메뉴 건너뛰기




Volumn 34, Issue 7, 2007, Pages 2816-2826

Treatment verification in the presence of inhomogeneities using EPID-based three-dimensional dose reconstruction

Author keywords

EPID; IMRT verification; Monte Carlo dose calculation; Portal dosimetry; Pre treatment verification

Indexed keywords

AMORPHOUS SILICON; BIOMEDICAL ENGINEERING; ENGINES; FAST FOURIER TRANSFORMS; IMAGE RECONSTRUCTION; LINEAR ACCELERATORS; MONTE CARLO METHODS; PHANTOMS; RADIOTHERAPY; TISSUE;

EID: 34347407383     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2742778     Document Type: Article
Times cited : (38)

References (33)
  • 1
    • 0036703563 scopus 로고    scopus 로고
    • Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator
    • X. R. Zhu, P. A. Jursinic, D. F. Grimm, F. Lopez, J. J. Rownd, and M. T. Gillin, " Evaluation of Kodak EDR2 film for dose verification of intensity modulated radiation therapy delivered by a static multileaf collimator., " Med. Phys. 29, 1687-1692 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1687-1692
    • Zhu, X.R.1    Jursinic, P.A.2    Grimm, D.F.3    Lopez, F.4    Rownd, J.J.5    Gillin, M.T.6
  • 2
    • 1642495624 scopus 로고    scopus 로고
    • Verification of IMRT fields by film dosimetry
    • M. Bucciolini, F. B. Buonamici, and M. Casati, " Verification of IMRT fields by film dosimetry., " Med. Phys. 31, 161-168 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 161-168
    • Bucciolini, M.1    Buonamici, F.B.2    Casati, M.3
  • 4
    • 0036735811 scopus 로고    scopus 로고
    • Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance
    • A. J. Olch, " Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance., " Med. Phys. 29, 2159-2168 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2159-2168
    • Olch, A.J.1
  • 5
    • 1242271374 scopus 로고    scopus 로고
    • Verification of treatment parameter transfer by means of electronic portal dosimetry
    • S. M. J. J. G. Nijsten, A. W. H. Minken, P. Lambin, and I. A. D. Bruinvis, " Verification of treatment parameter transfer by means of electronic portal dosimetry., " Med. Phys. 31, 341-347 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 341-347
    • Nijsten, S.M.J.J.G.1    Minken, A.W.H.2    Lambin, P.3    Bruinvis, I.A.D.4
  • 6
    • 0031803138 scopus 로고    scopus 로고
    • Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams
    • K. L. Pasma, B. J. M. Heijmen, M. Kroonwijk, and A. G. Visser, " Portal dose image (PDI) prediction for dosimetric treatment verification in radiotherapy. I. An algorithm for open beams., " Med. Phys. 25, 830-840 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 830-840
    • Pasma, K.L.1    Heijmen, B.J.M.2    Kroonwijk, M.3    Visser, A.G.4
  • 7
    • 0031854569 scopus 로고    scopus 로고
    • Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation
    • K. L. Pasma, M. Kroonwijk, J. C. J. de Boer, A. G. Visser, and B. J. M. Heijmen, " Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation., " Phys. Med. Biol. 43, 2047-2060 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2047-2060
    • Pasma, K.L.1    Kroonwijk, M.2    De Boer, J.C.J.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 8
    • 1942478371 scopus 로고    scopus 로고
    • The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields
    • A. Van Esch, T. Depuydt, and D. P. Huyskens, " The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields., " Radiother. Oncol. 71, 223-234 (2004).
    • (2004) Radiother. Oncol. , vol.71 , pp. 223-234
    • Van Esch, A.1    Depuydt, T.2    Huyskens, D.P.3
  • 9
    • 0034977377 scopus 로고    scopus 로고
    • Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device
    • B. M. McCurdy, K. Luchka, and S. Pistorius, " Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device., " Med. Phys. 28, 911-924 (2001).
    • (2001) Med. Phys. , vol.28 , pp. 911-924
    • McCurdy, B.M.1    Luchka, K.2    Pistorius, S.3
  • 12
    • 31844436637 scopus 로고    scopus 로고
    • Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method
    • M. Wendling, R. J. W. Louwe, L. N. McDermott, J. J. Sonke, M. van Herk, and B. J. Mijnheer, " Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method., " Med. Phys. 33, 259-273 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 259-273
    • Wendling, M.1    Louwe, R.J.W.2    McDermott, L.N.3    Sonke, J.J.4    Van Herk, M.5    Mijnheer, B.J.6
  • 13
    • 0347625746 scopus 로고    scopus 로고
    • Dosimetric IMRT verification with a flat-panel EPID
    • B. Warkentin, S. Steciw, S. Rathee, and B. G. Fallone, " Dosimetric IMRT verification with a flat-panel EPID., " Med. Phys. 30, 3143-3155 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 3143-3155
    • Warkentin, B.1    Steciw, S.2    Rathee, S.3    Fallone, B.G.4
  • 14
    • 0036081692 scopus 로고    scopus 로고
    • Gel dosimetry for the dose verification of intensity modulated radiotherapy treatments
    • Y. De Deene, " Gel dosimetry for the dose verification of intensity modulated radiotherapy treatments., " Z. Med. Phys. 12, 77-88 (2002).
    • (2002) Z. Med. Phys. , vol.12 , pp. 77-88
    • De Deene, Y.1
  • 15
    • 0036703540 scopus 로고    scopus 로고
    • IMRT verification by three-dimensional dose reconstruction from portal beam measurements
    • M. Partridge, M. Ebert, and B. M. Hesse, " IMRT verification by three-dimensional dose reconstruction from portal beam measurements., " Med. Phys. 29, 1847-1858 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1847-1858
