
-
(2009)
Phys Med Biol
, vol.54
-
-
Bedford, J.L.1
Lee, Y.K.2
Wai, P.3
South, C.P.4
Warrington, A.P.5
-
8
-
-
34748872532
-
On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom
-
van Esch A., Clermont C., Devillers M., Iori M., and Huyskens D.P. On-line quality assurance of rotational radiotherapy treatment delivery by means of a 2D ion chamber array and the Octavius phantom. Med Phys 34 (2007) 3825-3837
-
(2007)
Med Phys
, vol.34
, pp. 3825-3837
-
-
van Esch, A.1
Clermont, C.2
Devillers, M.3
Iori, M.4
Huyskens, D.P.5
-
9
-
-
60549084371
-
Dosimetric verification of RapidArc treatment delivery
-
Korreman S., Medin J., and Kjaer-Kristoffersen F. Dosimetric verification of RapidArc treatment delivery. Acta Oncol 48 (2009) 185-191
-
(2009)
Acta Oncol
, vol.48
, pp. 185-191
-
-
Korreman, S.1
Medin, J.2
Kjaer-Kristoffersen, F.3
-
10
-
-
33749393203
-
Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification
-
McDermott L.N., Wendling M., van Asselen B., et al. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification. Med Phys 33 (2006) 3921-3930
-
(2006)
Med Phys
, vol.33
, pp. 3921-3930
-
-
McDermott, L.N.1
Wendling, M.2
van Asselen, B.3
-
11
-
-
33947492059
-
Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT
-
McDermott L.N., Wendling M., Sonke J.J., van Herk M., and Mijnheer B.J. Replacing pretreatment verification with in vivo EPID dosimetry for prostate IMRT. Int J Radiat Oncol Biol Phys 67 (2007) 1568-1577
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.67
, pp. 1568-1577
-
-
McDermott, L.N.1
Wendling, M.2
Sonke, J.J.3
van Herk, M.4
Mijnheer, B.J.5
-
12
-
-
38149111288
-
3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT
-
McDermott L.N., Wendling M., Nijkamp J., et al. 3D in vivo dose verification of entire hypo-fractionated IMRT treatments using an EPID and cone-beam CT. Radiother Oncol 86 (2008) 35-42
-
(2008)
Radiother Oncol
, vol.86
, pp. 35-42
-
-
McDermott, L.N.1
Wendling, M.2
Nijkamp, J.3
-
13
-
-
31844436637
-
Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method
-
Wendling M., Louwe R.J.W., McDermott L.N., Sonke J.-J., van Herk M., and Mijnheer B.J. Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method. Med Phys 33 (2006) 259-273
-
(2006)
Med Phys
, vol.33
, pp. 259-273
-
-
Wendling, M.1
Louwe, R.J.W.2
McDermott, L.N.3
Sonke, J.-J.4
van Herk, M.5
Mijnheer, B.J.6
-
14
-
-
67649583518
-
A simple back-projection algorithm for 3D EPID dosimetry of IMRT treatments
-
Wendling M., McDermott L.N., Mans A., Sonke J.-J., van Herk M., and Mijnheer B. A simple back-projection algorithm for 3D EPID dosimetry of IMRT treatments. Med Phys 36 (2009) 3310-3321
-
(2009)
Med Phys
, vol.36
, pp. 3310-3321
-
-
Wendling, M.1
McDermott, L.N.2
Mans, A.3
Sonke, J.-J.4
van Herk, M.5
Mijnheer, B.6
-
15
-
-
67649622802
-
Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT
-
McCurdy B.M., and Greer P.B. Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT. Med Phys 36 (2009) 3028-3039
-
(2009)
Med Phys
, vol.36
, pp. 3028-3039
-
-
McCurdy, B.M.1
Greer, P.B.2
-
16
-
-
17844380035
-
Accurate technique for complete geometric calibration of cone-beam computed tomography systems
-
Cho Y., Moseley D.J., Siewerdsen J.H., and Jaffray D.A. Accurate technique for complete geometric calibration of cone-beam computed tomography systems. Med Phys 32 (2005) 968-983
-
(2005)
Med Phys
, vol.32
, pp. 968-983
-
-
Cho, Y.1
Moseley, D.J.2
Siewerdsen, J.H.3
Jaffray, D.A.4
-
17
-
-
34247559829
-
A fast algorithm for gamma evaluation in 3D
-
Wendling M., Zijp L., McDermott L.N., et al. A fast algorithm for gamma evaluation in 3D. Med Phys 34 5 (2007) 1647-1654
-
(2007)
Med Phys
, vol.34
, Issue.5
, pp. 1647-1654
-
-
Wendling, M.1
Zijp, L.2
McDermott, L.N.3
-
18
-
-
77249124738
-
-
Wendling M, McDermott L, Mans A, Sonke J-J, van Herk M, Mijnheer B. 3D dose verification for lung cancer treatments by in aqua vivo EPID dosimetry. Radiother Oncol 2008;88(Suppl. 2): S160-1. 2008. [Abstract].
-
Wendling M, McDermott L, Mans A, Sonke J-J, van Herk M, Mijnheer B. 3D dose verification for lung cancer treatments by in aqua vivo EPID dosimetry. Radiother Oncol 2008;88(Suppl. 2): S160-1. 2008. [Abstract].
-
-
-
-
19
-
-
66449086805
-
Development and evaluation of an efficient approach to volumetric arc therapy planning
-
Bzdusek K., Friberger H., Eriksson K., Hardemark B., Robinson D., and Kaus M. Development and evaluation of an efficient approach to volumetric arc therapy planning. Med Phys 36 (2009) 2328-2339
-
(2009)
Med Phys
, vol.36
, pp. 2328-2339
-
-
Bzdusek, K.1
Friberger, H.2
Eriksson, K.3
Hardemark, B.4
Robinson, D.5
Kaus, M.6
-
20
-
-
1242271376
-
Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device
-
McDermott L.N., Louwe R.J.W., Sonke J.-J., van Herk M., and Mijnheer B.J. Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device. Med Phys 31 (2004) 285-295
-
(2004)
Med Phys
, vol.31
, pp. 285-295
-
-
McDermott, L.N.1
Louwe, R.J.W.2
Sonke, J.-J.3
van Herk, M.4
Mijnheer, B.J.5
-
21
-
-
67349247094
-
Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance
-
Sonke J.J., Rossi M., Wolthaus J., van Herk M., Damen E., and Belderbos J. Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 74 (2009) 567-574
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 567-574
-
-
Sonke, J.J.1
Rossi, M.2
Wolthaus, J.3
van Herk, M.4
Damen, E.5
Belderbos, J.6
-
22
-
-
37549049393
-
Volumetric modulated arc therapy: IMRT in a single gantry arc
-
Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys 35 (2008) 310-317
-
(2008)
Med Phys
, vol.35
, pp. 310-317
-
-
Otto, K.1
-
23
-
-
61449100537
-
First clinical cone-beam CT imaging during volumetric modulated arc therapy
-
Nakagawa K., Haga A., Shiraishi K., et al. First clinical cone-beam CT imaging during volumetric modulated arc therapy. Radiother Oncol 90 (2009) 422-423
-
(2009)
Radiother Oncol
, vol.90
, pp. 422-423
-
-
Nakagawa, K.1
Haga, A.2
Shiraishi, K.3
|