    • Partridge, M.1    Ebert, M.2    Hesse, B.M.3
  • 16
    • 0141631863 scopus 로고    scopus 로고
    • Three-dimensional dose reconstruction of breast cancer treatment using portal imaging
    • R. J. W. Louwe, E. M. F. Damen, M. van Herk, A. W. H. Minken, O. Torzsok, and B. J. Mijnheer, " Three-dimensional dose reconstruction of breast cancer treatment using portal imaging., " Med. Phys. 30, 2376-2389 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2376-2389
    • Louwe, R.J.W.1    Damen, E.M.F.2    Van Herk, M.3    Minken, A.W.H.4    Torzsok, O.5    Mijnheer, B.J.6
  • 18
    • 14644390214 scopus 로고    scopus 로고
    • Three-dimensional IMRT verification with a flat-panel EPID
    • S. Steciw, B. Warkentin, S. Rathee, and B. G. Fallone, " Three-dimensional IMRT verification with a flat-panel EPID., " Med. Phys. 32, 600-612 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 600-612
    • Steciw, S.1    Warkentin, B.2    Rathee, S.3    Fallone, B.G.4
  • 19
    • 0345256650 scopus 로고    scopus 로고
    • A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions
    • W. D. Renner, M. Sarfaraz, M. A. Earl, and C. X. Yu, " A dose delivery verification method for conventional and intensity-modulated radiation therapy using measured field fluence distributions., " Med. Phys. 30, 2996-3005 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2996-3005
    • Renner, W.D.1    Sarfaraz, M.2    Earl, M.A.3    Yu, C.X.4
  • 21
    • 33644624754 scopus 로고    scopus 로고
    • Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry
    • J. Chen, C. F. Chuang, O. Morin, M. Aubin, and J. Pouliot, " Calibration of an amorphous-silicon flat panel portal imager for exit-beam dosimetry., " Med. Phys. 33, 584-594 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 584-594
    • Chen, J.1    Chuang, C.F.2    Morin, O.3    Aubin, M.4    Pouliot, J.5
  • 23
    • 0032772588 scopus 로고    scopus 로고
    • Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm
    • M. Fippel, " Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm., " Med. Phys. 26, 1466-1475 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1466-1475
    • Fippel, M.1
  • 25
    • 1242271376 scopus 로고    scopus 로고
    • Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device
    • L. N. McDermott, R. J. W. Louwe, J. J. Sonke, M. B. van Herk, and B. J. Mijnheer, " Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device., " Med. Phys. 31, 285-295 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 285-295
    • McDermott, L.N.1    Louwe, R.J.W.2    Sonke, J.J.3    Van Herk, M.B.4    Mijnheer, B.J.5
  • 26
    • 0034129338 scopus 로고    scopus 로고
    • Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
    • M. Miften, M. Wiesmeyer, S. Monthofer, and K. Krippner, " Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system., " Phys. Med. Biol. 45, 817-833 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 817-833
    • Miften, M.1    Wiesmeyer, M.2    Monthofer, S.3    Krippner, K.4
  • 27
    • 85024951939 scopus 로고    scopus 로고
    • Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system
    • M. Miften, M. Wiesmeyer, A. Kapur, and C. M. Ma, " Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system., " J. Appl. Clin. Med. Phys. 2, 21-31 (2001).
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , pp. 21-31
    • Miften, M.1    Wiesmeyer, M.2    Kapur, A.3    Ma, C.M.4
  • 28
    • 0034036210 scopus 로고    scopus 로고
    • Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations
    • J. V. Siebers, P. J. Keall, A. E. Nahum, and R. Mohan, " Converting absorbed dose to medium to absorbed dose to water for Monte Carlo based photon beam dose calculations., " Phys. Med. Biol. 45, 983-995 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 983-995
    • Siebers, J.V.1    Keall, P.J.2    Nahum, A.E.3    Mohan, R.4
  • 29
    • 33748939057 scopus 로고    scopus 로고
    • Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to water
    • N. Dogan, J. V. Siebers, and P. J. Keall, " Clinical comparison of head and neck and prostate IMRT plans using absorbed dose to medium and absorbed dose to water., " Phys. Med. Biol. 51, 4967-4980 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , pp. 4967-4980
    • Dogan, N.1    Siebers, J.V.2    Keall, P.J.3
  • 30
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, " A technique for the quantitative evaluation of dose distributions., " Med. Phys. 25, 656-661 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 31
    • 14544300121 scopus 로고    scopus 로고
    • Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans
    • M. Stock, B. Kroupa, and D. Georg, " Interpretation and evaluation of the gamma index and the gamma index angle for the verification of IMRT hybrid plans., " Phys. Med. Biol. 50, 399-411 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 399-411
    • Stock, M.1    Kroupa, B.2    Georg, D.3
  • 33
    • 25844468645 scopus 로고    scopus 로고
    • An inter-centre quality assurance network for IMRT verification: Results of the ESTRO QUASIMODO project
    • S. Gillis, C. de Wagter, J. Bohsung, B. Perrin, P. Williams, and B. J. Mijnheer, " An inter-centre quality assurance network for IMRT verification: Results of the ESTRO QUASIMODO project., " Radiother. Oncol. 76, 340-353 (2005).
    • (2005) Radiother. Oncol. , vol.76 , pp. 340-353
    • Gillis, S.1    De Wagter, C.2    Bohsung, J.3    Perrin, B.4    Williams, P.5    Mijnheer, B.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.